Have a look at the manual Lucent Technologies DEFINITY Enterprise Communication Server Release 8.2 Installation, Upgrades, And Additions For Compact Modular Cabinets Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 413 Lucent Technologies manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.
DEFINITY ECS Release 8.2 Installation, Upgrades, and Additions for Compact Modular Cabinets 555-233-118 Issue 1 April 2000 Installing and Cabling the Cabinets 1-25 Install Main Distribution Frame and External Modem 1 Install Main Distribution Frame and External Modem Install the MDF !CAUTION: The op tional MDF is a sp ec ial 110 c ross-c onnec t field and is smaller than stand ard 110 c ross-c onnec t hard ware. Do not install stand ard 110 hard ware insid e the rig ht p anel. NOTE: The dep th of any equip ment installed insid e the rig ht p anel must not exc eed 2.5 inc hes (6.3 c m), otherwise the rig ht c over p anel c annot fit over the rig ht p anel. The op tional MDF rep resents the trunk/auxiliary field . 1. Mount the optional MDF to the right panel using one of the following: nFor b ottom-mount MDFs, refer to ‘‘Bottom-mounted MDF with Modem’’ on page 1-25. nFor top -mount MDFs (in c ab inets other than c ab inet A), refer to ‘‘Top-Mounted MDF’’ on page 1-27 . nFor d ual-mount MDFs, refer to ‘‘Dual MDFs’’ on page 1-28. Bottom-mounted MDF with Modem 1. On the rear of the MDF, c ut the c ab le tie sec uring the top 5 c ables to the MDF mounting frame. 2. Mount the MDF to the rig ht panel. See Figure 1-16 . 3. Sec ure all 10 c ab les to the b ottom left b rac ket on the MDF with a c ab le tie.
DEFINITY ECS Release 8.2 Installation, Upgrades, and Additions for Compact Modular Cabinets 555-233-118 Issue 1 April 2000 Installing and Cabling the Cabinets 1-26 Install Main Distribution Frame and External Modem 1 Figure 1-16. Typical Bottom-Mount MDF and Modem Cable Routing Figure Notes 1. Main d istrib ution frame (MDF) 2. External mod em3. Proc essor interfac e c ab le (c onnec t P2 to mod em, c onnec t J1 to c ab le 1 on MDF) 4. #12 x 1-inc h should er sc rew cadmrpnl KLC 070698 1 1 2 5 6 7 8 4 3 9 10 3 1 2 4 10 10 9 9 8 8 7 7 6 6 5 5 4 4 3 3 2 2 1 1
DEFINITY ECS Release 8.2 Installation, Upgrades, and Additions for Compact Modular Cabinets 555-233-118 Issue 1 April 2000 Installing and Cabling the Cabinets 1-27 Install Main Distribution Frame and External Modem 1 Top-Mounted MDF Use this c onfig uration when the c ab inet is wall-mounted , and is near the floor. Do not use this c onfig uration for c ab inet A. Figure 1-17. Typical Top-Mount MDF Cable Routing 1. On the rear of the MDF, c ut the c ab le tie sec uring the top 5 c ables to the MDF mounting frame. 2. Mount the MDF to the rig ht panel. See Figure 1-17 . 3. Sec ure all 10 c ab les to the b ottom left b rac ket on the MDF with a c ab le tie. Figure Notes 1. Main d istrib ution frame (MDF) 2. Connec t c ab le 1 to slot 13. #12 x 1-inc h should er sc rew cadmmdf2 KLC 070698 1 2 5 6 7 8 4 3 9 10 1 2 3 10 10 9 9 8 8 7 7 6 6 5 5 4 4 3 3 2 2 1 1
DEFINITY ECS Release 8.2 Installation, Upgrades, and Additions for Compact Modular Cabinets 555-233-118 Issue 1 April 2000 Installing and Cabling the Cabinets 1-28 Install Main Distribution Frame and External Modem 1 Dual MDFs Use this c onfig uration when mounting two MDFs. Figure 1-18. Preliminary Dual-Mount MDF Cable Routing Figure Notes 1. Main d istrib ution frame (MDF) 2. Connec t c ab le 1 to slot 13. To external mod em 2 cadmrpn2 KLC 070698 1 3 1 2 5 6 7 8 4 3 9 10 1 10 10 9 9 8 8 7 7 6 6 5 5 4 4 3 3 2 2 1 1
DEFINITY ECS Release 8.2 Installation, Upgrades, and Additions for Compact Modular Cabinets 555-233-118 Issue 1 April 2000 Installing and Cabling the Cabinets 1-29 Install Main Distribution Frame and External Modem 1 1. On the rear of the MDF, c ut the c ab le tie sec uring the top 5 c ables to the MDF mounting frame. 2. Mount the MDF to the b ottom p osition on the rig ht p anel. See Figure 1-18 . 3. Sec ure all 10 c ab les to the b ottom left b rac ket on the MDF with a c ab le tie. 4. Mount the sec ond MDF to the top p osition on the rig ht p anel. See Figure 1-19 . Figure 1-19. Typical Dual-Mount MDF Cable Routing Figure Notes 1. Main d istrib ution frame (MDF) 2. #12 x 1-inc h should er sc rew cadmrpn3 LJK 050198 1 2 5 6 7 8 4 3 9 10 2 1 2 5 6 7 8 4 3 9 10 1 10 10 9 9 8 8 7 7 6 6 5 5 4 4 3 3 2 2 1 1
DEFINITY ECS Release 8.2 Installation, Upgrades, and Additions for Compact Modular Cabinets 555-233-118 Issue 1 April 2000 Installing and Cabling the Cabinets 1-30 Install Main Distribution Frame and External Modem 1 Install the External Modem The U.S. Rob otic s Sp ortster Mod el USR 33.6 EXT external mod em is the rec ommend ed external mod em. Release 8 CMC systems op erate with this mod em set to the fac tory d efault setting s. NOTE: You may use a loc ally ob tained , typ e-ap p roved external mod em (33.6 kb p s and V.34 protoc ol). Contac t your Luc ent Tec hnolog ies rep resentative for more information. 1. Use installer-p rovid ed hard ware to mount the mod em. See Figure 1-16 . If top -mounting MDFs or d ual-mounting MDFs, mount the external mod em to the p lywood in a loc ation whic h allows the stand ard c onnec tion to the interc onnec t c ab le. 2. Route the MODEM c ab le (P2) from the Proc essor Interfac e Cab le throug h the c ab le troug h and to the mod em. 3. Connec t the c ab le to the mod em. Refer to ‘‘Processor Interface Cable Pinout’’ on page 2-11 for the p inout of the mod em c able. 4. Plug the mod em p ower c ord into an elec tric al outlet and turn on the mod em. 5. Mod em setup and ad ministration is p erformed in ‘‘External Modem Option Settings’’ on page 1-107.
DEFINITY ECS Release 8.2 Installation, Upgrades, and Additions for Compact Modular Cabinets 555-233-118 Issue 1 April 2000 Installing and Cabling the Cabinets 1-31 Install Equipment Room Hardware 1 Install Equipment Room Hardware Refer to DEFINITY Communic ations System Generic 1 and Generic 3 Main Distrib ution Field Desig n, 555-230-630, for more information. Cross-Connect the Cabinets to the MDF 1. Cross-c onnec t the ports on the trunk and line c irc uit p ac ks to the MDF as req uired. See Figure 1-21 on page 1-37 . Allowable Circuit Packs for CMC Table 1-2 lists the c irc uit p ac ks that c an b e used with Release 8. Table 1-2. Circuit Packs and Circuit Modules Apparatus Code Name ED - 1 E5 6 8 (TN2169) (TN567)DEFINITY AUDIX R3 System ED - 1 E5 6 8 (TN2170)CallVisor ASAI over the DEFINITY (LAN) Gateway R1 J58890M-1 (TN801)CallVisor ASAI/Call Visor PC/LAN over the DEFINITY LAN Gateway R2 NAA1 Fib er Op tic Cab le Ad ap ter Circ uit Pac k TN429/B/C/D Analog Direc t Inward /Outward Dialing (DIOD) Central Offic e Trunk TN433 Voic e Synthesizer TN436B Direc t Inward Dialing Trunk TN439 Tie Trunk TN459B Direc t Inward Dialing Trunk TN464F DS1 Interfac e - T1, 24 Channel - E1, 32 Channel TN465C Central Offic e Trunk TN497 Tie Trunk - Italy TN556B/C/D ISDN-BRI 4-Wire S/T-NT Interfac e TN568 Definity AUDIX Slim Continued on next page
DEFINITY ECS Release 8.2 Installation, Upgrades, and Additions for Compact Modular Cabinets 555-233-118 Issue 1 April 2000 Installing and Cabling the Cabinets 1-32 Install Equipment Room Hardware 1 TN570C Exp ansion Interfac e TN725B Sp eec h Synthesizer TN726B Data Line TN744C/D Call Classifier - Detec tor TN746B Analog Line TN747/B Central Offic e Trunk TN750B/C Announc ement TN753/B Direc t Inward Dialing Trunk TN754/B/C Dig ital Line 4-Wire DCP TN758 Pooled Modem TN760B/C/D/E Tie Trunk TN762/B Hyb rid Line TN763B/C/D Auxiliary Trunk TN767B/C/D/E DS1 Interfac e - T1, 24 Channel TN789 Radio Controller TN791 Analog Line TN793 Analog Line, 24-Port, 2-Wire TN797 Analog CO Trunk and Line Comb o TN798B Proc essor TN799B Control LAN (C-LAN) TN801 LAN Gateway Interfac e TN802B IP Interfac e Assemb ly TN1654 DS1 Converter TN2135 Analog Line TN2140B Tie Trunk TN2146 Direc t Inward Dialing Trunk TN2147C Central Offic e Trunk TN2181 Dig ital Line - 16 p orts, 2-Wire DCP Table 1-2. Circuit Packs and Circuit Modules — Continued Apparatus Code Name Continued on next page
DEFINITY ECS Release 8.2 Installation, Upgrades, and Additions for Compact Modular Cabinets 555-233-118 Issue 1 April 2000 Installing and Cabling the Cabinets 1-33 Install Equipment Room Hardware 1 Circuit Pack Installation !CAUTION: When hand ling c irc uit pac ks or any c omp onents of a DEFINITY System, always wear an authorized wrist g round strap . Connec t the strap to the g round c onnec tor provid ed on the system c ab inet. NOTE: Unlike p revious releases of DEFINITY, the c irc uit p ac k slots in the CMC are not p urp le or white. This is b ec ause all of the c irc uit p ac k slots in the CMC are “ universal slots.” That is, any slot c an c ontain any typ e of port circuit pack. TN2182/B Tone-Cloc k - Tone Detec tor and Call Classifier TN2183 Analog Line TN2184 DIOD Trunk TN2185/B ISDN-BRI 4-Wire S/T-TE Interfac e (Trunk Sid e) TN2198 ISDN-BRI 2-Wire U Interfac e TN2199 Central Offic e Trunk TN2214/B Dig ital Line, 24-Port, 2-Wire DCP - Categ ory B TN2215 Analog Line, 16-Port 2-Wire - Categ ory B TN2224/B Digital Line, 24-Port, 2-Wire DCP TN2305 ATM Interfac e (Multimod e) TN2306 ATM Interfac e (Sing le-Mod e) TN2313 DS1 Interfac e TN2464 DS1 Interfac e - T1, 24 Channel - E1, 32 Channel TN2793/B Analog Line 24-Port Table 1-2. Circuit Packs and Circuit Modules — Continued Apparatus Code Name Continued on next page
DEFINITY ECS Release 8.2 Installation, Upgrades, and Additions for Compact Modular Cabinets 555-233-118 Issue 1 April 2000 Installing and Cabling the Cabinets 1-34 Install Equipment Room Hardware 1 Circuit Pack Slot Loading In g eneral, load the c irc uit pac ks so that the numb er of p ac ks in eac h c ab inet is ab out eq ual and the trunks and lines are evenly d istrib uted among the c ab inets. See Figure 1-20 . 1. Install the TN798B Proc essor c irc uit pac k in slot 1 of Cab inet A. 2. Install the TN2182B Tone-Cloc k c irc uit p ac k in slot 2 of Cabinet A. Load all p ort c irc uit p ac ks starting with Cab inet A first, Cab inet B next, and so forth. Return to Cab inet A and repeat. 3. A TN744D Call Classifier/Tone Detec tor c irc uit p ac k may b e req uired in systems with heavy traffic . Install the TN744D into any p ort slot. Slot 1 of Cab inet B is preferred . 4. See Table 1-3 for the rec ommend ed c irc uit p ac k layout for the c ontrol c arrier and the p ort c arriers.