    Have a look at the manual Lucent Technologies DEFINITY Enterprise Communication Server Release 8.2 Installation, Upgrades, And Additions For Compact Modular Cabinets Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 413 Lucent Technologies manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.

    							DEFINITY ECS Release 8.2 Installation, Upgrades, 
    and Additions for Compact Modular Cabinets  555-233-118  Issue 1
    April 2000
    Adding or Removing Hardware 
    4-9 Add Multiple Integrated Recorded Announcement 
    4
    Replace a TN750/B with a TN750C or Move all
    Announcements from a TN750/B to a TN750C 
    Use this p roc ed ure to replac e a TN750/B c irc uit p ac k with a TN750C c irc uit p ac k 
    or to move every announc ement from a TN750/B to a TN750C.
    !CAUTION:
    Do not c op y or restore announc ements from a TN750C to a TN750 or 
    TN750B c irc uit p ac k, as this may c orrupt the announc ement d ata.
    1. Save announc ements from the TN750/B to the translation c ard .
    2. Insert the TN750C into a vac ant slot of a c arrier.
    3. Type add data-module next
     and press 
    En t e r to ad minister a new d ata 
    mod ule on the TN750C. 
    4. Type announcement
     in the Type
     field .
    5. Typ e the loc ation in the Board
     field and press 
    En te r.
    6. Type restore announcements
       for the TN750C.
    Wait until announc ements c op y from voic e RAM to flash memory (yellow 
    LED on the TN750C stop s flashing ). This may take ab out 10 minutes.
    7. Type busyout board 
     and press 
    En t e r for the TN750/B.
    8. Type change integrated announcements
     and press 
    En te r. This mod ifies 
    the translations for the TN750/B to referenc e the TN750C c irc uit pac k.
    9. Verify prop er p layb ac k of the announc ements from the TN750C.
    10. Typ e release board 
     and 
    p ress 
    En te r for the TN750/B.
    11. Remove the TN750/B c irc uit p ac k if it is no long er nec essary.
    Add TN750C Circuit Packs
    1. Insert the TN750C into a vac ant slot in a c arrier and ad minister a new d ata 
    mod ule on the TN750C, as d esc rib ed  in DEFINITY Enterp rise 
    Communic ations Server Release 8 Ad ministrator’s Guid e.
    2. To ad minister new announc ements to that TN750C slot, type change 
    announcements
      and press 
    En t e r.
    3. Rec ord  the announc ements, as d esc ribed  in DEFINITY Enterp rise 
    Communic ations Server Release 8 Ad ministrator’s Guid e.
    Wait until the announc ements c op y from voic e RAM to the onb oard  flash 
    memory (the yellow LED on the TN750C starts and  then stops flashing ). 
    This takes ab out 10 minutes. 
    						
    							DEFINITY ECS Release 8.2 Installation, Upgrades, 
    and Additions for Compact Modular Cabinets  555-233-118  Issue 1
    April 2000
    Adding or Removing Hardware 
    4-10 Add ISDN — PRI 
    4
    Move a Single Announcement to Another 
    Announcement Circuit Pack 
    1. Type change announcements 
    and 
    press En t e r to c hang e the c irc uit pac k 
    loc ations of a p artic ular announc ement. (You may also c hang e the 
    c omp ression rate at this time.)
    2. Move the announc ement, as desc rib ed  in DEFINITY Enterp rise 
    Communic ations Server Release 8 Ad ministrator’s Guid e.
    Add ISDN — PRI
    North American
    1. Install a TN767E (or later) DS1 or a TN464F DS1/E1 c irc uit pac k for a 
    sig naling  link and  up  to 23 ISDN — PRI Trunk Group members. 
    2. Install a Tone-Cloc k c irc uit p ac k to p rovid e sync hronization for the DS1 
    circuit pack. 
    If using  a TN464F, then p ac ket b us sup p ort has not b een ad d ed , req uiring  more 
    than 8 PRI signaling groups. See ‘‘Add Packet Bus Support’’ on page 4-11
     for 
    adding circuit packs for packet bus support.
    International
    1. Install a TN464C (or later) DS1/E1 c irc uit p ac k for the assig nment of the 2 
    sig naling  c hannels and  up  to 30 ISDN — PRI Trunk Group  memb ers. Eac h 
    E1 sp an p rovid es 32 p orts. 
    2. Install a Tone-Cloc k c irc uit pac k to p rovid e sync hronization for the DS1/E1 
    circuit pack.
    If using  a TN464F, then p ac ket b us sup p ort has not b een ad d ed , req uiring  more 
    than 8 PRI signaling groups. See ‘‘Add Packet Bus Support’’ on page 4-11
     for 
    adding circuit packs for packet bus support.
    Add Packet Bus Support
    1. If p ac ket b us sup p ort is not alread y installed , see ‘‘Add Packet Bus 
    Support’’ on page 4-11 and  p erform the step s.
    Add Circuit Packs
    1. Determine port assig nment of c irc uit p ac ks to be ad d ed .
    2. Install the DS1 Interfac e c irc uit p ac k in the assig ned c arrier slot.
    3. Install a Tone Detec tor c irc uit p ac k if req uired . 
    						
    							DEFINITY ECS Release 8.2 Installation, Upgrades, 
    and Additions for Compact Modular Cabinets  555-233-118  Issue 1
    April 2000
    Adding or Removing Hardware 
    4-11 Add Packet Bus Support 
    4
    Install Cables
    1. Install c ab les from the TN464F to the MDF as req uired .
    Enter Added Translations
    1.Ad minister the forms listed  und er “ Integ rated  Servic es Dig ital Network — 
    Primary Rate Interfac e”  in DEFINITY Enterp rise Communic ations Server 
    Release 8 Ad ministrator’s Guid e.
    Resolve Alarms
    1. Examine the alarm log. Resolve any alarms that may exist using  D EFI N I TY 
    Enterp rise Communic ations Server Release 8 Maintenanc e for R8c si. 
    Save Translations
    1. Type save translation
     and press En te r. This instruc ts the system to take all 
    translation information in memory and  write it to the translation c ard s.
    2. Up d ate b ac kup  c ard s, if nec essary.
    Add Packet Bus Support
    Disable Alarm Origination
    1. Type change system-parameters maintenance
     and press En t e r. 
    2. Set the Alarm Origination Activated
     field  to n
    .
    !CAUTION:
    If you d o not d isab le Alarm Orig ination, the system may g enerate 
    alarms, resulting  in unnec essary troub le tic kets. 
    3. For some releases of software, disab le Cleared Alarm Notification
     
    and  Restart Notification
     b efore sub mitting  the form.
    Save Translations
    1. Type save translation
     and press En te r. This instruc ts the system to take all 
    translation information in memory and  write it to the translation c ard . 
    						
    							DEFINITY ECS Release 8.2 Installation, Upgrades, 
    and Additions for Compact Modular Cabinets  555-233-118  Issue 1
    April 2000
    Adding or Removing Hardware 
    4-12 Add Packet Bus Support 
    4
    Install Circuit Packs
    1. Install the ap p rop riate c irc uit pac ks. See Table 4-2.
    Administer the Bus Bridge
    1. Type change system-parameters maintenance
     and press En t e r.
    2. On Page 2, Type y
     in the PKTINT 2 
    field .
    3. Choose the p ort b and wid ths or use the d efault and  sub mit the form.
    4. Verify the bus brid ge LED is lit on the TN799 C-LAN c irc uit p ac k. This 
    indic ates that the p ac ket b us is enab led.
    Test the Packet Bus and C-LAN Circuit Pack
    1. Type test packet port-network 1 long 
    and p ress En t e r. For more 
    d etail ab out these tests, refer to the test p kt c ommand sec tion in the 
    DEFINITY Enterp rise Communic ations Server Release 8 Maintenanc e for 
    R8 c s i .  
    Resolve Alarms
    1. Examine the alarm log . Resolve any alarms using  DEFINITY Enterp rise 
    Communic ations Server Release 8 Maintenanc e for R8c si. 
    Enable Customer Options and Alarm Origination
    1. Get the DOSS order number of the upgrade from the project manager and 
    ask the reg ional Customer Software Ad ministration to c omp lete the step s 
    in the shad ed  b ox. See ‘‘Where to Call for Tec hnic al Sup p ort’’ on p ag e -xix
     
    for telep hone numb ers.
    NOTE:
    As p art of the system reg istration p roc ess, the INADS Datab ase 
    Ad ministrator enab les Alarm Orig ination.
    2. When ad ministration is c omp leted , log  in as craft
     at the Login:
     prompt.
    Table 4-2. Circuit Pack Locations for Packet Bus in PPN
    Circuit Pack Carrier Quantity Slot
    TN799 Any 11 Any Availab le Port Slot 
    						
    							DEFINITY ECS Release 8.2 Installation, Upgrades, 
    and Additions for Compact Modular Cabinets  555-233-118  Issue 1
    April 2000
    Adding or Removing Hardware 
    4-13 Add CallVisor ASAI 
    4
    Add CallVisor ASAI
    Enter Added Translations
    1. On the System-Parameters Customer-Op tions sc reen, disab le the Calling  
    Party Numb er/Billing  Numb er (CPN/BN) op tion, and  enab le the CallVisor 
    ASAI Interfac e op tion. 
    2. Enable the Pac ket Bus Activated option on the System-Parameters 
    Maintenanc e sc reen.
    3. See DEFINITY Enterp rise Communic ations Server Release 8 
    Ad ministrator’s Guid e, for d etails on d isab ling  and  enab ling these op tions.
    Save Translations
    1. Type save translation
     and press En te r. This instruc ts the system to take all 
    translation information in memory and  write it to the translation c ard s.
    2. If administered  rec ord ed  announc ements are d isp layed, Typ e list 
    configuration software-version
     and  p ress 
    En t e r. Go to Pag e 2 to see 
    when announc ements were last saved . 
    3. To save the announc ements, Typ e save announcements
     and press 
    En te r.
    init login administration:
    1. Log in as init
    .
    2. Type change system-parameters customer-options
     and press 
    En te r 
    to verify that the c ustomer op tions are p roperly set.
    3. Go to sc reen 6, QSIG Op tional Features, and  set the Basic Call 
    Setup 
    field  to y
     if the customer was using Supplementary Services 
    Protoc ol b  or d  on an ISDN-PRI trunk g roup  b efore the up g rad e.
    4. Type change system-parameters offer-options
     and  p ress 
    En te r.
    5. If the Activate Offer
     field  is n
    , set it to y 
    and press 
    Ta b. A warning  
    messag e lets you know whether you need  to save translations and  
    reb oot to make the c hang e p ermanent.
    6. Press 
    En t e r to effec t the c hang es or Canc el if there were no c hang es.
    7. Contac t the req uester when d one. 
    						
    							DEFINITY ECS Release 8.2 Installation, Upgrades, 
    and Additions for Compact Modular Cabinets  555-233-118  Issue 1
    April 2000
    Adding or Removing Hardware 
    4-14 Add CallVisor ASAI 
    4
    Add Packet Bus Support
    1. If p ac ket b us sup p ort is not alread y installed , see ‘‘Add Packet Bus 
    Support’’ on page 4-11 and  p erform the step s.
    Add Circuit Packs
    1. Determine port assig nment of c irc uit p ac ks to be ad d ed .
    2. Install the ap p rop riate c irc uit pac ks in assigned  c arrier slot (as req uired ).
    The TN744/C/D Call Classifier c irc uit pac k is req uired  for those c ustomers 
    who want switc h c all c lassific ation.
    A vac ant p ort is req uired on a TN556/B/C ISDN—BRI c irc uit pack.
    Install Cables
    1. Install c ab les from TN464F to the MDF as req uired .
    Enter Added Translations
    1. Ad minister the req uired  translation d ata using the forms listed und er 
    “ Ad junc t/Switc h Ap p lic ations Interfac e (ASAI)”  in DEFINITY Enterp rise 
    Communic ations Server Release 8 Ad ministrator’s Guid e.
    Resolve Alarms
    1. Examine the alarm log. Resolve any alarms that may exist using  D EFI N I TY 
    Enterp rise Communic ations Server Release 8 Maintenanc e for R8c si. 
    Save Translations
    1. Type save translation
     and press En te r. This instruc ts the system to take all 
    translation information in memory and  write it to the translation c ard s.
    2. Up d ate b ac kup  translation c ard s, if required . EXAMPLE:
    3A0701
    Cab inet (Port 
    Network)Carrier Slot 
    Numb erPo rt  
    Numb er 
    						
    							DEFINITY ECS Release 8.2 Installation, Upgrades, 
    and Additions for Compact Modular Cabinets  555-233-118  Issue 1
    April 2000
    Adding or Removing Hardware 
    4-15 Add DCS Interface 
    4
    Add DCS Interface
    Systems in a Distrib uted  Communic ations System (DCS) network are 
    interc onnec ted b y b oth tie trunks (for voic e c ommunic ations) and  d ata links (for 
    c ontrol and  transp arent feature information). These d ata links, also c alled  DCS 
    sig naling  links, supp ort the feature transp arenc y. 
    Various sub sets (dep end ing  on the sp ec ific  c onfig uration) of DS1 Interfac e 
    c irc uit p ac ks (inc lud ing TN464C, TN767C, and  TN760) p rovid e the 
    voic e-c ommunic ations interfac e.
    Meanwhile, the d ata link interfac e (b etween the p roc essor and  the p hysic al 
    sig naling  link) is p rovid ed  b y (or throug h) a TN799 Control-LAN c irc uit p ac k. In 
    some c onfig urations, the TN799 passes the sig naling  information over a sep arate 
    10BaseT TCP/IP network (usually via a hub ). For use with 10BaseT, c onnec t the 
    ap p rop riate p ins of the I/O field  to the hub , or use a 259A c onnec tor and  DW8 
    c ab le to c onnec t d irec tly to the d ata-network eq uip ment. For p inouts and  
    d iag rams, refer to the installation manual. In other c onfig urations, the TN799 
    c irc uit p ac k c arries sig naling  over p oint-to-p oint p rotoc ol (PPP) for subseq uent 
    inc lusion (via the switc hing  fab ric ) in the same DS1 b it stream as the DSC voic e 
    transmissions.
    For further information about DCS, refer to the following  d oc uments:
    nAT&T System 75/85 Network and Data Servic es Referenc e Manual
    nSystem 75 Ap p lic ation Notes Network Servic es
    nDEFINITY ECS Release 8 Ad ministration for Network Connec tivity
    Add Circuit Packs
    A TN464C, TN767C, or TN760 DS1 c irc uit p ac k is req uired  for PPP c onnec tions. 
    A TN799 C-LAN c irc uit p ac k is req uired .
    1. Determine the p ort assig nments of the c irc uit p ac ks to b e ad d ed . If a 
    C-LAN c irc uit p ac k is already in the system, you do not need  a sec ond  
    C-LAN c irc uit p ac k for DCS. If your system alread y has a C-LAN, skip  the 
    following  ‘‘Administer the Bus Bridge’’
     sec tion. You d o not need to p ower 
    d own the c ab inet to install any of these c irc uit p ac ks. 
    Administer the Bus Bridge
    1. Type change system-parameters maintenance
     and press En t e r. 
    2. On Page 2, Type y
     in the PKTINT 2 
    field .
    3. Choose the p ort b and wid ths or use the d efault and  sub mit the form.
    4. Verify the bus brid ge LED is lit on the Control-LAN c irc uit p ac k. This 
    indic ates that the p ac ket b us is enab led. 
    						
    							DEFINITY ECS Release 8.2 Installation, Upgrades, 
    and Additions for Compact Modular Cabinets  555-233-118  Issue 1
    April 2000
    Adding or Removing Hardware 
    4-16 Add DCS Interface 
    4
    Test the Packet Bus and Control-LAN 
    Circuit Pack
    1. Type test packet port-network 1 long 
    and p ress En t e r. For more d etail 
    ab out these tests, refer to the “ test p kt c ommand ”  sec tion in the 
    maintenanc e b ook. 
    Install Cables
    1. Install c ab le from the c ab inet to a hub  or 110 (p urp le) wall field  as 
    req uired. Connec t the 259A c onnec tor to the p ort slot c ontaining the 
    C-LAN c irc uit p ac k. See Figure 4-2
    . For a p inout of TN799, see Table 4-3. 
    Figure 4-2. Cable Connection for C-LAN  Figure Notes
    1. 259A Connec tor
    2. DW8 Cab le3. Hub  or 110 (p urp le) wall field
    1
    3
    cydflan3  KLC 032999
    2 
    						
    							DEFINITY ECS Release 8.2 Installation, Upgrades, 
    and Additions for Compact Modular Cabinets  555-233-118  Issue 1
    April 2000
    Adding or Removing Hardware 
    4-17 Add ISDN—BRI 
    4
    Enter Added Translations
    1. Get the DOSS order numb er of the upg rad e. Call the reg ional CSA to 
    p erform the step s in this sec tion.
    2. To enab le DCS, set the DCS
     field  on the System Parameters-Customer 
    Options form to y
    .
    3. Ad minister the other req uired  translation data using  the forms listed  und er 
    Distrib uted  Communic ations System (DCS) in DEFINITY Communic ations 
    System Administration for Networking  Connec tivity. 
    Save Translations
    1. Type save translation 
    and press En te r to instruc t the system to c op y the 
    translation information to the flashc ard .
    Add ISDN—BRI
    Add the Packet Bus Support
    1. If p ac ket b us sup p ort is not alread y installed , see ‘‘Add Packet Bus 
    Support’’ on page 4-11 and  p erform the step s.
    Table 4-3. TN799 Pinout
    Backplane Pin 25-Pair Wire Color Lead NamePeripheral 
    Connector Pin
    103 White/Orang e TD+ 27
    003 Orang e/White TD- 2
    104 White/Green RD+ 28
    004 Green/White RD- 3 
    						
    							DEFINITY ECS Release 8.2 Installation, Upgrades, 
    and Additions for Compact Modular Cabinets  555-233-118  Issue 1
    April 2000
    Adding or Removing Hardware 
    4-18 Add IP Interface Assembly 
    4
    Add Circuit Packs
    1. Determine port assig nment of c irc uit p ac ks to be ad d ed .
    2. Install the ap p rop riate c irc uit pac ks in assigned  c ab inet slot (as req uired ).
    Install Cables
    1. Install c ab les from c ab inet to the MDF as req uired .
    NOTE:
    BRI req uires a 12-p ort b ac kp lane c ab le terminator (b reakout 
    c onnec tor). Connec t this terminator to the 25-p air c ab le. This is 
    d ifferent from the 8-p ort c onnec tor used  for DCP.
    Enter Added Translations
    1. Ad minister the req uired  translation d ata using the forms listed und er 
    7500D voic e terminals and  8500 voic e terminals in DEFINITY Enterp rise 
    Communic ations Server Release 8 Ad ministrator’s Guid e.
    Resolve Alarms
    1. Examine the alarm log . Resolve any alarms using  DEFINITY Enterp rise 
    Communic ations Server Release 8 Maintenanc e for R8c si. 
    Save Translations
    1. Type save translation
     and press En te r to instruc t the system c op y 
    translation information to the translation flashc ard s
    2. Update backup cards, if required.
    Add IP Interface Assembly
    DEFINITY ECS IP Solutions allows you to send  voic e and  fax from the DEFINITY 
    ECS throug h an Internet p rotoc ol (IP) network to other DEFINITY ECSs having  
    this feature or to other H.323 V2 c omp liant end p oints. It is imp lemented  using  the 
    TN802/B IP Interfac e, whic h is a Wind ows NT server resid ing  on the IP Interfac e 
    Assemb ly insid e the DEFINITY ECS.EXAMPLE:
    3A0701
    Cab inet (Port 
    Network)Carrier Slot 
    Numb erPo rt  
    Numb er 
    						