Have a look at the manual Lucent Technologies DEFINITY Enterprise Communication Server Release 8.2 Installation, Upgrades, And Additions For Compact Modular Cabinets Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 413 Lucent Technologies manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.
DEFINITY ECS Release 8.2 Installation, Upgrades, and Additions for Compact Modular Cabinets 555-233-118 Issue 1 April 2000 Upgrading R6csi/R7csi to R8csi 3-15 DEFINITY AUDIX Power Procedures 3 nIf the AUDIX remained in the c ab inet and the c ab inet was not p owered down: 1. At the AUDIX c onsole, hold the crtl key and enter cc . 2. Enter 5 at the p romp t. In ab out 2 minutes, the AUDIX b oots up . 3. When the system initialization is c omp lete, log in as craft . 4. Check for AUDIX System errors.
DEFINITY ECS Release 8.2 Installation, Upgrades, and Additions for Compact Modular Cabinets 555-233-118 Issue 1 April 2000 Upgrading R6csi/R7csi to R8csi 3-16 DEFINITY AUDIX Power Procedures 3
Adding or Removing Hardware 4-1 Add Circuit Packs 4 DEFINITY ECS Release 8.2 Installation, Upgrades, and Additions for Compact Modular Cabinets 555-233-118 Issue 1 April 2000 4 Adding or Removing Hardware This c hapter d etails the information req uired to install ad ditional p ort hard ware assoc iated with up g rad ing an existing system. For more information about installing ad junc ts and p erip heral d evic es, refer to DEFINITY Enterp rise Communic ations Server Release 8 Installation for Ad junc ts and Perip herals. Add Circuit Packs When installing additional features or equipment, it may be necessary to install ad d itional c irc uit p ac ks. To see a list of allowab le c irc uit p ac ks, see ‘‘Allowable Circuit Packs for CMC’’ on page 1-31. This is a g eneral p roc ed ure to use when ad d ing features or eq uip ment that req uire ad d ing c irc uit p ac ks. 1. Log onto the system and answer y to the Sup p ress Alarm Orig ination q uestion d uring log in. 2. Install the c irc uit p ac k into the c arrier. 3. Type change circuit-pack . 4. Verify the c irc uit p ac k app ears in the listing . 5. If the c irc uit p ac k c ode is not p resent, typ e the c od e manually in the p rop er slot. 6. Type test board long and press En t e r to test the b oard . 7. Log off the system after the ad dition (and any req uired ad ministration) is complete. For information ab out ad ministering c irc uit p ac ks and other eq uip ment, refer to DEFINITY Enterp rise Communic ations Server Release 8 Ad ministrator’s Guid e.
DEFINITY ECS Release 8.2 Installation, Upgrades, and Additions for Compact Modular Cabinets 555-233-118 Issue 1 April 2000 Adding or Removing Hardware 4-2 Add CO, FX, WATS, and PCOL 4 Add CO, FX, WATS, and PCOL Requirements Eac h Central Offic e (CO), Foreign Exc hang e (FX), Personal Central Offic e Line (PCOL), or Wid e Area Telec ommunic ations Servic e (WATS) trunk c onnec ts to 1 p ort of either an 8-p ort TN747B or to 1 of several CO trunk c irc uit p ac ks. Installation 1. Install a TN747B or a CO Trunk c irc uit p ac k in the assig ned c arrier slot (if an ad d itional c irc uit p ac k is req uired ). 2. Ad minister the forms listed und er CO, FX, WATS, or PCOL Trunk Group in DEFINITY Enterp rise Communic ations Server Release 8 Ad ministrator’s Guid e. 3. Determine the p ort assig nment of the trunk from the Trunk Group form. Add DID Trunks Requirements Eac h Direc t Inward Dial (DID) trunk c onnec ts to 1 port DID Trunk c irc uit p ac k or to 1 p ort of an assortment of DID trunk c irc uit pac ks. Installation 1. Determine the p ort assig nment of the trunk from the Trunk Group form. 2. Install a DID Trunk c irc uit p ac k in assig ned c arrier slot (if an ad d itional c irc uit p ac k is req uired ). 3.Ad minister forms listed under “ DID Trunk Group ” in D EFINITY En terp ris e Communic ations Server Release 8 Ad ministrator’s Guid e. EXAMPLE: 3A0701 Cab inet (Port Network)Carrier Slot Numb erPo rt Numb er EXAMPLE: 3A0701 Cab inet (Port Network)Carrier Slot Numb erPo rt Numb er
DEFINITY ECS Release 8.2 Installation, Upgrades, and Additions for Compact Modular Cabinets 555-233-118 Issue 1 April 2000 Adding or Removing Hardware 4-3 Add Tie Trunks 4 Add Tie Trunks Requirements Eac h tie trunk c onnec ts to 1 p ort of a 4-p ort tie trunk c irc uit pac k or to an assortment of international tie trunk c irc uit p ac ks. Installation 1. Determine the p ort assig nment of the trunk from the trunk g roup sc reen. 2. Install the tie trunk or an international tie trunk c irc uit p ac k in assig ned c arrier slot (if an ad d itional c irc uit p ac k is req uired ). 3. For c ustomer-owned (not leased ) tie-trunk fac ilities (suc h as c amp us environments), tie trunk c irc uit p ac ks p rovid e sig naling c apab ilities b eyond those sp ec ified b y the ind ustry-wid e E&M stand ard . Use Figure 4-1 and Table 4-1 to c hoose the p referred sig naling format, set switc hes on the c irc uit p ac k, and ad minister the p ort. 4.Ad minister forms listed under “ Tie Trunk Group ” in the DEFINITY Enterp rise Communic ations Server Release 8 Ad ministrator’s Guid e. EXAMPLE: 3A0701 Cab inet (Port Network)Carrier Slot Numb erPo rt Numb er
DEFINITY ECS Release 8.2 Installation, Upgrades, and Additions for Compact Modular Cabinets 555-233-118 Issue 1 April 2000 Adding or Removing Hardware 4-4 Add Tie Trunks 4 Figure 4-1. Tie Trunk Circuit Packs (Component Side) Table 4-1. Tie Trunk Option-Switch Settings and Administration Installation Situation Preferred Signaling FormatE&M/SMPLX SwitchProt/Unprot SwitchAdministered Port Circumstance To System Far-End Colloc ated DEFINITY E&M Typ e 1 E&M Typ e 1 E&M Unp rotec ted Typ e 1 Comp atib le Stand ard Compatib le Inter-Build ing DEFINITY Protec ted Ty p e 1Protec ted Typ e 1E&M Protec ted Typ e 1 Comp atib le Stand ard Pl u sCompatib le Protec tion Unit Colloc ated Net Integ rated E&M Typ e 1 Any PBX E&M Unp rotec ted Typ e 1 Stand ard 4321 PORT 4 PORT 3PORT 2PORT 1 UNPROT PROTSMPLX E&M SMPLX E&MSMPLX E&MSMPLX E&M r758183 RBP 050896
DEFINITY ECS Release 8.2 Installation, Upgrades, and Additions for Compact Modular Cabinets 555-233-118 Issue 1 April 2000 Adding or Removing Hardware 4-5 Add DS1 Tie and OPS 4 Add DS1 Tie and OPS The TN2313 DS1 Tie Trunk and TN767B (or later) DS1 Interfac e c irc uit p ac ks p rovid e c onnec tions to a 1.544-Mb p s DS1 fac ility (T1) as 24 ind ep end ent 64-kb p s trunks. The TN2313 DS1 Tie Trunk, TN767B (or later) DS1 Interfac e, and TN464C (or later) DS1 Interfac e c irc uit p ac ks p rovide c onnec tions to a 2.048-Mb p s DS1 fac ility (E1) as 32 ind ep end ent 64-kb p s trunks. Service Interruption 1. Sinc e the ad d ition of DS1 tie-trunk servic e may req uire a servic e interrup tion, notify the c ustomer in ad vanc e as to when the ad d ition will oc c ur. 2. For information ab out ad ministering DS1 Tie Trunks, refer to DEFINITY Enterp rise Communic ations Server Release 8 Ad ministrator’s Guid e. Add Speech Synthesis The Sp eec h Synthesizer c irc uit p ac k is req uired when the Voic e Messag e Retrieval, Automatic Wakeup , or Do Not Disturb features are ac tivated . The c irc uit p ac k does not req uire ad ministration. 1. Determine the p ort assig nment of the Sp eec h Synthesizer c irc uit p ac k being added. 2. Install the Sp eec h Synthesizer c irc uit p ac k in the d esig nated c arrier slot. Add Code Calling Access The tones for the Cod e Calling feature are g enerated b y the Tone-Cloc k c irc uit p acks in the port networks. 1. Install an Auxiliary Trunk c irc uit p ac k or a Sp eec h Synthesizer c irc uit p ac k and c onnec t for Loud sp eaker Pag ing . The Cod e Calling Ac c ess feature shares the same p orts as Loudsp eaker Pag ing . An Auxiliary Trunk c irc uit pack provides 4 ports for Loudspeaker Paging and Code Calling Access. 2.Ad minister the form listed und er “ Cod e Calling Ac c ess” in DEFINITY Enterp rise Communic ations Server Release 8 Ad ministrator’s Guid e.
DEFINITY ECS Release 8.2 Installation, Upgrades, and Additions for Compact Modular Cabinets 555-233-118 Issue 1 April 2000 Adding or Removing Hardware 4-6 Add Pooled Modem 4 Add Pooled Modem Modem pooling supports two types of conversion resources: integrated and combined. An integ rated c onversion requires a Pooled Mod em c irc uit p ac k for eac h 2 c onversion resourc es p rovid ed. A c omb ined c onversion requires a p ort of a TN745B or TN2136 Dig ital Line c irc uit p ac k and a p ort of either an 8-p ort TN742, TN769, a 16-p ort TN746B, or a 24-p ort TN793/B, TN2793/B Analog Line c irc uit p ac k for eac h c onversion resourc e provid ed . The p ooled mod em req uires a Luc ent WP90110 L7 p ower sup p ly. Althoug h integ rated c onversion c an use either the L5 or L7, the c omb ined only works with an L7. !CAUTION: The L5 and L7 p ower sup p lies look id entic al. Chec k the lab el to b e sure you have the L7 b efore installing . Determine the port assignment of the circuit packs to be added (if required). 3. Install the ap p rop riate c irc uit pac ks in assigned c arrier slot (if req uired ). 4. For Paradyne 3800 series mod ems: a. Type AT&F&D2&S4\D3S2=128x7V2S7=60S85=1 and p ress En te r. b. Type ATY0S10=100S78=2M0E0\N1&W and p ress En t e r. 5.For other typ es of mod ems, refer to the vend or’s d oc umentation. Settings for Modem Connected to Data Module 1. Type add data-module next and press En t e r. 2. Type pdm in the Type field . 3. Type x in the Port field. 4. Type dte in the Connected to field and press En te r. 5. Type add station next and press En t e r. 6. Type 2500 in the Type field. 7. Type x in the Port field. 8. Type n in the Tests field and p ress En te r. 9. Type add modem-pool next and p ress En te r.
DEFINITY ECS Release 8.2 Installation, Upgrades, and Additions for Compact Modular Cabinets 555-233-118 Issue 1 April 2000 Adding or Removing Hardware 4-7 Add Multiple Integrated Recorded Announcement 4 10. Typ e combined in the Group Type field. 11. Typ e 5 in the Hold Time (min) field . 12. Typ e two-way in the Direction field . 13. Typ e 9600 in the Speed field. 14. Typ e Full in the Duplex field . 15. Typ e async in the Synchronization field . 16. Typ e the p ort p air assig nments in the Analog and Digital fields and p ress En t e r. Settings for Modem Connected to the Data Terminal Equipment (DTE) 1. Type add station next and press En t e r. 2. Type 2500 in the Type field. 3. Typ e the p ort assig nment in the Port field and p ress En t e r. Add Multiple Integrated Recorded Announcement TN750C c irc uit p ac ks are req uired if the system has multiple announc ement c irc uit p ac ks. Up to 5 TN750Cs are allowed in a Release 7 or later. The announc ements from a TN750 or TN750B c an b e c op ied to a TN750C. !CAUTION: Do not c op y or restore announc ements from a TN750C to a TN750 or TN750B c irc uit p ac k, as this p roc ess may c orrupt the announc ement d ata. 1. Install the TN750C c irc uit pac k into any p ort slot. NOTE: Only 1 TN750 or TN750B c an reside in the system with a TN750C. The TN750C need not resid e in a c ontrol c arrier for extra p ower hold over. TN750C Announcement Circuit Pack The TN750C c irc uit p ac k c ontains on-b oard flash memory that p rovides internal b ac kup of announc ements. Thus, the TN750C c irc uit p ac k d oes not need the save and restore p roc esses.
DEFINITY ECS Release 8.2 Installation, Upgrades, and Additions for Compact Modular Cabinets 555-233-118 Issue 1 April 2000 Adding or Removing Hardware 4-8 Add Multiple Integrated Recorded Announcement 4 The TN750C c irc uit p ac k c an rep lac e a TN750 or TN750B. The d ifferenc e in op eration is that the TN750C automatic ally restores and rep orts the availab ility of announc ements from its own internal flash memory in 5 minutes, rather than the 40 minutes for the TN750 or TN750B. If a c irc uit p ac k alread y has announc ements in its flash memory, the yellow LED flashes as the announc ements c op y to the voic e RAM. Save and Restore Recorded Announcements !CAUTION: If the yellow LED is flashing , d o not remove the c irc uit p ac k, as this will c orrup t the announc ement d ata. 1. Type save announcements and p ress En t e r. 2. To restore announc ements, typ e restore announcements to and p ress En t e r. After 5 minutes (with no alterations to the announc ements), the TN750C automatic ally c op ies the announc ements from the voic e RAM to the internal flash memory. The yellow LED on the front of the TN750C flashes. You c an only save the announc ement c ontents of 1 c irc uit p ac k at a time. For the c ontents of every c irc uit p ac k, save to sep arate translation c ard s. Lab el eac h translation c ard so that it matc hes the c irc uit p ac k. TN750 and TN750B Announcement Circuit Packs To save the rec ord ed announc ements in the system, typ e save announcements and p ress En t e r. Use these c od es after b usiness hours or when the system is op erating d uring a low-usage p eriod. The system takes ab out 40 minutes to transfer the rec ord ed announc ements from the announc ement c irc uit p ac k to the translation c ard . During this time, the manag ement terminal c annot b e used to ad minister the system; however, all other ad ministration terminals, if p rovid ed, are allowed to p erform ad ministration p roc ed ures. Ty p e restore announcements and press En te r to restore the rec ord ed announc ements from the translation c ard to system memory.