    Have a look at the manual Lucent Technologies DEFINITY Enterprise Communication Server Release 8.2 Installation, Upgrades, And Additions For Compact Modular Cabinets Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 413 Lucent Technologies manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.

    							DEFINITY ECS Release 8.2 Installation, Upgrades, 
    and Additions for Compact Modular Cabinets  555-233-118  Issue 1
    April 2000
    Upgrading R6csi/R7csi to R8csi 
    3-15 DEFINITY AUDIX Power Procedures 
    3
    nIf the AUDIX remained in the c ab inet and  the c ab inet was not p owered  
    down:
    1. At the AUDIX c onsole, hold  the 
    crtl key and  enter cc
    .
    2. Enter 5
     at the p romp t. In ab out 2 minutes, the AUDIX b oots up .
    3. When the system initialization is c omp lete, log  in as craft
    .
    4. Check for AUDIX System errors.  
    						
    							DEFINITY ECS Release 8.2 Installation, Upgrades, 
    and Additions for Compact Modular Cabinets  555-233-118  Issue 1
    April 2000
    Upgrading R6csi/R7csi to R8csi 
    3-16 DEFINITY AUDIX Power Procedures 
    3 
    						
    							Adding or Removing Hardware 
    4-1 Add Circuit Packs 
    4
    DEFINITY ECS Release 8.2 Installation, Upgrades, 
    and Additions for Compact Modular Cabinets  555-233-118  Issue 1
    April 2000
    4
    Adding or Removing Hardware
    This c hapter d etails the information req uired  to install ad ditional p ort hard ware  
    assoc iated  with up g rad ing  an existing  system. 
    For more information about installing  ad junc ts and  p erip heral d evic es, refer to 
    DEFINITY Enterp rise Communic ations Server Release 8 Installation for Ad junc ts 
    and  Perip herals.
    Add Circuit Packs
    When installing additional features or equipment, it may be necessary to install 
    ad d itional c irc uit p ac ks. To see a list of allowab le c irc uit p ac ks, see ‘‘Allowable 
    Circuit Packs for CMC’’ on page 1-31. This is a g eneral p roc ed ure to use when 
    ad d ing  features or eq uip ment that req uire ad d ing c irc uit p ac ks.
    1. Log  onto the system and  answer y
     to the Sup p ress Alarm Orig ination 
    q uestion d uring  log in.
    2. Install the c irc uit p ac k into the c arrier.
    3. Type change circuit-pack
    .
    4. Verify the c irc uit p ac k app ears in the listing .
    5. If the c irc uit p ac k c ode is not p resent, typ e the c od e manually in the 
    p rop er slot.
    6. Type test board long
     and  press 
    En t e r to test the b oard .
    7. Log  off the system after the ad dition (and  any req uired  ad ministration) is 
    complete.
    For information ab out ad ministering c irc uit p ac ks and  other eq uip ment, refer to 
    DEFINITY Enterp rise Communic ations Server Release 8 Ad ministrator’s Guid e. 
    						
    							DEFINITY ECS Release 8.2 Installation, Upgrades, 
    and Additions for Compact Modular Cabinets  555-233-118  Issue 1
    April 2000
    Adding or Removing Hardware 
    4-2 Add CO, FX, WATS, and PCOL 
    4
    Add CO, FX, WATS, and PCOL
    Requirements
    Eac h Central Offic e (CO), Foreign Exc hang e (FX), Personal Central Offic e Line 
    (PCOL), or Wid e Area Telec ommunic ations Servic e (WATS) trunk c onnec ts to 1 
    p ort of either an 8-p ort TN747B or to 1 of several CO trunk c irc uit p ac ks. 
    Installation
    1. Install a TN747B or a CO Trunk c irc uit p ac k in the assig ned  c arrier slot (if 
    an ad d itional c irc uit p ac k is req uired ).
    2. Ad minister the forms listed  und er CO, FX, WATS, or PCOL Trunk Group  in 
    DEFINITY Enterp rise Communic ations Server Release 8 Ad ministrator’s 
    Guid e.
    3. Determine the p ort assig nment of the trunk from the Trunk Group  form.
    Add DID Trunks
    Requirements
    Eac h Direc t Inward  Dial (DID) trunk c onnec ts to 1 port DID Trunk c irc uit p ac k or 
    to 1 p ort of an assortment of DID trunk c irc uit pac ks.
    Installation
    1. Determine the p ort assig nment of the trunk from the Trunk Group  form.
    2. Install a DID Trunk c irc uit p ac k in assig ned  c arrier slot (if an ad d itional 
    c irc uit p ac k is req uired ).
    3.Ad minister forms listed  under “ DID Trunk Group ”  in D EFINITY En terp ris e 
    Communic ations Server Release 8 Ad ministrator’s Guid e. EXAMPLE:
    3A0701
    Cab inet (Port 
    Network)Carrier Slot 
    Numb erPo rt  
    Numb er
    EXAMPLE:
    3A0701
    Cab inet (Port 
    Network)Carrier Slot 
    Numb erPo rt  
    Numb er 
    						
    							DEFINITY ECS Release 8.2 Installation, Upgrades, 
    and Additions for Compact Modular Cabinets  555-233-118  Issue 1
    April 2000
    Adding or Removing Hardware 
    4-3 Add Tie Trunks 
    4
    Add Tie Trunks
    Requirements
    Eac h tie trunk c onnec ts to 1 p ort of a 4-p ort tie trunk c irc uit pac k or to an 
    assortment of international tie trunk c irc uit p ac ks.
    Installation
    1. Determine the p ort assig nment of the trunk from the trunk g roup  sc reen.
    2. Install the tie trunk or an international tie trunk c irc uit p ac k in assig ned  
    c arrier slot (if an ad d itional c irc uit p ac k is req uired ).
    3. For c ustomer-owned  (not leased ) tie-trunk fac ilities (suc h as c amp us 
    environments), tie trunk c irc uit p ac ks p rovid e sig naling  c apab ilities 
    b eyond  those sp ec ified  b y the ind ustry-wid e E&M stand ard . Use Figure 
    4-1 and Table 4-1 to c hoose the p referred  sig naling  format, set switc hes 
    on the c irc uit p ac k, and  ad minister the p ort.
    4.Ad minister forms listed  under “ Tie Trunk Group ”  in the DEFINITY 
    Enterp rise Communic ations Server Release 8 Ad ministrator’s Guid e. EXAMPLE:
    3A0701
    Cab inet (Port 
    Network)Carrier Slot 
    Numb erPo rt  
    Numb er 
    						
    							DEFINITY ECS Release 8.2 Installation, Upgrades, 
    and Additions for Compact Modular Cabinets  555-233-118  Issue 1
    April 2000
    Adding or Removing Hardware 
    4-4 Add Tie Trunks 
    4
    Figure 4-1. Tie Trunk Circuit Packs (Component Side)
    Table 4-1. Tie Trunk Option-Switch Settings and Administration
    Installation Situation Preferred Signaling FormatE&M/SMPLX 
    SwitchProt/Unprot 
    SwitchAdministered
    Port
    Circumstance To System Far-End
    Colloc ated DEFINITY E&M Typ e 1 E&M Typ e 1 E&M Unp rotec ted Typ e 1
    Comp atib le Stand ard Compatib le
    Inter-Build ing DEFINITY Protec ted  
    Ty p e  1Protec ted 
    Typ e 1E&M Protec ted Typ e 1
    Comp atib le Stand ard 
    Pl u sCompatib le
    Protec tion
    Unit
    Colloc ated Net Integ rated E&M Typ e 1 Any PBX E&M Unp rotec ted Typ e 1
    Stand ard
    4321
    PORT 4 PORT 3PORT 2PORT 1 UNPROT
    PROTSMPLX
    E&M
    SMPLX
    E&MSMPLX
    E&MSMPLX
    E&M
    r758183 RBP 050896 
    						
    							DEFINITY ECS Release 8.2 Installation, Upgrades, 
    and Additions for Compact Modular Cabinets  555-233-118  Issue 1
    April 2000
    Adding or Removing Hardware 
    4-5 Add DS1 Tie and OPS 
    4
    Add DS1 Tie and OPS
    The TN2313 DS1 Tie Trunk and  TN767B (or later) DS1 Interfac e c irc uit p ac ks 
    p rovid e c onnec tions to a 1.544-Mb p s DS1 fac ility (T1) as 24 ind ep end ent 
    64-kb p s trunks. 
    The TN2313 DS1 Tie Trunk, TN767B (or later) DS1 Interfac e, and  TN464C (or 
    later) DS1 Interfac e c irc uit p ac ks p rovide c onnec tions to a 2.048-Mb p s DS1 
    fac ility (E1) as 32 ind ep end ent 64-kb p s trunks.
    Service Interruption
    1. Sinc e the ad d ition of DS1 tie-trunk servic e may req uire a servic e 
    interrup tion, notify the c ustomer in ad vanc e as to when the ad d ition will 
    oc c ur.
    2. For information ab out ad ministering DS1 Tie Trunks, refer to DEFINITY 
    Enterp rise Communic ations Server Release 8 Ad ministrator’s Guid e.
    Add Speech Synthesis
    The Sp eec h Synthesizer c irc uit p ac k is req uired  when the Voic e Messag e 
    Retrieval, Automatic  Wakeup , or Do Not Disturb  features are ac tivated . The 
    c irc uit p ac k does not req uire ad ministration.
    1. Determine the p ort assig nment of the Sp eec h Synthesizer c irc uit p ac k 
    being added.
    2. Install the Sp eec h Synthesizer c irc uit p ac k in the d esig nated  c arrier slot.
    Add Code Calling Access
    The tones for the Cod e Calling  feature are g enerated  b y the Tone-Cloc k c irc uit 
    p acks in the port networks.
    1. Install an Auxiliary Trunk c irc uit p ac k or a Sp eec h Synthesizer c irc uit p ac k 
    and  c onnec t for Loud sp eaker Pag ing . The Cod e Calling  Ac c ess feature 
    shares the same p orts as Loudsp eaker Pag ing . An Auxiliary Trunk c irc uit 
    pack provides 4 ports for Loudspeaker Paging and Code Calling Access.
    2.Ad minister the form listed  und er “ Cod e Calling  Ac c ess”  in DEFINITY 
    Enterp rise Communic ations Server Release 8 Ad ministrator’s Guid e. 
    						
    							DEFINITY ECS Release 8.2 Installation, Upgrades, 
    and Additions for Compact Modular Cabinets  555-233-118  Issue 1
    April 2000
    Adding or Removing Hardware 
    4-6 Add Pooled Modem 
    4
    Add Pooled Modem
    Modem pooling supports two types of conversion resources: integrated and 
    combined. 
    An integ rated  c onversion requires a Pooled  Mod em c irc uit p ac k for eac h 2 
    c onversion resourc es p rovid ed.
    A c omb ined  c onversion requires a p ort of a TN745B or TN2136 Dig ital Line 
    c irc uit p ac k and  a p ort of either an 8-p ort TN742, TN769, a 16-p ort TN746B, or a 
    24-p ort TN793/B, TN2793/B Analog  Line c irc uit p ac k for eac h c onversion 
    resourc e provid ed . 
    The p ooled  mod em req uires a Luc ent WP90110 L7 p ower sup p ly. Althoug h 
    integ rated  c onversion c an use either the L5 or L7, the c omb ined  only works with 
    an L7.
    !CAUTION:
    The L5 and  L7 p ower sup p lies look id entic al. Chec k the lab el to b e sure you 
    have the L7 b efore installing .
    Determine the port assignment of the circuit packs to be added (if required).
    3. Install the ap p rop riate c irc uit pac ks in assigned  c arrier slot (if req uired ).
    4. For Paradyne 3800 series mod ems:
    a. Type AT&F&D2&S4\D3S2=128x7V2S7=60S85=1
     and  p ress 
    En te r. 
    b. Type ATY0S10=100S78=2M0E0\N1&W
     and  p ress 
    En t e r.
    5.For other typ es of mod ems, refer to the vend or’s d oc umentation.
    Settings for Modem Connected to Data Module
    1. Type add data-module next
     and press En t e r.
    2. Type pdm
     in the Type
     field .
    3. Type x
     in the Port
     field.
    4. Type dte
     in the Connected to
     field and press 
    En te r.
    5. Type add station next
     and press 
    En t e r.
    6. Type 2500
     in the Type
     field.
    7. Type x
     in the Port
     field.
    8. Type n
     in the Tests
     field  and  p ress 
    En te r.
    9. Type add modem-pool next
     and  p ress 
    En te r. 
    						
    							DEFINITY ECS Release 8.2 Installation, Upgrades, 
    and Additions for Compact Modular Cabinets  555-233-118  Issue 1
    April 2000
    Adding or Removing Hardware 
    4-7 Add Multiple Integrated Recorded Announcement 
    4
    10. Typ e combined
     in the Group Type
     field.
    11. Typ e 5
     in the Hold Time (min)
     field .
    12. Typ e two-way
     in the Direction
     field .
    13. Typ e 9600
     in the Speed
     field.
    14. Typ e Full
     in the Duplex
     field .
    15. Typ e async
     in the Synchronization
     field .
    16. Typ e the p ort p air assig nments in the Analog
     and Digital
     fields and  
    p ress 
    En t e r.
    Settings for Modem Connected to the Data
    Terminal Equipment (DTE)
    1. Type add station next
     and press En t e r.
    2. Type 2500
     in the Type
     field.
    3. Typ e the p ort assig nment in the Port
     field  and  p ress 
    En t e r.
    Add Multiple Integrated Recorded 
    Announcement
    TN750C c irc uit p ac ks are req uired  if the system has multiple announc ement 
    c irc uit p ac ks. Up  to 5 TN750Cs are allowed  in a Release 7 or later. The 
    announc ements from a TN750 or TN750B c an b e c op ied  to a TN750C. 
    !CAUTION:
    Do not c op y or restore announc ements from a TN750C to a TN750 or 
    TN750B c irc uit p ac k, as this p roc ess may c orrupt the announc ement d ata.
    1. Install the TN750C c irc uit pac k into any p ort slot. 
    NOTE:
    Only 1 TN750 or TN750B c an reside in the system with a TN750C. 
    The TN750C need  not resid e in a c ontrol c arrier for extra p ower 
    hold over.
    TN750C Announcement Circuit Pack
    The TN750C c irc uit p ac k c ontains on-b oard  flash memory that p rovides internal 
    b ac kup  of announc ements. Thus, the TN750C c irc uit p ac k d oes not need  the 
    save and  restore p roc esses. 
    						
    							DEFINITY ECS Release 8.2 Installation, Upgrades, 
    and Additions for Compact Modular Cabinets  555-233-118  Issue 1
    April 2000
    Adding or Removing Hardware 
    4-8 Add Multiple Integrated Recorded Announcement 
    4
    The TN750C c irc uit p ac k c an rep lac e a TN750 or TN750B. The d ifferenc e in 
    op eration is that the TN750C automatic ally restores and  rep orts the availab ility of 
    announc ements from its own internal flash memory in 5 minutes, rather than the 
    40 minutes for the TN750 or TN750B.
    If a c irc uit p ac k alread y has announc ements in its flash memory, the yellow LED 
    flashes as the announc ements c op y to the voic e RAM. 
    Save and Restore Recorded Announcements
    !CAUTION:
    If the yellow LED is flashing , d o not remove the c irc uit p ac k, as this will 
    c orrup t the announc ement d ata.
    1. Type save announcements
         and  p ress 
    En t e r. 
    2. To restore announc ements, typ e restore announcements
      to     and  p ress 
    En t e r.
    After 5 minutes (with no alterations to the announc ements), the TN750C 
    automatic ally c op ies the announc ements from the voic e RAM to the internal flash 
    memory. The yellow LED on the front of the TN750C flashes.
    You c an only save the announc ement c ontents of 1 c irc uit p ac k at a time. For the 
    c ontents of every c irc uit p ac k, save to sep arate translation c ard s. Lab el eac h 
    translation c ard  so that it matc hes the c irc uit p ac k.
    TN750 and TN750B Announcement Circuit Packs
    To save the rec ord ed  announc ements in the system, typ e save announcements 
    and  p ress 
    En t e r. Use these c od es after b usiness hours or when the system is 
    op erating  d uring  a low-usage p eriod. The system takes ab out 40 minutes to 
    transfer the rec ord ed  announc ements from the announc ement c irc uit p ac k to the 
    translation c ard . During  this time, the manag ement terminal c annot b e used  to 
    ad minister the system; however, all other ad ministration terminals, if p rovid ed, 
    are allowed  to p erform ad ministration p roc ed ures.
    Ty p e  restore announcements
     and press 
    En te r to restore the rec ord ed  
    announc ements from the translation c ard to system memory. 
    						