    Have a look at the manual Lucent Technologies DEFINITY Enterprise Communication Server Release 8.2 Installation, Upgrades, And Additions For Compact Modular Cabinets Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 413 Lucent Technologies manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.

    							DEFINITY ECS Release 8.2 Installation, Upgrades, 
    and Additions for Compact Modular Cabinets  555-233-118  Issue 1
    April 2000
    Completing Installation and Cable Pinouts 
    2-15 Connector and Cable Diagrams — Pinout Charts 
    2
    Table 2-11 shows the p inout for the TN793 and  TN2793 24-Port Analog  Line 
    circuit pack.
    Table 2-11. TN793 Analog Line Circuit Pack Pinout 
    Port SignalCross-Connect 
    Pin Color Amphenol Pin Backplane Pin
    1T.1 1 W-BL 26 102
    R.1 2 BL-W 01 002
    2 T.2 3 W-O 27 103
    R.2 4 O -W 0 2 0 03
    3 T.3 5 W-G 28 104
    R.3 6 G -W 0 3 0 04
    4T.4 7 W-BR 29 105
    R.4 8 BR-W 04 005
    5T.5 9 W-SL 30 106
    R.5 10 SL-W 05 006
    6 T.6 11 R-BL 31 107
    R.6 12 BL-R 06 007
    7 T.7 13 R-O 32 108
    R.7 14 O-R 07 008
    8 T.8 15 R-G 33 109
    R.8 16 G-R 08 009
    9 T.9 17 R-BR 34 110
    R.9 18 B R- R 0 9 0 10
    10 T.10 19 R-SL 35 111
    R.10 20 SL-R 10 011
    11 T.11 21 BK-BL 36 112
    R.11 22 BL-BK 11 012
    12 T.12 23 BK-O 37 113
    R.12 24 O-BK 12 013
    13 T.13 25 BK-G 38 302
    R.13 26 G-BK 13 202
    Continued on next page 
    						
    							DEFINITY ECS Release 8.2 Installation, Upgrades, 
    and Additions for Compact Modular Cabinets  555-233-118  Issue 1
    April 2000
    Completing Installation and Cable Pinouts 
    2-16 Connector and Cable Diagrams — Pinout Charts 
    2
    14 T.14 27 BK-BR 39 303
    R.14 28 BR-BK 14 203
    15 T.15 29 BK-SL 40 304
    R.15 30 SL-BK 15 204
    16 T.16 31 Y-BL 41 305
    R.16 32 BL-Y 16 205
    17 T.17 33 Y-O 42 306
    R.17 34 O-Y 17 206
    18 T.18 35 Y-G 43 307
    R.18 36 G-Y 18 207
    19 T.19 37 Y-BR 44 308
    R.19 38 BR-Y 19 208
    20 T.20 39 Y-SL 45 309
    R.20 40 SL-Y 20 209
    21 T.21 41 V-BL 46 310
    R.21 42 BL-V 21 210
    22 T.22 43 V-O 47 311
    R.22 44 O-V 22 211
    23 T.23 45 V-G 48 312
    R.23 46 G-V 23 212
    24 T.24 47 V-BR 49 313
    R.24 48 BR-V 24 213
    25 49 V/SL 50 314
    50 50 SL/V 25 214
    Table 2-11. TN793 Analog Line Circuit Pack Pinout  — Continued
    Port SignalCross-Connect 
    Pin Color Amphenol Pin Backplane Pin
    Continued on next page 
    						
    							DEFINITY ECS Release 8.2 Installation, Upgrades, 
    and Additions for Compact Modular Cabinets  555-233-118  Issue 1
    April 2000
    Completing Installation and Cable Pinouts 
    2-17 Connector and Cable Diagrams — Pinout Charts 
    2
    Table 2-12. Circuit Pack and Auxiliary Equipment ClassificationsAnalog
    Line (8)2-Wire 
    Digital 
    & 
    Analog
    Line (16)
    and (24)Data 
    Line & 
    Digital
    Line 
    4-Wire2-Wire 
    Digital & 
    Analog 
    24 PortsHybrid
    LineMET
    1
    Line
    1. MET =  Multib utton Elec tronic Telephone
    AUX
    Tr u n kCentral 
    Office
    Tr u n kDID/
    DIOD
    2
    Tr u n k
    2. DID/DIOD =  Direct Inward  Dialing /Direct Inward  Outward  Dialing
    Tie
    Tr u n kDS1
    Tie
    Tr u n k Central
    Office
    Tr u n k
    3-WireFour 
    Port 
    DIOD
    3
    3. DIOD =  Direct Inward  Outward  DialingTN467 TN2149 TN726B TN2224 TN762 TN735 TN417 TN429 TN2199 TN429 TN478 TN483 TN2184
    TN432 TN2135 TN754B
    TN2214
    TN762B TN763 TN493 TN2139 TN458 TN722
    TN431 TN468B TN564B
    TN 7 9 3
    TN763D TN422 TN459B TN449 TN767
    TN411B TN448 TN413
    TN2793
    TN421 TN436B TN760D TN722B
    TN742 TN746
    TN2214B
    TN438B TN753 TN760C TN464F
    TN769 TN746B
    TN2224B
    TN447 TN2146 TN434 TN2207
    TN2181
    TN793B
    TN465C TN414 TN415 TN2464
    TN2183
    TN2793B
    TN747B TN2209
    TN793 TN2138
    TN2793 TN2147C
    TN2215 TN2148
    TN791
    TN2214 
    						
    							DEFINITY ONE Communications System Release 1.0
     Installation and Upgrades  555-233-109  Issue 1.0
    July 1999
    Completing Installation and Cable Pinouts 
    2-18 Connector and Cable Diagrams - Pinout Charts
    2
    Table 2-13. Circuit Pack and Auxiliary Equipment Leads (Pinout Charts)Color Connector
    Pin
    NumbersAnalog
    Line
    8 ports2-Wire
    Digital
    Line &
    Analog
    Line
    16 portsData 
    Line 
    and 
    Digital
    Line
    4-wire2-Wire
    Digital
    Line &
    Analog
    Line
    24 PortsHybrid
    LineMET
    LineAUX
    TrunkCO
    Tr kCO
    Trunk
    3-wireDID/
    DIOD
    Tr u n kTie
    Tr kDS1
    Ti e
    TrunkFour 
    Port 
    DIOD
    W- BL 2 6 T1 T1 T1 V1 T1 T1 T1 T1 A1 T1 T1 T1
    B L -W 0 1 R1 R1 R1 V1 R1 R1 R1 R1 B1 R1 R1 R1
    W- O 2 7 T2 TXT1 T2 C T1 TXT1 SZ1 T1 1
    O - W 0 2 R2 TXR1 R2 CR1 TXR1 SZ1 1 R1 1
    W- G 2 8 T3 PXT1 T3 P- 1 PXT1 S1 E1
    G - W 0 3 R3 PXR1 R3 P+ 1 PXR1 S1 1 C 1 M 1
    W- BR 2 9 T2 T4 T4 V1 T2 T2 T2 T2 A2 T2 T2 T2
    B R-W 0 4 R2 R4 R4 V1 R2 R2 R2 R2 B2 R2 R2 R2
    W- S 3 0 TXT2 T5 C T2 TXT2 SZ2 T1 2
    S- W 0 5 TXR2 R5 C R2 TXR2 SZ 1 2 R1 2
    R- BL 3 1 PXT2 T6 P- 2 PXT2 S2 E2
    B L -R 0 6 PXR2 R6 P+ 2 PXR2 S1 2 C 2 M 2
    R-O32 T3 T7 V1T3T3T3T3A3T3T3 T3
    O-R07 R3 R7 V1R3R3R3R3B3R3R3 R3
    R- G 3 3 TXT3 T8 CT3 TXT3 SZ3 T1 3
    G - R 0 8 TXR3 R8 CR3 TXR3 SZ1 3 R1 3
    R- B R 3 4 T5 PXT3 T9 P- 3 PXT3 S3 E3
    B R- R 0 9 R5 PXR3 R9 P+ 3 PXR3 S1 3 C 3 M 3
    R- S 3 5 T4 T6 T10 V1 T4 T4 T4 T4 A4 T4 T4 T4
    S- R 1 0 R4 R6 R10 V1 R4 R4 R4 R4 B4 R4 R4 R4
    B K -B L 3 6 T7 TXT4 T11 C T4 TXT4 SZ4 T1 4
    Continued on next page 
    						
    							DEFINITY ONE Communications System Release 1.0
     Installation and Upgrades  555-233-109  Issue 1.0
    July 1999
    Completing Installation and Cable Pinouts 
    2-19 Connector and Cable Diagrams - Pinout Charts
    2
    B L -B K 1 1 R7 TXR4 R11 C R4 TXR4 SZ 1 4 R1 4
    BK-O 37 T8 PXT4 T12 P-4 PXT4 S4 E4
    O - B K 1 2 R8 PXR4 R1 2 P+ 4 PXR4 S1 4 M 4
    B K -G 3 8 T5 T9 T13 V1 T5 T5 T5
    G - B K 1 3 R5 R9 R1 3 V1 R5 R5 R5
    BK-BR 39 T10 TXT5 T14 CT4
    B R-B K 1 4 R1 0 TXR5 R14 CR4
    BK-S 40 T11 PXT5 T15 P-5
    S- B K 1 5 R1 1 PXR5 R15 P+ 5
    Y- B L 4 1 T6 T1 2 T16 V1 T6 T6 T6
    B L -Y 1 6 R6 R1 2 R16 V1 R6 R6 R6
    Y- O 4 2 TXT6 T17 C T6
    O-Y 17 TXR6 R17 CR6
    Y- G 4 3 PXT6 T18 P- 6
    G-Y 18 PXR6 R18 P+ 6
    Y-BR 44 T7 T19 V1T7 T7 T7
    BR-Y 19 R7 R19 V1R7 R7 R7
    Y- S 4 5 TXT7 T20 C T7
    S- Y 2 0 TXR7 R20 C R7
    V- B L 4 6 T1 3 PXT7 T21 P- 7
    BL-V 21 R13 PXR7 R21 P+ 7
    V-O 47 T8 T14 T22 V1T8 T8 T8 LI*Table 2-13. Circuit Pack and Auxiliary Equipment Leads (Pinout Charts)Color Connector
    Pin
    NumbersAnalog
    Line
    8 ports2-Wire
    Digital
    Line &
    Analog
    Line
    16 portsData 
    Line 
    and 
    Digital
    Line
    4-wire2-Wire
    Digital
    Line &
    Analog
    Line
    24 PortsHybrid
    LineMET
    LineAUX
    TrunkCO
    Tr kCO
    Trunk
    3-wireDID/
    DIOD
    Tr u n kTie
    Tr kDS1
    Ti e
    TrunkFour 
    Port 
    DIOD
    Continued on next page 
    						
    							DEFINITY ONE Communications System Release 1.0
     Installation and Upgrades  555-233-109  Issue 1.0
    July 1999
    Completing Installation and Cable Pinouts 
    2-20 Connector and Cable Diagrams - Pinout Charts
    2
    The wire colors in this chart ap p ly only to B25A and  A25B c ab les. H600-307 c ab le colors are not shown.The following  ab b reviations ap p ly for all c irc uit p ac ks unless otherwise noted :
    T,R PBX transmit voic e T  Tip (A) Green
    T1,R1 PBX rec eive voic e R Ring (B) Red
    M PBX transmit sig nal S Sleeve
    E PBX rec eive signal PX PBX transmit
    TX Terminal transmit
    LI, LI* Dig ital Trunk IN LO, LO*Dig ital Trunk OUT
    The following  wire c olors ap ply in the above c hart:
    W White S Slate (Grey)
    BL Blue R Red
    O Orang e BK Blac k
    G Green Y Yellow
    BR Brown V VioletO-V 22 R8 R14 R22 V1R8 R8 R8 LI
    V- G 4 8 T1 5 TXT8 T23 C T8 L O
    G - V 2 3 R1 5 TXR8 R23 CR8 L O*
    V- B R 4 9 T1 6 PXT8 T24 P- 8 L BA C K 2
    BR-V 24 R16 PXR8 R24 P+ 8 LBACK1
    V- S 5 0
    S- V 2 5Table 2-13. Circuit Pack and Auxiliary Equipment Leads (Pinout Charts)Color Connector
    Pin
    NumbersAnalog
    Line
    8 ports2-Wire
    Digital
    Line &
    Analog
    Line
    16 portsData 
    Line 
    and 
    Digital
    Line
    4-wire2-Wire
    Digital
    Line &
    Analog
    Line
    24 PortsHybrid
    LineMET
    LineAUX
    TrunkCO
    Tr kCO
    Trunk
    3-wireDID/
    DIOD
    Tr u n kTie
    Tr kDS1
    Ti e
    TrunkFour 
    Port 
    DIOD
    Continued on next page 
    						
    							Upgrading R6csi/R7csi to R8csi 
    3-1  
    3
    DEFINITY ECS Release 8.2 Installation, Upgrades, 
    and Additions for Compact Modular Cabinets  555-233-118  Issue 1
    April 2000
    3
    Upgrading R6csi/R7csi to R8csi 
    This chapter provides the information to upgrade from a DEFINITY ECS 
    Release 6c si and  Release 7c si system to a Release 8c si. If the c ab inet d oes not 
    have a TN798B Proc essor c irc uit p ac k, you need  to install one. Refer to the 
    DEFINITY Enterp rise Communic ations Server Maintenanc e for R8c si b ook for 
    changing the proc essor circuit pack. Installation of the TN799 C-LAN circuit pac k 
    is op tional.
    DEFINITY Enterp rise Communic ations Server Release 8 Ad ministrator’s Guid e 
    lists DEFINITY ECS Release 8 features and  func tions and  p rovid es the 
    c ommand s, p roc ed ures, and  forms to initialize and  ad minister the system. 
    						
    							DEFINITY ECS Release 8.2 Installation, Upgrades, 
    and Additions for Compact Modular Cabinets  555-233-118  Issue 1
    April 2000
    Upgrading R6csi/R7csi to R8csi 
    3-2 Task Table 
    3
    Ta s k  Ta b l e
    Table 3-1 p rovid es the hig h-level tasks to perform the up g rad es in this c hap ter. 
    Refer to the ap p rop riate p ag e for instruc tions for eac h step .
    Read This First
    Service Interruption
    The up g rad e p roc ess req uires a servic e interruption of ab out 10 minutes and  
    must b e c losely c oord inated  with the c ustomer and  the loc al ac c ount team.
    Contact Network Technicians
    Contac t the tec hnic ian for eac h p ub lic  and  p rivate network b efore the up d ate or 
    up g rad e b eg ins. Otherwise, it is p ossib le that network ac c ess trunk fac ilities will 
    b e b usied  out at the far end .
    Table 3-1. Tasks to Upgrade to Release 8csi 
    áTask Description Page
    Check SPE
    3-5
    Disable TTI (Do not skip  this sec tion! )3-5
    Disable Scheduled Maintenance and Alarm Origination to INADS3-5
    Save Translations3-6
    Verify Software Version3-7
    Install Circuit Pack (if necessary)3-8
    Administer the System3-9
    Enable TTI3-12
    Check Link Status3-12
    Enable Scheduled Maintenance3-12
    Resolve Alarms3-12
    Enable Customer Options and Alarm Origination3-13
    Save Translations3-13
    Return Equipment3-14 
    						
    							DEFINITY ECS Release 8.2 Installation, Upgrades, 
    and Additions for Compact Modular Cabinets  555-233-118  Issue 1
    April 2000
    Upgrading R6csi/R7csi to R8csi 
    3-3 Read This First 
    3
    Translation Card Upgrade Procedures
    Releases 6 and 7 formatted  translation c ard s are c omp atib le with Release 8 
    systems and , therefore, c an b e reused . It is not nec essary to ob tain a new 
    Release 8 formatted translation card.
    Usable Circuit Packs
    Every p ort or c ontrol c irc uit p ac k used  in the up g rad ed  system must c onform to 
    the minimum usab le vintag e requirements for Release 8. Those c irc uit p ac ks 
    must meet the usab le vintag e sp ec ific ations. At a p resale site insp ec tion, the 
    vintag es of every c irc uit p ac k must b e c hec ked. Rep lac e all unusab le vintag e 
    c irc uit p ac ks with c urrent vintag es.
    Refer to Tec hnic al Quarterly, Referenc e Guid e for Circ uit-Pac k Vintag es and  
    Chang e Notic es, and  to the Software Release Letter for c urrent information ab out 
    usab le vintag es. For information ab out usab le vintag es of international c irc uit 
    p ac ks, refer to the ITAC Tec hnic al Alert from your reg ional d istrib utor.
    Software Upgrade 
    Even thoug h the Releases 6 and  7 translations up g rad e automatic ally to Release 
    8, several features req uire sp ec ial attention b ec ause of sc reen c hang es or 
    p otential naming  c onflic ts in the up date or up g rad e p roc ed ure.
    Between c ustomer c onfirmation and  the ac tual up g rad e, the Software Sp ec ialist 
    and  Assoc iate should  c hec k these forms to ensure the up g rad ed  translations are 
    ap p rop riate for the c ustomer’s need s. Enter these translations either loc ally or 
    remotely. If d one remotely, c ontac t the Field  Sup p ort Ad ministration Center 
    (FSAC), with p ossib le assistanc e from the up g rad e tec hnic ian, for the remote 
    entry. For more information, refer to:
    nDEFINITY Enterp rise Communic ations Server Release 8 Ad ministrator’s 
    Guid e
    No ad ministration c hang es should  b e mad e d uring  the up g rad e p roc edure. 
    There c an b e time g aps b etween step s and , sinc e the system c annot p revent 
    ad ministration c hang es, it is up  to the system tec hnic ian to make sure that none 
    are attemp ted  d uring  the entire up g rad e p roc ess.
    Antistatic Protection
    !CAUTION:
    When hand ling  c irc uit pac ks or any c omp onents of a DEFINITY System, 
    always wear an antistatic  wrist g round  strap . Connec t the strap  to an 
    ap p roved  g round  suc h as g round  jac k on the DEFINITY System. 
    						
    							DEFINITY ECS Release 8.2 Installation, Upgrades, 
    and Additions for Compact Modular Cabinets  555-233-118  Issue 1
    April 2000
    Upgrading R6csi/R7csi to R8csi 
    3-4 Read This First 
    3
    Required Hardware
    The equipment in Table 3-2 must be on-site b efore the up g rad e beg ins. To p lac e 
    a c laim for missing  eq uip ment, as p art of the Streamlined  Imp lementation 
    p roc ess, c all 1-800-772-5409, or the numb er p rovid ed  b y your Luc ent 
    Tec hnolog ies rep resentative.
    nGeneric  p rog ram c ard  with the c urrent software release running  in the 
    system
    nOrig inal translation c ard  on whic h the system translations are to b e saved
    nSoftware p atc h (if it exists) that is c urrently ap p lied  to the system 
    (download  this p atc h if a software b ac kout is nec essary)
    nNew translation card provided via upgrade PEC
    NOTE:
    The c si c ab inet must have a TN798B p roc essor c irc uit p ac k. Ap ply the 
    remed iation. The TN799 (C-LAN) c irc uit p ac k is op tional for pac ket b us 
    sup p ort and  Distrib uted  Communic ations System (DCS).  
    Required Tools
    This up g rad e may req uire the following  tools and  other items:
    nWrist ground strap
    nOne c op y of eac h of the following  b ooks:
    — DEFINITY Enterp rise Communic ations Server Maintenanc e for 
    R8 c s i
    — DEFINITY Enterp rise Communic ations Server Release 8 
    Ad ministrator’s Guid e
    Table 3-2. Required Hardware
    Equipment Description Quantity
    406805481 Release 8 Generic  Prog ram Card  (Orang e Card ) 1
    601817448
    or
    601817422
    or
    6018174302-Mb yte Mass-Storag e Translation Card (White Card )
    or
    4-Mb yte Mass-Storag e Translation Card (White Card )
    or
    10-Mbyte Mass-Storag e Translation Card  (White Card )1
    1
    1. A 4-Mbyte translation c ard  is required  for a system with rec ord ed announc ements. A 10-Mb yte
    translation c ard  is req uired  if a DEFINITY Wireless Business System is installed.
    108186255 TN798B Proc essor (if need ed) 1 
    						
    All Lucent Technologies manuals Comments (0)

    Related Manuals for Lucent Technologies DEFINITY Enterprise Communication Server Release 8.2 Installation, Upgrades, And Additions For Compact Modular Cabinets Manual