    Have a look at the manual Lucent Technologies DEFINITY Enterprise Communication Server Release 8.2 Installation, Upgrades, And Additions For Compact Modular Cabinets Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 413 Lucent Technologies manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.

    							DEFINITY ECS Release 8.2 Installation, Upgrades, 
    and Additions for Compact Modular Cabinets  555-233-118  Issue 1
    April 2000
    Installing and Cabling the Cabinets 
    1-5 Comcodes for CMC 
    1
    406304816 ITW Linx Rep lac ement Fuse
    103972758 Data Link Protec tor (1 c irc uit)
    103972733  Data Link Protec tor (8 c irc uits)
    407063478 Elec trostatic  Disc harg e (ESD) Wrist Strap
    107731853 Sing le-Mod e Fib er Op tic  Transc eiver (300A)
    106455348 Multi-Mod e Fib er Op tic  Transc eiver (9823A)
    106455363 Multi-Mod e Fib er Op tic  Transc eiver (9823B)
    407439975 Multi-mod e Fib er Interc onnec t Cab le — 
    20 ft (6.1 m)
    407598325 Sing le-mod e Fib er Interc onnec t Cab le — 
    20 ft (6.1 m)
    105357727 Sing le-mod e Fib er Op tic  Patc h Cord  — 
    2 ft (0.6 m)
    106060718 Sing le-mod e 5-d B Attenuator
    106060734 Sing le-mod e 10-d B Attenuator
    Table 1-1. Comcodes for Release 7.1 and Later — Continued
    Comcode Description
    Continued on next page 
    						
    							DEFINITY ECS Release 8.2 Installation, Upgrades, 
    and Additions for Compact Modular Cabinets  555-233-118  Issue 1
    April 2000
    Installing and Cabling the Cabinets 
    1-6 Install the System Cabinets 
    1
    Install the System Cabinets
    Set the Carrier Address ID — All Cabinets
    Figure 1-2. Setting Carrier Address ID (Right Side)
    1. Proc eed  to either ‘‘Floor-Mount the Cabinet’’ on page 1-7
     or to ‘‘Wall-Mount 
    the Cabinets’’ on page 1-8. Figure Notes
    1.  Carrier A switc h setting s
    2. Carrier B switch setting s3. Carrier C switc h setting s
    OPEN
    123456
    OPEN
    123456
    OPEN
    123456
    swdmdip KLC 073198
    OFF1
    2
    3 
    						
    							DEFINITY ECS Release 8.2 Installation, Upgrades, 
    and Additions for Compact Modular Cabinets  555-233-118  Issue 1
    April 2000
    Installing and Cabling the Cabinets 
    1-7 Install the System Cabinets 
    1
    Floor-Mount the Cabinet
    The c ab inet d imensions (with floor p ed estal) are 28.5 in. (72.4 c m) hig h, 24.5 in. 
    (62.2 c m) wide, and  12 in. (30.5 c m) d eep . Maintain a servic e c learanc e of 12 in. 
    (30.5 c m) on the left, rig ht, and  front of the c ab inet.
    Figure 1-3. Typical Floor Mount Installation
    1. Proc eed  to ‘‘Cable the System’’ on page 1-22
    . Figure Notes
    1. Left p anel (floor-mount p ed estal)
    2. #12 x 1-in. (2.5 c m) should er 
    screws3. 12 in. (30.5 c m) minimum from 
    nearest ob jec t (req uired  to servic e 
    the c irc uit p ac ks)
    indmflor KLC 110397
    1
    2
    3 
    						
    							DEFINITY ECS Release 8.2 Installation, Upgrades, 
    and Additions for Compact Modular Cabinets  555-233-118  Issue 1
    April 2000
    Installing and Cabling the Cabinets 
    1-8 Install the System Cabinets 
    1
    Wall-Mount the Cabinets 
    !CAUTION:
    A fully load ed  system weig hs 58 lb  (26.3 kg ). Use lifting  p rec autions. If the d oors, 
    p ower unit, and  c irc uit p ac ks are removed , the unit weig hs only 29 lb  (13.1 kg ).
    Install Plywood Backing onto Wall
    The p lywood  and  the hard ware to mount the p lywood  are installer-p rovid ed .
    NOTE:
    The following  p lywood  d imensions ac c ount for the extra sp ac e need ed  to 
    install the p anels on eac h side of the c ab inet. The c ab inet is 24 in. (0.6 m) 
    wid e and  eac h p anel is 12 in. (0.3 m) wid e.
    Single-Cabinet Installation
    1. Install a 3/4-in. (2 c m) thic k sheet of 2 x 4-ft (0.6 x 1.2 m) p lywood  
    horizontally onto the wall. See Figure 1-4
    . 
    The top  of the p lywood  must b e at least 54 in. (137 c m) from the floor. 
    2 or 3 Vertically Mounted Cabinets
    1. Install a 3/4-in. (2 c m) thic k sheet of 4 x 8-ft (1.2 x 2.4 m) p lywood  vertic ally 
    onto the wall. See Figure 1-6
    . 
    2 Cabinets Vertically Mounted and 1 Cabinet Horizontally Mounted
    1. Install a 3/4-in. (2 c m) thic k sheet of 4 x 8-ft (1.2 x 2.4 m) p lywood  vertic ally 
    onto the wall. See Figure 1-6
    .
    2. Install a 3/4-in. (2 c m) thic k sheet of 2 x 4-ft (0.6 x 1.2 m) sheet of p lywood  
    horizontally onto the wall. Position the p lywood to the rig ht of the first 
    sheet, ac ross from Cab inet A.  
    						
    							DEFINITY ECS Release 8.2 Installation, Upgrades, 
    and Additions for Compact Modular Cabinets  555-233-118  Issue 1
    April 2000
    Installing and Cabling the Cabinets 
    1-9 Install the System Cabinets 
    1
    Install Cabinet A — Wall-Mount
    Figure 1-4. Left Panel Used as Mounting Template
    1. Plac e the temp late on the wall ensuring  that the top  surfac e is level.
    2. Mark two 1/8-in. (0.3 c m) p ilot holes in the mounting  hole loc ations.
    3. Remove the temp late from the wall.
    4. Drill the two p ilot holes.
    5. Thread  two #12 x 1-in. should er sc rews p artially into the holes.
    6. Set the c ab inet onto the wall and alig n the slots with the should er sc rews. 
    See Figure 1-5
    . Slid e the c ab inet to the left to hold  it in p lac e. Tig hten the 
    sc rews sec urely. 
    						
    							DEFINITY ECS Release 8.2 Installation, Upgrades, 
    and Additions for Compact Modular Cabinets  555-233-118  Issue 1
    April 2000
    Installing and Cabling the Cabinets 
    1-10 Install the System Cabinets 
    1
    Figure 1-5. Typical Wall-Mount Installation
    7. Drill two lower mounting  holes using  the c ab inet as a temp late.
    8. Thread  the 2 lower sc rews and  tighten.
    !CAUTION:
    Be sure the rig ht b ottom safety sc rew is in p lac e and  tig ht. Figure Notes
    1. #12 x 1-in. should er sc rews 2. #12 x 1-inc h safety sc rew
    indmins1 KLC 110397FLOOR
    A
    2
    1 
    						
    							DEFINITY ECS Release 8.2 Installation, Upgrades, 
    and Additions for Compact Modular Cabinets  555-233-118  Issue 1
    April 2000
    Installing and Cabling the Cabinets 
    1-11 Install the System Cabinets 
    1
    Install 2 or 3 Vertically Mounted Cabinets 
    Figure 1-6. Typical Vertical Multicabinet Installation
    1. Sec urely tig hten the should er sc rews and  safety sc rews. Figure Notes
    1. #12 x 1-inc h should er sc rews 2. #12 x 1-inc h safety sc rew
    Floorindmins7 LJK 102197
    5 (12.7 cm)
    A
    C
    B
    48 (122 cm)
    1
    12
    1 
    						
    							DEFINITY ECS Release 8.2 Installation, Upgrades, 
    and Additions for Compact Modular Cabinets  555-233-118  Issue 1
    April 2000
    Installing and Cabling the Cabinets 
    1-12 Install the System Cabinets 
    1
    Install 2 Cabinets Vertically and 1 Cabinet 
    Horizontally 
    Figure 1-7. Typical 3-Cabinet Installation
    1. Sec urely tig hten the should er sc rews and  safety sc rews. Figure Notes
    1. #12 x 1-inc h should er sc rews
    2. #12 x 1-inc h safety sc rew3. Sec ond  sheet of plywood
    Floorindmins9 LJK 102197
    29 1/2
    (75 cm)
    54
    (137 cm)
    5 (12.7 cm)
    96 (244 cm)
    1
    12
    3A
    C
    B
    1 
    						
    							DEFINITY ECS Release 8.2 Installation, Upgrades, 
    and Additions for Compact Modular Cabinets  555-233-118  Issue 1
    April 2000
    Installing and Cabling the Cabinets 
    1-13 Install the System Cabinets 
    1
    Install Left and Right Panels — Wall-Mount
    Figure 1-8. Left and Right Panel Installation
    1. Alig n the c utouts in the p anels with the c ab inet hing es.
    2. Drill a 1/8-inc h (0.3 c m) p ilot hole into the wall and  sec ure the p anels with 
    the #12 x 1-inc h should er sc rews. Figure Notes
    1. Left p anel 2. Rig ht p anel
    indmins3 KLC 091197 
    						
    							DEFINITY ECS Release 8.2 Installation, Upgrades, 
    and Additions for Compact Modular Cabinets  555-233-118  Issue 1
    April 2000
    Installing and Cabling the Cabinets 
    1-14 AC Power and Ground 
    1
    AC Power and Ground
    !CAUTION:
    The system req uires a d ed ic ated  AC p ower c irc uit that is not shared  with other 
    eq uip ment and is not c ontrolled  b y a wall switc h. The AC rec ep tac le must not b e 
    loc ated  und er the Main Distrib ution Frame and  must b e easily ac c essib le.
    !CAUTION:
    The latc h only removes DC p ower from the c ab inet. Unseating  the p ower sup p ly 
    removes AC p ower from the p ower sup p ly, b ut not from the c ab inet. To remove AC 
    p ower from the c abinet, p ull the AC p ower c ord  from the AC ap p lianc e c onnec tor on 
    the rear of the c ab inet.
    !CAUTION:
    System g round ing  must c omp ly with the g eneral rules for g round ing  p rovid ed  in 
    Artic le 250 of the National Elec tric al Cod e (NEC), National Fire Protec tion Ag enc y 
    (NFPA) 70, or the ap p lic ab le elec tric  c ode in the c ountry of installation. 
    !CAUTION:
    AC mains wiring and testing must be performed by a qualified electrician and must 
    c onform to Artic le 250 of the National Elec tric al Cod e (NEC), National Fire Protec tion 
    Ag enc y (NFPA) 70, or the ap plic ab le elec tric  c od e in the c ountry of installation. 
    Check AC Power
    Eac h CMC uses an auto-ranging  85 to 264 VAC p ower sup p ly, 47 to 63 Hz, 
    330 W, 4.5 amp s (100-120 VAC) or 2.3 amp s (200 to 240 VAC), at 500 VA. The 
    AC p ower sourc e c an be 1 p hase of 120 VAC with neutral (100 VAC for Jap an) 
    with 15 amp  c irc uit b reaker, or 1 p hase of 220 or 240 VAC (200 VAC for Jap an) 
    with 10 amp  c irc uit b reaker. The AC c ord uses a NEMA 5-15P p lug or an IEC 320 
    plug.
    Before p owering  up  the system, c hec k the AC p ower in the eq uip ment room 
    using a KS-20599 d ig ital voltmeter (DVM) (or eq uivalent).
    1. Measure the AC voltag e b etween the hot and neutral sid e of the 
    rec ep tac le.
    2. Dep end ing  on the AC p ower sourc e, verify that the meter read s 90 to 132 
    VAC or 180 to 264 VAC. If not, have a q ualified  elec tric ian c orrec t the 
    problem.
    3. Measure the voltag e b etween the neutral and ground  sid e of the 
    rec ep tac le.
    4. Verify that the meter read s 0 VAC. If not, have a q ualified elec tric ian 
    c orrec t the p rob lem.
    5. When finished , set the AC mains c irc uit breakers to 
    OFF.  
    						