Have a look at the manual Lucent Technologies DEFINITY Enterprise Communication Server Release 8.2 Installation, Upgrades, And Additions For Compact Modular Cabinets Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 413 Lucent Technologies manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.
DEFINITY ECS Release 8.2 Installation, Upgrades, and Additions for Compact Modular Cabinets 555-233-118 Issue 1 April 2000 Installing and Cabling the Cabinets 1-5 Comcodes for CMC 1 406304816 ITW Linx Rep lac ement Fuse 103972758 Data Link Protec tor (1 c irc uit) 103972733 Data Link Protec tor (8 c irc uits) 407063478 Elec trostatic Disc harg e (ESD) Wrist Strap 107731853 Sing le-Mod e Fib er Op tic Transc eiver (300A) 106455348 Multi-Mod e Fib er Op tic Transc eiver (9823A) 106455363 Multi-Mod e Fib er Op tic Transc eiver (9823B) 407439975 Multi-mod e Fib er Interc onnec t Cab le — 20 ft (6.1 m) 407598325 Sing le-mod e Fib er Interc onnec t Cab le — 20 ft (6.1 m) 105357727 Sing le-mod e Fib er Op tic Patc h Cord — 2 ft (0.6 m) 106060718 Sing le-mod e 5-d B Attenuator 106060734 Sing le-mod e 10-d B Attenuator Table 1-1. Comcodes for Release 7.1 and Later — Continued Comcode Description Continued on next page
DEFINITY ECS Release 8.2 Installation, Upgrades, and Additions for Compact Modular Cabinets 555-233-118 Issue 1 April 2000 Installing and Cabling the Cabinets 1-6 Install the System Cabinets 1 Install the System Cabinets Set the Carrier Address ID — All Cabinets Figure 1-2. Setting Carrier Address ID (Right Side) 1. Proc eed to either ‘‘Floor-Mount the Cabinet’’ on page 1-7 or to ‘‘Wall-Mount the Cabinets’’ on page 1-8. Figure Notes 1. Carrier A switc h setting s 2. Carrier B switch setting s3. Carrier C switc h setting s OPEN 123456 OPEN 123456 OPEN 123456 swdmdip KLC 073198 OFF1 2 3
DEFINITY ECS Release 8.2 Installation, Upgrades, and Additions for Compact Modular Cabinets 555-233-118 Issue 1 April 2000 Installing and Cabling the Cabinets 1-7 Install the System Cabinets 1 Floor-Mount the Cabinet The c ab inet d imensions (with floor p ed estal) are 28.5 in. (72.4 c m) hig h, 24.5 in. (62.2 c m) wide, and 12 in. (30.5 c m) d eep . Maintain a servic e c learanc e of 12 in. (30.5 c m) on the left, rig ht, and front of the c ab inet. Figure 1-3. Typical Floor Mount Installation 1. Proc eed to ‘‘Cable the System’’ on page 1-22 . Figure Notes 1. Left p anel (floor-mount p ed estal) 2. #12 x 1-in. (2.5 c m) should er screws3. 12 in. (30.5 c m) minimum from nearest ob jec t (req uired to servic e the c irc uit p ac ks) indmflor KLC 110397 1 2 3
DEFINITY ECS Release 8.2 Installation, Upgrades, and Additions for Compact Modular Cabinets 555-233-118 Issue 1 April 2000 Installing and Cabling the Cabinets 1-8 Install the System Cabinets 1 Wall-Mount the Cabinets !CAUTION: A fully load ed system weig hs 58 lb (26.3 kg ). Use lifting p rec autions. If the d oors, p ower unit, and c irc uit p ac ks are removed , the unit weig hs only 29 lb (13.1 kg ). Install Plywood Backing onto Wall The p lywood and the hard ware to mount the p lywood are installer-p rovid ed . NOTE: The following p lywood d imensions ac c ount for the extra sp ac e need ed to install the p anels on eac h side of the c ab inet. The c ab inet is 24 in. (0.6 m) wid e and eac h p anel is 12 in. (0.3 m) wid e. Single-Cabinet Installation 1. Install a 3/4-in. (2 c m) thic k sheet of 2 x 4-ft (0.6 x 1.2 m) p lywood horizontally onto the wall. See Figure 1-4 . The top of the p lywood must b e at least 54 in. (137 c m) from the floor. 2 or 3 Vertically Mounted Cabinets 1. Install a 3/4-in. (2 c m) thic k sheet of 4 x 8-ft (1.2 x 2.4 m) p lywood vertic ally onto the wall. See Figure 1-6 . 2 Cabinets Vertically Mounted and 1 Cabinet Horizontally Mounted 1. Install a 3/4-in. (2 c m) thic k sheet of 4 x 8-ft (1.2 x 2.4 m) p lywood vertic ally onto the wall. See Figure 1-6 . 2. Install a 3/4-in. (2 c m) thic k sheet of 2 x 4-ft (0.6 x 1.2 m) sheet of p lywood horizontally onto the wall. Position the p lywood to the rig ht of the first sheet, ac ross from Cab inet A.
DEFINITY ECS Release 8.2 Installation, Upgrades, and Additions for Compact Modular Cabinets 555-233-118 Issue 1 April 2000 Installing and Cabling the Cabinets 1-9 Install the System Cabinets 1 Install Cabinet A — Wall-Mount Figure 1-4. Left Panel Used as Mounting Template 1. Plac e the temp late on the wall ensuring that the top surfac e is level. 2. Mark two 1/8-in. (0.3 c m) p ilot holes in the mounting hole loc ations. 3. Remove the temp late from the wall. 4. Drill the two p ilot holes. 5. Thread two #12 x 1-in. should er sc rews p artially into the holes. 6. Set the c ab inet onto the wall and alig n the slots with the should er sc rews. See Figure 1-5 . Slid e the c ab inet to the left to hold it in p lac e. Tig hten the sc rews sec urely.
DEFINITY ECS Release 8.2 Installation, Upgrades, and Additions for Compact Modular Cabinets 555-233-118 Issue 1 April 2000 Installing and Cabling the Cabinets 1-10 Install the System Cabinets 1 Figure 1-5. Typical Wall-Mount Installation 7. Drill two lower mounting holes using the c ab inet as a temp late. 8. Thread the 2 lower sc rews and tighten. !CAUTION: Be sure the rig ht b ottom safety sc rew is in p lac e and tig ht. Figure Notes 1. #12 x 1-in. should er sc rews 2. #12 x 1-inc h safety sc rew indmins1 KLC 110397FLOOR A 2 1
DEFINITY ECS Release 8.2 Installation, Upgrades, and Additions for Compact Modular Cabinets 555-233-118 Issue 1 April 2000 Installing and Cabling the Cabinets 1-11 Install the System Cabinets 1 Install 2 or 3 Vertically Mounted Cabinets Figure 1-6. Typical Vertical Multicabinet Installation 1. Sec urely tig hten the should er sc rews and safety sc rews. Figure Notes 1. #12 x 1-inc h should er sc rews 2. #12 x 1-inc h safety sc rew Floorindmins7 LJK 102197 5 (12.7 cm) A C B 48 (122 cm) 1 12 1
DEFINITY ECS Release 8.2 Installation, Upgrades, and Additions for Compact Modular Cabinets 555-233-118 Issue 1 April 2000 Installing and Cabling the Cabinets 1-12 Install the System Cabinets 1 Install 2 Cabinets Vertically and 1 Cabinet Horizontally Figure 1-7. Typical 3-Cabinet Installation 1. Sec urely tig hten the should er sc rews and safety sc rews. Figure Notes 1. #12 x 1-inc h should er sc rews 2. #12 x 1-inc h safety sc rew3. Sec ond sheet of plywood Floorindmins9 LJK 102197 29 1/2 (75 cm) 54 (137 cm) 5 (12.7 cm) 96 (244 cm) 1 12 3A C B 1
DEFINITY ECS Release 8.2 Installation, Upgrades, and Additions for Compact Modular Cabinets 555-233-118 Issue 1 April 2000 Installing and Cabling the Cabinets 1-13 Install the System Cabinets 1 Install Left and Right Panels — Wall-Mount Figure 1-8. Left and Right Panel Installation 1. Alig n the c utouts in the p anels with the c ab inet hing es. 2. Drill a 1/8-inc h (0.3 c m) p ilot hole into the wall and sec ure the p anels with the #12 x 1-inc h should er sc rews. Figure Notes 1. Left p anel 2. Rig ht p anel indmins3 KLC 091197
DEFINITY ECS Release 8.2 Installation, Upgrades, and Additions for Compact Modular Cabinets 555-233-118 Issue 1 April 2000 Installing and Cabling the Cabinets 1-14 AC Power and Ground 1 AC Power and Ground !CAUTION: The system req uires a d ed ic ated AC p ower c irc uit that is not shared with other eq uip ment and is not c ontrolled b y a wall switc h. The AC rec ep tac le must not b e loc ated und er the Main Distrib ution Frame and must b e easily ac c essib le. !CAUTION: The latc h only removes DC p ower from the c ab inet. Unseating the p ower sup p ly removes AC p ower from the p ower sup p ly, b ut not from the c ab inet. To remove AC p ower from the c abinet, p ull the AC p ower c ord from the AC ap p lianc e c onnec tor on the rear of the c ab inet. !CAUTION: System g round ing must c omp ly with the g eneral rules for g round ing p rovid ed in Artic le 250 of the National Elec tric al Cod e (NEC), National Fire Protec tion Ag enc y (NFPA) 70, or the ap p lic ab le elec tric c ode in the c ountry of installation. !CAUTION: AC mains wiring and testing must be performed by a qualified electrician and must c onform to Artic le 250 of the National Elec tric al Cod e (NEC), National Fire Protec tion Ag enc y (NFPA) 70, or the ap plic ab le elec tric c od e in the c ountry of installation. Check AC Power Eac h CMC uses an auto-ranging 85 to 264 VAC p ower sup p ly, 47 to 63 Hz, 330 W, 4.5 amp s (100-120 VAC) or 2.3 amp s (200 to 240 VAC), at 500 VA. The AC p ower sourc e c an be 1 p hase of 120 VAC with neutral (100 VAC for Jap an) with 15 amp c irc uit b reaker, or 1 p hase of 220 or 240 VAC (200 VAC for Jap an) with 10 amp c irc uit b reaker. The AC c ord uses a NEMA 5-15P p lug or an IEC 320 plug. Before p owering up the system, c hec k the AC p ower in the eq uip ment room using a KS-20599 d ig ital voltmeter (DVM) (or eq uivalent). 1. Measure the AC voltag e b etween the hot and neutral sid e of the rec ep tac le. 2. Dep end ing on the AC p ower sourc e, verify that the meter read s 90 to 132 VAC or 180 to 264 VAC. If not, have a q ualified elec tric ian c orrec t the problem. 3. Measure the voltag e b etween the neutral and ground sid e of the rec ep tac le. 4. Verify that the meter read s 0 VAC. If not, have a q ualified elec tric ian c orrec t the p rob lem. 5. When finished , set the AC mains c irc uit breakers to OFF.