    Have a look at the manual Lucent Technologies DEFINITY Enterprise Communication Server Release 8.2 Installation, Upgrades, And Additions For Compact Modular Cabinets Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 413 Lucent Technologies manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.

    							DEFINITY ECS Release 8.2 Installation, Upgrades, 
    and Additions for Compact Modular Cabinets  555-233-118  Issue 1
    April 2000
    Adding or Removing Hardware 
    4-39 Add IP Interface Assembly 
    4
    3. Type iptrunk
     in the Password
     field  and  c lic k OK
    . 
    4. After log g ing  on for the first time, c hang e the ad ministrator p assword and , 
    if d esired , the user name, to ensure sec urity. See your Wind ows NT server 
    d oc umentation for d etails.
    A-Law versus Mu-Law
    For systems using  A-Law c omp and ing , an ad d itional p roc ed ure is nec essary. 
    On the SAT:
    1. Busyout the trunk g roup  assoc iated  with the IP trunk b y typing  busyout 
    board 
    UUCSS and  p ressing  En t e r.
    In the Wind ows interfac e to TN802B:
    1. Click on Control Panel > Services.
    2. Highlight IP Trunk Service
    , then c lic k on Stop
    .
    3. In the lower left-hand  c orner, rig ht-c lic k Start >  Exp lore.
    4. Go to the c : d rive and  c lic k on its, then b in.
    5. Double-c lic k on the its.ini file to op en it in Notep ad .
    6. Und er the [ Med iaLib ]  sec tion, g o to COMPANDING= MLAW. Chang e 
    MLAW
     to ALAW
    .
    7. Click on File > Save
     to save the file.
    8. Click on File > Exit
     to exit Notep ad .
    9. Click on Control Panel > Services.
    10. Highlight IP Trunk Service
    , then c lic k on Start
    .
    NOTE:
    Do not selec t Startup .
    After servic e has started , g o to the SAT:
    1. Release the trunk g roup  assoc iated  with the IP trunk b y typing  release 
    board
     
    UUCSS and  p ressing  En t e r.
    Assign Server and Domain Names
    The Windows NT server identifies servers using a server name plus a domain 
    name that loc ates the named  server in a p artic ular p art of the network. The 
    TN802B IP Interfac e is ship p ed  with generic  server and  d omain names. Assig n 
    rep lac ement names that are meaning ful within your network. 
    1. Click on My Computer > Control Panel > Network
    .
    2. Selec t the Identification
     tab , then c lic k Change
    .
    3. Typ e the new server name in the Computer Name 
    field . 
    						
    							DEFINITY ECS Release 8.2 Installation, Upgrades, 
    and Additions for Compact Modular Cabinets  555-233-118  Issue 1
    April 2000
    Adding or Removing Hardware 
    4-40 Add IP Interface Assembly 
    4
    4. Typ e the new d omain name in the Domain
     field and  c lic k OK > OK > 
    Close
    .
    5. When p romp ted  to reb oot the c omp uter, selec t one of the following  
    op tions:
    nNo
     if you have not assig ned  IP ad dresses then g o to ‘‘Assign an IP 
    Address’’
    nYe s
     if you have assigned  IP ad dresses. 
    Assign an IP Address
    1. Click on My Computer > Control Panel > Network
    .
    2. Click the Protocols
     tab .
    3. Select TCP/IP Protocol 
    from the list.
    4. Click the Properties
     op tion in the Network wind ow. 
    5. Verify that the Adapter
     drop  d own menu lists 2 DEC Ethernet ad ap ters. 
    						
    							DEFINITY ECS Release 8.2 Installation, Upgrades, 
    and Additions for Compact Modular Cabinets  555-233-118  Issue 1
    April 2000
    Adding or Removing Hardware 
    4-41 Add IP Interface Assembly 
    4
    !CAUTION:
    Do not c hange any setting s on the ad ap ter lab eled  [ 1]  for any 
    reason.
    6. Selec t the DEC Ethernet ad ap ter lab eled  [ 2] .
    7. Typ e a valid  IP ad d ress for the IP Interfac e server in the IP Address:
     
    field .
    8. Typ e the ap p rop riate sub net mask in the Subnet Mask:
     field. 
    NOTE:
    Not all networks req uire step s 9 throug h 18. Chec k with the loc al 
    network ad ministrator to determine whic h are req uired .
    9. If you use g ateways, type the IP ad d ress of the d efault g ateway for the IP 
    Interfac e server in the Default Gateway:
     field.
    10. Clic k on the DNS tab  and  verify that the d omain DNS server is c orrec t. 
    						
    							DEFINITY ECS Release 8.2 Installation, Upgrades, 
    and Additions for Compact Modular Cabinets  555-233-118  Issue 1
    April 2000
    Adding or Removing Hardware 
    4-42 Add IP Interface Assembly 
    4
    11. Typ e d omain name in the Domain
     field .
    12. If using  DNS, c lic k 
    Add  under the DNS Service Search Order
     field  and 
    type its IP ad d ress.
    13. Clic k on the WINS Ad dress tab . 
    						
    							DEFINITY ECS Release 8.2 Installation, Upgrades, 
    and Additions for Compact Modular Cabinets  555-233-118  Issue 1
    April 2000
    Adding or Removing Hardware 
    4-43 Add IP Interface Assembly 
    4
    14. Make sure the [ 2]  DEC shows in the Adapter
     field.
    15. If WINS server is availab le, typ e its IP ad d ress in the Primary WINS 
    Server
     field .
    16. If DNS is availab le, selec t Enable DNS for Windows Resolution
    .
    17. If the network uses an imp orted LMHOSTS file, selec t Enable LMHOSTS 
    Lookup 
    and Import LMHOSTS
     and c lic k OK
    .
    18. If the following  d ialog  b ox op ens, c lic k Ye s
    :
    At least one of the adapter cards has an empty primary 
    WINS address. Do you want to continue?
    19. Clic k the Bindings
     tab  to effec t the c hang es.
    NetBIOS Interface, Server, and Workstation should now be enabled. If any 
    are d isab led  (a red  c irc le with a line throug h it), review the p revious 
    network-c onfig uration step s for omissions or errors.
    20. Clic k Close
    . 
    						
    							DEFINITY ECS Release 8.2 Installation, Upgrades, 
    and Additions for Compact Modular Cabinets  555-233-118  Issue 1
    April 2000
    Adding or Removing Hardware 
    4-44 Add IP Interface Assembly 
    4
    If administered  remotely throug h p c ANYWHERE:
    21. Clic k on the p c ANYWHERE Restart Host Comp uter b utton on the toolb ar 
    to restart the c omputer.
    If administered  loc ally on a monitor, keyb oard, and  mouse:
    21. Clic k Ye s
     in the d ialog  b ox to restart the c omp uter. 
    !WARNING:
    When c onnec ted  remotely via p c ANYWHERE, only use the p c ANYWHERE 
    Restart Host Computer button on the toolbar to restart Windows NT.
    Check Network Services
    When the server restarts, make sure that the req uired  network servic es have 
    started c orrec tly. If you see an error d ialog  b ox, then the network servic es d id  not 
    start c orrec tly. Also, c hec k the NT Event Log.
    1. Click on My Computer > Control Panel > Network > Services. 
    Make 
    sure that the following  servic es are listed:
    nComp uter Browser
    nMic rosoft Internet Information Server 2.0
    nNetBIOS Interfac e
    nRPC Config uration
    nSe r ve r
    nWorkstation
    2. Click the Protocols 
    tab , and examine the Network Protoc ols. TCP/IP 
    p rotoc ol should  b e the only one listed .
    3. Click OK
    .
    Test the External Connection to the LAN
    To test the external IP c onnec tions, p ing  the IP Interfac e server and  p ing  a known 
    c omp uter c onnec ted  to your network.
    1. Click Start > Programs > Command Prompt
    .
    2. Type ping 
    nnn.nnn.nnn.nnn (whic h is your IP ad d ress).
    nIf everything  is c onfigured  c orrec tly, the system respond s with the 
    following message:
    Reply from nnn.nnn.nnn.nnn: bytes=32 time
    						
    							DEFINITY ECS Release 8.2 Installation, Upgrades, 
    and Additions for Compact Modular Cabinets  555-233-118  Issue 1
    April 2000
    Adding or Removing Hardware 
    4-45 Add IP Interface Assembly 
    4
    3. At the c ommand p romp t, type ping nnn.nnn.nnn.nnn (whic h is the IP 
    ad d ress of your g ateway). 
    nIf everything  is c onfigured  c orrec tly, the system respond s with the 
    following message:
    Reply from nnn.nnn.nnn.nnn: bytes=32 time Settings > Control Panel > 
    Network
    . Selec t the Adapters
     tab  and  hig hlight the [ 2]  DEC 
    ad ap ter.
    nClic k Properties > Change
    . 
    nFrom the Duplex Mod e d ropd own menu, selec t a setting  that 
    matc hes the switc h/hub  that the TN802B c onnec ts to. For examp le, 
    10BaseT Full Dup lex or 10BaseT No Link Test
    4. At the c ommand p romp t, type ping 
    nnn.nnn.nnn.nnn (whic h is the IP 
    ad d ress of another external c omp uter beyond  the g ateway). 
    nIf you have c onnec tivity, the system respond s with the following  
    messag e:
    Reply from nnn.nnn.nnn.nnn: bytes=32 time Programs > Command Prompt
    .
    2. Type ping 
    192.11.13.9 (whic h is the IP ad d ress of the internal IP Interfac e 
    server). 
    nIf everything  is c onfigured  c orrec tly, the system respond s with the 
    following message:
    Reply from 192.11.13.9: bytes=32 time
    						
    							DEFINITY ECS Release 8.2 Installation, Upgrades, 
    and Additions for Compact Modular Cabinets  555-233-118  Issue 1
    April 2000
    Adding or Removing Hardware 
    4-46 Add IP Interface Assembly 
    4
    3. At the c ommand  p romp t, typ e ping 192.11.13.8 (whic h is the IP ad d ress of 
    the internal p roc essor). 
    nIf you have c onnec tivity, the system respond s with the following  
    messag e:
    Reply from 192.11.13.8: bytes=32 time
    						
    							DEFINITY ECS Release 8.2 Installation, Upgrades, 
    and Additions for Compact Modular Cabinets  555-233-118  Issue 1
    April 2000
    Adding or Removing Hardware 
    4-47 Add IP Interface Assembly 
    4
    3. Attach the mouse to the MOUSE connector of the external c able 
    assemb ly.
    4. Plug  the monitor into an AC p ower rec ep tac le and  turn it on.
    5. If upg rad ing  loc ally, reb oot Wind ows NT b y p ressing  the rec essed  reset 
    b utton on the fac ep late (see Figure 4-9
    ) of the TN802B IP Interfac e until 
    the LCD shows a flashing  MSHUT *
    . When the flashing stops and the 
    asterisk d isap p ears (ab out 2 min), it is safe to remove the c irc uit p ac k.
    6. After the TN802B is shut d own, reseat the c irc uit p ac k to restart the 
    system.
    7. Log in using ctrl alt del
    Upgrading IP trunks (R7) to H.323 trunks
    If there are existing  IP trunk c onnec tions that you want to up g rad e to H.323 trunk 
    c onnec tions, d o the following  step s. Otherwise, g o to ‘‘Upgrade to TN802B (R8)’’ 
    on page 4-48
    To upg rad e an existing  IP trunk (R7) to an H.323 trunk (R8) req uires first g etting  
    IP information from the existing  TN802 b efore up g rad ing the TN802 to TN802B.
    1. Click on My Computer > Control Panel > Network
    .
    2. Click the Protocols
     tab .
    3. Select TCP/IP Protocol 
    from the list.
    4. Click the Properties
     op tion in the Network wind ow. Write d own the IP 
    ad d ress, sub net ad d ress, and  g ateway ad d ress shown for ad ap tor [2] 
    (see example b elow).
    NOTE:
    Do not use the ad d resses for ad ap ter [ 1] . 
    						
    							DEFINITY ECS Release 8.2 Installation, Upgrades, 
    and Additions for Compact Modular Cabinets  555-233-118  Issue 1
    April 2000
    Adding or Removing Hardware 
    4-48 Add IP Interface Assembly 
    4
    5. When d one, c lic k OK, OK
    .
    Upgrade to TN802B (R8)
    NOTE:
    The upg rad e takes ab out 20 minutes.
    1. Insert the flash d isk into the rig ht most slot on the TN802 IP trunk. On the 
    monitor, a d ialog  b ox assig ns a d rive letter with the removab le med ia 
    d esig nation; the d efault is D:. 
    2. Rig ht c lic k on Start > Explore
     to op en the Wind ows NT Exploring  p ane 
    and  selec t the d rive letter ind ic ated in step  1.
    3. Double-clic k on Medpro 
    and  selec t the Setup  ic on.
    4. Follow the Install Shield  p roc ed ure to transfer all the nec essary files to the 
    TN802 IP Interfac e.  
    						
    All Lucent Technologies manuals Comments (0)