    Have a look at the manual Lucent Technologies DEFINITY Enterprise Communication Server Release 8.2 Installation, Upgrades, And Additions For Compact Modular Cabinets Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 413 Lucent Technologies manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.

    							DEFINITY ECS Release 8.2 Installation, Upgrades, 
    and Additions for Compact Modular Cabinets  555-233-118  Issue 1
    April 2000
    Completing Installation and Cable Pinouts 
    2-5 TN760D Tie Trunk Option Settings 
    2
    TN760D Tie Trunk Option Settings
    The TN760D Tie Trunk c irc uit p ac k interfac es b etween 4 tie trunks and  the TDM 
    b us. Two tip  and  ring  p airs form a 4-wire analog  transmission line. An E and  M 
    p air are DC sig naling  lead s used  for c all setup . The E-lead  rec eives sig nals from 
    the tie trunk and  the M-lead  transmits sig nals to the tie trunk. 
    To c hoose the preferred  sig naling  format (Table 2-2
     and Table 2-3), set the 
    switc hes on the TN760D and  ad minister the p ort using  Figure 2-2
     and Table 2-4. 
    Table 2-2. Signaling Formats for TN760D
    Mode Type
    E & M Typ e I Stand ard  (unp rotec ted )
    E & M Typ e I Comp atib le (unp rotec ted )
    Protec ted Type I Comp atib le, Typ e I Stand ard
    Sim p l e x Typ e  V
    E & M Typ e  V
    E & M Typ e V Revised
    Table 2-3. Signaling Type Summary
    Signaling Type Transmit (M-Lead) Receive (E-Lead)
    On-Hook Off-Hook On-Hook Off-Hook
    Type I Standard ground battery open
    1/b attery
    1. An op en c irc uit is p referred  instead  of b attery voltag e.
    g round
    Typ e I Comp atib le op en
    1/b attery g round g round op en1/b attery
    Type V open
    1/b attery g round open g round
    Typ e V Reversed g round op en g round op en 
    						
    							DEFINITY ECS Release 8.2 Installation, Upgrades, 
    and Additions for Compact Modular Cabinets  555-233-118  Issue 1
    April 2000
    Completing Installation and Cable Pinouts 
    2-6 TN760D Tie Trunk Option Settings 
    2
    Figure 2-2. TN760D Tie Trunk Circuit Pack (Component Side)
    Table 2-4. TN760D Option Switch Settings and Administration
    Installation Situation Preferred Signaling FormatE&M/SMPLX 
    SwitchProt/Unprot 
    SwitchAdministered
    Port
    Circumstance To System Far-End
    Colloc ated DEFINITY E&M Typ e 1 E&M Typ e 1 E&M Unp rotec ted Typ e 1
    Comp atib le Stand ard Compatible
    Inter-Build ing DEFINITY Protec ted 
    Typ e 1Protec ted 
    Typ e 1E&M Pro te c t e d Typ e  1
    Comp atib le Stand ard 
    Pl u sCompatible
    Protec tion
    Unit
    Colloc ated Net 
    IntegratedE&M Typ e 1 Any PBX E&M Unp rotec ted Typ e 1
    Stand ard
    4321
    PORT 4 PORT 3 PORT 2PORT 1 UNPROT
    PROTSMPLX
    E&MSMPLX
    E&MSMPLX
    E&MSMPLX
    E&M
    r758183RBP050896 
    						
    							DEFINITY ECS Release 8.2 Installation, Upgrades, 
    and Additions for Compact Modular Cabinets  555-233-118  Issue 1
    April 2000
    Completing Installation and Cable Pinouts 
    2-7 TN464E/F Option Settings 
    2
    TN464E/F Option Settings 
    The TN464E/F DS1/E1 Interfac e - T1/E1 c irc uit p ac k interfac es b etween a 24- or 
    32-c hannel Central Offic e/ISDN or tie trunk and  the TDM b us. 
    Set the switc hes on the c irc uit p ac k to selec t b it rate and imp edanc e matc h. See 
    Table 2-5
     and  Figure 2-3. If the top  switc h setting  is set to 32 c hannel, then set 
    the lower switc h setting  to either 120 ohm or 75 ohm. 
    Table 2-5. Option Switch Settings on TN464E/F
    120 ohms Twisted  p air
    75 ohms Coaxial req uiring  888B ad ap ter
    32 Channel
    1
    1. If the 24/32 c hannel switc h is not set p er
    ad ministration (or vic e versa), the c irc uit p ac k
    alarms and  will not b e p resent in the list
    configuration command.2.048 Mb p s
    24 Channel
    11.544 Mb p s 
    						
    							DEFINITY ECS Release 8.2 Installation, Upgrades, 
    and Additions for Compact Modular Cabinets  555-233-118  Issue 1
    April 2000
    Completing Installation and Cable Pinouts 
    2-8 TN464E/F Option Settings 
    2
    Figure 2-3. TN464E/F Option Settings Figure Notes
    1. TN464E/F DS1/E1 Interfac e
    2. 24/32 Channel Selec tor
    3. 75/120 ohm Selec tor
    4. 32 Channel5. 120 ohm (shown selec ted )
    6. 24 Channel (shown selec ted)
    7. 75 ohm
    3
    4
    5
    1
    6
    2
    7
    tn464_ef RPY 012098 
    						
    							DEFINITY ECS Release 8.2 Installation, Upgrades, 
    and Additions for Compact Modular Cabinets  555-233-118  Issue 1
    April 2000
    Completing Installation and Cable Pinouts 
    2-9 Connector and Cable Diagrams — Pinout Charts 
    2
    Connector and Cable Diagrams — 
    Pinout Charts
    See Table 2-6 for typic al lead  d esig nations. The c irc uit p ac ks and auxiliary 
    eq uip ment are c lassified  as shown in the following  tab les.
    Table 2-6. Lead and Color Designations
    Cross-Connect 
    Pin ColorAmphenol 
    Pin Backplane Pin
    1W-BL26 102
    2 BL-W 01 002
    3 W-O 27 103
    4 O-W 02 003
    5 W-G 28 104
    6 G-W 03 004
    7W-BR29 105
    8BR-W04 005
    9W-SL30 106
    10 SL-W 05 006
    11 R-BL 31 107
    12 BL-R 06 007
    13 R-O 32 108
    14 O-R 07 008
    15 R-G 33 109
    16 G-R 08 009
    17 R-BR 34 110
    18 BR-R 09 010
    19 R-SL 35 111
    20 SL-R 10 011
    21 BK-BL 36 112
    22 BL-BK 11 012
    23 BK-O 37 113
    24 O-BK 12 013
    Continued on next page 
    						
    							DEFINITY ECS Release 8.2 Installation, Upgrades, 
    and Additions for Compact Modular Cabinets  555-233-118  Issue 1
    April 2000
    Completing Installation and Cable Pinouts 
    2-10 Connector and Cable Diagrams — Pinout Charts 
    2
    25 BK-G 38 302
    26 G-BK 13 202
    27 BK-BR 39 303
    28 BR-BK 14 203
    29 BK-SL 40 304
    30 SL-BK 15 204
    31 Y-BL 41 305
    32 BL-Y 16 205
    33 Y-O 42 306
    34 O-Y 17 206
    35 Y-G 43 307
    36 G-Y 18 207
    37 Y-BR 44 308
    38 BR-Y 19 208
    3 9 Y-SL 4 5 3 0 9
    40 SL-Y 20 209
    41 V-BL 46 310
    42 BL-V 21 210
    43 V-O 47 311
    44 O-V 22 211
    45 V-G 48 312
    46 G-V 23 212
    47 V-BR 49 313
    48 BR-V 24 213
    4 9 V-SL 5 0 3 0 0
    50 SL-V 25 200
    Table 2-6. Lead and Color Designations — Continued
    Cross-Connect 
    Pin ColorAmphenol 
    Pin Backplane Pin
    Continued on next page 
    						
    							DEFINITY ECS Release 8.2 Installation, Upgrades, 
    and Additions for Compact Modular Cabinets  555-233-118  Issue 1
    April 2000
    Completing Installation and Cable Pinouts 
    2-11 Connector and Cable Diagrams — Pinout Charts 
    2
    Processor Interface Cable Pinout
     Table 2-7 shows the p inout for the Proc essor Interfac e Cab le.
    Table 2-7. Processor Interface Cable Pinout
    Signal NameProcessor (P1) 
    (Amphenol 
    Connector) AUX (J1)TERM 
    (J3)DCE 
    (J2)Modem 
    (P2)
    ACC48A 40 19
    AP1 (alarm in) 2 26
    AP2 (alarm in) 27 27
    EXTA L M A 5 4 8
    EXTA L M B 3 0 2 3
    XFER4 8 3 8 3 6
    MOD-CTS 21 5
    MOD-DCD 46 8
    MOD-DSR 8 6
    MOD-DTR 7 20
    MOD-GRD 20 1 & 7
    MOD-RTS 34 4
    MOD-RXD 33 3
    MOD-TXD 45 2
    TERM - C TS 9 5
    TERM - D TR 4 7 2 0
    TERM -G RD 3 5 1 &  7
    TERM -RXD 1 0 3
    TERM - TXD 2 2 2
    CDR-CTS 49 5
    CDR-DCD 24 8
    CDR-DSR 12 6
    CDR-DTR 37 20
    CDR-GRD 23 1 & 7
    CDR-RXD 36 3 3
    CDR-TXD 48 2 2
    GRD 25, 50 1-7, 
    11-17, 
    44-461, 7 1, 7 1, 7
    Continued on next page 
    						
    							DEFINITY ECS Release 8.2 Installation, Upgrades, 
    and Additions for Compact Modular Cabinets  555-233-118  Issue 1
    April 2000
    Completing Installation and Cable Pinouts 
    2-12 Connector and Cable Diagrams — Pinout Charts 
    2
    Table 2-8. Port Circuit Pack Lead Designations 
    Cross- 
    Connect 
    PinTN742/B
    TN747B
    TN753 
    TN769 
    TN2147 
    TN465TN754
    TN726TN760/B
    TN760C 
    TN760D
    TN2209 TN762/BTN763 
    TN763B
    TN763C TN735TN767B
    TN464E
    TN2207TN746/B 
    TN2183
    TN793
    TN2793 TN2224/B
    1 T.1 T.1 T.1 T.1 T.1 C_5 T.1 T.1
    2 R.1 R.1 R.1 R.1 R.1 R.1 R.1
    3 TXT. 1 T1 . 1 TXT. 1 SZ . 1 B T. 1 C _EN A B T. 2 T. 2
    4 TXR.1 R1.1 TXR.1 SZ1.1 BR.1 R.2 R.2
    5 PXT. 1 E. 1 PXT. 1 S.1 L T.1 C_SYNC* T.3 T.3
    6 PXR.1 M.1 PXR.1 S1.1 LR.1 R.3 R.3
    7 T.2 T.2 T.2 T.2 T.2 C2D-DATA T.4 T.4
    8 R.2 R.2 R.2 R.2 R.2 RDATA* R.4 R.4
    9 TXT. 2 T1 . 2 TXT. 2 SZ . 2 B T. 2 TD A TA * T. 5
    10 TXR.2 R1.2 TXR.2 SZ1 .2 B R.2 TRSYSN C R.5
    11 PXT.2 E.2 PXT.2 S.2 LT.2 GRD T.6
    12 PXR.2 M.2 PXR.2 S1.2 L R. 2 SC L K* R.6
    13 T.3 T.3 T.3 T.3 T.3 T.7
    14 R.3 R.3 R.3 R.3 R.3 R.7
    1 5 TXT. 3 T1 . 3 TXT. 3 SZ . 3 B T. 3 T. 8
    16 TXR.3 R1.3 TXR.3 SZ1 .3 B R.3 PA H ER* R.8
    1 7 PXT. 3 E. 3 PXT. 3 S. 3 L T. 3 T. 5 T. 9
    18 PXR.3 M.3 PXR.3 S1.3 LR.3 C_48V R.5 R.9
    19 T.4 T.4 T.4 T.4 T.4 T.6 T.10
    20 R.4 R.4 R.4 R.4 R.4 R.6 R.10
    2 1 TXT. 4 T1 . 4 TXT. 4 SZ . 4 B T. 4 C _P2 SC L K T. 7 T. 1 1
    22 TXR.4 R1.4 TXR.4 SZ1.4 BR.4 LI
     (RX) R.7 R.11
    2 3 PXT. 4 E. 4 PXT. 4 S. 4 L T. 4 L O *  ( TX) T. 8 T. 1 2
    24 PXR.4 M.4 PX4.4 S1.4 LR.4 LBACK1 R.8 R.12
    2 5 T. 5 T. 5 T. 5 T. 5 T. 5 G N D T. 9 T. 1 3
    26 R.5 R.5 R.5 R.5 R.5 C _5V R.9 R.13
    2 7 TXT. 5 T1 . 5 TXT. 5 SZ . 5 B T. 5 T. 1 0 T. 1 4
    28 TXR.5 R1.5 TXR.5 SZ1.5 BR.5 R.10 R.14
    2 9 PXT. 5 E. 5 PXT. 5 S. 5 L T. 5 T. 1 1 T. 1 5
    30 PXR.5 M.5 PXR.5 S1.5 L R. 5 C _RST R.11 R.15
    31 T.6 T.6 T.6 T.6 T.6 T.12 T.16
    32 R.6 R.6 R.6 R.6 R.6 R.12 R.16
    3 3 TXT. 6 T1 . 6 TXT. 6 SZ . 6 B T. 6 RD A TA T. 1 7
    34 TXR.6 R1.6 TXR.6 SZ1 .6 B R.6 TD A TA R.17
    3 5 PXT. 6 E. 6 PXT. 6 S. 6 L T. 6 TRSYN C T. 1 8
    36 PXR.6 M.6 PXR.6 S1.6 L R. 6 GRD R.18
    37 T.7 T.7 T.7 T.7 T.7 SCLK T.19
    38 R.7 R.7 R.7 R.7 R.7 R.19
    3 9 TXT. 7 T1 . 7 TXT. 7 SZ . 7 B T. 7 T. 2 0
    Continued on next page 
    						
    							DEFINITY ECS Release 8.2 Installation, Upgrades, 
    and Additions for Compact Modular Cabinets  555-233-118  Issue 1
    April 2000
    Completing Installation and Cable Pinouts 
    2-13 Connector and Cable Diagrams — Pinout Charts 
    2
    * Denotes hig h side of line.
    40 TXR.7 R1.7 TXR.7 SZ1.7 BR.7 R.20
    41 PXT.7 E.7 PXT.7 S.7 LT.7 GRD T.13 T.21
    42 PXR.7 M.7 PXR.7 S1.7 LR.7 R.13 R.21
    4 3 T. 8 T. 8 T. 8 T. 8 T. 8 C _PRES* T. 1 4 T. 2 2
    44 R.8 R.8 R.8 R.8 R.8 R.14 R.22
    4 5 TXT. 8 T1 . 8 TXT. 8 SZ . 8 B T. 8 T. 1 5 T. 2 3
    46 TXR.8 R1.8 TXR.8 SZ1.8 BR.8 DC2_DATA R.15 R.23
    4 7 PXT. 8 E. 8 PXT. 8 S. 8 L T. 8 LI
    *  ( RX) T. 1 6 T. 2 4
    48 PXR.8 M.8 PXR.8 S1.8 L R. 8 LO ( TX) R.16 R.24
    49 GRD GRD GRD GRD GRD GRD LBACK2 GRD GRD
    50 GRD GRD GRD GRD GRD GRD GRD GRD GRD
    Table 2-9. DS1 Interface Cable H600-307 (and C6C)
    50-Pin 15-Pin
    Pin Color Designation Pin Color Designation
    02 W-BL
    03 BL-W
    47 W-G LI (High)
    11 W-G LI (High)
    22 G-W LI
    03 G-W LI
    48 W-BR LO 09 W-BR LO
    23 BR-W LO (High)
    01 \BR LO (High)
    49 W-SL LOOP2 06 W-SL LOOP2
    24 SL-W LOOP1 05 SL-W LOOP1
    All other pins are empty.
    Table 2-8. Port Circuit Pack Lead Designations  — Continued
    Cross- 
    Connect 
    PinTN742/B
    TN747B
    TN753 
    TN769 
    TN2147 
    TN465TN754
    TN726TN760/B
    TN760C 
    TN760D
    TN2209 TN762/BTN763 
    TN763B
    TN763C TN735TN767B
    TN464E
    TN2207TN746/B 
    TN2183
    TN793
    TN2793 TN2224/B
    Continued on next page 
    						
    							DEFINITY ECS Release 8.2 Installation, Upgrades, 
    and Additions for Compact Modular Cabinets  555-233-118  Issue 1
    April 2000
    Completing Installation and Cable Pinouts 
    2-14 Connector and Cable Diagrams — Pinout Charts 
    2
    Table 2-10 shows the p inouts for the TN2185 ISDN-BRI 4-wire S Interfac e. 
    Table 2-10. TN2185 ISDN-BRI — 4-Wire S Interface Pinout
    Port Signal Cross-Connect Pin  Color Amphenol Pin  Backplane  Pin
    1 TXT.1 1 W-BL 26 102
    TXR.1 2 BL-W 01 002
    PXT.1 3 W-O 27 103
    PXR.1 4 O-W 02 003
    2 TXT.2 5 W-G 28 104
    TXR.2 6 G-W 03 004
    PXT. 2 7 W-B R 2 9 1 0 5
    PXR. 2 8 BR- W 0 4 0 0 5
    3 TXT.3 9 W-SL 30 106
    TXR.3 10 SL-W 05 006
    PXT.3 11 R-BL 31 107
    PXR.3 12 BL-R 06 007
    4 TXT.4 13 R-O 32 108
    TXR.4 14 O-R 07 008
    PXT. 4 1 5 R-G 3 3 1 0 9
    PXR. 4 1 6 G - R 0 8 0 0 9
    5 TXT.5 17 R-BR 34 110
    TXR.5 18 BR-R 09 010
    PXT. 5 1 9 R- SL 3 5 1 1 1
    PXR. 5 2 0 SL - R 1 0 0 1 1
    6 TXT.6 21 BK-BL 36 112
    TXR.6 22 BL-BK 11 012
    PXT.6 23 BK-O 37 113
    PXR.6 24 O-BK 12 013
    7 TXT.7 25 BK-G 38 302
    TXR.7 26 G-BK 13 202
    PXT. 7 2 7 B K- B R 3 9 3 0 3
    PXR. 7 2 8 B R- B K 1 4 2 0 3
    8 TXT.8 29 BK-SL 40 304
    TXR.8 30 SL-BK 15 204
    PXT. 8 3 1 Y- BL 4 1 3 0 5
    PXR.8 32 BL-Y 16 205 
    						
    All Lucent Technologies manuals Comments (0)