    Have a look at the manual Lucent Technologies DEFINITY Enterprise Communication Server Release 8.2 Installation, Upgrades, And Additions For Compact Modular Cabinets Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 413 Lucent Technologies manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.

    							DEFINITY ECS Release 8.2 Installation, Upgrades, 
    and Additions for Compact Modular Cabinets  555-233-118  Issue 1
    April 2000
    Installing and Cabling the Cabinets 
    1-75 Install and Wire Telephones and Other Equipment 
    1
    Install Attendant Console — Optional
    1. Position the attend ant c onsole in the d esired  loc ation and  c onnec t the 
    mod ular c ord  to the information outlet.
    2. Install lab els p er the Attend ant Console form and  Disp lay Mod ule form 
    assig nments.
    3. Install a Digital Line c irc uit p ac k in the assig ned  c arrier slot (if required ).
    4. Ad minister the Attend ant Console forms in DEFINITY Enterp rise 
    Communic ations Server Release 8 Ad ministrator’s Guid e.
    Hard-Wire Bridging
    !CAUTION:
    Bridg ing  or p aralleling  these end p oints c an c ause elec tric al d amag e to the 
    c onsoles or c ause the c irc uit p ac k to remove p ower from the c onsoles.
    Analog  type hard -wire b rid g ing  is not allowed  for 4-wire (only) DCP end p oints. 
    This is because hard-wire bridging provides no way of combining the digital 
    output of 2 bridged DCP sets. Also, a bridged endpoint causes the added load 
    to degrade the DCP signal. 
    Dual Wiring of 2-Wire and 4-Wire Endpoints
    Do not simultaneously wire a 2-wire and  4-wire end p oint to the same eq uip ment 
    loc ation in an MDF, even though they c onnec t to d ifferent c olored  wire pairs. The 
    system uses sep arate c irc uit p ac ks to interfac e 2- and  4-wire end p oints, and  
    none are c ap ab le of interfac ing both.
    Install 26B1 Selector Console — Optional
    1. Connec t the sup plied  3-foot (0.9 m) D8AC c ab le to the mod ular jac k on 
    the b ottom of the 26B1 Selec tor Console. 
    2. Route the c ab le to the attend ant c onsole and  c onnec t to the DXS/BLF 
    jac k.
    3. Attac h labels ac c ord ing  to the Attend ant Console form.
    4. Ad minister the c onsole using  DEFINITY Enterp rise Communic ations 
    Server Release 8 Administrator’s Guide. 
    						
    							DEFINITY ECS Release 8.2 Installation, Upgrades, 
    and Additions for Compact Modular Cabinets  555-233-118  Issue 1
    April 2000
    Installing and Cabling the Cabinets 
    1-76 Connect External Alarms and Auxiliary Connections 
    1
    Connect External Alarms and 
    Auxiliary Connections
    NOTE:
    The AUX c onnec tor is p art of the Proc essor Interfac e c ab le assemb ly (J1).
    Alarm Input
    Alarms c an b e g enerated  on ad junc t eq uip ment, sent to the DEFINITY System, 
    and  rec ord ed  and  rep orted  as “ external alarms.”  A typ ic al major alarm inp ut is 
    from a UPS.
    1. Connec t 1 major alarm inp ut wire p air and  1 minor alarm inp ut wire p air to 
    the auxiliary field  from the AUX c onnec tor (J1 on Proc essor Interfac e 
    Cab le). See Table 1-14
    .
    Alarm Output
    The system provides a relay contac t that can operate a customer-provided 
    alarm, suc h as a lig ht or b ell. The c irc uitry and  p ower sourc e are c ustomer- 
    provided. The alarm device must not exc eed a rating of more than 30 VAC RMS 
    or 60 VDC at 0.75 Amp s. 
    1. Connec t the external alarm outp ut. See Table 1-15
    .
    2. Give this information to your Luc ent Tec hnologies rep resentative for 
    troub leshooting  p urp oses.
    Table 1-14. Alarm Inputs at AUX Connector
    Alarm Input Type Color AUX Connector
    Major White-Blue AP1 (Pin 26) 
    Blue-White Ground  (Pin 1)
    Minor White-Orang e AP2 (Pin 27) 
    Orang e-White Ground  (Pin 2)
    Table 1-15. Alarm Output at AUX Connector
    Alarm Output Type Color AUX Connector
    EXTALMA Violet-Green (Pin 48)
    EXTALMB Green-Violet Ground  (Pin 23) 
    						
    							DEFINITY ECS Release 8.2 Installation, Upgrades, 
    and Additions for Compact Modular Cabinets  555-233-118  Issue 1
    April 2000
    Installing and Cabling the Cabinets 
    1-77 Telephone Pin Designations 
    1
    Emergency Transfer and Auxiliary Power
    NOTE:
    Only 1 emerg enc y transfer p ower p anel and  1 auxiliary power c onnec tion is 
    provided per system.
    Connec t emerg enc y transfer p ower and  auxiliary p ower as shown in Table 1-16
    . 
    Auxiliary p ower inc ludes power to an attend ant c onsole or ad junc t devic e.  
    Telephone Pin Designations
    Table 1-17 p rovid es p ort c irc uit p ac k and  telep hone p in d esignations.
    Table 1-16. Emergency Transfer and Auxiliary Power
    Power Type Color AUX Connector
    Emerg enc y Transfer Blac k-Blue  XFER48 (Pin 36)
    Blue-Blac k Ground  (Pin 11)
     Auxiliary (Ad junc t) 
    -48 VDCBrown-Yellow ACC48A (Pin 19)
    Yellow-Brown Ground  (Pin 44)
    Table 1-17. Port Circuit Pack and Telephone Pin Designations
    Pin on 
    Modular 
    Plug4-wire; 302C1, 
    8400-Series, 
    603E, 9403, 
    94342-wire; 302C1, 
    8400-Series, 603E, 
    9403, 9410, 94348510T BRI 
    (with adjunct 
    speaker 
    phone)Analog Station, 
    ModemZ3A1 & Z3A2 
    ADU, Data 
    Module 
    1TXT TXT
    2TXR T TXR
    3 PXT TXT R PXT
    4 T PXR
    5 R PXT
    6 PXR TXR PXR
    7 -48VDC (-48VDC) (-48VDC)
    8GRD GRD GRD
    circuit 
    pack4-wire d ig ital 
    (8 port)2-wire d igital (16 or 24 
    port)4-wire BRI 
    Trunk Sid eAnalog  line (16 
    or 24 p ort)Data Line
    PX PBX transmit T Tip (A)
    TX Terminal transmit R Ring(B) 
    						
    							DEFINITY ECS Release 8.2 Installation, Upgrades, 
    and Additions for Compact Modular Cabinets  555-233-118  Issue 1
    April 2000
    Installing and Cabling the Cabinets 
    1-78 CAMA/E911 Installation 
    1
    CAMA/E911 Installation
    Configuration
    The CAMA/E911 feature will only work on R8 CMC if TN429C CO trunk c irc uit 
    p ac ks (or later suffix) are used .
    Port Networks (PNs) that inc lud e TN429C c irc uit pac ks used  to interfac e to 
    CAMA trunks may require some CPTR resourc es to b e either TN744D V2 or 
    TN2182B c irc uit p ac ks, sinc e TTR/CPTR or General Purp ose Tone Rec eiver 
    (GPTR) resourc es are selec ted  from the p ool availab le in the PN when need ed .
    Hardware Setup
    1. Insert the TN429C or later CO trunk c irc uit pac k in any availab le p ort slot.
    2. Be sure the TN744D Call Classifier - Detec tor c irc uit p ac k is Vintag e 2 or 
    later.
    3. Wire the CAMA trunk to the MDF (the trunk from the CO). Refer to the 
    p inouts in Table 2-13
    .
    Administration Setup
    1. At the promp t, type add trunk next
     and press En t e r.
    Screen 1-3. CAMA Trunk Group form (page 1)
    2. On the Trunk Group  sc reen (p ag e 1), in the Group Type:
     field, enter 
    cama
    .
    3. In the Group Name:
     field , enter the d esired  name. 
    4. In the TAC:
     field , enter the d esired  trunk ac c ess c od e. 
      
                                                                         Page 1 of 11
                                   TRUNK GROUP
    Group Number: 1                  Group Type: cama      CDR Reports: y
      Group Name:  cama Trunk Group - E911  COR: 1     TN: 1       TAC: 701
       Direction: outgoing     Outgoing Display? y CESID I Digits Sent: 0
                                 Busy Threshold: 99
    TRUNK PARAMETERS
             Trunk Type: wink-start
     Outgoing Dial Type: r1mf
      Trunk Termination: rc
                                 
    						
    							DEFINITY ECS Release 8.2 Installation, Upgrades, 
    and Additions for Compact Modular Cabinets  555-233-118  Issue 1
    April 2000
    Installing and Cabling the Cabinets 
    1-79 CAMA/E911 Installation 
    1
    5. In the Outgoing Display:
     field , enter y
    .
    6. In the CESID I Digits Sent:
     field , enter the number d irec ted  b y the 
    Central Offic e (CO) or the Pub lic  Safety Answering Point (PSAP).
    7. Sc roll to p ag e 3 of the form.
    Screen 1-4. Administrable Timers form (page 3)
    8. On the Administrable Timers sc reen (page 3), you may need to adjust 
    these field s ac c ord ing  to your CO. Sc roll to pag e 5.
     
    Screen 1-5. Group Member Assignments form (page 5)
    9. On the Group  Memb er Assig nments sc reen, in the Port
     field , ad d the 
    trunk memb ers and press 
    En t e r when finished .
      
                                                                         Page 3 of 11
                                  TRUNK GROUP
    ADMINISTRABLE TIMERS
                                           Outgoing Disconnect (msec): 400
                                      Cama Outgoing Dial Guard (msec): 75
                                          Outgoing Glare Guard (msec): 1000
                                          Cama Wink Start Time (msec): 5000
     Outgoing End of Dial (sec): 1    Outgoing Seizure Response (sec): 4
                                        Disconnect Signal Error (sec): 30
                                                                        Page 5 of 11
                                    TRUNK GROUP
                                           Administered Members (min/max):  1/2
    GROUP MEMBER ASSIGNMENTS                   Total Administered Members:  2
         Port   Code   Sfx  Name
     1: 01C0401 TN429   C
     2: 01C0402 TN429   C
     3:
     4:
     5:
     6:
     7:
     8:
     9.
     10:
     11:
     12:
     13: 
    						
    							DEFINITY ECS Release 8.2 Installation, Upgrades, 
    and Additions for Compact Modular Cabinets  555-233-118  Issue 1
    April 2000
    Installing and Cabling the Cabinets 
    1-80 CAMA/E911 Installation 
    1
    10. At the promp t, type change feature-access-code
     and press En t e r.
    Screen 1-6. Feature Access Code (FAC) form (page 1)
    11. The Feature Ac c ess Cod e (FAC) sc reen (p ag e 1) ap p ears.
    12. In the Auto Route Selection (ARS) Access Code 1:
     field, 
    ad minister the ARS ac c ess c od e (in the examp le above, typ e 9
    ) and press 
    En t e r  (must matc h d ial p lan).
    13. At the promp t, enter change ars analysis 
      and p ress 
    En t e r.
                                     Page 1 of 5
                                    FEATURE ACCESS CODE (FAC)
                 Abbreviated Dialing List1 Access Code: ____
                 Abbreviated Dialing List2 Access Code: ____
                 Abbreviated Dialing List3 Access Code: ____
    Abbreviated Dial - Prgm Group List Access Code: ____
                              Announcement Access Code: ____
                               Answer Back Access Code: ____
              Auto Alternate Routing (AAR) Access Code: ____
              Auto Route Selection (ARS) Access Code 1: 9___  Access Code 2: ____
                         Automatic Callback Activation: ____   Deactivation: ____
    Call Forwarding Activation Busy/DA: ____ All: ____  Deactivation: ____
                                 Call Park Access Code: ____
                               Call Pickup Access Code: ____
       CAS Remote Hold/Answer Hold-Unhold Access Code: ____
                          CDR Account Code Access Code: ____
    Change Coverage: ____
                          Data Origination Access Code: ____
                              Data Privacy Access Code: ____
    Directed Call Pickup Access Code: ____
             Emergency Access To Attendant Access Code: ____
    Extended Call Fwd Activate Busy D/A: ____  All: ____  Deactivation: ____
                       Facility Test Calls Access Code: ____
                                     Flash Access Code: ____ 
    						
    							DEFINITY ECS Release 8.2 Installation, Upgrades, 
    and Additions for Compact Modular Cabinets  555-233-118  Issue 1
    April 2000
    Installing and Cabling the Cabinets 
    1-81 CAMA/E911 Installation 
    1
    Screen 1-7. ARS Digit Analysis Table
    14. On ARS Dig it Analysis Tab le sc reen app ears. In the Dialed String
     
    field , in the first emp ty row, enter 11
    .
    15. In the Total Mn
     field , enter 2
    .
    16. In the Total Mx
     field , enter 2
    .
    17. In the Rte Pat
     field , enter the d esired  Route Pattern (in the examp le 
    ab ove the route p attern is 11).
    NOTE:
    For the following  step , if you are using the Attend ant Crisis Alerting  
    feature, typ e alrt
     instead  of “ emer.”
    18. In Call Type
     field , enter emer
    .
    19. On the next emp ty row, in the Dialed String
     field , typ e 911
    .
    20. In the Total Mn
     field , enter 3
    .
    21. In the Total Mx
     field , enter 3
    .
    22. In the Rte Pat
     field , typ e the d esired  Route Pattern (in the example 
    ab ove the route p attern is 12).
    NOTE:
    For the following  step , if you are using the Attend ant Crisis Alerting  
    feature, typ e alrt
     instead  of “ emer.”
    23. In the Call Type
     field , enter emer
     and press 
    En t e r.
                                  ARS DIGIT ANALYSIS TABLE
                                Partitioned Group Number:  _     Percent Full:    ___
    Dialed      Total  Rte Call Nd  ANI Dialed      Total  Rte Call Nd ANI
         String      Mn Mx  Pat Type Num Rq String      Mn Mx  Pat Type Num Rq
    9________________ 7_ 7_  2__ hnpa ___ n __________________ __ __ ___ ____ ___ _
    976______________ 7_ 7_  den hnpa ___ n __________________ __ __ ___ ____ ___ _
    11_______________ 2_ 2_  11_ emer ___ n __________________ __ __ ___ ____ ___ _
    911______________ 3_ 3_  12_ emer ___ n __________________ __ __ ___ ____ ___ _
    _________________ __ __  ___ ____ ___ _ __________________ __ __ ___ ____ ___ _
    _________________ __ __  ___ ____ ___ _ __________________ __ __ ___ ____ ___ _
    _________________ __ __  ___ ____ ___ _ __________________ __ __ ___ ____ ___ _
    _________________ __ __  ___ ____ ___ _ __________________ __ __ ___ ____ ___ _
    _________________ __ __  ___ ____ ___ _ __________________ __ __ ___ ____ ___ _
    _________________ __ __  ___ ____ ___ _ __________________ __ __ ___ ____ ___ _
    _________________ __ __  ___ ____ ___ _ __________________ __ __ ___ ____ ___ _
    _________________ __ __  ___ ____ ___ _ __________________ __ __ ___ ____ ___ _
    _________________ __ __  ___ ____ ___ _ __________________ __ __ ___ ____ ___ _
    _________________ __ __  ___ ____ ___ _ __________________ __ __ ___ ____ ___ _
    _________________ __ __  ___ ____ ___ _ __________________ __ __ ___ ____ ___ _ 
    						
    							DEFINITY ECS Release 8.2 Installation, Upgrades, 
    and Additions for Compact Modular Cabinets  555-233-118  Issue 1
    April 2000
    Installing and Cabling the Cabinets 
    1-82 CAMA/E911 Installation 
    1
    24. At the p rompt, typ e change route-pattern 
     
    (the route pattern to 
    b e c hanged ; in the examp le b elow, the route pattern is 11) and  p ress 
    En te r.
    Screen 1-8. Route Pattern form (Page 1)
    25. On the Route Pattern sc reen, in Grp. No
    . field , enter the CAMA trunk 
    g roup number.
    26. In the FRL
     field , enter 0
    .
    NOTE:
    For the following  step , if the Central Offic e (CO) wants KP11ST as 
    the d ialed dig it string , then leave b lank.  If the CO wants KP911ST, 
    then insert a “ 9”  in the Inserted Digits
     field .
    27. Ad minister the Inserted Digits
     field  if need ed  and  p ress 
    En t e r.
                          Page 1 of X
      Pattern Number: 11               
        Grp.  FRL NPA Pfx Hop Toll No. Del Inserted                             IXC
        No.           Mrk Lmt List Digits  Digits
     1: 1__   0  ___  _  __   __    __    ____________________________________ user
     2: ___   _  ___  _  __   __    __    ____________________________________ user
     3: ___   _  ___  _  __   __    __    ____________________________________ user
     4: ___   _  ___  _  __   __    __    ____________________________________ user
     5: ___   _  ___  _  __   __    __    ____________________________________ user
     6: ___   _  ___  _  __   __    __    ____________________________________ user
    BCC VALUE  TSC CA-TSC   ITC BCIE Service/Feature           Numbering LAR
    0 1 2 3 4 W    Request                                       Format
      1: y y y y y n  y none_____ both ept  outwats-bnd____ BAND: ___ ________  none
      2: y y y y y n  n           rest      _______________           ________  next
      3: y y y y y n  n           rest      _______________           ________  rehu
      4: y y y y y n  n           rest      _______________           ________  none
      5: y y y y y n  n           rest      _______________           ________  none
      6: y y y y y n  n           rest      _______________           ________  none 
    						
    							DEFINITY ECS Release 8.2 Installation, Upgrades, 
    and Additions for Compact Modular Cabinets  555-233-118  Issue 1
    April 2000
    Installing and Cabling the Cabinets 
    1-83 CAMA/E911 Installation 
    1
    28. At the p rompt, typ e change route-pattern 
      (the route pattern to 
    b e c hanged ; in the examp le b elow, the route pattern is 12) and  p ress 
    En te r.
    Screen 1-9. Route Pattern form (Page 1)
    29. On the Route Pattern sc reen, in Grp. No
    . field , typ e the CAMA trunk 
    g roup number and  p ress 
    En te r.
    30. In the FRL
     field , typ e 0
    .
    NOTE:
    For the following  step , if the Central Offic e (CO) wants KP911ST as 
    the d ialed dig it string , then leave b lank.  If the CO wants KP11ST, 
    then d elete one d ig it.
    31. Ad minister No. Del Digits
     field  if need ed  and  p ress 
    En t e r.
    32. At the promp t, type change cama-numbering
     and press 
    En t e r.
                          Page 1 of X
      Pattern Number: 12               
        Grp.  FRL NPA Pfx Hop Toll No. Del Inserted                             IXC
        No.           Mrk Lmt List Digits  Digits
     1: 1__   0  ___  _  __   __    1_    ____________________________________ user
     2: ___   _  ___  _  __   __    __    ____________________________________ user
     3: ___   _  ___  _  __   __    __    ____________________________________ user
     4: ___   _  ___  _  __   __    __    ____________________________________ user
     5: ___   _  ___  _  __   __    __    ____________________________________ user
     6: ___   _  ___  _  __   __    __    ____________________________________ user
    BCC VALUE  TSC CA-TSC   ITC BCIE Service/Feature           Numbering LAR
    0 1 2 3 4 W    Request                                       Format
      1: y y y y y n  y none_____ both ept  outwats-bnd____ BAND: ___ ________  none
      2: y y y y y n  n           rest      _______________           ________  next
      3: y y y y y n  n           rest      _______________           ________  rehu
      4: y y y y y n  n           rest      _______________           ________  none
      5: y y y y y n  n           rest      _______________           ________  none
      6: y y y y y n  n           rest      _______________           ________  none 
    						
    							DEFINITY ECS Release 8.2 Installation, Upgrades, 
    and Additions for Compact Modular Cabinets  555-233-118  Issue 1
    April 2000
    Installing and Cabling the Cabinets 
    1-84 CAMA/E911 Installation 
    1
    Screen 1-10. CAMA Numbering Format form
    33. In the CAMA Numb ering  - E911 Format sc reen (p ag e 1), in System 
    CESID Default:
     field , enter your own system d efault and p ress 
    En t e r.  
    This is the numb er outp ulsed  when the extension c od e is not found in the 
    CAMA Numb ering  tab le. See Screen 1-10
    .
    34. In the Ext Len
    , Ext Code
    , CESID
    , and  Total Length
     field s, fill out to 
    your own CAMA numb ering  p lan and  p ress 
    En te r. Be sure to c over all 
    extensions.
    35. At the promp t, typ e change cor 
     
    (the c lass of restriction (COR) 
    to be changed) and press 
    En t e r. Chang e all CORs that are defined  for 
    stations in ord er to remove any c alling  p arty restric tions for 911 c alls.
                                                                         Page 1 of 3
                             CAMA NUMBERING - E911 FORMAT
    System CESID Default: 5241100______
    Ext  Ext                   Total         Ext  Ext                   Total
    Len Code      CESID      Length         Len  Code      CESID      Length
    4_  101__  5381234_____    7_             __  _____  __________     __
    4_  1____  555_________    7_             __  _____  ___________    __
    __  _____  ____________    __             __  ______ ___________    __
    __  _____  ____________    __             __  ______ ___________    __
    __  _____  ____________    __             __  ______ ___________    __
    __  _____  ____________    __             __  ______ ___________    __
    __  _____  ____________    __             __  ______ ___________    __
    __  _____  ____________    __             __  ______ ___________    __
    __  _____  ____________    __             __  ______ ___________    __
    __  _____  ____________    __             __  ______ ___________    __
    __  _____  ____________    __             __  ______ ___________    __
    __  _____  ____________    __             __  ______ ___________    __ 
    						
    All Lucent Technologies manuals Comments (0)

    Related Manuals for Lucent Technologies DEFINITY Enterprise Communication Server Release 8.2 Installation, Upgrades, And Additions For Compact Modular Cabinets Manual