    Have a look at the manual Lucent Technologies DEFINITY Enterprise Communication Server Release 8.2 Installation, Upgrades, And Additions For Compact Modular Cabinets Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 413 Lucent Technologies manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.

    							DEFINITY ECS Release 8.2 Installation, Upgrades, 
    and Additions for Compact Modular Cabinets  555-233-118  Issue 1
    April 2000
    Adding or Removing Hardware 
    4-29 Add IP Interface Assembly 
    4
    NOTE:
    The c ustomer provid es the IP add ress, sub net mask, and  g ateway 
    address.
    At this time the TN802B LCD read s PC BOOT *
    , and  ab out 3 to 4 minutes 
    later read s MEDPRO *
     with the asterisk flashing
    .
    Test the External Connection to the LAN
    To test the external IP c onnec tions, p ing the IP Interfac e server, and  p ing  a 
    known c omp uter c onnec ted  to your network. If everything  is c onfig ured c orrec tly, 
    the Result
     c olumn on the Ping  Results sc reen read s pass
    . If it read s abort
    , 
    verify the IP-ad d ress information and  c hec k the c onnec tivity, inc lud ing  the 
    cabling.
    1. Type ping ip-address 
    nnn.nnn.nnn.nnn board UUCSS and p ress En t e r. 
    Th e  v a r i a b l e  
    nnn.nnn.nnn.nnn is the IP ad d ress of the TN802B IP 
    Interfac e and  
    UUCSS is the c ab inet, c arrier, and  slot of the TN802B IP 
    Interfac e.
    change ip-interfaces                                            Page   1 of   2 
                                                                                    
     Network regions are interconnected?  n
      En-                                                                        Net
     abled Type   Slot  Code Sfx Node Name       Subnet Mask     Bcast/Gway 
    Addr Rgn
       n   C-LAN  01A09 TN799    clan-a1         255.255.255.0   192.168.1 .100 1 
    y  MEDPRO 01A13 TN802  B med-a1  255.255.255.0  192.168.1 .21  1 
       n                                         255.255.255.0      .   .   .      
       n                                         255.255.255.0      .   .   .      
       n                                         255.255.255.0      .   .   .      
       n                                         255.255.255.0      .   .   .      
       n                                         255.255.255.0      .   .   .      
       n                                         255.255.255.0      .   .   .      
       n                                         255.255.255.0      .   .   .      
       n                                         255.255.255.0      .   .   .      
       n                                         255.255.255.0      .   .   .      
       n                                         255.255.255.0      .   .   .      
       n                                         255.255.255.0      .   .   .      
       n                                         255.255.255.0      .   .   .      
       n                                         255.255.255.0      .   .   .       
    						
    							DEFINITY ECS Release 8.2 Installation, Upgrades, 
    and Additions for Compact Modular Cabinets  555-233-118  Issue 1
    April 2000
    Adding or Removing Hardware 
    4-30 Add IP Interface Assembly 
    4
    2. Type ping ip-address nnn.nnn.nnn.nnn board UUCSS and p ress En t e r. 
    Th e  v a r i a b l e  
    nnn.nnn.nnn.nnn is the IP ad d ress of the c ustomer’s 
    g ateway and  
    UUCSS is the c ab inet, c arrier, and  slot of the TN802B IP 
    Interfac e.
    3. Type ping ip-address 
    nnn.nnn.nnn.nnn board UUCSS and p ress En t e r. 
    Th e  v a r i a b l e  
    nnn.nnn.nnn.nnn is the IP ad d ress of another c omp uter 
    b eyond  the g ateway and  
    UUCSS is the c ab inet, c arrier, and  slot of the 
    TN802B IP Interfac e.
    The TN802B IP Interfac e is now installed  in the DEFINITY c arrier and  c onnec ted  
    to the IP network.
    Installing in IP Trunk Mode
    NOTE:
    IP Trunk mod e should  only b e used  to maintain c omp atib ility with existing  
    Release 7 IP Trunk or ITS-E installations. We strong ly rec ommend  that 
    Med Pro mod e b e used  whenever p ossib le.
    Prepare for Installation
    Have the following  eq uip ment on site b efore your ship ment arrives:
    nA mouse, keyboard , and  VGA monitor for use d uring  the installation of the 
    server. You also need  AC p ower outlets for the mod em and monitor.
    nThree ad joining , unoc c up ied  p ort slots in the DEFINITY ECS
    The TN802B IP Interfac e slid es into only 1 slot, b ut its fac ep late oc c up ies 
    3 slots.
    nA 10 BaseT or 10/100 BaseT Ethernet c onnec tion into the c ustomer’s loc al 
    area network (LAN)
    nA valid , unused IP ad d ress on the c ustomer’s LAN that c an b e assig ned  to 
    the IP Interfac e server. You also need  the sub net mask, d efault g ateway, 
    d omain name, and  so forth from the c ustomer’s network ad ministrator.
    nAn analog telep hone line reserved  for the IP Interfac e d iag nostic  mod em
    ping ip-address 192.168.10.21                                                   
                                                                                    
                              PING RESULTS
      End-pt IP        Port      Port Type  Result    Time(ms)  Error Code
      192.168.10.21    01A13 MEDPRO PASS  10 1124  
    						
    							DEFINITY ECS Release 8.2 Installation, Upgrades, 
    and Additions for Compact Modular Cabinets  555-233-118  Issue 1
    April 2000
    Adding or Removing Hardware 
    4-31 Add IP Interface Assembly 
    4
    nA valid  telep hone numb er reserved  for the IP Interfac e d iag nostic  mod em
    If non-U.S. c ustomer:
    nMod em c omp arab le to a U.S. Rob otic s, Inc . Sp ortster Mod el USR 33.6 
    EXT.
    nA c ab le from the mod em to the TN802B external c ab le assemb ly.
    We rec ommend  that you p rotec t the c ab inet where the IP Interfac e is installed  
    with an uninterrup tib le p ower system (UPS).
    Check your Shipment
    When your DEFINITY Med ia Proc essor ord er arrives at the c ustomer’s site, c hec k 
    the c ontents (see Table 4-6
    ).
    1. Insp ec t the ship p ing  c arton for d amag e b efore op ening  it. If the b ox is 
    damaged, do not open it. Inform the ship p ing  c omp any, and  ask for 
    instruc tions on filing a c laim.
    2. If the b ox is und amag ed , c hec k the c ontents ag ainst the p ac king  slip . 
    Chec k the c ondition of eac h c omp onent, and note any d amag e or 
    shortag es on the p ac king  slip . The c arton should  c ontain the following  for 
    eac h IP Interfac e ord ered :
    .
    The TN802B external c ab le assemb ly is a bund le of c ab les with an amp henol 
    c onnec tor at the end  of the b und le and  various PC-typ e c onnec tors (VGA, 
    Universal Serial Bus [ USB] , mouse, keyb oard , Ethernet, mod em, and  COM2) at 
    the end s of the ind ivid ual c ab les. See Figure 4-7
    . Look for the lab el where the 
    b und le enters the amp henol c onnec tor.
    Table 4-6. Required Hardware
    Comcode/Code Description Quantity
    J58890MA-1 L30 TN802B IP Interfac e Assemb ly
    1
    601939804 H600-512,G1 external c ab le assemb ly 1
    407633999 U.S. Rob otic s Sp ortster external 
    mod em, mod el numb er USR 33.6 EXT 
    (U.S. c ustomers only) 
    1
    1. For non-U.S. customers, you need  a mod em c omparable to the U.S. Rob otic s
    Sp ortster and a serial c able. 
    1
    601087091 20-ft DB-25 serial c ab le from modem 
    to TN802B external c ab le assemb ly 
    (U.S. c ustomers only) 
    2
    1 
    						
    							DEFINITY ECS Release 8.2 Installation, Upgrades, 
    and Additions for Compact Modular Cabinets  555-233-118  Issue 1
    April 2000
    Adding or Removing Hardware 
    4-32 Add IP Interface Assembly 
    4
    Figure 4-7. TN802B IP Interface External Cable Assembly
    3. Read  and  follow any d irec tions inserted  into the p ac kag e b y the fac tory.
    Connect the Cables
    1. Determine into whic h p ort slot you are p utting  the TN802B IP Interfac e.
    NOTE:
    Make sure that at least 3 ad joining  slots are free.
    2. From the rear of the c ab inet, c onnec t the amp henol c onnec tor on the 
    external c ab le assemb ly to the b ac kp lane c onnec tor c orrespond ing  to 
    that slot (the hig hest numbered  c onnec tor of the 3 slots required ). Figure Notes
    1. Amp henol c onnec tor to c onnec tor 
    c orresp ond ing  to TN802B slot
    2. To VGA monitor
    3. To USB (not used )
    4. To keyb oard5. To mouse
    6. To ethernet
    7. 25-p in male c onnec tor to mod em
    8. 25-p in male c onnec tor to COM2 
    cbdfocto AWF 122398
    2
    1
    345678 
    						
    							DEFINITY ECS Release 8.2 Installation, Upgrades, 
    and Additions for Compact Modular Cabinets  555-233-118  Issue 1
    April 2000
    Adding or Removing Hardware 
    4-33 Add IP Interface Assembly 
    4
    Connect the Modem
    NOTE:
    These instruc tions are for c onnec ting  the U.S. Rob otic s modem sup p lied  to 
    U.S. c ustomers only. If using  a d ifferent mod em, follow the manufac turer’s 
    instruc tions on c onnec ting  the mod em.
    1. Connec t the RS232 p ort of the mod em to the MODEM c onnec tor of the 
    TN802B external c ab le assembly. 
    NOTE:
    Chec k the lab els near the c onnec tors; the MODEM and  COM2 
    c onnec tors look the same.
    2. Connec t an analog  telephone line to the leftmost analog -line p ort on the 
    mod em as shown in Figure 4-8
    . 
    3. Make sure that the mod em’s DIP switc hes are set as shown in 
    Figure 4-8
     and Table 4-7. 
    4. Plug  the mod em into an AC p ower outlet.
    5. Turn on the mod em using  the switc h on the front of the mod em.
    Figure 4-8. External Modem Connections for U.S. Robotics Sporster Figure Notes
    1. Connec t analog  line here.
    2. DIP switc h 5 must b e up .3. Connec t MODEM c onnec tor here.
    4. Connec t p ower c onnec tor here.
    12345678
    modfrobo KLC 030499
    234
    1 
    						
    							DEFINITY ECS Release 8.2 Installation, Upgrades, 
    and Additions for Compact Modular Cabinets  555-233-118  Issue 1
    April 2000
    Adding or Removing Hardware 
    4-34 Add IP Interface Assembly 
    4
    Connect the Monitor, Keyboard, and Mouse
    NOTE:
    Only make these c onnec tions if ad ministered  loc ally. Not nec essary if 
    ad ministered  remotely.
    You must c onnec t these b efore inserting  the TN802B IP Interfac e.
    1. Attac h a VGA monitor to the VGA c onnec tor of the TN802B IP Interfac e 
    external c ab le assemb ly.
    2. Attac h the keyb oard  to the KEYBOARD c onnec tor of the external c ab le 
    assemb ly.
    3. Attach the mouse to the MOUSE connector of the external c able 
    assemb ly.
    4. Plug  the monitor into an AC p ower rec ep tac le and  turn it on.
    Table 4-7. U.S. Robotics Modem Dip Switch Settings
    Dip 
    Switch Setting Description
    1UP
    DOWNData Terminal Read y normal
    Data Terminal Read y overrid e
    2UP
    DOWNVe r b a l  r e s u lt  c o d e s
    Numeric  result c od es
    3UP
    DOWNSuppress result codes
    Disp lay result cod es
    4UP
    DOWNEc ho offline c ommand s
    No ec ho, offline c ommand s
    5UP
    DOWNAuto answer on first ring or higher if specified in NVRAM
    Auto answer off
    6UP
    DOWNCarrier d etec t normal
    Carrier d etec t overrid e
    7UP
    DOWNLoad  NVRAM d efaults
    Load  fac tory d efaults
    8UP
    DOWNDumb  mod e
    Sm a rt  m o d e 
    						
    							DEFINITY ECS Release 8.2 Installation, Upgrades, 
    and Additions for Compact Modular Cabinets  555-233-118  Issue 1
    April 2000
    Adding or Removing Hardware 
    4-35 Add IP Interface Assembly 
    4
    Connect the Ethernet
    1. Connec t the network c ab le to the ETHERNET c onnec tor on the TN802B 
    external c ab le assemb ly.
    NOTE:
    You need  a CAT5 or better c ab le for 100-Mb yte operation.
    Install the Circuit Pack
    !CAUTION:
    When ad d ing  or rep lac ing  any hard ware, b e sure to ground  yourself 
    ag ainst elec trostatic  d isc harge (ESD) b y wearing  a g rounded  wrist strap .
    NOTE:
    The TN802B IP Interfac e is hot-swap p ab le, so you d o not need  to p ower 
    d own the c arrier to install it.
    If you need  to remove the TN802B IP Interfac e from the c arrier at a later 
    time, shut down Wind ows NT first b y p ressing the rec essed reset button on 
    the fac ep late (see Figure 4-9
    ) of the TN802B IP Interfac e until the LCD 
    shows a flashing MSHUT *
    . When the flashing  stop s and  the asterisk 
    d isap p ears (ab out 2 min), it is safe to remove the c irc uit p ac k. 
    						
    							DEFINITY ECS Release 8.2 Installation, Upgrades, 
    and Additions for Compact Modular Cabinets  555-233-118  Issue 1
    April 2000
    Adding or Removing Hardware 
    4-36 Add IP Interface Assembly 
    4
    Figure 4-9. TN802B IP Interface faceplate
    NOTE:
    To p rop erly seat the c irc uit p ac k, p ush firmly on the front of the fac ep late 
    until the latc h reac hes the b ottom rail of the c arrier. Then c lose the latc h 
    until it is fully eng ag ed .
    1. Insert the TN802B IP Interfac e into the rig htmost of the three slots you 
    reserved  for it (see Figure 4-10
    ).
    When you p lug  in the TN802B IP Interfac e, the c irc uit p ac k starts to b oot 
    and  the LCD read s PC Boot 
    then after ab out 3 to 4 minutes it c hang es to 
    IP TRK *
    , the default mod e. Figure Notes
    1. LCD d isp lay
    2. Reset b utton (rec essed )
    3. Red  b oard  status LED4. PCMCIA c ard slot
    5. Yellow PCMCIA d isk-in-use LED
    1
    2
    3
    4
    5
    fpdfmapd KLC 030899 
    						
    							DEFINITY ECS Release 8.2 Installation, Upgrades, 
    and Additions for Compact Modular Cabinets  555-233-118  Issue 1
    April 2000
    Adding or Removing Hardware 
    4-37 Add IP Interface Assembly 
    4
    Figure 4-10. J58890MA-1 L30 IP Interface Assembly
    Test the Modem
    1. Check for dial tone.
    2. Contac t Luc ent Tec hnolog ies Customer Sup p ort and  ask a rep resentative 
    to d ial into your IP Interfac e server. 
    Administer the IP Interface
    Ad minstration is d one either loc ally or remotely. If ad ministered  loc ally, p roc eed  
    with the following  ad minstration step s on the attac hed  keyb oard , mouse, and  
    monitor. If administered  remotely, c all your servic e rep resentative to start the 
    p roc ess.
    Administration Steps
    1. Log in as craft
    .
    2. Type change circuit-pack
     and  p ress 
    En te r.
    456
    789
    1
    0
    1
    11
    21
    3
    1
    41
    51
    6
    indfmapd KLC 031299 
    						
    							DEFINITY ECS Release 8.2 Installation, Upgrades, 
    and Additions for Compact Modular Cabinets  555-233-118  Issue 1
    April 2000
    Adding or Removing Hardware 
    4-38 Add IP Interface Assembly 
    4
    3. Chec k the Cod e c olumn to see if the slots ab ove the TN802B say 
    DSMAPD or MEDPRO.
    .
    4. If MEDPRO, g o to the entry just ab ove the TN802B that says MEDPRO.
    5. Type DSMAPD, and press 
    En te r. Chang ing the one entry automatic ally 
    c hang es the entry ab ove it. If it is in IP Trunk mode, you g et the following 
    error message:
    MedPro type requires TN802 with application. Type 
    MEDPRO on circuit-packs form.
    Log onto the TN802B Interface Server 
    If administered  remotely throug h p c ANYWHERE:
    1. Dial in to the server through pcANYWHERE using the dialup number 
    supplied. 
    2. Clic k on the p c ANYWHERE Remote Host Computer b utton on the toolb ar 
    to send  
    CTRL ALT DEL to the host.
    3. Type administrator
     in the User Name
     field .
    4. Type iptrunk
     in the Password
     field  and  c lic k OK
    . 
    5. After log g ing  on for the first time, c hang e the ad ministrator p assword and , 
    if d esired , the user name, to ensure sec urity. See your Wind ows NT server 
    d oc umentation for d etails.
    If administered  loc ally on a monitor, keyb oard, and  mouse:
    1. Press 
    CTRL, ALT, and  DEL simultaneously.
    2. Type administrator
     in the User Name
     field .
    change circuit-packs                                            Page   1 of   5 
                                  CIRCUIT PACKS                                     
            Cabinet: 1                            Carrier: A
                                             Carrier Type: processor        
     Slot Code  Sf Mode   Name               Slot Code  Sf Mode   Name
    11: DSMAPD RESERVED-IP
    01: TN754  DIGITAL LINE  12: DSMAPD  RESERVED-IP
    02: TN758  POOLED MODEM  13: TN802  B  MAPD BOARD
    03: TN2144  ANALOG LINE  14: 
    04: TN746  B  ANALOG LINE  15: 
    05 16:         
    06: TN771  C  MAINTENANCE/TEST  
    07: TN464  F  DS1 INTERFACE     
    08: TN2140  E&M TIE TRUNK     
    09: TN767  E  DS1 INTERFACE     
    10: TN799  B  CONTROL-LAN       
      # indicates circuit pack conflict. 
    						