    Have a look at the manual Lucent Technologies DEFINITY Enterprise Communication Server Release 8.2 Installation, Upgrades, And Additions For Compact Modular Cabinets Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 413 Lucent Technologies manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.

    							DEFINITY ECS Release 8.2 Installation, Upgrades, 
    and Additions for Compact Modular Cabinets  555-233-118  Issue 1
    April 2000
    Installing and Cabling the Cabinets 
    1-105 Install Emergency Transfer Unit and Associated Telephones 
    1
    Install Telephone for Power Transfer Unit
    Trunk/Auxiliary Field: Telephone Used Only for Emergency Transfer
    1. Connec t a p air of wires b etween the -48V and  GRD terminals on the yellow 
    emergenc y transfer row/c onnec ting  bloc k and  the EM TRANS RELAY PWR 
    terminal. See Figure 1-47
    .
    2. Connec t CO trunk lead s from the p urp le field  to the TC terminals on the 
    yellow emerg enc y transfer row/c onnec ting  b loc k for eac h trunk.
    3. Connec t CO trunk lead s from the g reen field  to the TK terminals on the 
    yellow emerg enc y transfer row/c onnec ting  b loc k for eac h trunk.
    4. Connec t the ST lead s on the yellow emerg enc y transfer row/c onnec ting  
    b loc k for eac h emerg enc y transfer telep hone to the ST terminal 
    ap p earanc e in the yellow trunk/auxiliary field . The ST terminal lead s 
    should  b e terminated  on the following  p airs: 1, 4, 7, 10, 13, 16, 19, or 22 
    (the first pair of any 3-pair group).
    5. Connec t the ST lead s from the terminal in Step  4 to the assig ned  terminal 
    in the b lue or white station d istribution field.
    Trunk/Auxiliary Field: Telephone Used for Emergency Transfer and as 
    Normal Extension
    1. Connec t a p air of wires b etween the -48V and  GRD terminals on the yellow 
    emergenc y transfer row/c onnec ting  b loc k to the EM TRANS RELAY PWR 
    terminal. See Figure 1-48
    .
    2. Connec t CO trunk lead s from the p urp le field  to the TC terminals on the 
    yellow emerg enc y transfer row/c onnec ting  b loc k for eac h trunk.
    3. Connec t CO trunk lead s from the g reen field  to the TK terminals on the 
    yellow emerg enc y transfer row/c onnec ting  b loc k for eac h trunk.
    4. Connec t telep hone lead s from the p urp le analog  line board  row/ 
    c onnec ting b loc k to the LC terminals on the yellow emerg enc y transfer 
    row/c onnec ting  b loc k for eac h telep hone.
    5. Connec t ST lead s on the yellow emerg enc y transfer row/c onnec ting  b loc k 
    for eac h emerg enc y transfer telep hone to the ST terminal ap p earanc e in 
    the p urp le trunk/auxiliary field .
    6. Connec t the ST lead s from the terminal in Step  5 to the assig ned  terminal 
    in the b lue or white station d istribution field.
    Telephone Installation
    1. Connec t the telep hone to the information outlet.
    2. Install p atc h c ord s/jump er wires b etween the system sid e and  the station 
    sid e of the station d istrib ution field  on the MDF.  
    						
    							DEFINITY ECS Release 8.2 Installation, Upgrades, 
    and Additions for Compact Modular Cabinets  555-233-118  Issue 1
    April 2000
    Installing and Cabling the Cabinets 
    1-106 Connect Modem to Telephone Network 
    1
    Connect Modem to Telephone 
    Network
    1. Cross-c onnec t the network jac k on the mod em to the network interfac e 
    (via a 103A or mod ular wall jac k). See Table 1-22
     for the p inout.  
    Figure 1-49. Network Jack on U.S. Robotics Modem
    Table 1-22. Pinout of Network Jack
    Pin Number Signal
    1 Unused
    2Tip 
    3Ring 
    4 Unused
    Figure Notes
    1. Pin 1 of network jac k 2. Mod em
    modmcabl KLC 110397
    OFF ON
    AA CD RD SD C S AR Q/ FAXTR
    Sportster33.6
    Faxmodem
    1
    2 
    						
    							DEFINITY ECS Release 8.2 Installation, Upgrades, 
    and Additions for Compact Modular Cabinets  555-233-118  Issue 1
    April 2000
    Installing and Cabling the Cabinets 
    1-107 Connect Modem to Telephone Network 
    1
    External Modem Option Settings
    The U.S. Rob otic s Sp ortster Mod el USR 33.6 EXT external mod em is the 
    rec ommend ed external mod em for Release 8 CMC. A loc ally ob tained , 
    type-ap p roved  external mod em may b e used . Contac t your Luc ent Tec hnolog ies 
    representative for information. 
    1. If a non-U.S Robotic s Mod el 839 mod em is installed , refer to the setup  
    instruc tions p rovid ed with that mod em. Refer to Table 1-24
     while setting  
    up  the mod em. Go to Step  4 to c omp lete the mod em ad ministration.
    2. If no mod em is installed , skip  to step  5. If a U.S Rob otic s Mod el 839 
    modem is installed, perform the following.
    3. Use Table 1-23
     to set the 8 op tion switc hes on the U.S. Rob otic s mod em.
    4. At the management terminal, type change system-parameters 
    maintenance
     and press 
    En t e r. Sc roll to p ag e 3 of the form. 
    5. Set the Modem Connection: 
    field  to external
     if a mod em is installed . 
    Set the field  to none
     if no mod em is installed . This field must b e 
    ad ministered  or alarms will b e g enerated. 
    NOTE:
    Th e  Modem Connection: 
    field  c annot b e set to none
     if Alarm 
    Orig ination is ac tivated.
    6. Set the Data Bits:
     field to 8
     (d efault).
    7. Set the Parity:
     field  to none 
    (d efault).
    Table 1-23. U.S. Robotics Model 839 External Modem Switch Settings
    Switch Setting Function
    1 OFF (Up ) DTR (Data Terminal Read y) override
    2 OFF (Up ) Verb al result c od es (text-formatted feed b ack charac ters such as c onnec ted  
    or no c arrier)
    3 ON (Down) Enab le result cod es
    4 OFF (Up ) Disp lays keyb oard  command s (loc al echo)
    5 OFF (Up ) Sets auto answer. Verify that the Auto Answer Ring Count (rings): 
    on the maintenance-related  system parameters form is S0= 10.
    6 OFF (Up ) CD (Carrier Detect) overrid e (mod em sends CD signal on c onnec t, drop s 
    CD on d isconnec t)
    7 OFF (Up ) Power-on and ATZ reset software defaults (load s Y or Y1 c onfig uration from 
    NVRAM)
    8 ON (Down) AT (Attention) command  set recog nition (enables rec ognition, smart mod e) 
    						
    							DEFINITY ECS Release 8.2 Installation, Upgrades, 
    and Additions for Compact Modular Cabinets  555-233-118  Issue 1
    April 2000
    Installing and Cabling the Cabinets 
    1-108 Connect Modem to Telephone Network 
    1
    8. For non-United  States installations, set the remaining  mod em field s as 
    shown in Table 1-24
    .
    9. Press 
    En t e r when the mod em field s are p rop erly ad ministered .
    Table 1-24. Release 8 CMC Modem Fields 
    Field Description
    Modem 
    ConnectionDefault is none
     for Release 8 CMC. Set to external
     if a mod em is used .
    Modem Name
    This field  is 20 c harac ters long  and  p ermits alp hanumeric  c harac ters to 
    p rovid e a uniq ue q ualifier for a given mod em.
    RTS/CTS 
    EnabledInforms mod em that c ommunic ation with the d ata sourc e UART is d riven 
    with RTS/CTS flow c ontrol. The d efault 6-c harac ter field name is &H1
    . 
    Set the field  name to \Q3 for Intel mod ems. This field  is not 
    c ase-sensitive.
    Asynchronous 
    Data ModeConfig ures mod em as an async hronous d evic e. This 8-c harac ter field  
    name has a d efault value of &M0
     (d efault) for Release 8 CMC. Set the 
    field  to &M0&Q0 for Intel modems. This field  is not c ase-sensitive. 
    DTE 
    Auto-Data 
    SpeedAd justs the sp eed  of the d ata sourc e (DTE) UART to the outg oing  
    (mod em-to-mod em) d ata rate. At maximum, this sp eed is 9600 b aud . It 
    is not d esirab le to have the serial d ata fill the mod em buffer faster than 
    the outg oing  data rate, sinc e d ata c omp ression is d isab led . The field  
    name has a 6-c harac ter b lank d efault value. The Parad yne produc ts use 
    S90= 1 to enab le this func tionality while the Intel p rod uc t uses \J1 to 
    enab le similar func tionality. This field  is not c ase-sensitive. 
    Disable Data 
    CompressionTurns off the d efault d ata c ompression alg orithms used  b y most 
    mod ems. The field has a b lank field  of 6 c harac ters as d efault. The AT 
    c ommand s that c ontrol this are supp orted  b y similar c ommand s; 
    however, these c ommand s d o not op erate in the same manner. The Intel 
    modems require H0%C0 to disable V.42bis & MNP Class 5 data 
    c omp ression alg orithms. The Parad yne p rod uc ts only use %C0 to 
    d isab le b oth algorithms. This field  is not c ase-sensitive.
    Enable Error 
    ControlTurns on the V.42 LAPM and  MNP error c ontrol p rotoc ols. The field has a 
    b lank d efault of 6 c harac ters. The Parad yne p rod uc ts use the c ommand  
    \N5 to enab le V.42/MNP/Buffer error c ontrol while the Intel p roduc t uses 
    \N3 to p rovid e similar func tionality. 
    Misc. Init. 
    ParamThis field  has a 20-c harac ter b lank d efault and  sup ports any initialization 
    p arameters not alread y sp ec ified . The AT c ommand s sp ec ified  in this 
    field  are always the last initialization p arameters to b e sent to the 
    external mod em. This field  is not c ase-sensitive. 
    Continued on next page 
    						
    							DEFINITY ECS Release 8.2 Installation, Upgrades, 
    and Additions for Compact Modular Cabinets  555-233-118  Issue 1
    April 2000
    Installing and Cabling the Cabinets 
    1-109 Connect Modem to Telephone Network 
    1
    Auto-Answer 
    Ring NumberThis field  c ontrols the number of ring s required  b efore the mod em 
    answers an inc oming  c all. This field  should  b e set to S0= 10.
    Dial Type
    This field  c ontrols the typ e of interreg ister sig naling  used  b etween the 
    mod em and  the CO. This 3-c harac ter field  is d enoted  b y “ T”  for tone 
    dialing (default) and “P” for pulse dialing. This setting depends on type 
    of line (tone or p ulse) to the mod em.
    Adjustable 
    Make/Break 
    RatioThis field  c ontrols the make/b reak ratios of p ulses and  DTMF d ialing . 
    Most mod ems have sup p ort for d ifferent make/ b reak op tions for p ulse 
    d ialing  only. Parad yne, Intel, and  U.S. Rob otic s use the d efault &P0
     to 
    selec t a ratio of 39% make and  61% break for c ommunic ation for the 
    United  States and  Canad a. The op tion &P1 sets a ratio of 33% make and 
    67% break for the United Kingdom and Hong Kong. This is a 
    5-c harac ter b lank field  (d efault) and  is not c ase-sensitive. 
    Dial Command
    This field  has a d efault of “ D”  in a 3-c harac ter field . This field  d enotes the 
    stand ard  d ialing  c ommand  of the mod em and  is not c ase-sensitive. 
    No Answer 
    Time-OutMost mod ems provide a timer that ab andons any outb ound  d ata c all 
    after a p red etermined  interval. This is a non-ad ministrab le parameter. 
    Table 1-24. Release 8 CMC Modem Fields  — Continued
    Field Description
    Continued on next page 
    						
    							DEFINITY ECS Release 8.2 Installation, Upgrades, 
    and Additions for Compact Modular Cabinets  555-233-118  Issue 1
    April 2000
    Installing and Cabling the Cabinets 
    1-110 Connect Modem to Telephone Network 
    1 
    						
    							Completing Installation and Cable Pinouts 
    2-1 Perform System Administration 
    2
    DEFINITY ECS Release 8.2 Installation, Upgrades, 
    and Additions for Compact Modular Cabinets  555-233-118  Issue 1
    April 2000
    2
    Completing Installation and Cable 
    Pinouts
    Perform System Administration
    NOTE:
    Some of the interfac e units used  b etween the system and  other typ es of 
    eq uip ment req uire sp ec ific  c onfiguration setting s and  ad ministration for 
    eac h ap p lic ation. Refer to the user’s g uide for eac h eq uip ment typ e for 
    information on how to loc ate and  set the c onfig uration and  op tion switc hes.
    1. Ad minister the system b y ad d ing  the c ustomer d ata to matc h the wiring , 
    telep hones, and  other eq uip ment. See DEFINITY Enterp rise 
    Communic ations Server Release 8 Ad ministrator’s Guid e. 
    2. Return to this sec tion when finished .
    NOTE:
    Refer to DEFINITY Enterp rise Communic ations Server Release 8 Installation 
    for Ad junc ts and  Perip herals, for data module and other peripheral 
    installation and  c onfig uration req uirements. 
    Resolve Alarms
    1. Examine the alarm log . Resolve any alarms using  DEFINITY Enterp rise 
    Communic ations Server Release 8 Maintenanc e for R8c si.
    2. Refer to ‘‘Power Supply LED Indications’’ on page 2-4
     if power supply 
    faults are susp ec ted. 
    						
    							DEFINITY ECS Release 8.2 Installation, Upgrades, 
    and Additions for Compact Modular Cabinets  555-233-118  Issue 1
    April 2000
    Completing Installation and Cable Pinouts 
    2-2 Perform System Administration 
    2
    Enable Alarm Origination to INADS
    No External Modem Installed (or No Alarm Origination to INADS)
    1. Type change system-parameters maintenance
     and press En t e r. 
    2. Type n
     in the Alarm Orig ination Ac tivated  to OSS Numb ers field  and p ress 
    En t e r . 
    3. For some software releases, enab le Cleared  Alarm Notific ation and  
    Restart Notific ation before the sub mitting  the form.
    External Modem Installed
    1. Type change system-parameters maintenance
     and press En t e r. 
    2. Type y
     in the Alarm Orig ination Ac tivated  to OSS Numb ers field and  p ress 
    En t e r . 
    3. For some software releases, enab le Cleared  Alarm Notific ation and  
    Restart Notific ation before the sub mitting  the form.
    4. Be sure the system is p art of the INADS d atabase b y c alling  the INADS 
    Datab ase Administrator at the Tec hnic al Servic e Center (TSC). Verify that 
    INADS c an d ial into the system and  that the system c an d ial out to INADS. 
    As p art of the system reg istration proc ess, the INADS Datab ase 
    Ad ministrator enab les Alarm Orig ination and  c ustomer op tions.
    NOTE:
    When c alling  from a remote mod em, you may need  to d isab le error 
    c orrec tion to allow the mod ems to c onnec t suc c essfully. For 
    examp le, the AT&T Parad yne Keep InTouc h
    ® mod em may req uire the 
    “ AT\n0”  c ommand .
    5. Log  off and  log  b ac k in.
    Place a Test Call
    1. From any telep hone c onnec ted  to a dig ital line c irc uit p ac k, c all any 
    nearb y telep hone c onnec ted  to an analog  line c irc uit p ac k.
    2. Verify that the dial tone, ring ing pattern, and  talk p ath are ac c ep tab le.
    3. Plac e a c all throug h the Central Offic e (outsid e c all) to any nearb y 
    telep hone. Verify that the d ial tone, ringing  p attern, and talk p ath are 
    ac c ep tab le. 
    						
    							DEFINITY ECS Release 8.2 Installation, Upgrades, 
    and Additions for Compact Modular Cabinets  555-233-118  Issue 1
    April 2000
    Completing Installation and Cable Pinouts 
    2-3 Set Neon Voltage — Ring Ping 
    2
    Set Neon Voltage — Ring Ping
    NOTE:
    If the ring ing  op tion is set to 50 Hz, neon voltag e is not availab le. If 25 Hz is selec ted , 
    the maximum voltag e is 120 volts. Refer to ‘‘Set Ringing Option’’ on page 1-53
    .
    NOTE:
    Set the c ontrol to OFF if there are no neon messag e waiting  lamp s or if LED messag e 
    lamps are used. See Figure 2-1
    .
    Figure 2-1. Setting the Neon Voltage
    1. Call a telep hone with a neon messag e ind ic ator and  leave a messag e.
    2.Chec k for “ ring  p ing ”  (sing le ring  p ulse) eac h time the lamp  flashes 
    (ap p roximately every 3 sec ond s).
    3. Ad just the c ontrol c loc kwise in small inc rements until the ring  p ing  stop s. 
    Be sure that the messag e lamp  still lig hts when the ad justment is finished .
    didmt1 KLC 053097 
    						
    							DEFINITY ECS Release 8.2 Installation, Upgrades, 
    and Additions for Compact Modular Cabinets  555-233-118  Issue 1
    April 2000
    Completing Installation and Cable Pinouts 
    2-4 Installation Completion 
    2
    Installation Completion
    1. Type logoff
     and  p ress En te r  to p revent unauthorized  c hang es to d ata. 
    2. Set the left and  rig ht d oors onto the hing e pins and  c lose the d oors. The 
    d oors must be c losed  to p revent EMI emissions. Tig hten the d oor sc rews. 
    3. Set the rig ht c over p anel onto the rig ht p anel and  sec ure. Do not use 
    forc e.
    Power Supply LED Indications
    It is not p ossib le to view the alarm log  to d etermine whic h p ower unit in a 
    multi-c ab inet system is defec tive. Use the LEDs on the front of eac h p ower unit to 
    d etermine its state. 
    Table 2-1
     shows the LED and  alarm c ond itions. Ring  voltag e and  neon b us 
    output d o not ac tivate alarm status. 
    Table 2-1. LED and Alarm Conditions
    Condition LED Status Alarm State Fan Alarm
    Normal Red  off 
    Ye l lo w  o nop en hig h
    No Inp ut Power Red  off 
    Ye l lo w  o f fc losed op en
    Any DC Outp ut 
    not PresentRed  on  
    Ye l lo w  o f fc losed no state
    Fan Alarm Red  on 
    Ye l lo w  o f fc losed low 
    						