Lucent Technologies DEFINITY Enterprise Communication Server Release 8.2 Installation, Upgrades, And Additions For Compact Modular Cabinets Manual
Lucent Technologies DEFINITY Enterprise Communication Server Release 8.2 Installation, Upgrades, And Additions For Compact Modular Cabinets Manual
Have a look at the manual Lucent Technologies DEFINITY Enterprise Communication Server Release 8.2 Installation, Upgrades, And Additions For Compact Modular Cabinets Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 413 Lucent Technologies manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.
DEFINITY ECS Release 8.2 Installation, Upgrades, and Additions for Compact Modular Cabinets 555-233-118 Issue 1 April 2000 Installing and Cabling the Cabinets 1-105 Install Emergency Transfer Unit and Associated Telephones 1 Install Telephone for Power Transfer Unit Trunk/Auxiliary Field: Telephone Used Only for Emergency Transfer 1. Connec t a p air of wires b etween the -48V and GRD terminals on the yellow emergenc y transfer row/c onnec ting bloc k and the EM TRANS RELAY PWR terminal. See Figure 1-47 . 2. Connec t CO trunk lead s from the p urp le field to the TC terminals on the yellow emerg enc y transfer row/c onnec ting b loc k for eac h trunk. 3. Connec t CO trunk lead s from the g reen field to the TK terminals on the yellow emerg enc y transfer row/c onnec ting b loc k for eac h trunk. 4. Connec t the ST lead s on the yellow emerg enc y transfer row/c onnec ting b loc k for eac h emerg enc y transfer telep hone to the ST terminal ap p earanc e in the yellow trunk/auxiliary field . The ST terminal lead s should b e terminated on the following p airs: 1, 4, 7, 10, 13, 16, 19, or 22 (the first pair of any 3-pair group). 5. Connec t the ST lead s from the terminal in Step 4 to the assig ned terminal in the b lue or white station d istribution field. Trunk/Auxiliary Field: Telephone Used for Emergency Transfer and as Normal Extension 1. Connec t a p air of wires b etween the -48V and GRD terminals on the yellow emergenc y transfer row/c onnec ting b loc k to the EM TRANS RELAY PWR terminal. See Figure 1-48 . 2. Connec t CO trunk lead s from the p urp le field to the TC terminals on the yellow emerg enc y transfer row/c onnec ting b loc k for eac h trunk. 3. Connec t CO trunk lead s from the g reen field to the TK terminals on the yellow emerg enc y transfer row/c onnec ting b loc k for eac h trunk. 4. Connec t telep hone lead s from the p urp le analog line board row/ c onnec ting b loc k to the LC terminals on the yellow emerg enc y transfer row/c onnec ting b loc k for eac h telep hone. 5. Connec t ST lead s on the yellow emerg enc y transfer row/c onnec ting b loc k for eac h emerg enc y transfer telep hone to the ST terminal ap p earanc e in the p urp le trunk/auxiliary field . 6. Connec t the ST lead s from the terminal in Step 5 to the assig ned terminal in the b lue or white station d istribution field. Telephone Installation 1. Connec t the telep hone to the information outlet. 2. Install p atc h c ord s/jump er wires b etween the system sid e and the station sid e of the station d istrib ution field on the MDF.
DEFINITY ECS Release 8.2 Installation, Upgrades, and Additions for Compact Modular Cabinets 555-233-118 Issue 1 April 2000 Installing and Cabling the Cabinets 1-106 Connect Modem to Telephone Network 1 Connect Modem to Telephone Network 1. Cross-c onnec t the network jac k on the mod em to the network interfac e (via a 103A or mod ular wall jac k). See Table 1-22 for the p inout. Figure 1-49. Network Jack on U.S. Robotics Modem Table 1-22. Pinout of Network Jack Pin Number Signal 1 Unused 2Tip 3Ring 4 Unused Figure Notes 1. Pin 1 of network jac k 2. Mod em modmcabl KLC 110397 OFF ON AA CD RD SD C S AR Q/ FAXTR Sportster33.6 Faxmodem 1 2
DEFINITY ECS Release 8.2 Installation, Upgrades, and Additions for Compact Modular Cabinets 555-233-118 Issue 1 April 2000 Installing and Cabling the Cabinets 1-107 Connect Modem to Telephone Network 1 External Modem Option Settings The U.S. Rob otic s Sp ortster Mod el USR 33.6 EXT external mod em is the rec ommend ed external mod em for Release 8 CMC. A loc ally ob tained , type-ap p roved external mod em may b e used . Contac t your Luc ent Tec hnolog ies representative for information. 1. If a non-U.S Robotic s Mod el 839 mod em is installed , refer to the setup instruc tions p rovid ed with that mod em. Refer to Table 1-24 while setting up the mod em. Go to Step 4 to c omp lete the mod em ad ministration. 2. If no mod em is installed , skip to step 5. If a U.S Rob otic s Mod el 839 modem is installed, perform the following. 3. Use Table 1-23 to set the 8 op tion switc hes on the U.S. Rob otic s mod em. 4. At the management terminal, type change system-parameters maintenance and press En t e r. Sc roll to p ag e 3 of the form. 5. Set the Modem Connection: field to external if a mod em is installed . Set the field to none if no mod em is installed . This field must b e ad ministered or alarms will b e g enerated. NOTE: Th e Modem Connection: field c annot b e set to none if Alarm Orig ination is ac tivated. 6. Set the Data Bits: field to 8 (d efault). 7. Set the Parity: field to none (d efault). Table 1-23. U.S. Robotics Model 839 External Modem Switch Settings Switch Setting Function 1 OFF (Up ) DTR (Data Terminal Read y) override 2 OFF (Up ) Verb al result c od es (text-formatted feed b ack charac ters such as c onnec ted or no c arrier) 3 ON (Down) Enab le result cod es 4 OFF (Up ) Disp lays keyb oard command s (loc al echo) 5 OFF (Up ) Sets auto answer. Verify that the Auto Answer Ring Count (rings): on the maintenance-related system parameters form is S0= 10. 6 OFF (Up ) CD (Carrier Detect) overrid e (mod em sends CD signal on c onnec t, drop s CD on d isconnec t) 7 OFF (Up ) Power-on and ATZ reset software defaults (load s Y or Y1 c onfig uration from NVRAM) 8 ON (Down) AT (Attention) command set recog nition (enables rec ognition, smart mod e)
DEFINITY ECS Release 8.2 Installation, Upgrades, and Additions for Compact Modular Cabinets 555-233-118 Issue 1 April 2000 Installing and Cabling the Cabinets 1-108 Connect Modem to Telephone Network 1 8. For non-United States installations, set the remaining mod em field s as shown in Table 1-24 . 9. Press En t e r when the mod em field s are p rop erly ad ministered . Table 1-24. Release 8 CMC Modem Fields Field Description Modem ConnectionDefault is none for Release 8 CMC. Set to external if a mod em is used . Modem Name This field is 20 c harac ters long and p ermits alp hanumeric c harac ters to p rovid e a uniq ue q ualifier for a given mod em. RTS/CTS EnabledInforms mod em that c ommunic ation with the d ata sourc e UART is d riven with RTS/CTS flow c ontrol. The d efault 6-c harac ter field name is &H1 . Set the field name to \Q3 for Intel mod ems. This field is not c ase-sensitive. Asynchronous Data ModeConfig ures mod em as an async hronous d evic e. This 8-c harac ter field name has a d efault value of &M0 (d efault) for Release 8 CMC. Set the field to &M0&Q0 for Intel modems. This field is not c ase-sensitive. DTE Auto-Data SpeedAd justs the sp eed of the d ata sourc e (DTE) UART to the outg oing (mod em-to-mod em) d ata rate. At maximum, this sp eed is 9600 b aud . It is not d esirab le to have the serial d ata fill the mod em buffer faster than the outg oing data rate, sinc e d ata c omp ression is d isab led . The field name has a 6-c harac ter b lank d efault value. The Parad yne produc ts use S90= 1 to enab le this func tionality while the Intel p rod uc t uses \J1 to enab le similar func tionality. This field is not c ase-sensitive. Disable Data CompressionTurns off the d efault d ata c ompression alg orithms used b y most mod ems. The field has a b lank field of 6 c harac ters as d efault. The AT c ommand s that c ontrol this are supp orted b y similar c ommand s; however, these c ommand s d o not op erate in the same manner. The Intel modems require H0%C0 to disable V.42bis & MNP Class 5 data c omp ression alg orithms. The Parad yne p rod uc ts only use %C0 to d isab le b oth algorithms. This field is not c ase-sensitive. Enable Error ControlTurns on the V.42 LAPM and MNP error c ontrol p rotoc ols. The field has a b lank d efault of 6 c harac ters. The Parad yne p rod uc ts use the c ommand \N5 to enab le V.42/MNP/Buffer error c ontrol while the Intel p roduc t uses \N3 to p rovid e similar func tionality. Misc. Init. ParamThis field has a 20-c harac ter b lank d efault and sup ports any initialization p arameters not alread y sp ec ified . The AT c ommand s sp ec ified in this field are always the last initialization p arameters to b e sent to the external mod em. This field is not c ase-sensitive. Continued on next page
DEFINITY ECS Release 8.2 Installation, Upgrades, and Additions for Compact Modular Cabinets 555-233-118 Issue 1 April 2000 Installing and Cabling the Cabinets 1-109 Connect Modem to Telephone Network 1 Auto-Answer Ring NumberThis field c ontrols the number of ring s required b efore the mod em answers an inc oming c all. This field should b e set to S0= 10. Dial Type This field c ontrols the typ e of interreg ister sig naling used b etween the mod em and the CO. This 3-c harac ter field is d enoted b y “ T” for tone dialing (default) and “P” for pulse dialing. This setting depends on type of line (tone or p ulse) to the mod em. Adjustable Make/Break RatioThis field c ontrols the make/b reak ratios of p ulses and DTMF d ialing . Most mod ems have sup p ort for d ifferent make/ b reak op tions for p ulse d ialing only. Parad yne, Intel, and U.S. Rob otic s use the d efault &P0 to selec t a ratio of 39% make and 61% break for c ommunic ation for the United States and Canad a. The op tion &P1 sets a ratio of 33% make and 67% break for the United Kingdom and Hong Kong. This is a 5-c harac ter b lank field (d efault) and is not c ase-sensitive. Dial Command This field has a d efault of “ D” in a 3-c harac ter field . This field d enotes the stand ard d ialing c ommand of the mod em and is not c ase-sensitive. No Answer Time-OutMost mod ems provide a timer that ab andons any outb ound d ata c all after a p red etermined interval. This is a non-ad ministrab le parameter. Table 1-24. Release 8 CMC Modem Fields — Continued Field Description Continued on next page
DEFINITY ECS Release 8.2 Installation, Upgrades, and Additions for Compact Modular Cabinets 555-233-118 Issue 1 April 2000 Installing and Cabling the Cabinets 1-110 Connect Modem to Telephone Network 1
Completing Installation and Cable Pinouts 2-1 Perform System Administration 2 DEFINITY ECS Release 8.2 Installation, Upgrades, and Additions for Compact Modular Cabinets 555-233-118 Issue 1 April 2000 2 Completing Installation and Cable Pinouts Perform System Administration NOTE: Some of the interfac e units used b etween the system and other typ es of eq uip ment req uire sp ec ific c onfiguration setting s and ad ministration for eac h ap p lic ation. Refer to the user’s g uide for eac h eq uip ment typ e for information on how to loc ate and set the c onfig uration and op tion switc hes. 1. Ad minister the system b y ad d ing the c ustomer d ata to matc h the wiring , telep hones, and other eq uip ment. See DEFINITY Enterp rise Communic ations Server Release 8 Ad ministrator’s Guid e. 2. Return to this sec tion when finished . NOTE: Refer to DEFINITY Enterp rise Communic ations Server Release 8 Installation for Ad junc ts and Perip herals, for data module and other peripheral installation and c onfig uration req uirements. Resolve Alarms 1. Examine the alarm log . Resolve any alarms using DEFINITY Enterp rise Communic ations Server Release 8 Maintenanc e for R8c si. 2. Refer to ‘‘Power Supply LED Indications’’ on page 2-4 if power supply faults are susp ec ted.
DEFINITY ECS Release 8.2 Installation, Upgrades, and Additions for Compact Modular Cabinets 555-233-118 Issue 1 April 2000 Completing Installation and Cable Pinouts 2-2 Perform System Administration 2 Enable Alarm Origination to INADS No External Modem Installed (or No Alarm Origination to INADS) 1. Type change system-parameters maintenance and press En t e r. 2. Type n in the Alarm Orig ination Ac tivated to OSS Numb ers field and p ress En t e r . 3. For some software releases, enab le Cleared Alarm Notific ation and Restart Notific ation before the sub mitting the form. External Modem Installed 1. Type change system-parameters maintenance and press En t e r. 2. Type y in the Alarm Orig ination Ac tivated to OSS Numb ers field and p ress En t e r . 3. For some software releases, enab le Cleared Alarm Notific ation and Restart Notific ation before the sub mitting the form. 4. Be sure the system is p art of the INADS d atabase b y c alling the INADS Datab ase Administrator at the Tec hnic al Servic e Center (TSC). Verify that INADS c an d ial into the system and that the system c an d ial out to INADS. As p art of the system reg istration proc ess, the INADS Datab ase Ad ministrator enab les Alarm Orig ination and c ustomer op tions. NOTE: When c alling from a remote mod em, you may need to d isab le error c orrec tion to allow the mod ems to c onnec t suc c essfully. For examp le, the AT&T Parad yne Keep InTouc h ® mod em may req uire the “ AT\n0” c ommand . 5. Log off and log b ac k in. Place a Test Call 1. From any telep hone c onnec ted to a dig ital line c irc uit p ac k, c all any nearb y telep hone c onnec ted to an analog line c irc uit p ac k. 2. Verify that the dial tone, ring ing pattern, and talk p ath are ac c ep tab le. 3. Plac e a c all throug h the Central Offic e (outsid e c all) to any nearb y telep hone. Verify that the d ial tone, ringing p attern, and talk p ath are ac c ep tab le.
DEFINITY ECS Release 8.2 Installation, Upgrades, and Additions for Compact Modular Cabinets 555-233-118 Issue 1 April 2000 Completing Installation and Cable Pinouts 2-3 Set Neon Voltage — Ring Ping 2 Set Neon Voltage — Ring Ping NOTE: If the ring ing op tion is set to 50 Hz, neon voltag e is not availab le. If 25 Hz is selec ted , the maximum voltag e is 120 volts. Refer to ‘‘Set Ringing Option’’ on page 1-53 . NOTE: Set the c ontrol to OFF if there are no neon messag e waiting lamp s or if LED messag e lamps are used. See Figure 2-1 . Figure 2-1. Setting the Neon Voltage 1. Call a telep hone with a neon messag e ind ic ator and leave a messag e. 2.Chec k for “ ring p ing ” (sing le ring p ulse) eac h time the lamp flashes (ap p roximately every 3 sec ond s). 3. Ad just the c ontrol c loc kwise in small inc rements until the ring p ing stop s. Be sure that the messag e lamp still lig hts when the ad justment is finished . didmt1 KLC 053097
DEFINITY ECS Release 8.2 Installation, Upgrades, and Additions for Compact Modular Cabinets 555-233-118 Issue 1 April 2000 Completing Installation and Cable Pinouts 2-4 Installation Completion 2 Installation Completion 1. Type logoff and p ress En te r to p revent unauthorized c hang es to d ata. 2. Set the left and rig ht d oors onto the hing e pins and c lose the d oors. The d oors must be c losed to p revent EMI emissions. Tig hten the d oor sc rews. 3. Set the rig ht c over p anel onto the rig ht p anel and sec ure. Do not use forc e. Power Supply LED Indications It is not p ossib le to view the alarm log to d etermine whic h p ower unit in a multi-c ab inet system is defec tive. Use the LEDs on the front of eac h p ower unit to d etermine its state. Table 2-1 shows the LED and alarm c ond itions. Ring voltag e and neon b us output d o not ac tivate alarm status. Table 2-1. LED and Alarm Conditions Condition LED Status Alarm State Fan Alarm Normal Red off Ye l lo w o nop en hig h No Inp ut Power Red off Ye l lo w o f fc losed op en Any DC Outp ut not PresentRed on Ye l lo w o f fc losed no state Fan Alarm Red on Ye l lo w o f fc losed low