    Have a look at the manual Lucent Technologies DEFINITY Enterprise Communication Server Release 8.2 Installation, Upgrades, And Additions For Compact Modular Cabinets Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 413 Lucent Technologies manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.

    							DEFINITY ECS Release 8.2 Installation, Upgrades, 
    and Additions for Compact Modular Cabinets  555-233-118  Issue 1
    April 2000
    About This Book 
    xxi Standards Compliance 
    Standards Compliance
    The eq uip ment p resented  in this doc ument c omp lies with the following  stand ard s 
    (as ap p rop riate):
    nITU-T (Formerly CCITT)
    nEC M A
    nETSI
    nIPNS
    nDPNSS
    nNational ISDN-1
    nNational ISDN-2
    nISO-9000
    nANSI
    nFCC Part 15 and Part 68
    nEN55022
    nEN50081
    nEN50082
    nC I SPR2 2
    nAustralia AS3548 (AS/NZ3548)
    nAustralia AS3260
    nIEC 825
    nIEC 950
    nUL 1459
    nUL 1950
    nCSA C222 Number 225
    nTS0 0 1
    Contac t your Luc ent Tec hnolog ies rep resentative for more information. 
    						
    							DEFINITY ECS Release 8.2 Installation, Upgrades, 
    and Additions for Compact Modular Cabinets  555-233-118  Issue 1
    April 2000
    About This Book 
    xxii Electromagnetic Compatibility Standards 
    Electromagnetic Compatibility 
    Standards
    This p rod uc t c omp lies with and  c onforms to the following  stand ard s (as 
    ap p rop riate):
    nLimits and  Methods of Measurements of Rad io Interferenc e 
    Charac teristic s of Information Tec hnolog y Eq uipment, EN55022 
    (CISPR22), 1993
    nEN50082-1, Europ ean Generic  Immunity Standard
    nFCC Part 15
    nAustralia AS3548
    NOTE:
    The system c onforms to Class A (ind ustrial) eq uip ment. Voic e 
    terminals meet Class B requirements.
    nElec trostatic  Disc harg e (ESD) IEC 1000-4-2
    nRad iated  rad io freq uenc y field  IEC 1000-4-3
    nElec tric al Fast Transient IEC 1000-4-4
    nLightning  effec ts IEC 1000-4-5
    nConduc ted radio freq uenc y IEC 1000-4-6
    nMains freq uenc y mag netic  field  IEC 1000-4-8
    nLow freq uenc y mains d isturb anc e IEC 1000-4-11 
    						
    							DEFINITY ECS Release 8.2 Installation, Upgrades, 
    and Additions for Compact Modular Cabinets  555-233-118  Issue 1
    April 2000
    About This Book 
    xxiii Antistatic Protection 
    European Union Standards
    Luc ent Tec hnolog ies Business Communic ations Systems (BCS) d ec lares that the 
    DEFINITY eq uip ment sp ec ified  in this d oc ument b earing  the “ CE”  mark c onforms 
    to the Europ ean Union Elec tromag netic  Compatib ility Direc tives. 
    The “ CE”  (Conformité Europ eénne) mark ind ic ates c onformanc e to the Europ ean 
    Union Elec tromag netic  Comp atib ility Direc tive (89/336/EEC), Low Voltag e 
    Direc tive (73/23/EEC), Telec ommunic ation Terminal Equip ment (TTE) Direc tive 
    (91/263/EEC), i-CTR3 Basic  Rate Interfac e (BRI), and  i-CTR4 Primary Rate 
    Interfac e (PRI) as ap p lic ab le.
    The “ CE”  mark is ap plied  to the following  Release 8 p rod uc ts:
    nGlob al AC-p owered  Multi-Carrier Cabinet (MCC) 
    nDC-p owered  Multi-Carrier Cab inet (MCC) with 25 Hz ring  g enerator
    nAC-p owered  Enhanc ed  Sing le-Carrier Cab inet (ESCC) with 25 Hz ring  
    g enerator
    nAC-p owered  Comp ac t Sing le-Carrier Cab inet (CSCC) with 25 Hz ring  
    g enerator
    nEnhanc ed DC p ower system 
    nAC-p owered  Comp ac t Mod ular Cab inet (CMC) with 25 Hz ring  g enerator
    nAC-p owered  Comp ac t Mod ular Cab inet (CMC) with 50 Hz ring  g enerator 
    for Franc e
    Antistatic Protection
    !CAUTION:
    When hand ling  c irc uit pac ks or any c omp onents of a DEFINITY System, 
    always wear an antistatic  wrist g round  strap . Connec t the strap  to an 
    ap p roved  g round  suc h as an unp ainted  metal surfac e on the DEFINITY 
    Sys t e m .
    Remove/Install Circuit Packs
    !CAUTION:
    The c ontrol c irc uit p ac ks with white lab els c annot b e removed  or installed  
    when the power is on. The port circuit packs with gray labels (older version 
    circuit packs had purple labels) can be removed or installed when the 
    p ower is on. 
    						
    							DEFINITY ECS Release 8.2 Installation, Upgrades, 
    and Additions for Compact Modular Cabinets  555-233-118  Issue 1
    April 2000
    About This Book 
    xxiv Federal Communications Commission Statement 
    Federal Communications Commission 
    Statement
    Part 68: Statement
    Part 68: Answer-Sup ervision Sig naling . Allowing  this eq uip ment to b e op erated in 
    a manner that d oes not p rovid e p rop er answer-sup ervision sig naling is in 
    violation of Part 68 rules. This equip ment returns answer-sup ervision sig nals to 
    the p ub lic  switc hed network when:
    nAnswered  b y the c alled  station
    nAnswered  b y the attend ant
    nRouted  to a rec ord ed  announc ement that c an b e ad ministered  b y the CPE 
    user
    This eq uip ment returns answer-sup ervision sig nals on all DID c alls forward ed 
    b ac k to the p ub lic  switc hed telep hone network. Permissib le exc eptions are: 
    nA c all is unanswered
    nA b usy tone is rec eived
    nA reorder tone is rec eived
    Luc ent Tec hnolog ies attests that this reg istered  eq uipment is c ap ab le of 
    p rovid ing  users ac c ess to interstate p rovid ers of op erator servic es throug h the 
    use of ac c ess c od es. Modific ation of this eq uip ment b y c all ag g reg ators to b loc k 
    ac c ess d ialing  c od es is a violation of the Telep hone Op erator Consumers Ac t of 
    1990.
    This eq uip ment c omp lies with Part 68 of the FCC Rules. A lab el is p rovid ed  on 
    this eq uipment that c ontains, among  other information, the FCC reg istration 
    numb er and  ring er eq uivalenc e numb er (REN) for this eq uip ment. If req uested , 
    this information must b e p rovid ed  to the telep hone c omp any. 
    The REN is used  to d etermine the q uantity of d evic es whic h may b e c onnec ted  
    to the telep hone line. Exc essive RENs on the telep hone line may result in d evic es 
    not ring ing  in resp onse to an inc oming  c all. In most, b ut not all areas, the sum of 
    RENs should  not exc eed  5.0. To be c ertain of the numb er of d evic es that may b e 
    c onnec ted  to a line, as d etermined  b y the total RENs, c ontac t the loc al telep hone 
    c omp any.
    NOTE:
    REN is not req uired  for some typ es of analog  or d ig ital fac ilities. 
    						
    							DEFINITY ECS Release 8.2 Installation, Upgrades, 
    and Additions for Compact Modular Cabinets  555-233-118  Issue 1
    April 2000
    About This Book 
    xxv Federal Communications Commission Statement 
    Means of Connection
    Connec tion of this equip ment to the telep hone network is shown in the following  
    tab le.
    If the terminal eq uip ment (DEFINITY
    ® System) c auses harm to the telep hone 
    network, the telep hone c omp any will notify you in ad vanc e that temp orary 
    d isc ontinuanc e of servic e may b e req uired . But if ad vanc e notic e is not prac tic al, 
    the telep hone c omp any will notify the c ustomer as soon as p ossib le. Also, you 
    will be ad vised  of your rig ht to file a c omp laint with the FCC if you b elieve it is 
    nec essary.
    The telep hone c omp any may make c hang es in its fac ilities, eq uip ment, 
    op erations or proc ed ures that c ould  affec t the op eration of the equip ment. If this 
    happens, the telephone c ompany will provide advance notice in order for you to 
    make nec essary mod ific ations to maintain uninterrup ted  servic e.
    If troub le is exp erienc ed  with this eq uip ment, for rep air or warranty information, 
    p lease c ontac t the Tec hnic al Servic e Center at 1-800-242-2121. For assistanc e 
    outsid e of the United  States, refer to ‘‘Where to Call for Tec hnic al Sup p ort’’
    . If the 
    eq uip ment is c ausing  harm to the telep hone network, the telep hone c ompany 
    may req uest that you d isc onnec t the eq uip ment until the p rob lem is resolved .
    It is rec ommend ed  that rep airs b e performed  b y Luc ent Tec hnolog ies c ertified  
    tec hnic ians.
    The eq uip ment c annot b e used on p ublic  c oin p hone servic e p rovid ed  b y the 
    telep hone c omp any. Connec tion to p arty line servic e is sub jec t to state tariffs. 
    Contac t the state p ub lic  utility c ommission, p ub lic  servic e c ommission or 
    corporation commission for information.
    This eq uip ment, if it uses a telep hone rec eiver, is hearing  aid  c omp atib le.
    Manufacturer ’s Port Identifier FIC CodeSOC/REN/
    A.S. Code Network Jacks
    Off/On Premises Station OL13C 9.0F RJ2GX, RJ21X, 
    RJ11C
    DID Trunk 02RV2-T 0.0B RJ2GX, RJ21X
    CO Trunk 02GS2 0.3A RJ21X
    CO Trunk 02LS2 0.3A RJ21X
    Tie Trunk TL31M 9.0F RJ2GX
    1.544 Dig ital Interfac e 04DU9-B,C 6.0P RJ48C, RJ48M
    1.544 Dig ital Interfac e 04DU9-BN,KN 6.0P RJ48C, RJ48M
    120A2 Channel Servic e Unit 04DU9-DN 6.0P RJ48C 
    						
    							DEFINITY ECS Release 8.2 Installation, Upgrades, 
    and Additions for Compact Modular Cabinets  555-233-118  Issue 1
    April 2000
    About This Book 
    xxvi Federal Communications Commission Statement  
    						
    							Installing and Cabling the Cabinets 
    1-1 Check Customer’s Order 
    1
    DEFINITY ECS Release 8.2 Installation, Upgrades, 
    and Additions for Compact Modular Cabinets  555-233-118  Issue 1
    April 2000
    1
    Installing and Cabling the Cabinets
    Check Customer’s Order
    Chec k the c ustomer’s order and  the ship ping  p ac king  lists to c onfirm that all 
    eq uip ment is p resent. If any eq uip ment is missing , report this to your Luc ent 
    Tec hnolog ies rep resentative. Chec k the system ad junc ts for d amag e and  rep ort 
    all damage according to local shipping instructions. 
    Correcting Shipping Errors
    1. Red-tag all defective equipment and over-shipped equipment and return 
    ac c ord ing  to the nearest Material Stoc king  Loc ation (MSL) instruc tions. 
    For international c ustomers, c ontac t your ord er servic e ag ent.
    2. Direc t all short-ship p ed  reports to the nearest MSL. Contac t the 
    ap p rop riate loc ation for sp ec ific  instruc tions. For Streamlined  
    Imp lementation in the United  States, c all 1-800-772-5409.
    Unpack and Inspect
    READ THIS FIRST !
    !CAUTION:
    A fully load ed  system weig hs 58 lb s (26.3 kg ). Use lifting  p rec autions. If the 
    d oors, p ower unit, and  c irc uit p ac ks are removed , the unit weig hs only 29 
    lb s (13.1 kg). 
    1. Verify the equipment received. See Figure 1-1
    . Ac tual eq uip ment may vary 
    in ap p earanc e and  may ship  in sep arate p ac kag es.  
    						
    							DEFINITY ECS Release 8.2 Installation, Upgrades, 
    and Additions for Compact Modular Cabinets  555-233-118  Issue 1
    April 2000
    Installing and Cabling the Cabinets 
    1-2 Unpack and Inspect 
    1
    2. Eq uip ment c omc od es are listed  in Table 1-1.
    3. Before mounting  the c ab inets, remove the c ab inet d oors b y op ening  them 
    and  lifting them straig ht up  and  off of the hing e p ins. 
    Figure 1-1. Equipment Packed with the Compact Modular Cabinet Figure Notes
    1. Left p anel (also ac ts as a wall-mount template 
    and  as a floor mount p ed estal)
    2. Comp act mod ular c abinet
    3. Right p anel
    4. U.S. Robotics external modem (not shipped 
    with all systems)
    5. #12 x 1-inc h should er screws
    6. Proc essor interfac e cab le (not shipp ed  with all 
    cabinets)7. AC p ower c ord  (NEMA 5-15P or 
    IEC 320)
    8. Vertic al TDM/LAN b us c ab le (not 
    ship ped  with all systems)
    9. Horizontal TDM/LAN bus c able 
    (not ship ped  with all systems)
    10. 14-in. (35.5 cm) 6 AWG (#40) 
    (16 mm
    2) ground wire
    11. Sing le-p oint ground  b loc k
    qrdmpart KLC 011598
    6
    7
    4
    8
    9
    1011
    5
    3
    2
    1 
    						
    							DEFINITY ECS Release 8.2 Installation, Upgrades, 
    and Additions for Compact Modular Cabinets  555-233-118  Issue 1
    April 2000
    Installing and Cabling the Cabinets 
    1-3 Comcodes for CMC 
    1
    Comcodes for CMC
    Table 1-1 lists the c omc od es for equip ment used  with the CMC.
    Table 1-1. Comcodes for Release 7.1 and Later
    Comcode Description
    847951662 Left Panel
    847951670 Rig ht Panel 
    847915238 Rig ht Door
    847915246 Left Door
    847960002 Proc essor Interfac e Cab le
    108186255 TN798B Proc essor Circ uit Pac k
    107784019 TN2182B Tone-Cloc k — 
    Tone Detector and Call Classifier Circuit Pac k
    407633999 U.S. Rob otic s Sp ortster Mod el USR 33.6 EXT External Mod em
    105631527 TDM/LAN Bus Terminator (AHF110)
    407772870 Vertic al TDM/LAN Bus Cable (WP-91716 List 8)
    407772888 Horizontal TDM/LAN Bus Cab le (WP-91716 List 9)
    706827717 Sing le-Point Ground  Bloc k
    H600-487 14-inc h (35.5 c m) 6 AWG (#40) (16 mm
    2) Green Ground  Wire
    847987187 CMC 110 Cross-Connec t Assemb ly (Main Distrib ution Frame)
    407676691 120 VAC Power Distrib ution Unit (145D 6-AC)
    107949364 650A Power Sup p ly
    848082715 Fan Assemb ly
    407745009 Fan Air Filter
    405362641 120 VAC Power Cord  (U.S.)
    407786623 120 VAC Power Cord  (Europ e)
    407786599 120 VAC Power Cord  (United  Kingd om)
    407786631 120 VAC Power Cord  (Australia)
    407790591 120 VAC Power Cord  (Ind ia)
    106278062 Ap p aratus Blank (Circ uit Pac k Blank) (158P)
    601817448 2-Mb yte Mass-Storag e Translation Card  (White Card )
    Continued on next page 
    						
    							DEFINITY ECS Release 8.2 Installation, Upgrades, 
    and Additions for Compact Modular Cabinets  555-233-118  Issue 1
    April 2000
    Installing and Cabling the Cabinets 
    1-4 Comcodes for CMC 
    1
    601817422 4-Mb yte Mass-Storag e Translation Card  (White Card )
    601817430 10-Mb yte Mass-Storag e Translation Card (White Card )
    106606536 Integ rated  Channel Servic e Unit (ICSU) (120A2)
    107988867 DS1 Loop b ac k Jac k (T1 Only) (700A)
    107152969  75 Ohm DS1 Coaxial Ad ap ter (888B)
    403613003  157B Connec ting  Bloc k
    406948976 6SCP-110 Protec tor
    107435091  507B Sneak Current Fuse Panel
    407216316  220029 Sneak Current Fuse
    403613003  157B Connec ting  Bloc k
    103970000 Main Distrib ution Frame Lab el (Cod e 220A)
    104307327 C6C c ab le — 50-ft (15.2 m) shield ed DS1 c ab le with 50-p in male to 
    15-pin male
    104307376 C6D c ab le — 50-ft (15.2 m) shield ed DS1 c ab le with 50-p in male on 
    eac h end
    104307434 C6E c able — 100-ft (30.5 m) shield ed  DS1 c ab le with 50-p in male to 
    50-p in female
    104307475 C6F c ab le — 50-ft (15.2 m) shield ed DS1 c ab le with 50-p in male to 3 in. 
    (7.6 cm) stub
    102381779  3B1A Carbon Bloc k
    104410147  3B1E-W Wid e Gap  Gas Tub e
    105514756  3C1S Solid State
    102904893  4B1C Carb on Bloc k with Heat Coil
    104401856  4B1E-W Wid e Gap  Gas Tub e with Heat Coil
    104386545  4C1S Solid  State with Heat Coil
    406948976  SCP-110 Sneak Current Protec tor
    407216316  220029 Fuse Sneak Current Protec tor
    105581086  4C3S-75 Solid  State with Heat Coil
    406144907 ITW LINX Gas Tub e, Avalanc he Sup press
    901007120 ITW Linx Ground  Bar (used  with ab ove)
    Table 1-1. Comcodes for Release 7.1 and Later — Continued
    Comcode Description
    Continued on next page 
    						
    All Lucent Technologies manuals Comments (0)

    Related Manuals for Lucent Technologies DEFINITY Enterprise Communication Server Release 8.2 Installation, Upgrades, And Additions For Compact Modular Cabinets Manual