Lucent Technologies DEFINITY Enterprise Communication Server Release 8.2 Installation, Upgrades, And Additions For Compact Modular Cabinets Manual
Lucent Technologies DEFINITY Enterprise Communication Server Release 8.2 Installation, Upgrades, And Additions For Compact Modular Cabinets Manual
Have a look at the manual Lucent Technologies DEFINITY Enterprise Communication Server Release 8.2 Installation, Upgrades, And Additions For Compact Modular Cabinets Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 413 Lucent Technologies manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.
DEFINITY ECS Release 8.2 Installation, Upgrades, and Additions for Compact Modular Cabinets 555-233-118 Issue 1 April 2000 Adding or Removing Hardware 4-49 Add IP Interface Assembly 4 NOTE: In the Finish d ialog b ox, selec t I will restart later . Do not select Restart computer . This would b e a g ood time to read the Read me.txt file. 5. Click on Start > Settings > Control Panel > Services . 6. Select IP Trunk and click on Startup . NOTE: Do not c lic k on Start. 7. Under Startup Type, select Disabled and c lic k OK to d isab le IP Trunk mod e. NOTE: If IP trunk and Med Pro servic es are b oth set to automatic , the TN802B d efaults to IP Trunk and MedPro features c annot be used . 8. Select MedPro and c lic k on Startup . NOTE: Do not c lic k on Start. 9. Under Startup Type, select Automatic and c lic k OK to enab le Med Pro mod e. 10. Clic k Start > Shut Down and selec t Restart the computer? or on the TN802: Press the rec essed reset b utton on the fac ep late (see Figure 4-9 ) until the LCD shows a flashing MSHUT * . When the flashing stops and the asterisk d isap p ears (ab out 2 min), reseat the c irc uit p ac k to restart the system. or on the SAT: a. Type busyout board UUCSS and press En te r . b. Type reset board UUCSS and p ress En te r. c . Typ e release b oard UUCSS and p ress En te r. Onc e the system is c omp letely initialized , the LCD read s MEDPRO * . !WARNING: When c onnec ted remotely via p c ANYWHERE, only use the p c ANYWHERE Restart Host Comp uter b utton on the toolb ar to restart Wind ows NT.
DEFINITY ECS Release 8.2 Installation, Upgrades, and Additions for Compact Modular Cabinets 555-233-118 Issue 1 April 2000 Adding or Removing Hardware 4-50 Add IP Interface Assembly 4 11. Affix the new TN802B lab el to the c irc uit p ac k. 12. Disc onnec t the monitor, keyb oard , and mouse. Circuit Pack Verification 1. Type change circuit-pack and p ress En te r. 2. Chec k the Cod e c olumn to see if it says DSMAPD or Med Pro. . 3. To c orrec t it, g o to the entry just above the TN802B that says DSMAPD. 4. Type MEDPRO, and press En t e r. Changing the one entry automatic ally c hang es the entry ab ove it. If it is in IP Trunk mode, you g et the following error message: MedPro type requires TN802 with application. Type MEDPRO on circuit-packs form. 5. To c omp lete the ad ministration, refer to the DEFINITY ECS Release 8 Network Connec tivity b ook. change circuit-packs Page 1 of 5 CIRCUIT PACKS Cabinet: 1 Carrier: A Carrier Type: processor Slot Code Sf Mode Name Slot Code Sf Mode Name 11: MEDPRO RESERVED-IP 01: TN754 DIGITAL LINE 12: MEDPRO RESERVED-IP 02: TN758 POOLED MODEM 13: TN802 B MAPD BOARD 03: TN2144 ANALOG LINE 14: 04: TN746 B ANALOG LINE 15: 05 16: 06: TN771 C MAINTENANCE/TEST 07: TN464 F DS1 INTERFACE 08: TN2140 E&M TIE TRUNK 09: TN767 E DS1 INTERFACE 10: TN799 B CONTROL-LAN # indicates circuit pack conflict.
DEFINITY ECS Release 8.2 Installation, Upgrades, and Additions for Compact Modular Cabinets 555-233-118 Issue 1 April 2000 Adding or Removing Hardware 4-51 Add TTC Japanese 2-Mbit Trunks 4 Add TTC Japanese 2-Mbit Trunks The TN2242 Jap an 2-Mb it trunk interc onnec ts DEFINITY to other vend or eq uip ment in Jap an as well as to other DEFINITY switc hes through the Time Division Multip lexor (TDM). Installing the trunk 1. Determine the p ort assig nment of the trunk from the Trunk Group form. 2. Install a TN2242 c irc uit p ac k in assigned c arrier slot. 3. Connec t the H600-513 c ab le from the DEFINITY c ab inet to the Time Division Multip lexor d evice. 4. To ad minister forms, see the following sec tions in the DEFINITY Enterp rise Communic ations Server Release 8 Ad ministrator’s Guid e. nFor ISDN ap p lic ations, see ISDN Servic e. nFor non-ISDN applications, see Managing Trunks. Installing an Integrated Channel Service Unit (ICSU) Module The integ rated c hannel servic e unit (ICSU) is a c omb ination of a 120A CSU mod ule integ rated with a DS1 c irc uit p ac k. Use this d evic e with the 700A DS1 loop b ac k jac k when testing the DS1 sp an. Checking for required components The integ rated c hannel servic e unit (ICSU) p ac kag e c ontains: n120A CSU mod ule nCab le H700-383 4-pair modular cord Group 2, 50-ft (15.2-m) c ab le (stand ard ) nCord DW8A-DE 4-p air mod ular c ord to alarm c ontac ts nDS1 c irc uit p ac k EXAMPLE: 3A0701 Cab inet (Port Network)Carrier Slot Numb erPo rt Numb er
DEFINITY ECS Release 8.2 Installation, Upgrades, and Additions for Compact Modular Cabinets 555-233-118 Issue 1 April 2000 Adding or Removing Hardware 4-52 Installing an Integrated Channel Service Unit (ICSU) Module 4 The b asic ICSU req uires a TN474E or TN777D or later suffix. The enhanc ed integ rated c hannel servic e unit req uires a TN474F or TN777E or later suffix. Installing the 120A CSU See Figure 4-11. Figure 4-11. 120A Channel Service Unit Module !CAUTION: Do not p lug the 120A into any c irc uit p ac k other than a TN474F or TN777E or later release/vintag e. Do not c onnec t the 120A to any interfac e other than a network smart jac k. 1. Rear of carrier containing DS1 circuit pack 2. 120A CSU 3. To 25-pair connector on rear of carrier4. DW8A-DE 4-pair cord to alarm contacts (optional) 5. 4-pair cord to network interface (H700-383) 1cydfcsu1 KLC 033099120A CSU MODULE MADE IN U.S.A.ALARMCONT ACTSNETWORK 1 2 3 45
DEFINITY ECS Release 8.2 Installation, Upgrades, and Additions for Compact Modular Cabinets 555-233-118 Issue 1 April 2000 Adding or Removing Hardware 4-53 Installing an Integrated Channel Service Unit (ICSU) Module 4 Be sure the DS1 c irc uit p ac k is set for 24-c hannel op eration (1.544 Mbp s). The 120A d oes not op erate with the 32-c hannel interfac e. A switc h on the c irc uit p ac k or ad ministration sets this op tion. !CAUTION: Always wear an antistatic wrist strap when installing a 120A mod ule. Do not touc h the external alarm c ab le when it is c onnec ted to the 120A. Static d isc harg e c an d amag e c onnec tor terminals and relays. 1. Unp lug the DS1 c irc uit p ac k from its slot. 2. Install a 4C retainer in the 50-p in p lug assoc iated with the DS1 c irc uit p ac k slot. 3.Plug the 120A’s 25-p air c onnec tor d irec tly into the p lug assoc iated with the DS1 c irc uit p ac k slot. 4. Sec ure the 4C retainer around the 120A. 5. Attac h the sup p lied H700-383 c able to the 120A and to the network smart jac k. This c ab le is d irec tional. To determine the end that c onnec ts to the 120A, p erform a c ontinuity test b etween pins 3 and 7. The end with this c ontinuity is the 120A end . The shield is g round ed only at the 120A end . Use the c able p rovid ed . If c ab ling other than that p rovided with the 120A is used , ob serve the following g uid elines: nUse 24-g aug e wire that p rovid es ind ividually shield ed , twisted p airs for transmit and rec eive sig nals. Use the c ab le b etween the network interfac e and the 120A. Ground the shield s of this c able only at the 120A end to avoid g round loop s. nCab ling b etween the network interfac e and 120A c an have no bridge taps. nIf using stand ard house riser c ab le for c onnec tions b etween the network interfac e and the 120A, maintain a 100-p air sep aration b etween the rec eive and transmit twisted p airs. nIf using stand ard house riser c ab le for c onnec tions b etween the network interfac e and the 120A, allow no more than 2 c ross c onnec ts to 110-typ e c ross c onnec t bloc ks. nNever use quad c ab le (untwisted two pair telep hone c ab le) in a DS1 line. nAvoid mixing wires of d ifferent g aug es in a DS1 line. 6. If using external alarm eq uip ment, attac h the sup p lied DW8 c ab le to the 120A and the external eq uip ment. The maximum length of this c ab le d ep end s on the alarm eq uip ment.
DEFINITY ECS Release 8.2 Installation, Upgrades, and Additions for Compact Modular Cabinets 555-233-118 Issue 1 April 2000 Adding or Removing Hardware 4-54 Installing an Integrated Channel Service Unit (ICSU) Module 4 7. If a TN474F is used , make sure the c irc uit p ac k is set for 24-c hannel op eration. Set the switc h on the c irc uit p ac k as shown in Fig ure 2-1. 8. From the DS1 c irc uit-p ac k form of the system ad ministration c onsole, set the line c omp ensation field to 0-133 ft (40.6 m). 9. Reset the 120A b y reseating the DS1 c irc uit p ac k. When you reinsert the DS1 c irc uit p ac k after installing a 120A CSU the 120A resets. The DS1 c irc uit p ac k initializes and tests the 120A. When initialization and testing is c omp lete, the g reen LED goes off. If the RED indic ator is OFF after the test, the ICSU is working . 10. If the c irc uits d o not p ass the self test, troub leshoot the 120A as instruc ted in Integ rated CSU Mod ule Installation and Op eration, 555-230-193. Table 4-8 p rovid es the H700-383 c ab le pinouts. Table 4-9 p rovides the c ab le leng ths for eac h c ab le g roup numb er. Table 4-8. H700-383 Cable Pin Assignments Pin ColorChannel Service Unit DesignationNetwork Designation Function 1BK Line in 0 R1 RCV 2 Y Line in 1 T1 3 Shield 4 R Line out 0 R XMT 5 G Line out 1 T 7 Shield 7 Not assigned 8 Not assigned Table 4-9. H700-383 Cable Lengths by Group Number Group Length Group Length 1 25 feet (7.7 m) 5 125 ft (38.1 m) 2 50 feet (15.2 m) 7 200 ft (71 m) 3 75 feet (22.9 m) 7 400 ft (122 m) 4 100 feet (30.5 m) 8 750 ft (198.1 m)
DEFINITY ECS Release 8.2 Installation, Upgrades, and Additions for Compact Modular Cabinets 555-233-118 Issue 1 April 2000 Adding or Removing Hardware 4-55 Add NAA1 Fiber Optic Circuit Pack 4 Add NAA1 Fiber Optic Circuit Pack Unpack and Inspect 1. Verify the eq uipment rec eived . See Figure 4-12. Ac tual eq uip ment may vary in ap p earanc e and may ship in sep arate p ac kag es. 2. See Table 4-10 for a list of p art c omc od es. Figure 4-12. NAA1 Fiber Optic Interface Kit Equipment Figure Notes 1. NAA1 c irc uit p ac k 2. SC/ST c onnec tors (2x) 3. SC/SC c onnec tors (2x)4. Fiber cables (2 gray multi-mode c ab les for use with the TN2305 c irc uit p ac k and 2 yellow sing le mod e c ables for use with the TN2306 circuit pack) ckdakit LJK 021199 A B A B A B A BA B 1 2 3 4
DEFINITY ECS Release 8.2 Installation, Upgrades, and Additions for Compact Modular Cabinets 555-233-118 Issue 1 April 2000 Adding or Removing Hardware 4-56 Add NAA1 Fiber Optic Circuit Pack 4 Installation Instructions 1. Remove the c over. 2. Insert the ATM c irc uit p ac k, p referab ly in the top row. 3. Insert the c onnec tor into the top op ening at the rear of the NAA1 c irc uit pack. See Figure 4-13 . 4. Attac h either the sing le mod e (yellow) c able or multi-mod e (g ray) c ab le to the c onnec tor. 5. Route the c ab le throug h the slot A in the fac ep late. 6. Determine how muc h of the c ab le is need ed to reac h the ATM c irc uit pack. 7. Wrap the exc ess c ab le as shown in Figure 4-13 and sec ure with the c lip s. 8. If using two ATM circuit pac ks, repeat steps 2 - 7. NOTE: In Step 3, use the b ottom op ening at the rear of the NAA1 c irc uit pack. In Step 5, use slot B in the fac ep late. In Step 7, use the lower set of c lip s to sec ure the exc ess c able. 9. Insert the NAA1 c irc uit p ac k into slot 11 on the top row of the c omp ac t modular cabinet. !CAUTION: Do not attemp t to p ut this c irc uit p ac k into any other slot; p in d amag e may occur. Table 4-10. Parts List Quantity Description Comcode 1 Fiber op tic interfac e kit Kit inc lud es: NAA1 c irc uit p ac k, 2 SC/SC c onnec tors, 2 SC/ST c onnec tors, and 4 c ables (2 for sing le mod e and 2 for multi-mod e).108424391
DEFINITY ECS Release 8.2 Installation, Upgrades, and Additions for Compact Modular Cabinets 555-233-118 Issue 1 April 2000 Adding or Removing Hardware 4-57 Add NAA1 Fiber Optic Circuit Pack 4 10. Route the c ab le(s) to the ATM c irc uit p ac k(s) and c onnec t them. NOTE: The loop formed b y the c ab le c onnec ting the two c irc uit pac ks must have a minimum rad ius of 1” (2.54 c m). If not, ad just the c ab le or move the ATM c irc uit p ac k to another loc ation. 11. Connec t the other eq uip ment into the c onnec tor(s) at the rear of the NAA1 circuit pack. 12. Rep lac e the c over. Figure 4-13. NAA1 Circuit Pack with Cables Attached A B A B ckdanaa1 LJK 021199 A B A B A B
DEFINITY ECS Release 8.2 Installation, Upgrades, and Additions for Compact Modular Cabinets 555-233-118 Issue 1 April 2000 Adding or Removing Hardware 4-58 Add NAA1 Fiber Optic Circuit Pack 4 Test the Installation of the ATM Circuit Pack 1. Log into the manag ement terminal. 2. Ad minister the system b y referring to ATM Installation, Up g rad es, and Ad ministration, 555-233-106. 3. Type list configuration all and p ress En t e r to determine if the new ATM c irc uit p ac k ap p ears in the c orrec t slot and that there are no c irc uit p ac k c onflic ts. The NAA1 c irc uit pac k will not be id entified in the list.