11.Carefully pull the atta chment clip forward until you can lift the bottom left corner of the Top Cover approximately 10 mm. 12. Lift the Top Cover of the printer sufficiently to gain access to the Front Panel ribbon cable. 13.Unroute the Front Panel ribbon cable from the two cable clamps on the bottom surface of the Top Cover. ENWW Top Cover 207
14.Lift the Top Cover off the printer. NOTE: When you finish installing or replacing this component, you must perform the necessary Service Calibrations. To find which ca librations you must perform, refer to Service Calibration Guide to Removal and Installation on page 170. Window Position Sensor Removal NOTE:Switch off the printer and remove the power cable. 1.Remove the Right Cover (refer Right Cover on page 185). 2. Remove the Left Cover (refer to Left Cover on page 188). 3. Remove the Front Panel (refer Front Panel on page 203). 4. Remove the Top Cover (refer Top Cover on page 205). 5. Disconnect the Window Position Sensor. 208 Chapter 6 Removal and Installation ENWW
6.Remove one T-15 screw that secures the Window Position Sensor to the printer. 7.Remove the Window Position Sensor to the printer. NOTE: When you finish installing or replacing this component, yo u must perform the necessary Service Calibrations. To find which calibrations you must perform, refer to Service Calibration Guide to Removal and Installation on page 170 . Ink Supply Tubes Support Rail Removal NOTE: Switch off the printer and remove the power cable. 1.Remove the Right Cover (refer Right Cover on page 185). 2. Remove the Left Cover (refer Left Cover on page 188). 3. Remove the Front Panel (refer Front Panel on page 203). 4. Remove the Top Cover (refer Top Cover on page 205). 5. Remove the Window Position Sensor (refer Window Position Sensor on page 208). ENWW Ink Supply Tubes Support Rail 209
6.Remove the Ink Supply Tubes from the Ink Supply Tubes Support Rail. 7.Remove the T-15 screws that secure the rear attachment brackets to the Ink Supply Tubes Support Rail. 8. Remove the T-15 screw that attaches the right bonding cable. 210 Chapter 6 Removal and Installation ENWW
9.Remove the T-15 screw that attaches the left bonding cable. 10.Remove the T-15 screw that attaches the left bonding cable. 11.Remove two T-15 screws that secure the Ink Supply Tubes Support Rail to the right Top Cover Support. ENWW Ink Supply Tubes Support Rail 211
12.Remove two T-15 screws that se cure the Ink Supply Tubes Support Rail to the left Top Cover Support. 13. Slide the rail enough to disengage it from the attachment lug. 14.Carefully slide the Ink Supply Tubes Support Rail to the left until the right end is clear of the right Top Cover Support. 212 Chapter 6 Removal and Installation ENWW
15.Remove the Ink Supply Tubes Support Rail from the printer. NOTE: When you reinstall the Ink Supply Tubes Support Rail make sure that the attachment lug is correctly engaged with the right Top Cover Support. NOTE: When you reinstall the Ink Supply Tubes Support Rail make sure all the attachment brackets and bonding leads are correctly connecte d. These are important to avoid electrostatic interference being generated. NOTE: When you finish installing or replacing this component, yo u must perform the necessary Service Calibrations. To find which calibrations you must perform, Refer to Service Calibration Guide to Removal and Installation on page 170. ENWW Ink Supply Tubes Support Rail 213
Service Station Removal NOTE:Switch off the printer and remove the power cable. 1.Remove the Right Cover (refer Right Cover on page 185). 2. Disconnect the Ink Supply Station ribbon connecto r and two lower connectors from the PrintMech PCA. NOTE: The Ink Supply Station ribbon connector has to be disconnected so the other cables can an be unrouted. 3. Unroute the two cables disconnected in step 2 from the two cable clamps below the PrintMech PCA. 4.Remove the grounding cable attachm ent screw from the PrintMech PCA. 214 Chapter 6 Removal and Installation ENWW
5.Disconnect connector from the Drop Dete ctor Motor and Drop Detector Sensor. 6.Unroute the cables disconnected in steps 4 and 5 from the two cable clamps. 7.Disconnect the Aerosol Fan Assembly inline connector. ENWW Service Station 215
8.Loosen the T-10 uncapping screw sufficiently so you can manually move the Carriage Assembly in step 9. 9. Push the Carriage Assembly into the print path to gain access to two T-15 screws that secure the Service Station to the Carriage Rail. 10. Use a allen key provided in the tool kit to remove two allen screws that secure the Service Station to the Carriage Rod. NOTE: Support the Service Station so it does not fall when you remove the attachment screws. 216 Chapter 6 Removal and Installation ENWW