    Catalyst 6500 Series Switches Installation Guide
    OL-5781-08
    Chapter 1      Product Overview
      Catalyst 6509-E Switch
    Power supplySupports one or two power supplies. The following models are 
    supported:
    –WS-CAC-2500W (2500 W AC-input power supply).
    –WS-CDC-2500W (2500 W DC-input power supply).
    –WS-CAC-3000W (3000 W AC-input power supply).
    –WS-CAC-4000W-US (4000 W AC-input power supply).
    –WS-CAC-4000W-INT (4000 W AC-input power supply).
    –PWR-4000-DC (4000 W DC-input power supply).
    –WS-CAC-6000W (6000 W AC-input power supply).
    –PWR-6000-DC (6000 W DC-input power supply).
    –WS-CAC-8700W-E (8700 W AC-input power supply).
    Installed power supplies can be of different wattage ratings. Installed 
    power supplies can also be both AC-input, both DC-input, or one 
    AC-input and one DC-input. Power supplies can be configured in either 
    redundant or combined mode.
    All Catalyst 6500 series AC-input power supplies require single-phase 
    source AC. Source AC can be out of phase between multiple power 
    supplies or multiple AC-power plugs on the same power supply because 
    all AC power supply inputs are isolated.
    Supervisor Engine 2T requires a 3000 W or greater power supply to 
    operate.
    NoteFor proper operation of the power supply OUTPUT FAIL LED, 
    systems with single power supplies must be configured with a 
    minimum of one fan tray and one supervisor engine. Systems with 
    dual power supplies must have a minimum configuration of one fan 
    tray, one supervisor engine, and one additional module. Failure to 
    meet these minimum configuration requirements can cause a false 
    power supply output fail signal.
    Table 1-13 Catalyst 6509-E Switch Features (continued)
    Feature Description 
    						
    							1-40
    Catalyst 6500 Series Switches Installation Guide
    OL-5781-08
    Chapter 1      Product Overview
      Catalyst 6509-E Switch
    Table 1-14 lists the environmental and physical specifications of the Catalyst 6509-E switch chassis.
    Table 1-14 Catalyst 6509-E Switch Specifications
    Item Specification
    Environmental
    Temperature, operating Certified for operation: 32° to 104°F (0° to 40°C)
    Designed and tested for operation: 32° to 131°F (0° to 55°C)
    NoteThe Catalyst 6500 series switches are equipped with internal air 
    temperature sensors that are triggered at 104°F (40°C) generating a 
    minor alarm and at 131°F (55°C) generating a major alarm.
    Temperature, nonoperating 
    and storageChassis unpackaged: –4° to 149°F (–20° to 65°C)
    Chassis in protective shipping package: –40° to 158°F (–40° to 70°C)
    Thermal transition 0.5°C per minute (hot to cold)
    0.33°C per minute (cold to hot)
    Humidity (RH), ambient 
    (noncondensing) operating 5% to 90%
    Humidity (RH), ambient 
    (noncondensing) 
    nonoperating and storage 5% to 95% 
    Altitude, operating Certified for operation: 0 to 6500 ft (0 to 2000 m)
    Designed and tested for operation: –200 to 10,000 ft (–60 to 3000 m)
    Shock and vibration This switch complies with Network Equipment Building Systems (NEBS) 
    (Zone 4 per GR-63-Core) in the following areas:
    Earthquake environment and criteria
    Office vibration and criteria
    Transportation vibration and criteria
    Shock
    
    Operational—5 G 30 ms, half-sine (IEC 68-2-27)
    Nonoperational—20 G, 7.5 ms, trapezoidal
    Vibration 
    Operational—3 Hz to 500 Hz. 
    Power Spectral Density (PSD)—0.0005 G2/Hz at 10 Hz and 200 Hz. 
    5 dB/octave roll off at each end. 0.5 hours per axis (1.12 Grms).
    Acoustic noise 67 dB. International Organization for Standardization (ISO) 7779: 
    Bystander position operating to an ambient temperature of 86°F (30°C). 
    						
    							1-41
    Catalyst 6500 Series Switches Installation Guide
    OL-5781-08
    Chapter 1      Product Overview
      Catalyst 6509-E Switch
    Physical characteristics
    Dimensions (H x W x D)
    24.5 x 17.5 x 18.2 in. (62.2 x 44.5 x 46.0 cm).
    Chassis depth including cable guide is 21.64 in. (55.0 cm). 
    Chassis requires 15 RU1.
    The Catalyst 6509-E switch chassis is designed to install in standard 
    19-inch equipment racks that meet ANSI/EIA 310-D, IEC 60297, and 
    ETS 300-119 standards.
    Weight Chassis only: 60 lb (27.3 kg).
    Chassis fully configured with 1 supervisor engine, 8 switching modules, and 
    2 power supplies: 190 lb (86.4 kg).
    Airflow WS-C6509-E-FAN—846 CFM
    NoteTo maintain proper air circulation through the Catalyst switch 
    chassis, we recommend that you maintain a minimum 6-inch (15 cm) 
    separation between a wall and the chassis air intake or a wall and the 
    chassis air exhaust. You should also allow a minimum separation of 
    12 inches (30.5 cm) between the hot air exhaust on one chassis and 
    the air intake on another chassis. Failure to maintain adequate air 
    space can cause the chassis to overheat and the system to fail. On 
    Catalyst chassis in which the airflow is from front to back, the 
    chassis may be placed side-by-side. 
    1. RU = rack units
    Table 1-14 Catalyst 6509-E Switch Specifications (continued)
    Item Specification 
    						
    							1-42
    Catalyst 6500 Series Switches Installation Guide
    OL-5781-08
    Chapter 1      Product Overview
      Catalyst 6509-NEB Switch
    Catalyst 6509-NEB Switch
    The Catalyst 6509-NEB switch is a 9-slot vertical chassis supporting redundant power supplies, 
    redundant supervisor engines, and slots for up to eight modules. The chassis is NEBS L3 compliant. 
    Figure 1-11 shows the Catalyst 6509-NEB switch chassis.
    Figure 1-11 Catalyst 6509-NEB Switch
    INPUT
    OKFA N
    OKOUTPUT
    FA I
    L
    o
    INPUT
    OKFA N
    OKOUTPUT
    FA I
    L
    o
    FA N
    STATUS
    30695
    8 PORT GIGABIT ETHER
    NETWS-X6408
    1LINKSTA
    TUS
    2
    3
    45
    6
    7
    8LINK
    LINK
    LINK
    LINK
    LINK
    LINK
    LINK
    8 PORT GIGABIT ETHER
    NETWS-X6408
    1LINKSTA
    TUS
    2
    3
    45
    6
    7
    8LINK
    LINK
    LINK
    LINK
    LINK
    LINK
    LINK
    8 PORT GIGABIT ETHER
    NETWS-X6408
    1LINKSTATUS
    2
    3
    45
    6
    7
    8LINK
    LINK
    LINK
    LINK
    LINK
    LINK
    LINK
    8 PORT GIGABIT ETHER
    NETWS-X6408
    1LINKSTATUS
    2
    3
    45
    6
    7
    8LINK
    LINK
    LINK
    LINK
    LINK
    LINK
    LINK
    24 PORT 100FXWS-X6224STATUS1L
    IN
    K2L
    IN
    K3LINK4LINK5L
    IN
    K6LIN
    K7LINK8LIN
    K9LINK1
    0LIN
    K1
    1L
    IN
    K1
    2L
    IN
    K1
    3LINK1
    4LIN
    K1
    5LIN
    K1
    6LIN
    K1
    7L
    IN
    K1
    8LINK1
    9LINK2
    0L
    INK2
    1LIN
    K2
    2LINK2
    3L
    IN
    K2
    4LINK
    Slots 1-9
    (right to left)
    Power supply 1Power supply 2
    (redundant)
    ESD ground strap
    connection
    W
    S
    -S
    U
    P32
    -GE
    -3
    BSTATUS
    SYST
    EM
    ACT
    IVE
    PWR
     MG
    MT
    RES
    ETC
    A
    TA
    L
    YS
    T
       6
    500
     SU
    P
    E
    RV
    IS
    O
    R
      E
    N
    G
    IN
    E
      32
    C
    O
    N
    S
    O
    L
    E
    E
    J
    EC
    TD
    IS
    K
     0P
    O
    R
    T
     1
    P
    O
    R
    T 2
    P
    O
    R
    T 3
    P
    O
    R
    T 4P
    O
    R
    T 5
    P
    O
    R
    T 6
    P
    O
    R
    T
     7P
    O
    R
    T 8P
    O
    R
    T 9
    U
    S
    B 2
    .0
    LIN
    K
    LINK
    LINK
    LINK
    LINK
    LINK
    LINK
    LIN
    K
    LINK
    W
    S
    -S
    U
    P32
    -G
    E
    -3
    BSTA
    TUS
    SYST
    EM
    ACT
    IVE
    PWR
     MG
    MT
    RES
    ETC
    A
    T
    A
    L
    YS
    T
       6
    500
     SU
    P
    E
    RV
    IS
    O
    R
      E
    N
    G
    IN
    E
      32
    C
    O
    N
    S
    O
    L
    E
    E
    J
    EC
    TD
    IS
    K
     0P
    O
    R
    T 1
    P
    O
    R
    T 2
    P
    O
    R
    T
     3
    P
    O
    R
    T 4P
    O
    R
    T
     5
    P
    O
    R
    T 6
    P
    O
    R
    T
     7P
    O
    R
    T 8P
    O
    R
    T 9
    U
    S
    B 2
    .0
    LIN
    K
    LIN
    K
    LIN
    K
    LINK
    LINK
    LINK
    LINK
    LINK
    LINK
    8 PORT GIGABIT ETHER
    NETWS-X6408
    1LINKSTA
    TUS
    2
    3
    45
    6
    7
    8LINK
    LINK
    LINK
    LINK
    LINK
    LINK
    LINK
    24 PORT 100FXWS-X6224STATUS1LI
    NK2LINK3LIN
    K4LIN
    K5L
    INK6LINK7L
    INK8LIN
    K9LIN
    K1
    0LINK1
    1LIN
    K1
    2L
    IN
    K1
    3LINK1
    4LIN
    K1
    5LINK1
    6L
    IN
    K1
    7L
    IN
    K1
    8LINK1
    9LINK2
    0LIN
    K2
    1LIN
    K2
    2LINK2
    3LINK2
    4LIN
    K
    Switching
    modules
    Fan
    assembly
    Supervisor
    engine
    Redundant
    supervisor
    engine 
    						
    							1-43
    Catalyst 6500 Series Switches Installation Guide
    OL-5781-08
    Chapter 1      Product Overview
      Catalyst 6509-NEB Switch
    Ta b l e 1 - 1 5 lists the features of the Catalyst 6509-NEB switch chassis. 
    Table 1-15 Catalyst 6509-NEB Switch Features
    Feature Features
    Chassis
    Nine vertical slots. Slots are numbered from 1 (right) to 9 (left).
    Supervisor engines
    Supports Supervisor Engine 2, Supervisor Engine 32, Supervisor 
    Engine 32 PISA, Supervisor Engine 720, and Supervisor 
    Engine 720-10GE.
    NoteRefer to your software release notes for the minimum software 
    release versions required to support the supervisor engines.
    –Supervisor Engine 2 must be installed in slot 1 or slot 2.
    –Supervisor Engine 32, Supervisor Engine 32 PISA, Supervisor 
    Engine 720, and Supervisor Engine 720-10GE. must be installed in 
    slot 5 or slot 6.
    NoteSupervisor Engine 32, Supervisor Engine 32 PISA, Supervisor 
    Engine 720, and Supervisor Engine 720-10GE are supported if the 
    WS-6509-NEB-UPGRD kit is installed.
    NoteSlots not occupied by supervisor engines can be used for modules. 
    Check your software release notes for any restrictions on the type of 
    module that can be installed.
    Supervisor Engine 720 and Supervisor Engine 720-10GE have a built-in 
    switching fabric. Switch Fabric Modules (WS-C6500-SFM and 
    WS-X6500-SFM2) are not supported by Supervisor Engine 720. You 
    cannot install the Switch Fabric Modules and the Supervisor Engine 720 
    or the Supervisor Engine 720-10GE in the same chassis.
    Supervisor Engine 32 and Supervisor Engine 32 PISA do not support 
    the Switch Fabric Modules (WS-C6500-SFM and WS-X6500-SFM2). 
    You cannot install the Switch Fabric Modules and the Supervisor 
    Engine 32 or the Supervisor Engine 32 PISA in the same chassis.
    The uplink ports are fully functional on all redundant supervisor engine 
    models when they are in standby mode. 
    NoteIn systems with redundant supervisor engines, both supervisor 
    engines must be the same model and have the same daughter card 
    configurations. Each supervisor engine must have the resources to 
    run the switch on its own, which means that all supervisor engine 
    resources are duplicated. Identical supervisor engine memory 
    configurations are recommended, but are not required as long as the 
    supervisor engine with the smaller memory configuration is 
    sufficient to run the configured features of the switch. Additionally, 
    each supervisor engine must have its own flash device and console 
    port connections. 
    						
    							1-44
    Catalyst 6500 Series Switches Installation Guide
    OL-5781-08
    Chapter 1      Product Overview
      Catalyst 6509-NEB Switch
    ModulesSupports up to eight Catalyst 6500 series modules.
    WS-C6500-SFM and WS-X6500-SFM2 Switch Fabric Modules must be 
    installed in slot 5 or slot 6.
    NoteMixing WS-C6500-SFM and WS-X6500-SFM2 Switch Fabric 
    Modules in the Catalyst 6509-NEB chassis is allowed.
    Some Catalyst 6500 series modules may:
    –Not be supported
    –Require that you install a Supervisor Engine 720
    –Have chassis slot restrictions
    –Require a specific software release level to operate
    NoteCheck your software release notes for specific information.
    Backplane bandwidth
    32 GBps shared bus.
    256 GBps switch fabric.
    720 GBps switch fabric.
    Clock and VTT modules
    Two replaceable clock modules (WS-C6K-CL=) provide clocking 
    signals to the EOBC channel and the switching bus.
    Three replaceable voltage termination (VTT) modules 
    (WS-C6K-VTT=) provide reference voltage for bus signals.
    Table 1-15 Catalyst 6509-NEB Switch Features (continued)
    Feature Features 
    						
    							1-45
    Catalyst 6500 Series Switches Installation Guide
    OL-5781-08
    Chapter 1      Product Overview
      Catalyst 6509-NEB Switch
    Fan trayThe chassis supports one hot-swappable fan tray. Two fan tray models 
    are available:
    –WS-C6509-NEB-FAN (Standard fan tray—294 CFM). Supports 
    Supervisor Engine 1 and Supervisor Engine 2 only; does not 
    support Supervisor Engine 32, Supervisor Engine 32 PISA, 
    Supervisor Engine 720, or Supervisor Engine 720-10GE. 
    –WS-6509-NEB-UPGRD1—630 CFM (The high-speed fan tray 
    (WS-C6509-NEB-FAN2) is a part of the upgrade kit). This kit must 
    be installed if you are installing a Supervisor Engine 32 or a 
    Supervisor Engine 720 in the Catalyst 6509-NEB switch. The kit 
    contains a high-speed fan tray, back panel, and power harness. If 
    you are operating the chassis from an AC source, you will also need 
    to order a 3000 W AC-input power supply which has a front panel 
    DC power connector. The upgrade kit fan tray receives 42 VDC 
    power from this front panel DC power connector through a power 
    harness also provided in the upgrade kit. If you are operating the 
    chassis from a DC source, you can power the system with either the 
    2500 W or 4000 W DC-input power supplies and power the upgrade 
    fan tray from the site source DC.
    NoteBoth fan tray models contain nine individual fans. The individual 
    fans are not field replaceable; you must replace the fan tray in the 
    event of a fan failure.
    Fan tray STATUS LED
    –Red—One or more individual fans have failed.
    –Green—Fan tray is operating normally.
    Table 1-15 Catalyst 6509-NEB Switch Features (continued)
    Feature Features 
    						
    							1-46
    Catalyst 6500 Series Switches Installation Guide
    OL-5781-08
    Chapter 1      Product Overview
      Catalyst 6509-NEB Switch
    Power supplySupports one or two power supplies. The following models are 
    supported:
    –WS-CAC-2500W (2500 W AC-input power supply).
    –WS-CDC-2500W (2500 W DC-input power supply).
    –WS-CAC-3000W (3000 W AC-input power supply).
    –WS-CAC-4000W-US (4000 W AC-input power supply).
    –WS-CAC-4000W-INT (4000 W AC-input power supply).
    –PWR-4000-DC (4000 W DC-input power supply).
    –WS-CAC-6000W (6000 W AC-input power supply).
    –PWR-6000-DC (6000 W DC-input power supply).
    –WS-CAC-8700W-E (8700 W AC-input power supply).
    NoteThe 6000 W AC-input and DC-input power supplies and the 8700 W 
    AC-input power supply are limited to 4000 W maximum output 
    when installed in the Catalyst 6509-NEB chassis.
    Installed power supplies can be of different wattage ratings. Installed 
    power supplies can also be both AC-input, both DC-input, or one 
    AC-input and one DC-input. Power supplies can be configured in either 
    redundant or combined mode.
    All Catalyst 6500 series AC-input power supplies require single-phase 
    source AC. Source AC can be out of phase between multiple power 
    supplies or multiple AC-power plugs on the same power supply because 
    all AC power supply inputs are isolated.
    Single power supplies are installed in the left power supply bay. The 
    second power supply is installed in the right power supply bay.
    NoteFor proper operation of the power supply OUTPUT FAIL LED, 
    systems with single power supplies must be configured with a 
    minimum of one fan tray and one supervisor engine. Systems with 
    dual power supplies must have a minimum configuration of one fan 
    tray, one supervisor engine, and one additional module. Failure to 
    meet these minimum configuration requirements can cause a false 
    power supply output fail signal.
    1. Refer to the Catalyst 6509-NEB Switch and Cisco OSR-7609 Router Upgrade Note for kit installation instructions.
    Table 1-15 Catalyst 6509-NEB Switch Features (continued)
    Feature Features 
    						
    							1-47
    Catalyst 6500 Series Switches Installation Guide
    OL-5781-08
    Chapter 1      Product Overview
      Catalyst 6509-NEB Switch
    Ta b l e 1 - 1 6 lists the environmental and physical specifications of the Catalyst 6509-NEB switch chassis.
    Table 1-16 Catalyst 6509-NEB Switch Specifications
    Item Specification
    Environmental
    Temperature, operating Certified for operation: 32° to 104°F (0° to 40°C)
    Designed and tested for operation: 32° to 131°F (0° to 55°C)
    NoteThe Catalyst 6500 series switches are equipped with internal air 
    temperature sensors that are triggered at 104°F (40°C) generating a 
    minor alarm and at 131°F (55°C) generating a major alarm.
    Temperature, nonoperating 
    and storageChassis unpackaged: –4° to 149°F (–20° to 65°C)
    Chassis in protective shipping package: –40° to 158°F (–40° to 70°C)
    Thermal transition 0.5°C per minute (hot to cold)
    0.33°C per minute (cold to hot)
    Humidity (RH), ambient 
    (noncondensing) operating 5% to 90%
    Humidity (RH), ambient 
    (noncondensing) 
    nonoperating and storage 5% to 95% 
    Altitude, operating Certified for operation: 0 to 6500 ft (0 to 2000 m)
    Designed and tested for operation: –200 to 10,000 ft (–60 to 3000 m)
    Shock and vibration This switch complies with Network Equipment Building Systems (NEBS) 
    (Zone 4 per GR-63-Core) in the following areas:
    Earthquake environment and criteria
    Office vibration and criteria
    Transportation vibration and criteria
    Shock
    
    Operational—5 G 30 ms, half-sine (IEC 68-2-27)
    Nonoperational—20 G, 7.5 ms, trapezoidal
    Vibration 
    Operational—3 Hz to 500 Hz. 
    Power Spectral Density (PSD)—0.0005 G2/Hz at 10 Hz and 200 Hz. 
    5 dB/octave roll off at each end. 0.5 hours per axis (1.12 Grms).
    Acoustic noise 56.4 to 75 dB. International Organization for Standardization (ISO) 7779: 
    Bystander position operating to an ambient temperature of 86°F (30°C). 
    						
    							1-48
    Catalyst 6500 Series Switches Installation Guide
    OL-5781-08
    Chapter 1      Product Overview
      Catalyst 6509-NEB Switch
    Physical characteristics
    Dimensions (H x W x D)
    33.3 x 17.2 x 18.1 in. (84.6 x 43.7 x 46.0 cm). 
    Chassis requires 20 RU1.
    The Catalyst 6509-NEB switch chassis is designed to install in standard 
    19-inch equipment racks that meet ANSI/EIA 310-D, IEC 60297, and 
    ETS 300-119 standards.
    Weight Chassis only: 55 lb (24.9 kg).
    Chassis fully configured with 1 supervisor engine, 8 switching modules, and 
    2 power supplies: 135 lb (61.2 kg).
    Airflow
    WS-C6509-NEB-FAN (Standard fan tray)—294 CFM
    Optional high-speed fan tray2—630 CFM
    NoteTo maintain proper air circulation through the Catalyst switch 
    chassis, we recommend that you maintain a minimum 6-inch (15 cm) 
    separation between a wall and the chassis air intake or a wall and the 
    chassis air exhaust. You should also allow a minimum separation of 
    12 inches (30.5 cm) between the hot air exhaust on one chassis and 
    the air intake on another chassis. Failure to maintain adequate air 
    space can cause the chassis to overheat and the system to fail. On 
    Catalyst chassis in which the airflow is from front to back, the 
    chassis may be placed side-by-side. 
    1. RU = rack units.
    2. Part of the WS-6509-NEB-UPGRD kit.
    Table 1-16 Catalyst 6509-NEB Switch Specifications (continued)
    Item Specification 
    						