1-39 Catalyst 6500 Series Switches Installation Guide OL-5781-08 Chapter 1 Product Overview Catalyst 6509-E Switch Power supplySupports one or two power supplies. The following models are supported: –WS-CAC-2500W (2500 W AC-input power supply). –WS-CDC-2500W (2500 W DC-input power supply). –WS-CAC-3000W (3000 W AC-input power supply). –WS-CAC-4000W-US (4000 W AC-input power supply). –WS-CAC-4000W-INT (4000 W AC-input power supply). –PWR-4000-DC (4000 W DC-input power supply). –WS-CAC-6000W (6000 W AC-input power supply). –PWR-6000-DC (6000 W DC-input power supply). –WS-CAC-8700W-E (8700 W AC-input power supply). Installed power supplies can be of different wattage ratings. Installed power supplies can also be both AC-input, both DC-input, or one AC-input and one DC-input. Power supplies can be configured in either redundant or combined mode. All Catalyst 6500 series AC-input power supplies require single-phase source AC. Source AC can be out of phase between multiple power supplies or multiple AC-power plugs on the same power supply because all AC power supply inputs are isolated. Supervisor Engine 2T requires a 3000 W or greater power supply to operate. NoteFor proper operation of the power supply OUTPUT FAIL LED, systems with single power supplies must be configured with a minimum of one fan tray and one supervisor engine. Systems with dual power supplies must have a minimum configuration of one fan tray, one supervisor engine, and one additional module. Failure to meet these minimum configuration requirements can cause a false power supply output fail signal. Table 1-13 Catalyst 6509-E Switch Features (continued) Feature Description
1-40 Catalyst 6500 Series Switches Installation Guide OL-5781-08 Chapter 1 Product Overview Catalyst 6509-E Switch Table 1-14 lists the environmental and physical specifications of the Catalyst 6509-E switch chassis. Table 1-14 Catalyst 6509-E Switch Specifications Item Specification Environmental Temperature, operating Certified for operation: 32° to 104°F (0° to 40°C) Designed and tested for operation: 32° to 131°F (0° to 55°C) NoteThe Catalyst 6500 series switches are equipped with internal air temperature sensors that are triggered at 104°F (40°C) generating a minor alarm and at 131°F (55°C) generating a major alarm. Temperature, nonoperating and storageChassis unpackaged: –4° to 149°F (–20° to 65°C) Chassis in protective shipping package: –40° to 158°F (–40° to 70°C) Thermal transition 0.5°C per minute (hot to cold) 0.33°C per minute (cold to hot) Humidity (RH), ambient (noncondensing) operating 5% to 90% Humidity (RH), ambient (noncondensing) nonoperating and storage 5% to 95% Altitude, operating Certified for operation: 0 to 6500 ft (0 to 2000 m) Designed and tested for operation: –200 to 10,000 ft (–60 to 3000 m) Shock and vibration This switch complies with Network Equipment Building Systems (NEBS) (Zone 4 per GR-63-Core) in the following areas: Earthquake environment and criteria Office vibration and criteria Transportation vibration and criteria Shock Operational—5 G 30 ms, half-sine (IEC 68-2-27) Nonoperational—20 G, 7.5 ms, trapezoidal Vibration Operational—3 Hz to 500 Hz. Power Spectral Density (PSD)—0.0005 G2/Hz at 10 Hz and 200 Hz. 5 dB/octave roll off at each end. 0.5 hours per axis (1.12 Grms). Acoustic noise 67 dB. International Organization for Standardization (ISO) 7779: Bystander position operating to an ambient temperature of 86°F (30°C).
1-41 Catalyst 6500 Series Switches Installation Guide OL-5781-08 Chapter 1 Product Overview Catalyst 6509-E Switch Physical characteristics Dimensions (H x W x D) 24.5 x 17.5 x 18.2 in. (62.2 x 44.5 x 46.0 cm). Chassis depth including cable guide is 21.64 in. (55.0 cm). Chassis requires 15 RU1. The Catalyst 6509-E switch chassis is designed to install in standard 19-inch equipment racks that meet ANSI/EIA 310-D, IEC 60297, and ETS 300-119 standards. Weight Chassis only: 60 lb (27.3 kg). Chassis fully configured with 1 supervisor engine, 8 switching modules, and 2 power supplies: 190 lb (86.4 kg). Airflow WS-C6509-E-FAN—846 CFM NoteTo maintain proper air circulation through the Catalyst switch chassis, we recommend that you maintain a minimum 6-inch (15 cm) separation between a wall and the chassis air intake or a wall and the chassis air exhaust. You should also allow a minimum separation of 12 inches (30.5 cm) between the hot air exhaust on one chassis and the air intake on another chassis. Failure to maintain adequate air space can cause the chassis to overheat and the system to fail. On Catalyst chassis in which the airflow is from front to back, the chassis may be placed side-by-side. 1. RU = rack units Table 1-14 Catalyst 6509-E Switch Specifications (continued) Item Specification
1-42 Catalyst 6500 Series Switches Installation Guide OL-5781-08 Chapter 1 Product Overview Catalyst 6509-NEB Switch Catalyst 6509-NEB Switch The Catalyst 6509-NEB switch is a 9-slot vertical chassis supporting redundant power supplies, redundant supervisor engines, and slots for up to eight modules. The chassis is NEBS L3 compliant. Figure 1-11 shows the Catalyst 6509-NEB switch chassis. Figure 1-11 Catalyst 6509-NEB Switch INPUT OKFA N OKOUTPUT FA I L o INPUT OKFA N OKOUTPUT FA I L o FA N STATUS 30695 8 PORT GIGABIT ETHER NETWS-X6408 1LINKSTA TUS 2 3 45 6 7 8LINK LINK LINK LINK LINK LINK LINK 8 PORT GIGABIT ETHER NETWS-X6408 1LINKSTA TUS 2 3 45 6 7 8LINK LINK LINK LINK LINK LINK LINK 8 PORT GIGABIT ETHER NETWS-X6408 1LINKSTATUS 2 3 45 6 7 8LINK LINK LINK LINK LINK LINK LINK 8 PORT GIGABIT ETHER NETWS-X6408 1LINKSTATUS 2 3 45 6 7 8LINK LINK LINK LINK LINK LINK LINK 24 PORT 100FXWS-X6224STATUS1L IN K2L IN K3LINK4LINK5L IN K6LIN K7LINK8LIN K9LINK1 0LIN K1 1L IN K1 2L IN K1 3LINK1 4LIN K1 5LIN K1 6LIN K1 7L IN K1 8LINK1 9LINK2 0L INK2 1LIN K2 2LINK2 3L IN K2 4LINK Slots 1-9 (right to left) Power supply 1Power supply 2 (redundant) ESD ground strap connection W S -S U P32 -GE -3 BSTATUS SYST EM ACT IVE PWR MG MT RES ETC A TA L YS T 6 500 SU P E RV IS O R E N G IN E 32 C O N S O L E E J EC TD IS K 0P O R T 1 P O R T 2 P O R T 3 P O R T 4P O R T 5 P O R T 6 P O R T 7P O R T 8P O R T 9 U S B 2 .0 LIN K LINK LINK LINK LINK LINK LINK LIN K LINK W S -S U P32 -G E -3 BSTA TUS SYST EM ACT IVE PWR MG MT RES ETC A T A L YS T 6 500 SU P E RV IS O R E N G IN E 32 C O N S O L E E J EC TD IS K 0P O R T 1 P O R T 2 P O R T 3 P O R T 4P O R T 5 P O R T 6 P O R T 7P O R T 8P O R T 9 U S B 2 .0 LIN K LIN K LIN K LINK LINK LINK LINK LINK LINK 8 PORT GIGABIT ETHER NETWS-X6408 1LINKSTA TUS 2 3 45 6 7 8LINK LINK LINK LINK LINK LINK LINK 24 PORT 100FXWS-X6224STATUS1LI NK2LINK3LIN K4LIN K5L INK6LINK7L INK8LIN K9LIN K1 0LINK1 1LIN K1 2L IN K1 3LINK1 4LIN K1 5LINK1 6L IN K1 7L IN K1 8LINK1 9LINK2 0LIN K2 1LIN K2 2LINK2 3LINK2 4LIN K Switching modules Fan assembly Supervisor engine Redundant supervisor engine
1-43 Catalyst 6500 Series Switches Installation Guide OL-5781-08 Chapter 1 Product Overview Catalyst 6509-NEB Switch Ta b l e 1 - 1 5 lists the features of the Catalyst 6509-NEB switch chassis. Table 1-15 Catalyst 6509-NEB Switch Features Feature Features Chassis Nine vertical slots. Slots are numbered from 1 (right) to 9 (left). Supervisor engines Supports Supervisor Engine 2, Supervisor Engine 32, Supervisor Engine 32 PISA, Supervisor Engine 720, and Supervisor Engine 720-10GE. NoteRefer to your software release notes for the minimum software release versions required to support the supervisor engines. –Supervisor Engine 2 must be installed in slot 1 or slot 2. –Supervisor Engine 32, Supervisor Engine 32 PISA, Supervisor Engine 720, and Supervisor Engine 720-10GE. must be installed in slot 5 or slot 6. NoteSupervisor Engine 32, Supervisor Engine 32 PISA, Supervisor Engine 720, and Supervisor Engine 720-10GE are supported if the WS-6509-NEB-UPGRD kit is installed. NoteSlots not occupied by supervisor engines can be used for modules. Check your software release notes for any restrictions on the type of module that can be installed. Supervisor Engine 720 and Supervisor Engine 720-10GE have a built-in switching fabric. Switch Fabric Modules (WS-C6500-SFM and WS-X6500-SFM2) are not supported by Supervisor Engine 720. You cannot install the Switch Fabric Modules and the Supervisor Engine 720 or the Supervisor Engine 720-10GE in the same chassis. Supervisor Engine 32 and Supervisor Engine 32 PISA do not support the Switch Fabric Modules (WS-C6500-SFM and WS-X6500-SFM2). You cannot install the Switch Fabric Modules and the Supervisor Engine 32 or the Supervisor Engine 32 PISA in the same chassis. The uplink ports are fully functional on all redundant supervisor engine models when they are in standby mode. NoteIn systems with redundant supervisor engines, both supervisor engines must be the same model and have the same daughter card configurations. Each supervisor engine must have the resources to run the switch on its own, which means that all supervisor engine resources are duplicated. Identical supervisor engine memory configurations are recommended, but are not required as long as the supervisor engine with the smaller memory configuration is sufficient to run the configured features of the switch. Additionally, each supervisor engine must have its own flash device and console port connections.
1-44 Catalyst 6500 Series Switches Installation Guide OL-5781-08 Chapter 1 Product Overview Catalyst 6509-NEB Switch ModulesSupports up to eight Catalyst 6500 series modules. WS-C6500-SFM and WS-X6500-SFM2 Switch Fabric Modules must be installed in slot 5 or slot 6. NoteMixing WS-C6500-SFM and WS-X6500-SFM2 Switch Fabric Modules in the Catalyst 6509-NEB chassis is allowed. Some Catalyst 6500 series modules may: –Not be supported –Require that you install a Supervisor Engine 720 –Have chassis slot restrictions –Require a specific software release level to operate NoteCheck your software release notes for specific information. Backplane bandwidth 32 GBps shared bus. 256 GBps switch fabric. 720 GBps switch fabric. Clock and VTT modules Two replaceable clock modules (WS-C6K-CL=) provide clocking signals to the EOBC channel and the switching bus. Three replaceable voltage termination (VTT) modules (WS-C6K-VTT=) provide reference voltage for bus signals. Table 1-15 Catalyst 6509-NEB Switch Features (continued) Feature Features
1-45 Catalyst 6500 Series Switches Installation Guide OL-5781-08 Chapter 1 Product Overview Catalyst 6509-NEB Switch Fan trayThe chassis supports one hot-swappable fan tray. Two fan tray models are available: –WS-C6509-NEB-FAN (Standard fan tray—294 CFM). Supports Supervisor Engine 1 and Supervisor Engine 2 only; does not support Supervisor Engine 32, Supervisor Engine 32 PISA, Supervisor Engine 720, or Supervisor Engine 720-10GE. –WS-6509-NEB-UPGRD1—630 CFM (The high-speed fan tray (WS-C6509-NEB-FAN2) is a part of the upgrade kit). This kit must be installed if you are installing a Supervisor Engine 32 or a Supervisor Engine 720 in the Catalyst 6509-NEB switch. The kit contains a high-speed fan tray, back panel, and power harness. If you are operating the chassis from an AC source, you will also need to order a 3000 W AC-input power supply which has a front panel DC power connector. The upgrade kit fan tray receives 42 VDC power from this front panel DC power connector through a power harness also provided in the upgrade kit. If you are operating the chassis from a DC source, you can power the system with either the 2500 W or 4000 W DC-input power supplies and power the upgrade fan tray from the site source DC. NoteBoth fan tray models contain nine individual fans. The individual fans are not field replaceable; you must replace the fan tray in the event of a fan failure. Fan tray STATUS LED –Red—One or more individual fans have failed. –Green—Fan tray is operating normally. Table 1-15 Catalyst 6509-NEB Switch Features (continued) Feature Features
1-46 Catalyst 6500 Series Switches Installation Guide OL-5781-08 Chapter 1 Product Overview Catalyst 6509-NEB Switch Power supplySupports one or two power supplies. The following models are supported: –WS-CAC-2500W (2500 W AC-input power supply). –WS-CDC-2500W (2500 W DC-input power supply). –WS-CAC-3000W (3000 W AC-input power supply). –WS-CAC-4000W-US (4000 W AC-input power supply). –WS-CAC-4000W-INT (4000 W AC-input power supply). –PWR-4000-DC (4000 W DC-input power supply). –WS-CAC-6000W (6000 W AC-input power supply). –PWR-6000-DC (6000 W DC-input power supply). –WS-CAC-8700W-E (8700 W AC-input power supply). NoteThe 6000 W AC-input and DC-input power supplies and the 8700 W AC-input power supply are limited to 4000 W maximum output when installed in the Catalyst 6509-NEB chassis. Installed power supplies can be of different wattage ratings. Installed power supplies can also be both AC-input, both DC-input, or one AC-input and one DC-input. Power supplies can be configured in either redundant or combined mode. All Catalyst 6500 series AC-input power supplies require single-phase source AC. Source AC can be out of phase between multiple power supplies or multiple AC-power plugs on the same power supply because all AC power supply inputs are isolated. Single power supplies are installed in the left power supply bay. The second power supply is installed in the right power supply bay. NoteFor proper operation of the power supply OUTPUT FAIL LED, systems with single power supplies must be configured with a minimum of one fan tray and one supervisor engine. Systems with dual power supplies must have a minimum configuration of one fan tray, one supervisor engine, and one additional module. Failure to meet these minimum configuration requirements can cause a false power supply output fail signal. 1. Refer to the Catalyst 6509-NEB Switch and Cisco OSR-7609 Router Upgrade Note for kit installation instructions. Table 1-15 Catalyst 6509-NEB Switch Features (continued) Feature Features
1-47 Catalyst 6500 Series Switches Installation Guide OL-5781-08 Chapter 1 Product Overview Catalyst 6509-NEB Switch Ta b l e 1 - 1 6 lists the environmental and physical specifications of the Catalyst 6509-NEB switch chassis. Table 1-16 Catalyst 6509-NEB Switch Specifications Item Specification Environmental Temperature, operating Certified for operation: 32° to 104°F (0° to 40°C) Designed and tested for operation: 32° to 131°F (0° to 55°C) NoteThe Catalyst 6500 series switches are equipped with internal air temperature sensors that are triggered at 104°F (40°C) generating a minor alarm and at 131°F (55°C) generating a major alarm. Temperature, nonoperating and storageChassis unpackaged: –4° to 149°F (–20° to 65°C) Chassis in protective shipping package: –40° to 158°F (–40° to 70°C) Thermal transition 0.5°C per minute (hot to cold) 0.33°C per minute (cold to hot) Humidity (RH), ambient (noncondensing) operating 5% to 90% Humidity (RH), ambient (noncondensing) nonoperating and storage 5% to 95% Altitude, operating Certified for operation: 0 to 6500 ft (0 to 2000 m) Designed and tested for operation: –200 to 10,000 ft (–60 to 3000 m) Shock and vibration This switch complies with Network Equipment Building Systems (NEBS) (Zone 4 per GR-63-Core) in the following areas: Earthquake environment and criteria Office vibration and criteria Transportation vibration and criteria Shock Operational—5 G 30 ms, half-sine (IEC 68-2-27) Nonoperational—20 G, 7.5 ms, trapezoidal Vibration Operational—3 Hz to 500 Hz. Power Spectral Density (PSD)—0.0005 G2/Hz at 10 Hz and 200 Hz. 5 dB/octave roll off at each end. 0.5 hours per axis (1.12 Grms). Acoustic noise 56.4 to 75 dB. International Organization for Standardization (ISO) 7779: Bystander position operating to an ambient temperature of 86°F (30°C).
1-48 Catalyst 6500 Series Switches Installation Guide OL-5781-08 Chapter 1 Product Overview Catalyst 6509-NEB Switch Physical characteristics Dimensions (H x W x D) 33.3 x 17.2 x 18.1 in. (84.6 x 43.7 x 46.0 cm). Chassis requires 20 RU1. The Catalyst 6509-NEB switch chassis is designed to install in standard 19-inch equipment racks that meet ANSI/EIA 310-D, IEC 60297, and ETS 300-119 standards. Weight Chassis only: 55 lb (24.9 kg). Chassis fully configured with 1 supervisor engine, 8 switching modules, and 2 power supplies: 135 lb (61.2 kg). Airflow WS-C6509-NEB-FAN (Standard fan tray)—294 CFM Optional high-speed fan tray2—630 CFM NoteTo maintain proper air circulation through the Catalyst switch chassis, we recommend that you maintain a minimum 6-inch (15 cm) separation between a wall and the chassis air intake or a wall and the chassis air exhaust. You should also allow a minimum separation of 12 inches (30.5 cm) between the hot air exhaust on one chassis and the air intake on another chassis. Failure to maintain adequate air space can cause the chassis to overheat and the system to fail. On Catalyst chassis in which the airflow is from front to back, the chassis may be placed side-by-side. 1. RU = rack units. 2. Part of the WS-6509-NEB-UPGRD kit. Table 1-16 Catalyst 6509-NEB Switch Specifications (continued) Item Specification