Home > Cisco > Ethernet Switch > Cisco 6500e Manual

Cisco 6500e Manual

    Download as PDF Print this page Share this page

    Have a look at the manual Cisco 6500e Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 53 Cisco manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.

    Page
    of 454
    							1-39
    Catalyst 6500 Series Switches Installation Guide
    OL-5781-08
    Chapter 1      Installing the Switch
      Installing a Catalyst 6509-V-E Switch Chassis
    Figure 1-20 Installing a Catalyst 6509-V-E Switch Chassis in a Rack
    112-24 or 10-32 rack-mounting screws (10x)2Shelf bracket
    INPUT
    OKFA N
    OKOUTPUT
    FA IL
    o
    280388
    POWER SUPPLY 1
    POWER SUPPLY 2
    W
    S
    -S
    U
    P32
    -G
    E
    -3
    BSTA
    TUS
    SYSTEM
    ACTIVE
    PWR
     MG
    MT
    RES
    ETC
    A
    TA
    L
    Y
    S
    T
       6
    500
     S
    UP
    E
    R
    V
    ISO
    R
      
    E
    N
    G
    IN
    E
      32
    C
    O
    N
    S
    O
    L
    E
    E
    J
    E
    C
    TD
    IS
    K
     0P
    O
    R
    T 1
    P
    O
    R
    T
     2
    P
    O
    R
    T 3
    P
    O
    R
    T
     4P
    O
    R
    T 5
    P
    O
    R
    T
     6
    P
    O
    R
    T 7P
    O
    R
    T
     8P
    O
    R
    T 9
    U
    S
    B
     2
    .0
    LIN
    K
    LIN
    K
    LIN
    K
    LINK
    LIN
    K
    LINK
    LINK
    LINK
    LINK
    W
    S
    -S
    U
    P32
    -G
    E
    -3
    BSTA
    TUS
    SYSTEM
    ACTIVE
    PWR
     MG
    MT
    RES
    ETC
    A
    TA
    L
    Y
    S
    T
       6
    500
     S
    UP
    E
    R
    V
    ISO
    R
      
    E
    N
    G
    IN
    E
      32
    C
    O
    N
    S
    O
    L
    E
    E
    J
    E
    C
    TD
    IS
    K
     0P
    O
    R
    T 1
    P
    O
    R
    T
     2
    P
    O
    R
    T 3
    P
    O
    R
    T
     4P
    O
    R
    T 5
    P
    O
    R
    T
     6
    P
    O
    R
    T 7P
    O
    R
    T
     8P
    O
    R
    T
     9
    U
    S
    B
     2
    .0
    LIN
    K
    LIN
    K
    LIN
    K
    LINK
    LIN
    K
    LINK
    LINK
    LINK
    LINK
    WS-X6548-GE-TX
    STATUS
    48 PORT10/100/1000
    BASE-T GESWITCHING MODULE
    123456789101112
    131415161718192021222324
    252627282930313233343536
    373839404142434445464748PHONE
    1
         211
         1213
         1423
         2425
         2635
         3637
         3847
         48
    WS-X6548-GE-TX
    STATUS
    48 PORT10/100/1000
    BASE-T GESWITCHING MODULE
    123456789101112
    131415161718192021222324
    252627282930313233343536
    373839404142434445464748PHONE
    1
         211
         1213
         1423
         2425
         2635
         3637
         3847
         48WS-X6548-GE-TX
    STATUS
    48 PORT10/100/1000
    BASE-T GESWITCHING MODULE
    123456789101112
    131415161718192021222324
    252627282930313233343536
    373839404142434445464748PHONE
    1
         211
         1213
         1423
         2425
         2635
         3637
         3847
         48WS-X6548-GE-TX
    STATUS
    48 PORT10/100/1000
    BASE-T GESWITCHING MODULE
    123456789101112
    131415161718192021222324
    252627282930313233343536
    373839404142434445464748PHONE
    1
         211
         1213
         1423
         2425
         2635
         3637
         3847
         48WS-X6548-GE-TX
    STATUS
    48 PORT10/100/1000
    BASE-T GESWITCHING MODULE
    123456789101112
    131415161718192021222324
    252627282930313233343536
    373839404142434445464748PHONE
    1
         211
         1213
         1423
         2425
         2635
         3637
         3847
         48WS-X6548-GE-TX
    STATUS
    48 PORT10/100/1000
    BASE-T GESWITCHING MODULE
    123456789101112
    131415161718192021222324
    252627282930313233343536
    373839404142434445464748PHONE
    1
         211
         1213
         1423
         2425
         2635
         3637
         3847
         48WS-X6548-GE-TX
    STATUS
    48 PORT10/100/1000
    BASE-T GESWITCHING MODULE
    123456789101112
    131415161718192021222324
    252627282930313233343536
    373839404142434445464748PHONE
    1
         211
         1213
         1423
         2425
         2635
         3637
         3847
         48
    2
    1 
    						
    							1-40
    Catalyst 6500 Series Switches Installation Guide
    OL-5781-08
    Chapter 1      Installing the Switch
      Installing a Catalyst 6509-V-E Switch Chassis
    Installing the Cable Management System (Optional)
    The accessory kit for the Catalyst 6509-V-E switch chassis includes an optional cable management 
    system that is installed on the front of the switch chassis. This cable management system is only 
    available for the Catalyst 6509-V-E switch chassis. 
    NoteThe cable management system adds an additional 6.8 inches (17.3 cm) (measured to the outside of the 
    thumbscrews) to the overall depth of the chassis.
    To install the cable management system on the chassis, perform the following steps:
    Step 1Remove the cable management assembly from the packing material.
    Step 2Locate the bag containing the four 6-32 screws that accompanied the cable management assembly.
    Step 3Loosen the two captive screws on the inside of the cable management assembly and pivot the cable guide 
    assembly away from the attachment bracket. (See Figure 1-21.)
    Step 4Position the cable management assembly in front of the chassis, align the four screw holes in the 
    attachment bracket with the corresponding screw holes in the chassis, and secure the cable management 
    assembly in place with the four 6-32 screws. (See Figure 1-21.)
    Figure 1-21 Installing the Catalyst 6509-V-E Cable Management Assembly
    280372
    2
    1
    3 
    						
    							1-41
    Catalyst 6500 Series Switches Installation Guide
    OL-5781-08
    Chapter 1      Installing the Switch
      Installing a Catalyst 6509-V-E Switch Chassis
    Step 5Pivot the cable management assembly up on its hinges so that the back plate of the assembly is flush 
    against the chassis. Secure the cable management assembly in place to the front of the chassis with the 
    two captive installation screws. (See Figure 1-22.)
    Figure 1-22 Securing the Cable Management Assembly to the Front of the Chassis
    1Cable guide assembly26-32 screws (4x)
    3Attachment bracket
    1Captive installation screws (2x)
    1
    280373 
    						
    							1-42
    Catalyst 6500 Series Switches Installation Guide
    OL-5781-08
    Chapter 1      Installing the Switch
      Installing a Catalyst 6513 or Catalyst 6513-E Switch Chassis
    What is Next
    After installing the chassis in its location, complete the installation process by following these 
    procedures:
    Connecting the chassis to system ground. See “Establishing the System Ground” section on 
    page 1-52.
    Installing and connecting the power supplies to source power. Go to Chapter 4 for information on 
    how to install and cable power supplies.
    Connecting the network interface cables to the supervisor engine and modules. This may involve 
    installing transceivers before you attach the network interface cables. See “Attaching the Interface 
    Cables” section on page 1-61. 
    NoteIf you are going to use the cable management system to route the network interface cables, refer 
    to “Using the Catalyst 6509-V-E Cable Management System” section on page 1-78.
    Powering-up the chassis and verifying the installation. See “Verifying Switch Chassis Installation” 
    section on page 1-84.
    Optional Installation Kits
    There are no optional installation kits for the Catalyst 6509-V-E switch chassis.
    Installing a Catalyst 6513 or Catalyst 6513-E Switch Chassis
    This section provides a procedure for installing either a Catalyst 6513 or Catalyst 6513-E switch chassis 
    in a rack assembly and installing the optional cable guide assemblies. 
    Installation Accessory Kit
    The Catalyst 6513 and the Catalyst 6513-E switch chassis are designed to be installed in a standard 
    19-inch rack either open or enclosed. The chassis is shipped with the 19-inch rack-mount brackets 
    factory installed on the left-front and right-front of the chassis. Included in the accessory kit are 10-32 
    x 0.75-inch and 12-24 x 0.75-inch screws that are used to secure the chassis in the rack. 
    NoteDepending on the manufacturer, the rack posts might be prethreaded to accept either 10-32 or 12-24 
    screws. If the rack posts are not prethreaded, you must install 10-32 or 12-24 clip nuts or cage nuts to 
    secure the rack-mount screws. The clip nuts or the cage nuts are not included as part of the accessory kit 
    and must be obtained on your own. 
    						
    							1-43
    Catalyst 6500 Series Switches Installation Guide
    OL-5781-08
    Chapter 1      Installing the Switch
      Installing a Catalyst 6513 or Catalyst 6513-E Switch Chassis
    The accessory kit also contains the following chassis installation kits:
    A rack-mount shelf kit. The rack-mount shelf kit is used to support the weight of the chassis while 
    you secure the chassis L brackets to the rack enclosure.
    A stabilizer bracket kit. If you are not installing the Catalyst 6513 or Catalyst 6513-E switch in a 
    rack, you must install the stabilizer brackets to the bottom of the chassis. The stabilizer brackets 
    reduce the possibility that the freestanding switch chassis will tip over. 
    Also included in the accessory kit:
    Two optional cable guides—The two cable guides can be installed on the front left- and right-sides 
    of the chassis using the same sets of screws (either 10-32 or 12-24) that secure the chassis 
    rack-mount L brackets to the rack posts.
    Power supply blank panel—The power supply blank panel must be installed on an unused power 
    supply bay to maintain chassis airflow and EMI shielding.
    L Brackets on the Catalyst 6513 and Catalyst 6513-E Switch Chassis
    The Catalyst 6513 and the Catalyst 6513-E switch chassis are shipped with the two L brackets installed 
    on the front sides of the chassis. The L brackets are secured to the chassis with 14 M3 Phillips-head 
    countersunk screws (seven screws on each side) as shown in Figure 1-23. 
    NoteThe L brackets can also be reversed and installed on the rear of the chassis as an alternative method of 
    installation. 
    						
    							1-44
    Catalyst 6500 Series Switches Installation Guide
    OL-5781-08
    Chapter 1      Installing the Switch
      Installing a Catalyst 6513 or Catalyst 6513-E Switch Chassis
    Figure 1-23 L Brackets on the Catalyst 6513 Switch Chassis
    Installing the 3 RU Rack-Mount Shelf Kit
    The 3 RU rack-mount shelf kit is included as part of the accessory kit for the Catalyst 6513 and the 
    Catalyst 6513-E switch chassis. You need to install this kit first before you install the chassis in the rack. 
    The shelf kit supports the weight of the chassis while you install the chassis in the rack.
    The procedure for installing the shelf kit is located in the “Installing the 3 RU Rack-Mount Shelf Kit” 
    section on page 1-47. 1M4 Phillips-head countersunk screws (10x)2Rack-mount L brackets (2x)
    FA
    N
    S
    TA
    TU
    S
    8 PORT 
    GI
    GABI
    T E
    THERN
    ETWS-X6
    40
    81L
    IN
    KSTA
    TUS2
    3
    4
    5
    6
    7
    8L
    IN
    KLINKLIN
    KL
    INKL
    IN
    KLIN
    KL
    IN
    K
    2
    4
     
    P
    O
    R
    T 
    1
    0
    0
    F
    XW
    S
    -
    X
    6
    2
    2
    4ST
    AT
    U
    S
    2
    4
     
    P
    O
    R
    T 
    1
    0
    0
    F
    XW
    S
    -
    X
    6
    2
    2
    4S
    TAT
    U
    S
    2
    4
     P
    O
    R
    T 
    1
    0
    0
    F
    XW
    S
    -
    X
    6
    2
    2
    4S
    TAT
    U
    S
    2
    4
     
    P
    O
    R
    T 
    1
    0
    0
    F
    XW
    S
    -
    X
    6
    2
    2
    4S
    T
    AT
    U
    S
    1LI
    N
    K2LI
    N
    K3LI
    NK4LI
    N
    K5LI
    NK6LI
    NK7LINK8LI
    NK9LI
    N
    K1
    0LINK1
    1LI
    NK1
    2LI
    NK1
    3LI
    NK1
    4LI
    N
    K1
    5LI
    NK1
    6LI
    NK1
    7LIN
    K1
    8LI
    NK1
    9LIN
    K2
    0LI
    NK2
    1LINK2
    2LI
    NK2
    3LI
    N
    K2
    4LI
    N
    K1L
    INK2L
    I
    N
    K3L
    I
    N
    K4L
    I
    N
    K5L
    I
    N
    K6L
    I
    N
    K7L
    I
    N
    K8L
    I
    N
    K9L
    IN
    K1
    0L
    I
    N
    K1
    1L
    INK1
    2L
    I
    NK1
    3L
    I
    NK1
    4L
    I
    NK1
    5L
    INK1
    6L
    INK1
    7L
    INK1
    8L
    INK1
    9L
    INK2
    0L
    I
    NK2
    1L
    I
    NK2
    2L
    INK2
    3L
    INK2
    4L
    INK1L
    I
    N
    K2L
    I
    N
    K3L
    I
    N
    K4L
    I
    N
    K5L
    I
    N
    K6L
    I
    N
    K7L
    I
    N
    K8L
    I
    N
    K9L
    I
    N
    K10L
    I
    N
    K11L
    I
    N
    K12L
    I
    N
    K13L
    I
    N
    K14L
    I
    N
    K15L
    I
    N
    K16L
    I
    N
    K17L
    I
    N
    K18L
    I
    N
    K19L
    I
    N
    K20L
    I
    N
    K21L
    I
    N
    K22L
    I
    N
    K23L
    I
    N
    K24L
    I
    N
    K1L
    I
    N
    K2L
    I
    N
    K3L
    I
    N
    K4L
    I
    N
    K5L
    I
    N
    K6L
    I
    N
    K7L
    I
    N
    K8L
    I
    N
    K9L
    I
    N
    K1
    0L
    IN
    K1
    1L
    I
    N
    K1
    2L
    I
    N
    K1
    3L
    I
    N
    K1
    4L
    I
    N
    K1
    5L
    I
    N
    K1
    6L
    I
    N
    K1
    7L
    IN
    K1
    8L
    I
    N
    K1
    9L
    IN
    K2
    0L
    I
    N
    K2
    1L
    I
    N
    K2
    2L
    I
    N
    K2
    3L
    I
    N
    K2
    4L
    I
    N
    K
    1
    2
    3
    4
    5
    6
    7
    8
    9
    10
    11
    12
    13
    280389
    12 
    						
    							1-45
    Catalyst 6500 Series Switches Installation Guide
    OL-5781-08
    Chapter 1      Installing the Switch
      Installing a Catalyst 6513 or Catalyst 6513-E Switch Chassis
    Rack-Mounting the Chassis
    TipWe recommend that you have a third person to assist in this procedure.
    CautionFor easier installation, the chassis should be empty when you install it in the rack.
    WarningTwo people are required to lift the chassis. To prevent injury, keep your back straight and lift with your 
    legs, not your back. Statement 164
    To install the switch chassis in the equipment rack, follow these steps:
    Step 1With a person standing at each side of the chassis, grasp the chassis handle with one hand, and use the 
    other hand near the back of the chassis for balance. Slowly lift the chassis in unison. Avoid sudden twists 
    or moves to prevent injury.
    Step 2Position the chassis in the rack as follows:
    a.If the front of the chassis (front panel) is at the front of the rack, insert the rear of the chassis between 
    the mounting posts, resting the chassis on the shelf brackets, and then carefully slide the chassis into 
    the rack. 
    b.If the rear of the chassis is at the front of the rack, insert the front of the chassis between the 
    mounting posts, resting the chassis on the shelf brackets, and then carefully slide the chassis into the 
    rack. 
    Step 3Locate the rack post holes that align with the chassis L bracket holes. If the rack post holes are 
    prethreaded, determine if the threads are 10-32 or 12-24. If the rack post holes are unthreaded, install 
    eight or ten (four or five on each side) either 10-32 or 12-24 clip or cage nuts over the rack post holes to 
    accept the installation screws. 
    NoteClip nuts or cage nuts are not included as part of the accessory kit that comes with the chassis. 
    You must obtain them yourself.
    Step 4If you want to install one or both of the optional cable guide assemblies, position the cable guides so that 
    the cable guide mounting holes are aligned with rack-mount bracket holes and the rack post holes as 
    shown in Figure 1-24. 
    Step 5Install a minimum of ten (five on each side) 10-32 or 12-24 screws through the cable guide mounting 
    holes, rack-mount L bracket holes, rack post holes, and into the clip nuts to secure the cable guides and 
    the chassis to the rack post. Tighten the screws securely. (See Figure 1-24.)
    Step 6Use a tape measure and level to verify that the chassis is installed straight and level.
    NoteIf you are not rack-mounting the Catalyst 6513 or the Catalyst 6513-E switch and you are installing the 
    optional cable guide assemblies, you must obtain ten 12-24 or 10-32 nuts. Use the screws supplied in the 
    accessory kit and the nuts you obtained to attach the cable guide assembly to the L bracket. 
    						
    							1-46
    Catalyst 6500 Series Switches Installation Guide
    OL-5781-08
    Chapter 1      Installing the Switch
      Installing a Catalyst 6513 or Catalyst 6513-E Switch Chassis
    Figure 1-24 Installing the Catalyst6513 Switch Chassis in the Rack
    What is Next
    After installing the chassis in its location, complete the installation process by following these 
    procedures:
    Connecting the chassis to system ground. See “Establishing the System Ground” section on 
    page 1-52.
    Installing and connecting the power supplies to source power. Go to Chapter 4 for information on 
    how to install and cable power supplies.
    Connecting the network interface cables to the supervisor engine and modules. This may involve 
    installing transceivers before you attach the network interface cables. See “Attaching the Interface 
    Cables” section on page 1-61.
    Powering-up the chassis and verifying the installation. See “Verifying Switch Chassis Installation” 
    section on page 1-84.
    FA N
    STATUS
    8 PORT GIGABIT ETHERNETW
    S-X64081L
    IN
    KSTATUS2
    34
    5
    6
    7
    8L
    IN
    KL
    IN
    KLIN
    KLIN
    KL
    IN
    KLIN
    KLIN
    K8 P
    ORT GIGABIT ETHERNETWS-X64081LIN
    KSTATUS2
    3
    4
    56
    7
    8LIN
    KLIN
    KL
    IN
    KL
    IN
    KLIN
    KLIN
    KLIN
    K8 PORT GIGABIT ETHERNETWS-X64081L
    IN
    KSTATUS2
    34
    5
    6
    7
    8L
    IN
    KLIN
    KL
    IN
    KLIN
    KL
    IN
    KLIN
    KLIN
    K
    2
    4
     
    P
    O
    R
    T
     1
    0
    0
    F
    XW
    S
    -
    X
    6
    2
    2
    4S
    T
    A
    T
    U
    S
    2
    4
     P
    O
    R
    T
     1
    0
    0
    F
    XW
    S
    -
    X
    6
    2
    2
    4S
    T
    A
    T
    U
    S
    2
    4
     
    P
    O
    R
    T
     
    1
    0
    0
    F
    XW
    S
    -
    X
    6
    2
    2
    4S
    T
    A
    T
    U
    S
    2
    4
     
    P
    O
    R
    T
     
    1
    0
    0
    F
    XW
    S
    -
    X
    6
    2
    2
    4S
    T
    A
    T
    U
    S
    1LINK2LINK3LINK4LINK5LINK6LINK7LINK8LINK9LINK1
    0LINK1
    1LINK1
    2LINK1
    3LINK1
    4LINK1
    5LINK1
    6LINK1
    7LINK1
    8LINK1
    9LINK2
    0LINK2
    1LINK2
    2LINK2
    3LINK2
    4LINK1L
    I
    N
    K2L
    I
    N
    K3L
    I
    N
    K4L
    I
    N
    K5L
    I
    N
    K6L
    I
    N
    K7L
    I
    N
    K8L
    I
    N
    K9L
    I
    N
    K1
    0L
    I
    N
    K1
    1L
    I
    N
    K1
    2L
    I
    N
    K1
    3L
    I
    N
    K1
    4L
    I
    N
    K1
    5L
    I
    N
    K1
    6L
    I
    N
    K1
    7L
    I
    N
    K1
    8L
    I
    N
    K1
    9L
    I
    N
    K2
    0L
    I
    N
    K2
    1L
    I
    N
    K2
    2L
    I
    N
    K2
    3L
    I
    N
    K2
    4L
    I
    N
    K1L
    I
    N
    K2L
    I
    N
    K3L
    I
    N
    K4L
    I
    N
    K5L
    I
    N
    K6L
    I
    N
    K7L
    I
    N
    K8L
    I
    N
    K9L
    I
    N
    K10L
    I
    N
    K11L
    I
    N
    K12L
    I
    N
    K13L
    IN
    K14L
    I
    N
    K15L
    I
    N
    K16L
    I
    N
    K17L
    I
    N
    K18L
    I
    N
    K19L
    I
    N
    K20L
    I
    N
    K21L
    I
    N
    K22L
    I
    N
    K23L
    I
    N
    K24L
    I
    N
    K1L
    I
    N
    K2L
    I
    N
    K3L
    I
    N
    K4L
    I
    N
    K5L
    I
    N
    K6L
    I
    N
    K7L
    I
    N
    K8L
    IN
    K9L
    IN
    K1
    0L
    I
    N
    K1
    1L
    I
    N
    K1
    2L
    I
    N
    K1
    3L
    IN
    K1
    4L
    I
    N
    K1
    5L
    I
    N
    K1
    6L
    I
    N
    K1
    7L
    IN
    K1
    8L
    IN
    K1
    9L
    I
    N
    K2
    0L
    I
    N
    K2
    1L
    I
    N
    K2
    2L
    IN
    K2
    3L
    I
    N
    K2
    4L
    I
    N
    K
    SUPERVISOR2 WS-X6K-SUP2-2GESTATUSSYSTEMCONSOLEPWR MGMTRESETCONSOLECONSOLE
    PORT
    MODEPCMCIAEJECTPORT 1PORT 2Switch    Load   
    100%
    1%LINK
    LINKSUPERVISOR2 WS-X6K-SUP2-2GESTATUSSYSTEMCONSOLEPWR MGMTRESETCONSOLECONSOLE
    PORT
    M
    OD
    EPCMCIAEJECTPORT 1PORT 2Switch    Load   
    100%
    1%LINK
    LINK
    1
    2
    3
    4
    5
    6
    7
    8
    9
    10
    11
    12
    13
    48125
    12 x 24
    or
    10 x 32
    (10x)
    Shelf
    bracket
    Cable guide L-bracket 
    						
    							1-47
    Catalyst 6500 Series Switches Installation Guide
    OL-5781-08
    Chapter 1      Installing the Switch
      Generic Installation Procedures
    Optional Installation Kits
    An optional stabilizer bracket installation kit is included in the accessory kit for the Catalyst 6513 and 
    the Catalyst 6513-E switch chassis. This kit contains the parts necessary to install two brackets on the 
    bottom of the chassis to provide additional stability for the chassis when the chassis is not rack mounted 
    allowing the chassis to placed on a shelf or a table. To install the stabilizer brackets, go to “Installing the 
    Stabilizer Bracket Kit” section on page 1-50
    A center rack-mount kit for 23-inch, telco-style racks is available as an option for the Catalyst 6513 and 
    the Catalyst 6513-E switch chassis. The center rack-mount kit is not included in the accessory kit, but is 
    available as a separately orderable item (p/n WS-6513-RACK-MNT=). Installation instructions are 
    included with the kit.
    Generic Installation Procedures
    This section provides procedures covering how to install three installation kits that are included in 
    multiple Catalyst 6500 series chassis accessory kits. The following procedures are provided in this 
    section:
    Installing the 3 RU Rack-Mount Shelf Kit, page 1-47
    Installing the Rubber Feet Kit, page 1-50
    Installing the Stabilizer Bracket Kit, page 1-50
    Installing the 3 RU Rack-Mount Shelf Kit
    This section describes how to install the 3 RU rack-mount shelf kit. The kit contains shelf brackets, a 
    crossbar bracket, and screws. The shelf brackets attach directly to the rack and help support the weight 
    of the chassis while you secure the L brackets to the rack enclosure. The rack-mount shelf kit is shipped 
    as part of the Catalyst 6500 series switch accessory kit with the following chassis:
    Catalyst 6506 and Catalyst 6506-E
    Catalyst 6509 and Catalyst 6509-E
    Catalyst 6509-NEB and Catalyst 6509-NEB-A
    Catalyst 6509-V-E
    Catalyst 6513 and Catalyst 6513-E
    Ta b l e 1 - 3 lists and describes the contents of the rack-mount shelf kit.
    Table 1-3 Rack-Mount Kit Contents and Description
    Part Quantity Description
    Rack-mount shelf bracket 2 Attaches to the rack posts to form a shelf for the switch 
    chassis to rest on.
    Crossbar bracket 1 Attaches between the two side rack-mount brackets to 
    secure them together. 
    12-24 x 0.75-inches 
    Phillips binder-head screw6 Secures the brackets (three for each bracket) to a rack 
    that requires 12-24 screws. 
    						
    							1-48
    Catalyst 6500 Series Switches Installation Guide
    OL-5781-08
    Chapter 1      Installing the Switch
      Generic Installation Procedures
    NoteThis rack-mounting kit is not suitable for use with racks that have obstructions (such as power strips) 
    because the obstructions could impair access to switch field-replaceable units (FRUs).
    Required Tools
    These tools and equipment are required to install the rack-mount shelf kit:
    Number 1 and number 2 Phillips screwdrivers
    3/16-inch flat-blade screwdriver 
    Tape measure and level
    Installing the Shelf Brackets and Crossbar Bracket
    NoteOn many older equipment racks, the rack posts are prethreaded to accept either 10-32 or 12-24 screws. 
    Newer rack enclosure posts might not be prethreaded. These rack enclosure posts require that you install 
    10-32 or 12-24 clip nuts or cage nuts to secure the rack-mount screws. The clip nuts or the cage nuts are 
    not included as part of the accessory kit and must be obtained on your own.
    To install the shelf bracket and crossbar bracket, follow these steps:
    Step 1Position one of the two shelf brackets in the rack as shown in Figure 1-25.
    Step 2Secure the shelf bracket to the rack by using three 12-24 x 3/4-inch or 10-32 x 3/4-inch screws.
    Step 3Repeat Steps 1 and 2 for the second shelf bracket. Make sure that the second shelf bracket is level with 
    the first bracket.
    Step 4Attach the crossbar bracket to the back of the shelf brackets using two M3 screws as shown in 
    Figure 1-26. 10-32 x 0.75-inches 
    Phillips binder-head screw6 Secures the brackets (three for each bracket) to a rack 
    that requires 10-32 screws.
    M3 x 8 mm Phillips 
    pan-head screw2 Secures the crossbar bracket to the rack-mount side 
    brackets.
    Table 1-3 Rack-Mount Kit Contents and Description (continued)
    Part Quantity Description 
    						
    All Cisco manuals Comments (0)