1-25 Catalyst 6500 Series Switches Installation Guide OL-5781-08 Chapter 1 Preparing for Installation Site Preparation Checklist Table 1-4 Site Planning Checklist Task No. Planning Activity Verified By Time Date 1 Space evaluation: Space and layout Floor covering Impact and vibration Lighting Maintenance access 2 Environmental evaluation: Ambient temperature Humidity Altitude Atmospheric contamination Airflow 3 Power evaluation: Input power type Power receptacles (Depends on power supply)1 Receptacle proximity to the equipment Dedicated (separate) circuits for redundant power supplies UPS for power failures2 DC systems: Proper gauge wire and lugs 1. Verify that each power supply installed in the chassis has a dedicated AC source or DC source circuit. 2. Refer to the power supply’s kVA rating as a sizing criteria in determining the output required by the UPS. The power supply’s kVA rating value is listed in the specifications table for each power supply in Appendix A. 4 Grounding evaluation: Circuit breaker size CO ground (AC- and DC-powered systems) 5 Cable and interface equipment evaluation: Cable type Connector type Cable distance limitations Interface equipment (transceivers) 6 EMI evaluation: Distance limitations for signaling Site wiring RFI levels
1-26 Catalyst 6500 Series Switches Installation Guide OL-5781-08 Chapter 1 Preparing for Installation Site Preparation Checklist
CH A P T E R 1-1 Catalyst 6500 Series Switches Installation Guide OL-5781-08 1 Installing the Switch NoteIn this publication, the term Catalyst 6500 series refers only to the switch chassis listed in Chapter 1. The Catalyst 6000 series switches (Catalyst 6006 and Catalyst 6009 switches) are described in a separate publication, the Catalyst 6000 Series Switch Installation Guide. This chapter describes how to install a Catalyst 6500 series switch. The chapter is divided into sections that cover installing the different Catalyst 6500 series chassis. Pointers within the overall chassis installation procedures point to separate installation procedures that cover installing various components and assemblies. The process of installing the switch can be broken down into a series of tasks. These tasks are listed in Ta b l e 1 - 1. Table 1-1 Catalyst 6500 Series Switch Installation Process Task Description Unpacking the switch Remove the switch from the packaging materials. NoteWe recommend that you save the packaging material for use later if you need to move the chassis. Installing the switch All Catalyst 6500 series chassis can be rack-mounted. Some chassis offer the option of installation as a freestanding unit through the use of rubber feet or stabilizer brackets. Connecting the chassis to system groundConstruct and attach a system ground wire from the building (earth) ground to the system ground point on the chassis. Installing and cabling the power supply or suppliesNormally, one power supply is shipped installed in the chassis. The second power supply, if part of the switch configuration, is shipped separately. You now install the second power supply and connect the power supplies to source power, either AC or DC. Cabling the supervisor engine and modules to the networkThe various ports on the supervisor engine and on the modules that are installed in the chassis must be connected to the network. This process can involve only attaching a network interface cable to the module port, or it can include the installation of a transceiver of some type in the supervisor engine or module port, and then attaching the network interface cable to the transceiver. Powering up the chassis After completing the network cabling and making sure that system ground is connected, the power supplies can be turned on. The system powers up and runs through a set of built-in diagnostics.
1-2 Catalyst 6500 Series Switches Installation Guide OL-5781-08 Chapter 1 Installing the Switch The chapter contains the following sections: Rack-Mounting Guidelines, page 1-3 Unpacking the Switch, page 1-5 Chassis Installation Kits and Cable Guides, page 1-5 Installing a Catalyst 6503 or Catalyst6503-E Switch Chassis, page 1-8 Installing a Catalyst 6504-E Switch Chassis, page 1-12 Installing a Catalyst 6506 or Catalyst 6506-E Switch Chassis, page 1-17 Installing a Catalyst 6509 or Catalyst6509-E Switch Chassis, page 1-21 Installing a Catalyst 6509-NEB or Catalyst6509-NEB-A Switch Chassis, page 1-26 Installing a Catalyst 6509-V-E Switch Chassis, page 1-36 Installing a Catalyst 6513 or Catalyst 6513-E Switch Chassis, page 1-42 Generic Installation Procedures, page 1-47 Establishing the System Ground, page 1-52 Installing the Power Supplies in the Switch Chassis, page 1-61 Attaching the Interface Cables, page 1-61 Verifying Switch Chassis Installation, page 1-84 WarningClass 1 laser product. Statement 1008 WarningThis unit is intended for installation in restricted access areas. A restricted access area can be accessed only through the use of a special tool, lock and key, or other means of security. Statement 1017 WarningOnly trained and qualified personnel should be allowed to install, replace, or service this equipment. Statement 1030 WarningUltimate disposal of this product should be handled according to all national laws and regulations. Statement 1040 WarningThis equipment must be installed and maintained by service personnel as defined by AS/NZS 3260. Incorrectly connecting this equipment to a general-purpose outlet could be hazardous. The telecommunications lines must be disconnected 1) before unplugging the main power connector or 2) while the housing is open, or both. Statement 1043
1-3 Catalyst 6500 Series Switches Installation Guide OL-5781-08 Chapter 1 Installing the Switch Rack-Mounting Guidelines WarningThis product requires short-circuit (overcurrent) protection, to be provided as part of the building installation. Install only in accordance with national and local wiring regulations. Statement 1045 WarningDuring this procedure, wear grounding wrist straps to avoid ESD damage to the card. Do not directly touch the backplane with your hand or any metal tool, or you could shock yourself. Statement 94 NoteIf you are installing a freestanding (not rack-mounted) Catalyst 6509-NEB, Catalyst 6513, or Catalyst 6513-E switch, you must install the stabilizer bracket kit, which is included as part of the accessory kit for these two switch chassis. Before starting the installation procedures in this chapter, see the “Site Preparation Checklist” section on page 1-24 to verify that all site planning activities were completed. Rack-Mounting Guidelines The Catalyst 6500 series switches are designed to be installed in both open and enclosed racks. Before rack-mounting the switch, ensure that the equipment rack complies with the following guidelines: The width of the rack, measured between the two front-mounting strips or rails, must be 17.75 inches (45.09 cm). The depth of the rack, measured between the front- and rear-mounting strips, must be at least 19.25 inches (48.9 cm). NoteAll of the Catalyst 6500 series switch chassis are designed to install in standard 19-inch racks. The rack must have sufficient vertical clearance to insert the chassis. These are the chassis heights: Catalyst Switch Chassis Height 6503 7 inches 17.8 cm 4 RU 6503-E 7 inches 17.8 cm 4 RU 6504-E 8.7 inches 22.1 cm 5 RU 6506 20.1 inches 51.1 cm 12 RU 6506-E 19.2 inches 48.8 cm 11 RU 6509 25.2 inches 64.0 cm 15 RU 6509-E 24.5 inches 62.2 cm 14 RU 6509-NEB 33.3 inches 84.6 cm 20 RU 6509-NEB-A 36.65 inches 93.1 cm 21 RU 6509-V-E 36.65 inches 93.1 cm 21 RU 6513 33.3 inches 84.6 cm 20 RU 6513-E 33.3 inches 84.6 cm 20 RU
1-4 Catalyst 6500 Series Switches Installation Guide OL-5781-08 Chapter 1 Installing the Switch Rack-Mounting Guidelines NoteChassis height is sometimes measured in rack units (RU or just U) where 1 RU or 1 U equals 1.75 in (44.45 mm). A typical server rack is 42 RU or 42 U in height. CautionIf the rack is on wheels, ensure that the brakes are engaged and that the rack is stabilized. NoteTo maintain proper air circulation through the Catalyst switch chassis, we recommend that you maintain a minimum 6-inch (15 cm) separation between a wall and the chassis air intake or a wall and the chassis air exhaust. You should also allow a minimum separation of 12 inches (30.5 cm) between the hot air exhaust on one chassis and the air intake on another chassis. Failure to maintain adequate air space can cause the chassis to overheat and the system to fail. On Catalyst switch chassis in which the airflow is from front to back, the chassis may be placed side-by-side. WarningTo prevent bodily injury when mounting or servicing this unit in a rack, you must take special precautions to ensure that the system remains stable. The following guidelines are provided to ensure your safety: This unit should be mounted at the bottom of the rack if it is the only unit in the rack. When mounting this unit in a partially filled rack, load the rack from the bottom to the top with the heaviest component at the bottom of the rack. If the rack is provided with stabilizing devices, install the stabilizers before mounting or servicing the unit in the rack. Statement 1006
1-5 Catalyst 6500 Series Switches Installation Guide OL-5781-08 Chapter 1 Installing the Switch Unpacking the Switch Unpacking the Switch TipDo not discard the shipping container when you unpack the switch. Flatten the shipping cartons and store them with the pallet. You will need these containers if you need to move or ship the switch in the future. Repacking instructions are provided in Appendix A, “Repacking the Switch.” To check the contents of the shipping container, perform the following: Check the contents of the accessory kit. Verify that you received all listed equipment, which should include the following: –Optional equipment that you ordered, such as network interface cables, transceivers, or special connectors Check the modules in each slot. Ensure that the configuration matches the packing list and that all of the specified interfaces are included. Blank power supply covers are shipped as part of the accessory kit. They are not installed on the chassis. NoteThe Catalyst 6503-E and the Catalyst 6504-E switch chassis are shipped with a shipping bracket installed across the front of the chassis slots. Do not remove the shipping bracket at this time; remove the shipping bracket after you have installed the chassis in the rack. Chassis Installation Kits and Cable Guides Each Catalyst 6500 series chassis ships with an accessory kit. Shipped as part of the accessory kit are chassis installation kits and cable guides. The chassis installation kits and cable guide contents vary between chassis. Installation kits and cable guides for each Catalyst 6500 series chassis are listed in Ta b l e 1 - 2. Table 1-2 Chassis Installation Kits and Cable Guides Chassis Installation Kits and Cable Guides Catalyst 6503 and Catalyst 6503-E Standard 19-inch rack-mount brackets (factory-installed on the chassis). Associated rack-mounting hardware is included in the accessory kit. Two 3-slot cable management guides are included in the accessory kit. Catalyst 6504-E Standard 19-inch L brackets (factory-installed on the chassis). Associated rack-mounting hardware is included in the accessory kit. Two 4-slot cable management guides are included in the accessory kit.
1-6 Catalyst 6500 Series Switches Installation Guide OL-5781-08 Chapter 1 Installing the Switch Chassis Installation Kits and Cable Guides Catalyst 6506 and Catalyst 6506-EStandard 19-inch rack-mount L brackets (factory-installed on the chassis). Associated rack-mounting hardware is included in the accessory kit. 3 RU rack-mount shelf kit is included in the accessory kit. Two 6-slot cable management guides are included in the accessory kit. Catalyst 6506-E only—Rubber feet installation kit is included in the accessory kit. (The kit is used when installing the chassis as a freestanding unit on a table or shelf.) NoteAn optional center rack-mount kit for 23-inch, telco-style racks is available for both of these chassis. The kit is not included as part of the standard accessory kit, but is available as a separately orderable item (WS-C6597=). Installation instructions are included with the kit. Catalyst 6509 and Catalyst 6509-E Standard 19-inch rack-mount L brackets (factory-installed on the chassis). Associated rack-mounting hardware is included in the accessory kit. 3 RU rack-mount shelf kit is included in the accessory kit. Two 9-slot cable management guides are included in the accessory kit. Catalyst 6509-E only—Rubber feet installation kit is included in the accessory kit. (The kit is used when installing the chassis as a freestanding unit on a table or shelf.) NoteAn optional center rack-mount kit for 23-inch, telco-style racks is available for both of these chassis. The kit is not included as part of the standard accessory kit, but is available as a separately orderable item (WS-C6597=). Installation instructions are included with the kit. Catalyst 6509-NEB Standard 19-inch rack-mount L brackets (factory-installed on the chassis). Associated rack-mounting hardware is included in the accessory kit. 3 RU rack-mount shelf kit is included in the accessory kit. Stabilizer bracket installation kit is included in the accessory kit. (The kit is required when installing the chassis as a freestanding unit.) One cable management guide is included in the accessory kit. Table 1-2 Chassis Installation Kits and Cable Guides (continued) Chassis Installation Kits and Cable Guides
1-7 Catalyst 6500 Series Switches Installation Guide OL-5781-08 Chapter 1 Installing the Switch Chassis Installation Kits and Cable Guides Catalyst 6509-NEB-AStandard 19-inch rack-mount L brackets (factory-installed on the chassis). Associated rack-mounting hardware is included in the accessory kit. 3 RU rack-mount shelf kit is included in the accessory kit. One 9-slot vertical chassis cable management system is included in the accessory kit. Catalyst 6509-V-E Standard 19-inch rack-mount L brackets (factory-installed on the chassis). Associated rack-mounting hardware is included in the accessory kit. 3 RU rack-mount shelf kit is included in the accessory kit. One cable management system is included in the accessory kit. Catalyst 6513 or Catalyst 6513-E Standard 19-inch rack-mount L brackets (factory-installed on the chassis). Associated rack-mounting hardware is included in the accessory kit. 3 RU rack-mount shelf kit is included in the accessory kit. Stabilizer bracket installation kit is included in the accessory kit. (The kit is required when installing the chassis as a freestanding unit.) Two 13-slot cable management guides are included in the accessory kit. NoteAn optional center rack-mount kit for 23-inch, telco-style racks is available for this chassis. The kit is not included as part of the standard accessory kit, but is available as a separately orderable item (WS-6513-RACK-MNT=). Installation instructions are included with the kit. Table 1-2 Chassis Installation Kits and Cable Guides (continued) Chassis Installation Kits and Cable Guides
1-8 Catalyst 6500 Series Switches Installation Guide OL-5781-08 Chapter 1 Installing the Switch Installing a Catalyst 6503 or Catalyst 6503-E Switch Chassis Installing a Catalyst 6503 or Catalyst 6503-E Switch Chassis This section provides procedures for installing either a Catalyst 6503 or a Catalyst 6503-E switch chassis in a rack assembly and installing the optional cable guide assemblies. Installation Accessory Kit The Catalyst 6503 and Catalyst 6503-E switch chassis are both designed to be installed in a standard 19-inch rack, either open or enclosed, using 19-inch rack-mount brackets that are factory installed on the left-front and right-front of the chassis. Included in the installation accessory kit are both 10-32 x 0.75-inch and 12-24 x 0.75-inch screws that are used to secure the chassis in the rack. NoteDepending on the manufacturer, the rack posts might be prethreaded to accept either 10-32 or 12-24 screws. If the rack posts are not prethreaded, you must install 10-32 or 12-24 clip nuts or cage nuts to secure the rack-mount screws. The clip nuts or the cage nuts are not included as part of the accessory kit and must be obtained on your own. Also included in the accessory kit are two optional cable guides. The two cable guides are installed on the front left- and right-sides of the chassis using the same sets of screws (either 10-32 or 12-24) that secure the chassis rack-mount brackets to the rack posts. Rack-Mount Brackets on the Catalyst6503 and the Catalyst 6503-E Switch Chassis The Catalyst 6503 and the Catalyst 6503-E switch chassis are shipped with the two rack-mount brackets factory-installed on the front sides of the chassis. The rack-mount brackets are secured to the chassis with eight M3 Phillips-head countersunk screws (four screws on each side) as shown in Figure 1-1. NoteThe Catalyst 6503-E chassis has a chassis shipping bracket installed across the module slots. The bracket has been removed for clarity in Figure 1-1. The Catalyst 6503 switch chassis does not have this shipping bracket. NoteThe rack-mount brackets can also be reversed and installed on the rear of the chassis as an alternative method of installation.