1-9 Catalyst 6500 Series Switches Installation Guide OL-5781-08 Chapter 1 Installing the Switch Installing a Catalyst 6503 or Catalyst 6503-E Switch Chassis Figure 1-1 Rack-Mount Brackets on the Catalyst 6503 and the Catalyst 6503-E Switch Chassis Rack-Mounting the Chassis NoteThe chassis are designed to be mounted in equipment racks that meet ANSI/EIA 310-D and ETS 300-119 standards. WarningTwo people are required to lift the chassis. To prevent injury, keep your back straight and lift with your legs, not your back. Statement 164 TipWe recommend that you have a third person to assist in this procedure. To install the switch chassis into the equipment rack, follow these steps: Step 1Determine the positioning of the chassis in the rack enclosure. Identify the rack post holes that will be used. If the rack post holes are prethreaded, determine if the threads are 10-32 or 12-24. If the rack post holes are unthreaded, install either 10-32 or 12-24 clip or cage nuts over the holes to accept the installation screws. NoteClip or cage nuts are not included as part of the accessory kit that comes with the chassis. You must obtain them yourself. Step 2If you are installing a Catalyst 6503-E switch chassis, you must remove the chassis shipping bracket before you install the chassis in the rack. Perform the following substeps: a.Loosen and remove the four M5 screws that secure the chassis shipping bracket to the chassis rack mount brackets. (See Figure 1-2.) b.Lift up slightly on the shipping bracket to disengage the two bracket hooks from the rack-mount brackets. c.Remove the shipping bracket and save it. You must reinstall the shipping bracket if you relocate the chassis. SUPERVISOR2 WS-X6K-SUP2-2GESTAT USSYSTEMCON SO LEPW R M G M TR ESETCONSOLECONSOLE PORT MODEPCMCIA EJECTPORT 1PORT 2Switch Load 100% 1% L I N K L IN KOSM-4OC12 POS-SI 4 PORT OC-12 POS SM IRSTATUS 1 1 2 23 3 4 4RESET LINK LINKLINK LINK CARRIER ALARM CARRIER ALARM CARRIER ALARM CARRIER ALARM ACTIVE TX RX TX PORT 1 RX ACTIVE TX RX TX PORT 2 RXACTIVE TX RX TX PORT 3 RXACTIVE TX RX TX PORT4 RX OSM-4OC12 POS-SI 4 PORT OC-12 POS SM IR STATUS 1 1 2 23 3 4 4RESET LINK LINKLINK LINK CARRIER ALARM CARRIER ALARM CARRIER ALARM CARRIER ALARM ACTIVE TX RX TX PORT 1 RX ACTIVE TX RX TX PORT 2 RXACTIVE TX RX TX PORT 3 RXACTIVE TX RX TX PORT4 RX 63180
1-10 Catalyst 6500 Series Switches Installation Guide OL-5781-08 Chapter 1 Installing the Switch Installing a Catalyst 6503 or Catalyst 6503-E Switch Chassis Figure 1-2 Removing the Catalyst 6503-E Chassis Shipping Bracket Step 3 With a person standing at each side of the chassis, grasp the chassis handle with one hand, and use the other hand near the back of the chassis for balance. Slowly lift the chassis in unison. Avoid sudden twists or moves to prevent injury. TipHave a third person install the rack-mount screws while two people support the chassis in the rack enclosure. Step 4Align the mounting holes in the rack-mount bracket with the mounting holes in the equipment rack. Step 5If you want to install one or both of the optional cable guides, position the cable guide so that the cable guide mounting holes are aligned with rack-mount holes and the rack post holes. (See Figure 1-3.) Step 6Install a minimum of eight 10-32 or 12-24 screws (four on each side) through the cable guide mounting holes, rack-mount bracket holes, rack post holes, and into the clip nuts to secure the cable guides and the chassis to the rack post. (See Figure 1-3.) Step 7Use a tape measure or level to verify that the chassis is installed straight and level.1Chassis shipping bracket2M5 Phillips-head screws (4x) 280384 W S- X 65 16 -GE - T X 16 P OR T 100 0 B A SE -T GE 12345678910111213141516 L INK ST AT US L IN KL INKL INKLI NKLIN KLI NKLI N KL INKL IN KL INKL INKL IN KL IN KLI N KLIN K CA TA LY S T 650 0 SU P ER V IS O R ENGINE 3 2C ONS OLE D ISK 0PO RT 1 PO RT 2 PO RT 3 PO RT 4 PO RT 5 PO RT 6 PO RT 7 PO RT 8 W S-S U P3 2- GE -3B EJECT PO RT 9 CA TA LY ST 6 50 0 SU P ER V IS O R E NGINE 3 2C ONS OL E D ISK 0PO RT 1 PO RT 2 PO RT 3 PO RT 4 PO RT 5 PO RT 6 PO RT 7 PO RT 8 W S- S U P3 2- GE - 3B EJECT PO RT 9 CA UTIONTHIS B RAC KE T IS FOR SH IP PI N G PU RPOS ES ONLY . YO U MU ST RE MOV E THIS BR AC KE T BE FORE SY ST E M INS T AL LA TI ON AND US E. DO NOT D ISCAR D THI S BR ACK ET . THIS B RAC KE T MUS T BE REP LA CE D ON THE CHASS IS FOR FUTURE SH I PME NTS .4 7 -1 95 2 2- 01 REV A0 1 2
1-11 Catalyst 6500 Series Switches Installation Guide OL-5781-08 Chapter 1 Installing the Switch Installing a Catalyst 6503 or Catalyst 6503-E Switch Chassis Figure 1-3 Installing a Catalyst 6503 or Catalyst 6503-E Switch Chassis in a Rack What is Next After installing the chassis in its location, complete the installation process by following these procedures: Connecting the chassis to system ground. See “Establishing the System Ground” section on page 1-52. Installing and connecting the Power Entry Modules (PEMs) and the power supplies to source power. Go to Chapter 4 for information on how to install and cable the PEMs and the power supplies. Connecting the network interface cables to the supervisor engine and modules. This may involve installing transceivers before you attach the network interface cables. See “Attaching the Interface Cables” section on page 1-61. Powering-up the chassis and verifying the installation. See “Verifying Switch Chassis Installation” section on page 1-84. Optional Installation Kits There are no optional installation kits available for either the Catalyst 6503 or the Catalyst 6503-E switch chassis. SUPERVISOR2 WS-X6K-SUP2-2GESTA TUSS YSTE MCO NSO LEPW R M GM TRES ETCONSOLECONSOLE PORT MODEPCMCIA EJECTPORT 1PORT 2Switch Load 100% 1% L I N K L IN KOSM-4OC12 POS-SI 4 PORT OC-12 POS SM IRSTATUS 1 1 2 23 3 4 4RESET LINK LINKLINK LINK CARRIER ALARM CARRIER ALARM CARRIER ALARM CARRIER ALARM ACTIVE TX RX TX PORT 1 RX ACTIVE TX RX TX PORT 2 RXACTIVE TX RX TX PORT 3 RXACTIVE TX RX TX PORT4 RX OSM-4OC12 POS-SI 4 PORT OC-12 POS SM IR STATUS 1 1 2 23 3 4 4RESET LINK LINKLINK LINK CARRIER ALARM CARRIER ALARM CARRIER ALARM CARRIER ALARM ACTIVE TX RX TX PORT 1 RX ACTIVE TX RX TX PORT 2 RXACTIVE TX RX TX PORT 3 RXACTIVE TX RX TX PORT4 RX 63181
1-12 Catalyst 6500 Series Switches Installation Guide OL-5781-08 Chapter 1 Installing the Switch Installing a Catalyst 6504-E Switch Chassis Installing a Catalyst 6504-E Switch Chassis This section provides procedures for installing a Catalyst 6504-E switch chassis in a rack assembly and installing the optional cable guide assemblies. Installation Accessory Kit The Catalyst 6504-E switch chassis is designed to be installed in a standard 19-inch rack, either open or enclosed. The chassis is shipped with the 19-inch rack-mount L brackets factory installed on the left-front and right-front of the chassis. Included in the accessory kit are both 10-32 x 0.75-inch and 12-24 x 0.75-inch screws that are used to secure the chassis in the rack. NoteDepending on the manufacturer, the rack posts might be prethreaded to accept either 10-32 or 12-24 screws. If the rack posts are not prethreaded, you must install 10-32 or 12-24 clip nuts or cage nuts to secure the rack-mount screws. The clip nuts or the cage nuts are not included as part of the accessory kit and must be obtained on your own. Also included in the accessory kit are two optional cable guides. The two cable guides are installed on the front left- and right-side of the chassis using the same sets of screws (10-32 or 12-24) that secure the chassis rack-mount L brackets to the rack posts. L Brackets on the Catalyst 6504-E Switch Chassis The Catalyst 6504-E switch chassis is shipped with the two L brackets installed on the front sides of the chassis. The L brackets are secured to the chassis with six M4 Phillips-head countersunk screws (three screws on each side) as shown in Figure 1-4. NoteThe Catalyst 6504-E chassis has a chassis shipping bracket installed across the module slots. The bracket has been removed in Figure 1-4 for clarity. NoteThe L brackets can also be reversed and installed on the rear of the chassis as an alternative method of installation.
1-13 Catalyst 6500 Series Switches Installation Guide OL-5781-08 Chapter 1 Installing the Switch Installing a Catalyst 6504-E Switch Chassis Figure 1-4 L Brackets on the Catalyst 6504-E Switch Chassis Rack-Mounting the Chassis NoteThe chassis are designed to be mounted in equipment racks that meet ANSI/EIA 310-D and ETS 300-119 standards. WarningTwo people are required to lift the chassis. To prevent injury, keep your back straight and lift with your legs, not your back. Statement 164 TipWe recommend that you have a third person to assist in this procedure. To install the switch chassis into the equipment rack, follow these steps: Step 1Determine the positioning of the chassis in the rack enclosure. Identify the rack post holes that will be used. If the rack post holes are prethreaded, determine if the threads are 10-32 or 12-24. If the rack post holes are unthreaded, install either 10-32 or 12-24 clip or cage nuts over the holes to accept the installation screws. NoteClip or cage nuts are not included as part of the accessory kit that comes with the chassis. You must obtain them yourself. 126562 STATUS STATUS FAN STAT US
1-14 Catalyst 6500 Series Switches Installation Guide OL-5781-08 Chapter 1 Installing the Switch Installing a Catalyst 6504-E Switch Chassis Step 2Remove the chassis shipping bracket before you install the chassis in the rack. Perform the following substeps: a.Loosen and remove the four M5 screws that secure the chassis shipping bracket to the chassis rack mount brackets. (See Figure 1-5.) b.Lift up slightly on the shipping bracket to disengage the two shipping bracket hooks from the rack-mount L brackets. c.Remove the shipping bracket and save it. You must reinstall the shipping bracket if you relocate the chassis. Figure 1-5 Removing the Catalyst 6504-E Chassis Shipping Bracket 1Chassis shipping bracket2M5 Phillips-head screws (4x) 280385 CA UTIONTHIS B RAC KE T IS FO R SH IP PI NG PU RP OS ES ONLY . YO U MU ST RE MOVE THIS BR AC KE T BE FORE SY ST E M INS TAL L A TION AND US E. DO NOT D ISC AR D THI S BR ACK ET . THIS B RAC KE T MUS T BE REPLA CE D ON THE CHASS IS FOR FUTURE SH I PME NTS .4 7 -1 95 2 2- 01 REV A 0 W S- X 65 16 -GE - T X 16 P ORT 1 00 0 BA SE -T GE 12345678910111213141516 L INK ST A T US L INKL IN KL INKLI NKLIN KLI NKLI N KL INKL IN KL INKL INKL IN KL INKLI N KLIN K W S- X 65 16 -GE - T X 16 P OR T 100 0 B A SE -T GE 12345678910111213141 516 L INK ST AT US L IN KL INKL INKLI NKLIN KLI N KLI NKL IN KL IN KL INKL INKL IN KL IN KLI NKLIN K CA TA LY ST 6 50 0 SUP ER V IS OR E NGIN E 3 2C ONS OL E D IS K 0PO RT 1 PO RT 2 PO RT 3 PO RT 4 PO RT 5 PO RT 6 PO RT 7 PO RT 8 W S- S U P3 2- GE - 3B EJECT PO RT 9 CA TA LY S T 650 0 SUP ER V IS OR E NGIN E 3 2C ON S OLE D IS K 0PO RT 1 PO RT 2 PO RT 3 PO RT 4 PO RT 5 PO RT 6 PO RT 7 PO RT 8 W S-S U P3 2-GE - 3B EJECT PO RT 9 1 2
1-15 Catalyst 6500 Series Switches Installation Guide OL-5781-08 Chapter 1 Installing the Switch Installing a Catalyst 6504-E Switch Chassis Step 3With a person standing at each side of the chassis, grasp the chassis handle with one hand, and use the other hand near the back of the chassis for balance. Slowly lift the chassis in unison. Avoid sudden twists or moves to prevent injury. TipHave a third person install the rack-mount screws while two people support the chassis in the rack enclosure. Step 4Align the mounting holes in the rack-mount bracket with the mounting holes in the equipment rack. Step 5If you want to install one or both of the optional cable guides, position the cable guides so that the cable guide mounting holes are aligned with rack-mount holes and the rack post holes. Step 6Install a minimum of eight 10-32 or 12-24 screws (four on each side) through the cable guide mounting holes, rack-mount bracket holes, rack post holes, and into the clip nuts to secure the cable guides and the chassis to the rack post. (See Figure 1-6.) Step 7Use a tape measure or a level to verify that the chassis is installed straight and level. Figure 1-6 Installing a Catalyst 6504-E Switch Chassis in a Rack 126563 STATUS STATUS FAN STATUS
1-16 Catalyst 6500 Series Switches Installation Guide OL-5781-08 Chapter 1 Installing the Switch Installing a Catalyst 6504-E Switch Chassis What is Next After installing the chassis in its location, continue with the installation process by following these procedures: Connecting the chassis to system ground. See “Establishing the System Ground” section on page 1-52. Installing and connecting the power supplies to source power. Go to Chapter 4 for information on how to install and cable power supplies. Connecting the network interface cables to the supervisor engine and modules. This may involve installing transceivers before you attach the network interface cables. See “Attaching the Interface Cables” section on page 1-61. Powering-up the chassis and verifying the installation. See “Verifying Switch Chassis Installation” section on page 1-84. Optional Installation Kits There are no optional installation kits available for the Catalyst 6504-E switch chassis.
1-17 Catalyst 6500 Series Switches Installation Guide OL-5781-08 Chapter 1 Installing the Switch Installing a Catalyst 6506 or Catalyst 6506-E Switch Chassis Installing a Catalyst 6506 or Catalyst 6506-E Switch Chassis This section provides procedures for installing either a Catalyst 6506 or a Catalyst 6506-E switch chassis in a rack assembly and installing the optional cable guide assemblies. Installation Accessory Kits The Catalyst 6506 and Catalyst 6506-E switch chassis are designed to be installed in a standard 19-inch rack, either open or enclosed. Both chassis are normally shipped with the 19-inch rack-mount L brackets factory installed on the left-front and right-front of the chassis. Included with the accessory kit are 10-32 x 0.75-inch and 12-24 x 0.75-inch screws that are used to secure the chassis in the rack enclosure. NoteDepending on the manufacturer, the rack posts might be prethreaded to accept either 10-32 or 12-24 screws. If the rack posts are not prethreaded, you must install 10-32 or 12-24 clip nuts or cage nuts to secure the rack-mount screws. The clip nuts or the cage nuts are not included as part of the accessory kit and must be obtained on your own. Depending on the chassis model, the accessory kit might also contain the following chassis installation kits: Rack-mount shelf kit (Catalyst 6506 and Catalyst 6506-E). The rack-mount shelf kit is used to support the weight of the chassis while you secure the chassis L brackets to the rack enclosure. Rubber feet mount kit (Catalyst 6506-E accessory kit only). This kit should installed when you want to install the Catalyst 6506-E chassis as a freestanding unit on a shelf or a table. Also included in the accessory kit: Two optional cable guides—The two cable guides are installed on the front left- and right-sides of the chassis using the same sets of screws (either 10-32 or 12-24) that secure the chassis rack-mount L brackets to the rack posts. Power supply blank panel—The power supply blank panel must be installed on an unused power supply bay to maintain chassis airflow and EMI shielding. L Brackets on the Catalyst 6506 and the Catalyst 6506-E Switch Chassis The Catalyst 6506 and the Catalyst 6506-E switch chassis are shipped with two L brackets installed on the front sides of the chassis. The L brackets are secured to the chassis with eight M3 Phillips-head countersunk screws (four M3 screws on each side) as shown in Figure 1-7. NoteThe L brackets can also be reversed and installed on the rear of the chassis as an alternative method of installation. NoteThe L brackets for the Catalyst 6506 and Catalyst 6506-E switches are stamped with an L and an R to identify them as left and right.
1-18 Catalyst 6500 Series Switches Installation Guide OL-5781-08 Chapter 1 Installing the Switch Installing a Catalyst 6506 or Catalyst 6506-E Switch Chassis Figure 1-7 L Brackets on the Catalyst 6506 and the Catalyst 6506-E Switch Chassis Installing the 3 RU Rack-Mount Shelf Kit The 3 RU rack-mount shelf kit is included as part of the accessory kit for both the Catalyst 6506 and the Catalyst 6506-E switch chassis. You need to install this kit first before you install the chassis in the rack. The shelf kit supports the weight of the chassis while you install and secure the chassis in the rack. The procedure for installing the shelf kit is located at “Installing the 3 RU Rack-Mount Shelf Kit” section on page 1-47. 1M4 Phillips-head countersunk screws (10x)2Rack-mount L bracket (2x) 280386 INPUT OKFA N OKOUTPUT FA IL o 8 P O R T G IG A B IT E TH E R N E TWS-X64081LI NKSTA TUS2 3 4 5 6 7 8LIN KLI NKLI NKL I NKL I NKL IN KL IN K8 P O R T G IG A B IT E TH E R N E TWS-X64081LI N KSTATUS2 3 4 5 6 78LINKLINKL IN KLI NKL IN KL IN KLINK 24 PORT 100FXW S -X 6 2 2 4S T AT U S1L IN K2LI NK3LIN K4L IN K5L INK6LI NK7L IN K8LI NK9LI NK10LI NK11LI NK12LI NK13LI NK14LI NK15LI NK16LI NK17L IN K18LI NK19L INK20LI NK21L INK22L INK23L INK24LI NK FAN STA TUS 1 2 3 4 5 6 12