    							1-23
    Catalyst 6500 Series Switches Installation Guide
    OL-5781-08
    Chapter 1      Removal and Replacement Procedures
      Removing and Installing the DC-Input Power Supplies
    Figure 1-15 Handling a DC-Input Power Supply
    48134
    FA N
    S TAT U S
    1
    2
    3
    4
    5
    6
    7
    8
    9
    8 PORT GIGABIT ETHERNET
    WS-X64081LINKSTATUS2
    3
    4
    5
    6
    7
    8LINKL
    IN
    KLINKLIN
    KLIN
    KLINKLINK
    8 PORT GIGABIT ETHERNET
    WS-X64081LINKSTATUS2
    3
    4
    5
    6
    7
    8LINKLINKLINKL
    IN
    KLIN
    KLINKLINK
    8 PORT GIGABIT ETHERNET
    WS-X64081LINKSTATUS2
    3
    4
    5
    6
    7
    8LINKLINKLINKLIN
    KLIN
    KLINKLINK
    24
     P
    O
    R
    T
     1
    0
    0
    F
    X
    W
    S
    -
    X
    6
    2
    2
    4S
    T
    A
    T
    U
    S
    2
    4 P
    O
    R
    T
     10
    0F
    X
    W
    S
    -X
    6
    2
    2
    4S
    T
    A
    T
    U
    S
    2
    4
     P
    O
    R
    T
     1
    0
    0
    F
    X
    W
    S
    -X
    6
    2
    2
    4S
    T
    A
    T
    U
    S
    24
     P
    O
    R
    T
     1
    0
    0
    F
    X
    W
    S
    -
    X
    6
    2
    2
    4S
    T
    A
    T
    U
    S
    1LINK2LINK3LINK4LINK5LINK6LINK7LINK8LINK9LINK10LINK11LINK12LINK13LINK14LINK15LINK16LINK17LINK18LINK19LINK20LINK21LINK22LINK23LINK24LINK1LINK2LINK3LINK4LINK5LINK6LINK7LINK8LINK9LINK1
    0LINK1
    1LINK1
    2LINK1
    3LINK1
    4LINK1
    5LINK1
    6LINK1
    7LINK1
    8LINK1
    9LINK2
    0LINK2
    1LINK2
    2LINK2
    3LINK2
    4LINK1LINK2LINK3LINK4LINK5LINK6LINK7LINK8LINK9LINK10LINK11LINK12LINK13LINK14LINK15LINK16LINK17LINK18LINK19LINK20LINK21LINK22LINK23LINK24LINK1LINK2LINK3LINK4LINK5LINK6LINK7LINK8LINK9LINK10LINK11LINK12LINK13LINK14LINK15LINK16LINK17LINK18LINK19LINK20LINK21LINK22LINK23LINK24LINK
    SUPERVISOR2 WS-X6K-SUP2-2GES
    T
    A
    T
    U
    SS
    Y
    S
    T
    E
    MC
    O
    N
    S
    O
    L
    EP
    W
    R
     
    M
    G
    M
    TR
    E
    S
    E
    TCONSOLECONSOLE
    PORT
    MODEPCMCIAEJECTPORT 1PORT 2Switch    Load   
    100%
    1%
    LINK
    LINK
    SUPERVISOR2 WS-X6K-SUP2-2GES
    T
    A
    T
    U
    SS
    Y
    S
    T
    E
    MC
    O
    N
    S
    O
    L
    EP
    W
    R
     
    M
    G
    M
    TR
    E
    S
    E
    TCONSOLECONSOLE
    PORT
    MODEPCMCIA EJECTPORT 1PORT 2Switch    Load   
    100%
    1%
    LINK
    LINK
    INPUT
    OKFA N
    OKOUTPUT
    FAIL
    I
    0 
    						
    							1-24
    Catalyst 6500 Series Switches Installation Guide
    OL-5781-08
    Chapter 1      Removal and Replacement Procedures
      Removing and Installing the DC-Input Power Supplies
    Installing a 1300 W or 2500 W DC-Input Power Supply
    WarningBefore performing any of the following procedures, ensure that power is removed from the DC 
    circuits. To ensure that all power is removed, locate the circuit breakers or fuses on the DC power 
    lines that service the DC circuits. Turn OFF the DC power line circuit breakers and remove the DC 
    power line fuses. Statement 322
    WarningWhen installing or replacing the unit, the ground connection must always be made first and 
    disconnected last. Statement 1046
    To install a DC-input power supply, follow these steps:
    Step 1Ensure that the system (earth) ground connection has been made. For ground connection installation 
    instructions, see the “Establishing the System Ground” section on page 1-52.
    Step 2Verify that power is off to the DC circuit on the power supply that you are installing. As an added 
    precaution, place the appropriate safety flag and lockout devices at the source power circuit breaker, or 
    place a piece of adhesive tape over the circuit breaker handle to prevent accidental power restoration 
    while you are working on the circuit.
    Step 3Verify that the power switch is in the off (0) position on the power supply that you are installing. 
    See Figure 1-11 for the 1300 W DC power supply or Figure 1-12 for the 2500 W DC power supply.
    CautionUse both hands to install and remove power supplies. Each Catalyst 6500 series DC-input power supply 
    weighs between 22 pounds (10 kg) and 28 pounds (12.7 kg). 
    Step 4Grasp the power supply handle with one hand, and place your other hand underneath the power supply. 
    Slide the power supply into the power supply bay. Make sure that the power supply is fully seated in the 
    bay. (See Figure 1-15.)
    Step 5Tighten the power supply captive installation screw. (See Figure 1-11 for the 1300 W DC power supply 
    or Figure 1-12 for the 2500 W DC power supply.)
    Step 6Remove the two screws securing the terminal block cover, and slide the cover off of the terminal block. 
    See Figure 1-11 for the 1300 W DC power supply or Figure 1-12 for the 2500 W DC power supply. 
    						
    							1-25
    Catalyst 6500 Series Switches Installation Guide
    OL-5781-08
    Chapter 1      Removal and Replacement Procedures
      Removing and Installing the DC-Input Power Supplies
    Step 7Attach the appropriate lugs to the DC-input wires. The maximum width of a lug is 0.300 inch (7.6 mm). 
    NoteThe wire should be sized according to local and national installation requirements and electrical 
    codes. Use only copper wire. For North American installations of 2500 WDC-input power 
    supplies, use fine-stranded copper conductors rated for 90°C.
    Step 8Attach the source DC cables to the terminal block (see Figure 1-16 for the 1300 W DC power supply or 
    Figure 1-17 for the 2500 W DC power supply) in this order:
    1.Source ground cable to the power supply terminal block ground post
    2.Source DC negative (–) cable to the power supply terminal block negative (–) post
    3.Source DC positive (+) cable to the power supply terminal block positive (+) post
    NoteThe terminals on the 1300 W DC power supply DC power cable terminal block are labeled (from 
    top to bottom) +, –, ground. The terminals on the 2500 W DC power supply DC power cable 
    terminal block are labeled (from top to bottom) –, +, ground.
    Step 9After ensuring that all wire connections are secure, reinstall the terminal block cover.
    CautionTo prevent a short circuit or shock hazard after wiring the DC-input power supply, you must reinstall the 
    terminal block cover.
    CautionIn a system with dual power supplies, connect each power supply to a separate power source. In case of 
    a power source failure to one supply, the second power source should still be available.
    Step 10Remove any safety flag and lockout devices or any tape from the circuit breaker switch handle, and 
    restore power by moving the circuit breaker switch handle to the on (|) position.
    Step 11Turn the power switch to the on (|) position on the power supply. Turning on the power switch also 
    engages a pawl that locks the power supply in the chassis.
    Step 12Verify the power supply operation by ensuring that the power supply front panel LEDs are in these states:
    INPUT OK LED is green
    FAN OK LED is green
    OUTPUT FAIL LED is not lit
    If the LEDs indicate a power problem, see the “Identifying Startup Problems” section on page A-3. 
    						
    							1-26
    Catalyst 6500 Series Switches Installation Guide
    OL-5781-08
    Chapter 1      Removal and Replacement Procedures
      Removing and Installing the DC-Input Power Supplies
    Figure 1-16 DC-Input Power Supply Connectors (WS-CDC-1300W)
    Figure 1-17 DC-Input Power Supply Connectors (WS-CDC-2500W)
    INPUT
    OKFA N
    OKOUTPUT
    FAIL
    I
    0
    18736
    Power leads attached
    to terminal block
    (+)   Positive
    ( - ) Negative
    (   )   Ground
    Captive 
    installation
    screw
    DC-input power supply
    with the terminal block
    cover removed
    Power
    switch
    DC-input cable
    INPUT
    OKFA N
    OKOUTPUT
    FA I L
    I
    0
    85907
    Power leads
    attached to
    terminal block
    ( - )  Negative
    (+)   Positive
    (   )  Ground
    Captive 
    installation
    screw
    Power
    switch
    DC-input cable 
    						
    							1-27
    Catalyst 6500 Series Switches Installation Guide
    OL-5781-08
    Chapter 1      Removal and Replacement Procedures
      Removing and Installing the DC-Input Power Supplies
    Removing and Installing the 2700 W DC-Input Power Supply
    This section covers the power supply removal and installation procedures for the 2700 W DC-input 
    power supply on the Catalyst 6504-E chassis and is divided into the following topics:
    Required Tools, page 1-28
    Removing a 2700 W DC-Input Power Supply, page 1-29
    Installing a 2700 W DC-Input Power Supply, page 1-32
    The 2700 W DC-input power supply can operate at either 1350 W or at 2700 W. If you want to operate 
    the power supply at 1350 W, you only need to connect one pair of source DC cables to either the VE-1 
    or the VE-2 pair of posts on the power supply terminal block. If you want to operate the power supply 
    at 2700 W, you need to connect two pairs of source DC cables to the VE-1 and the VE-2 pairs of posts 
    on the power supply terminal block.
    NoteFor proper 2700 W DC-input redundant power configurations, all of the source DC for one 2700 W 
    DC-input power supply must come from the same battery system (A feed); all of the source DC for the 
    other 2700 W DC-input power supply must come from another battery system (B feed).
    NoteFor multiple DC-input power supplies, each DC input must be protected by a dedicated circuit breaker 
    or a fuse. The circuit breaker or fuse must be sized according to the power supply input rating and the 
    local or national electrical code requirements.
    Figure 1-18 shows a 2700 W DC-input power supply (p/n PWR-2700-DC/4) cabled for 2700 W 
    operation with the installation components identified. 
    NoteThis illustration shows the source DC cables and the ground cable routed into the power supply from the 
    right side. Two pairs of source DC cables are shown indicating that the power supply is operating at 
    2700 W. The source DC cables and the ground cable can also be routed out of the left-side of the power 
    supply, if necessary.
    Use this illustration as a reference for identifying components when removing or installing the power 
    supply. 
    						
    							1-28
    Catalyst 6500 Series Switches Installation Guide
    OL-5781-08
    Chapter 1      Removal and Replacement Procedures
      Removing and Installing the DC-Input Power Supplies
    Figure 1-18 2700 W DC-Input Power Supply Features
    Required Tools
    The following tools are required for the power supply removal and installation procedures:
    Number 2 Phillips-head screwdriver 
    1/4-inch open-ended wrench or 1/4-inch nutdriver
    Wire cutters to cut the cable tie wraps
    Additional tools might be necessary to install the lugs on the source DC and the ground cables. 
    Additionally, the lugs for the source DC cables and the ground cable are not provided; you must obtain 
    them on your own.1Captive installation screw (4x)7Fixed cable guide, top half
    2Source DC terminal block8Detached cable guide, bottom half
    3Status LEDs9Tie wrap (for source DC cables)
    4Terminal block cover10Fixed cable guide, bottom half
    5Detached cable guide, top half11Tie wrap (for ground cable)
    6Ground terminal block
    132219
    PWR-2700-DC/4
    -VE-1
    -VE-1
    -VE-2
    -VE-2IN
    PU
    T
    1
    O
    K
    48V
    -60
    V
    =40
    AIN
    P
    U
    T2
    O
    K
    48V
    -60V
    =40AF
    A
    N
    O
    KO
    U
    T
    PU
    T
    FA
    IL
    ALL FASTENERS MUST BE F
    ULLY ENG
    AG
    ED
    PRIOR TO O
    PERATING THE PO
    W
    ER SUPPL
    Y
    32
    6
    4
    10
    1
    8
    57
    119 
    						
    							1-29
    Catalyst 6500 Series Switches Installation Guide
    OL-5781-08
    Chapter 1      Removal and Replacement Procedures
      Removing and Installing the DC-Input Power Supplies
    Removing a 2700 W DC-Input Power Supply
    WarningBefore performing any of the following procedures, ensure that power is removed from the DC 
    circuits. To ensure that all power is removed, locate the circuit breakers or fuses on the DC power 
    lines that service the DC circuits. Turn OFF the DC power line circuit breakers and remove the DC 
    power line fuses. Statement 322
    WarningVoltage is present on the backplane when the system is operating. To reduce risk of an electric shock, 
    keep hands and fingers out of the power supply bays and backplane areas. Statement 166
    To remove a DC-input power supply, follow these steps:
    Step 1Verify that source DC power is off to the DC circuit that feeds the power supply that you are removing. 
    As an added precaution, place the appropriate safety flag and lockout devices at the source DC power 
    circuit breaker, or place a piece of adhesive tape over the circuit breaker handle to prevent accidental 
    power restoration while you are working on the circuit.
    Step 2Remove the four screws that secure the terminal block cover (clear plastic) and slide the cover off of the 
    terminal block. Set the cover and the screws aside. (See Figure 1-19.)
    Step 3Remove the two screws securing the fixed cable guide top half and set the cable guide piece and the 
    screws aside. (See Figure 1-19.)
    Step 4Remove the two screws securing the detached cable guide top half to the bottom half. Remove both cable 
    guide pieces and the screws and set them aside.
    NoteIn addition to the two cable guides, there might be a tie wrap securing the source DC cables and 
    two tie wraps securing the ground cable to the fixed cable guide. You will need to cut all of these 
    tie wraps in order to free the source DC cables and the ground cable for removal. 
    						
    							1-30
    Catalyst 6500 Series Switches Installation Guide
    OL-5781-08
    Chapter 1      Removal and Replacement Procedures
      Removing and Installing the DC-Input Power Supplies
    Figure 1-19 Removing the Terminal Block Cover and the Cable Guides
    Step 5
    Disconnect the DC-input cables from the terminal block (see Figure 1-20) in this order:
    Positive (+) source DC cable from the +VE-1 terminal block post
    Negative (-) source DC cable from the –VE-1 terminal block post
    NoteIf you have a second pair of source DC cables attached to the VE-2 terminal block posts, you 
    need to remove the second positive (+) and negative (–) source DC cables, in that order, before 
    you remove the ground cable.
    Ground cable from the ground terminal posts
    Save the 1/4-20 nut and the split-ring washer from each terminal block post and set them aside.
    WarningWhen installing the unit, always make the ground connection first and disconnect it last. Statement 42
    1Terminal block cover4Detached cable guide, bottom half
    2Detached cable guide, top half5Tie wrap (for source DC cables)
    3Fixed cable guide, top half
    270852
    PWR-2700-DC/4
    -VE-1
    -VE-1
    -VE-2
    -VE-2IN
    PU
    T
    1
    O
    K
    48V
    -60V
    =
    40AIN
    P
    U
    T2
    O
    K
    48V-60V
    =4
    0AFA
    N
    O
    KOU
    T
    PU
    T
    FA
    IL
    ALL FA
    STENERS MUST BE F
    ULLY ENGA
    GED
    PRIOR
     TO OPERATING TH
    E POW
    ER SUPPLY1
    4
    23
    5 
    						
    							1-31
    Catalyst 6500 Series Switches Installation Guide
    OL-5781-08
    Chapter 1      Removal and Replacement Procedures
      Removing and Installing the DC-Input Power Supplies
    Figure 1-20 Disconnecting the Source DC Cables and Ground Cable
    Step 6
    Loosen the four captive installation screws on the power supply.
    CautionUse both hands to install and remove power supplies. Each PWR-2700-DC/4 DC-input power supply 
    weighs 19.8 pounds (9.0 kg).
    Step 7Grasp both power supply handles, as shown in Figure 1-21, and slide the power supply completely out 
    of the chassis and set it aside.
    Figure 1-21 Handling a DC-Input Power Supply 
    Step 8
    If the power supply bay is to remain empty, install a blank power supply filler plate (Cisco part number 
    700-03104-01) over the opening, and secure it with the captive installation screws.
    270853
    PW
    R-2700-DC/4
    -V
    E-1
    -V
    E-1
    -V
    E-2
    -V
    E-2INPU
    T
    1
    O
    K
    48
    V-60V
    =
    4
    0AI
    NPU
    T
    2
    OK
    4
    8V-6
    0V
    =
    4
    0AF
    A
    N
    O
    KO
    U
    TP
    U
    T
    F
    AIL
    ALL F
    ASTE
    NERS MUST
     BE FUL
    LY
     ENGAGED
    PRIOR TO OPER
    AT I NG T
    HE 
    POWER SUP
    PLY
    126567
    PWR-2700-DC/4
    ALL FASTENERS MUST BE FULLY ENGAGED
    PRIOR TO OPERATING THE POWER SUPPLY
    INPUT1
    OK
    48V-60V
    =40AINPUT2
    OK
    48V-60V
    =40AFA N
    OKOUTPUT
    FA I L+VE-1
    -VE-1
    +VE-2
    -VE-2
    ALL FASTENERS MUST BE FULLY ENGAGED
    PRIOR TO OPERATING THE POWER SUPPLY
    INPUT1
    OK
    48V-60V
    =40AINPUT2
    OK
    48V-60V
    =40AFA N
    OKOUTPUT
    FA I L
    PWR-2700-DC/4
    +VE-1
    -VE-1
    +VE-2
    -VE-2+VE-1
    -VE-1
    +VE-2
    -VE-2+VE-1
    -VE-1
    +VE-2
    -VE-2
    Power Supply 2
    (redundant)
    Power Supply 1 
    						
    							1-32
    Catalyst 6500 Series Switches Installation Guide
    OL-5781-08
    Chapter 1      Removal and Replacement Procedures
      Removing and Installing the DC-Input Power Supplies
    Installing a 2700 W DC-Input Power Supply
    This section provides the procedures for installing a 2700 W DC-input power supply in the 
    Catalyst 6504-E switch chassis. The 2700 W DC-input power supply can operate at either 1350 W or at 
    2700 W. If you want to operate the power supply at 1350 W you only need to connect one pair of source 
    DC cables to either the VE-1 or the VE-2 lugs on the power supply terminal block. If you want to operate 
    the power supply at 2700 W, you need to connect two pairs of source DC cables to the VE-1 and the 
    VE-2 lugs on the power supply terminal block.
    WarningBefore performing any of the following procedures, ensure that power is removed from the DC 
    circuits. To ensure that all power is removed, locate the circuit breakers or fuses on the DC power 
    lines that service the DC circuits. Turn OFF the DC power line circuit breakers and remove the DC 
    power line fuses. Statement 322 
    NoteFor proper 2700 W DC-input redundant power configurations, all of the source DC for one 2700 W 
    DC-input power supply must come from the same battery system (A feed); all of the source DC for the 
    other 2700 W DC-input power supply must come from another battery system (B feed).
    NoteFor multiple DC-input power supplies, each DC input must be protected by a dedicated circuit breaker 
    or a fuse. The circuit breaker or fuse must be sized according to the power supply input rating and the 
    local or national electrical code requirements.
    To install the 2700 W DC-input power supply in the Catalyst 6504-E chassis and cable it to source DC, 
    follow these steps:
    Step 1Ensure that the system (earth) ground connection has been made. For system ground connection 
    installation instructions, see the “Establishing the System Ground” section on page 1-52.
    Step 2Remove the power supply from its shipping container and remove any packaging material.
    Step 3Locate the plastic bags that accompanied the power supply and set them aside. One bag contains one 
    source DC cable guide, terminal block cover (plastic) with four screws, and two cable ties. The other 
    plastic bag contains the 1/4-20 nuts and lock-washers for the terminal posts. You will use these items 
    later in the procedure.
    Step 4Verify that source DC power is off to the DC circuit that feeds the power supply that you are installing. 
    As an added precaution, place the appropriate safety flag and lockout devices at the source DC circuit 
    breaker, or place a piece of adhesive tape over the circuit breaker handle to prevent accidental power 
    restoration while you are working on the circuit.
    Step 5Grasp both power supply handles, as shown in Figure 1-22. Slide the power supply into the power supply 
    bay. Make sure that the power supply is fully seated in the bay. Tighten the four captive installation 
    screws.
    WarningPower supply captive installation screws must be tight to ensure protective grounding continuity. 
    Statement 289 
    						
    All Cisco manuals Comments (0)