    							1-29
    Catalyst 6500 Series Switches Installation Guide
    OL-5781-08
    Chapter 1      Product Overview
      Catalyst 6506-E Switch
    Physical characteristics
    Dimensions (H x W x D)
    19.2 x 17.5 x 18.2 in. (48.8 x 44.5 x 46.0 cm).
    Chassis depth including cable guide is 21.64 in. (55.0 cm). 
    Chassis requires 12 RU.
    The Catalyst 6506-E switch chassis is designed to install in standard 
    19-inch equipment racks that meet ANSI/EIA 310-D, IEC 60297, and 
    ETS 300-119 standards.
    Weight Chassis only: 50 lb (22.7 kg).
    Chassis fully configured with 1 supervisor engine, 5 switching modules, and 
    2 power supplies: 159 lb (72.3 kg).
    Airflow WS-C6506-E-FAN—564 CFM.
    NoteWe recommend that you maintain a minimum air space of 6 inches 
    (16 cm) between walls and the chassis air vents and a minimum 
    horizontal separation of 12 inches (30.5 cm) between two chassis to 
    prevent overheating.
    Table 1-10 Catalyst 6506-E Switch Specifications (continued)
    Item Specification 
    						
    							1-30
    Catalyst 6500 Series Switches Installation Guide
    OL-5781-08
    Chapter 1      Product Overview
      Catalyst 6509 Switch
    Catalyst 6509 Switch
    The Catalyst 6509 switch is a 9-slot horizontal chassis supporting redundant power supplies, redundant 
    supervisor engines, and slots for up to eight modules. The chassis is NEBS L3 compliant. Figure 1-9 
    shows a front view of the Catalyst 6509 switch chassis.
    Figure 1-9 Catalyst 6509 Switch
    16076
    INPUT
    OKFA N
    OKOUTPUT
    FA I
    L
    o
    INPUT
    OKFA N
    OKOUTPUT
    FA I
    L
    o
    1
    2
    3
    4
    5
    6
    7
    8
    9
    Power supply 2
    (redundant)Power supply 1
    ESD ground strap
    connector
    8 PORT GIGABIT ETHER
    NET
    WS-X64081LIN
    KSTATUS2
    3
    4
    5
    6
    7
    8L
    IN
    KLIN
    KL
    IN
    KLIN
    KLIN
    KLIN
    KLIN
    K
    8 PORT GIGABIT ETHER
    NET
    WS-X64081LIN
    KSTATUS2
    3
    4
    5
    6
    7
    8LINKLINKLIN
    KLINKLINKL
    IN
    KLINK
    8 PORT GIGABIT ETHER
    NET
    WS-X64081LIN
    KSTA
    TUS2
    3
    4
    5
    6
    7
    8LIN
    KLIN
    KLIN
    KLIN
    KL
    IN
    KLIN
    KLIN
    K
    8 PORT GIGABIT ETHER
    NET
    WS-X64081L
    IN
    KSTATUS2
    3
    4
    5
    6
    7
    8LINKLINKL
    INKLINKLINKLIN
    KLINK
    8 P
    O
    RT
     GIG
    A
    BIT
     ET
    HE
    R
    N
    ET
    W
    S
    -
    X
    6
    4
    0
    81LINKSTATUS2
    34
    56
    78LINKLINKLINKLINKLINKLINKLINK
    24 POR
    T 1
    00FX
    WS-X6224S
    T
    AT
    U
    S
    2
    4
     P
    O
    R
    T
     1
    00
    F
    X
    W
    S
    -X
    6
    2
    2
    4S
    T
    AT
    U
    S
    1LINK2LINK3LINK4LINK5LINK6LINK7LINK8LINK9LINK10LINK11LINK12LINK13LINK14LINK15LINK16LINK17LINK18LINK19LINK20LINK21LINK22LINK23LINK24LINK
    1LINK2LINK3LINK4LINK5LINK6LINK7LINK8LINK9LINK1
    0LINK1
    1LINK1
    2LINK1
    3LINK1
    4LINK1
    5LINK1
    6LINK1
    7LINK1
    8LINK1
    9LINK2
    0LINK2
    1LINK2
    2LINK2
    3LINK2
    4LINK
    WS-SUP32-G
    E-3BSTA
    TUS
    SYSTEM
    ACTIVE
    PWR MGMT
    RESETCATALYST   6500 SUPERVIS
    OR  ENGINE  32CONSOLE
    EJECTDISK 0PORT 1
    PORT 2
    PORT 3
    PORT 4PORT 5
    PORT 6
    PORT 7PORT 8PORT 9
    USB 2.0
    LINK
    LINK
    LINK
    LINK
    LINK
    LINK
    LINK
    LINK
    LINKWS-SUP32-G
    E-3BSTA
    TUS
    SYSTEM
    ACTIVE
    PWR MGMT
    RESETCATALYST   6500 SUPERVIS
    OR  ENGINE  32CONSOLE
    EJECTDISK 0PORT 1
    PORT 2
    PORT 3
    PORT 4PORT 5
    PORT 6
    PORT 7PORT 8PORT 9
    USB 2.0
    LINK
    LINK
    LINK
    LINK
    LINK
    LINK
    LINK
    LINK
    LINK
    Switching
    modules
    Switching
    modules
    Fan assembly
    Supervisor engine
    Redundant supervisor
    engine 
    						
    							1-31
    Catalyst 6500 Series Switches Installation Guide
    OL-5781-08
    Chapter 1      Product Overview
      Catalyst 6509 Switch
    Ta b l e 1 - 1 1 lists the features of the Catalyst 6509 switch chassis. 
    Table 1-11 Catalyst 6509 Switch Features
    Feature Description
    Chassis
    Nine horizontal slots. Slots are numbered from 1 (top) to 9 (bottom).
    Supervisor engines
    Supports Supervisor Engine 2, Supervisor Engine 32, Supervisor 
    Engine 32 PISA, Supervisor Engine 720, and Supervisor 
    Engine 720-10GE. 
    NoteRefer to your software release notes for the minimum software 
    release versions required to support the supervisor engines.
    –Supervisor Engine 2 must be installed in slot 1 and slot 2.
    –Supervisor Engine 32, Supervisor Engine 32 PISA, Supervisor 
    Engine 720, and Supervisor Engine 720-10GE must be installed in 
    slot 5 and slot 6.
    NoteSlots not occupied by supervisor engines can be used for modules. 
    Check your software release notes for any restrictions on the type of 
    module that can be installed.
    Supervisor Engine 32, Supervisor Engine 32 PISA, Supervisor 
    Engine 720, and Supervisor Engine 720-10GE require that the 
    high-speed fan tray be installed in the chassis. You must also install a 
    2500 W or higher capacity power supply in the chassis to power the 
    high-speed fan tray.
    NoteThe 2500 W power supply, when supporting the high-speed fan tray, 
    can be powered from either 120 VAC or 220 VAC.
    Supervisor Engine 720 and Supervisor Engine 720-10GE have a built-in 
    switching fabric. Switch Fabric Modules (WS-C6500-SFM and 
    WS-X6500-SFM2) are not supported by Supervisor Engine 720 and 
    Supervisor Engine 720-10GE. 
    Supervisor Engine 32 and Supervisor Engine 32 PISA do not support 
    the Switch Fabric Modules (WS-C6500-SFM and WS-X6500-SFM2). 
    The uplink ports are fully functional on all redundant supervisor engine 
    models when they are in standby mode.
    NoteIn systems with redundant supervisor engines, both supervisor 
    engines must be the same model and have the same daughter card 
    configurations. Each supervisor engine must have the resources to 
    run the switch on its own, which means that all supervisor engine 
    resources are duplicated. Identical supervisor engine memory 
    configurations are recommended, but are not required as long as the 
    supervisor engine with the smaller memory configuration is 
    sufficient to run the configured features of the switch. Additionally, 
    each supervisor engine must have its own flash device and console 
    port connections. 
    						
    							1-32
    Catalyst 6500 Series Switches Installation Guide
    OL-5781-08
    Chapter 1      Product Overview
      Catalyst 6509 Switch
    ModulesSupports up to eight Catalyst 6500 series modules.
    WS-C6500-SFM and WS-X6500-SFM2 Switch Fabric Modules must be 
    installed in slot 5 or slot 6.
    NoteMixing WS-C6500-SFM and WS-X6500-SFM2 Switch Fabric 
    Modules in the Catalyst 6509 chassis is allowed.
    Some Catalyst 6500 series modules may:
    –Not be supported
    –Require that you install a Supervisor Engine 720
    –Have chassis slot restrictions
    –Require a specific software release level to operate
    NoteCheck your software release notes for specific information on 
    modules supported and restrictions.
    Backplane bandwidth
    32 GBps shared bus.
    256 GBps switch fabric.
    720 GBps switch fabric.
    Clock and VTT modules
    Two replaceable clock modules (WS-C6K-CL=) provide clocking 
    signals to the EOBC channel and the switching bus.
    Three replaceable voltage termination (VTT) modules 
    (WS-C6K-VTT=) provide reference voltage for bus signals.
    Fan tray
    The chassis supports one hot-swappable fan tray. Two fan tray models 
    are available:
    –WS-C6K-9SLOT-FAN (Standard fan tray—340 CFM). Supports 
    Supervisor Engine 1 and Supervisor Engine 2 only; does not 
    support Supervisor Engine 32 or Supervisor Engine 720.
    –WS-C6K-9SLOT-FAN2 (Optional high-speed fan tray—630 CFM). 
    Required for Supervisor Engine 32 and Supervisor Engine 720. 
    Supports Supervisor Engine 1 and Supervisor Engine 2.
    NoteYou must install a 2500 W or higher capacity power supply in the 
    chassis to power the high-speed fan tray. The 2500 W power supply 
    can be powered from either 120 VAC or 220 VAC.
    NoteThe fan tray contains nine individual fans. The individual fans are 
    not field replaceable; you must replace the fan tray in the event of a 
    fan failure.
    Fan tray STATUS LED
    –Red—One or more individual fans have failed.
    –Green—Fan tray is operating normally.
    Table 1-11 Catalyst 6509 Switch Features (continued)
    Feature Description 
    						
    							1-33
    Catalyst 6500 Series Switches Installation Guide
    OL-5781-08
    Chapter 1      Product Overview
      Catalyst 6509 Switch
    Power supplySupports one or two power supplies. The following power supply 
    models are supported:
    –WS-CAC-1000W (1000 W AC-input power supply).
    –WS-CAC-1300W (1300 W AC-input power supply).
    –WS-CDC-1300W (1300 W DC-input power supply).
    –WS-CAC-2500W (2500 W AC-input power supply).
    –WS-CDC-2500W (2500 W DC-input power supply).
    –WS-CAC-3000W (3000 W AC-input power supply).
    –WS-CAC-4000W-US (4000 W AC-input power supply).
    –WS-CAC-4000W-INT (4000 W AC-input power supply).
    –PWR-4000-DC (4000 W DC-input power supply).
    –WS-CAC-6000W (6000 W AC-input power supply).
    –PWR-6000-DC (6000 W DC-input power supply).
    –WS-CAC-8700W-E (8700 W AC-input power supply).
    NoteThe 6000 W AC-input and DC-input power supplies and the 8700 W 
    AC-input power supply are limited to 4000 W maximum output 
    when installed in the Catalyst 6509 chassis.
    Installed power supplies can be of different wattage ratings. Installed 
    power supplies can also be both AC-input, both DC-input, or one 
    AC-input and one DC-input. Power supplies can be configured in either 
    redundant or combined mode.
    All Catalyst 6500 series AC-input power supplies require single-phase 
    source AC. Source AC can be out of phase between multiple power 
    supplies or multiple AC-power plugs on the same power supply because 
    all AC power supply inputs are isolated.
    Single power supplies are installed in the left power supply bay. The 
    second (redundant) power supply is installed in the right power supply 
    bay.
    You must install a 2500 W or higher capacity power supply when using 
    the Supervisor Engine 32 or the Supervisor Engine 720 and the 
    high-speed fan tray.
    NoteFor proper operation of the power supply OUTPUT FAIL LED, 
    systems with single power supplies must be configured with a 
    minimum of one fan tray and one supervisor engine. Systems with 
    dual power supplies must have a minimum configuration of one fan 
    tray, one supervisor engine, and one additional module. Failure to 
    meet these minimum configuration requirements can cause a false 
    power supply output fail signal.
    Table 1-11 Catalyst 6509 Switch Features (continued)
    Feature Description 
    						
    							1-34
    Catalyst 6500 Series Switches Installation Guide
    OL-5781-08
    Chapter 1      Product Overview
      Catalyst 6509 Switch
    Ta b l e 1 - 1 2 lists the environmental and physical specifications of the Catalyst 6509 switch chassis.
    Table 1-12 Catalyst 6509 Switch Specifications
    Item Specification
    Environmental
    Temperature, operating Certified for operation: 32° to 104°F (0° to 40°C)
    Designed and tested for operation: 32° to 131°F (0° to 55°C)
    NoteThe Catalyst 6500 series switches are equipped with internal air 
    temperature sensors that are triggered at 104°F (40°C) generating a 
    minor alarm and at 131°F (55°C) generating a major alarm.
    Temperature, nonoperating 
    and storageChassis unpackaged: –4° to 149°F (–20° to 65°C)
    Chassis in protective shipping package: –40° to 158°F (–40° to 70°C)
    Thermal transition 0.5°C per minute (hot to cold)
    0.33°C per minute (cold to hot)
    Humidity (RH), ambient 
    (noncondensing) operating 5% to 90%
    Humidity (RH), ambient 
    (noncondensing) 
    nonoperating and storage 5% to 95% 
    Altitude, operating Certified for operation: 0 to 6500 ft (0 to 2000 m)
    Designed and tested for operation: –200 to 10,000 ft (–60 to 3000 m)
    Shock and vibration This switch complies with Network Equipment Building Systems (NEBS) 
    (Zone 4 per GR-63-Core) in the following areas:
    Earthquake environment and criteria
    Office vibration and criteria
    Transportation vibration and criteria
    Shock
    
    Operational—5 G 30 ms, half-sine (IEC 68-2-27)
    Nonoperational—20 G, 7.5 ms, trapezoidal
    Vibration 
    Operational—3 Hz to 500 Hz. 
    Power Spectral Density (PSD)—0.0005 G2/Hz at 10 Hz and 200 Hz. 
    5 dB/octave roll off at each end. 0.5 hours per axis (1.12 Grms).
    Acoustic noise 53.6 to 68 dB. International Organization for Standardization (ISO) 7779: 
    Bystander position operating to an ambient temperature of 86°F (30°C). 
    						
    							1-35
    Catalyst 6500 Series Switches Installation Guide
    OL-5781-08
    Chapter 1      Product Overview
      Catalyst 6509 Switch
    Physical characteristics
    Dimensions (H x W x D)
    25.3 x 17.2 x 18.2 in. (64.0 x 43.7 x 46.0 cm).
    Chassis depth including cable guide is 21.64 in. (55.0 cm). 
    Chassis requires 15 RU1.
    The Catalyst 6509 switch chassis is designed to install in standard 
    19-inch equipment racks that meet ANSI/EIA 310-D, IEC 60297, and 
    ETS 300-119 standards.
    Weight Chassis only: 55 lb (24.9 kg).
    Chassis fully configured with 1 supervisor engine, 8 switching modules, and 
    2 power supplies: 194.5 lb (88.2 kg).
    Airflow WS-C6K-9SLOT-FAN (Standard fan tray)—340 CFM
    WS-C6K-9SLOT-FAN2 (Optional high-speed fan tray)—630 CFM
    NoteTo maintain proper air circulation through the Catalyst switch 
    chassis, we recommend that you maintain a minimum 6-inch (15 cm) 
    separation between a wall and the chassis air intake or a wall and the 
    chassis air exhaust. You should also allow a minimum separation of 
    12 inches (30.5 cm) between the hot air exhaust on one chassis and 
    the air intake on another chassis. Failure to maintain adequate air 
    space can cause the chassis to overheat and the system to fail. On 
    Catalyst chassis in which the airflow is from front to back, the 
    chassis may be placed side-by-side. 
    1. RU = rack units
    Table 1-12 Catalyst 6509 Switch Specifications (continued)
    Item Specification 
    						
    							1-36
    Catalyst 6500 Series Switches Installation Guide
    OL-5781-08
    Chapter 1      Product Overview
      Catalyst 6509-E Switch
    Catalyst 6509-E Switch
    The Catalyst 6509-E switch is an enhanced version of the Catalyst 6509 switch. The 9-slot horizontal 
    chassis supports redundant power supplies, redundant supervisor engines, and slots for up to eight 
    modules. It also supports a greater power capacity per slot than the Catalyst6509 switch chassis. The 
    Catalyst 6509-E switch chassis is NEBS L3 compliant. Figure 1-10 shows the Catalyst 6509-E switch.
    Figure 1-10 Catalyst 6509-E Switch 
    113676
    FA N
    STA
    TUS
    INPUT
    OKFA N
    OKOUTPUT
    FA I
    L
    o
    INPUT
    OKFA N
    OKOUTPUT
    FA I
    L
    o
    1
    2
    3
    4
    5
    6
    7
    8
    9
    Power supply 2
    (redundant)Power supply 1
    ESD ground strap
    connector
    8 PORT GIGABIT ETHERNET
    WS-X64081LINKSTATUS2
    3
    4
    5
    6
    7
    8LINKLINKLINKLINKLINKLIN
    KLINK
    8 PORT GIGABIT ETHERNET
    WS-X64081LINKSTATUS2
    3
    4
    5
    6
    7
    8LIN
    KLINKLINKLINKLINKLIN
    KLIN
    K
    8 PORT GIGABIT ETHER
    NET
    WS-X64081LIN
    KSTATUS2
    3
    4
    5
    6
    7
    8LINKLINKLINKLIN
    KLINKLIN
    KLINK
    8 PORT GIGABIT ETHERNET
    WS-X64081LINKSTATUS2
    3
    4
    5
    6
    7
    8LINKLINKLINKLINKLINKLIN
    KLIN
    K
    8
     P
    OR
    T
     G
    IG
    AB
    IT E
    T
    HER
    N
    ET
    W
    S
    -X
    6
    4
    0
    81LINKS
    T
    AT
    U
    S2
    34
    56
    7
    8LINKLINKLINKLINKLINKLINKLINK
    24 PORT 1
    00FX
    WS-
    X6224STATUS
    2
    4
     P
    O
    R
    T
     1
    0
    0
    F
    X
    W
    S
    -
    X
    6
    2
    2
    4S
    T
    AT
    U
    S
    1LINK2LINK3LINK4LINK5LINK6LINK7LINK8LINK9LINK10LINK11LINK12LINK13LINK14LINK15LINK16LINK17LINK18LINK19LINK20LINK21LINK22LINK23LINK24LINK
    1LINK2LINK3LINK4LINK5LINK6LINK7LINK8LINK9LINK1
    0LINK1
    1LINK1
    2LINK1
    3LINK1
    4LINK1
    5LINK1
    6LINK1
    7LINK1
    8LINK1
    9LINK2
    0LINK2
    1LINK2
    2LINK2
    3LINK2
    4LINK
    WS-SUP32-G
    E-3BSTA
    TUS
    SYSTEM
    ACTIVE
    PWR MGMT
    RESETCATALYST   6500 SUPERVIS
    OR  ENGINE  32CONSOLE
    EJECTDISK 0PORT 1
    PORT 2
    PORT 3
    PORT 4PORT 5
    PORT 6
    PORT 7PORT 8PORT 9
    USB 2.0
    LINK
    LINK
    LINK
    LINK
    LINK
    LINK
    LINK
    LINK
    LINKWS-SUP32-GE-3BSTA
    TUS
    SYSTEM
    ACTIVE
    PWR MGMT
    RESETCATALYST   6500 SUPERVIS
    OR  ENGINE  32
    CONSOLE
    EJECTDISK 0PORT 1
    PORT 2
    PORT 3
    PORT 4PORT 5
    PORT 6
    PORT 7PORT 8PORT 9
    USB 2.0
    LINK
    LINK
    LINK
    LINK
    LINK
    LINK
    LINK
    LINK
    LINK
    Switching
    modules
    Switching
    modules
    Fan assembly
    Supervisor engine
    Redundant supervisor
    engine 
    						
    							1-37
    Catalyst 6500 Series Switches Installation Guide
    OL-5781-08
    Chapter 1      Product Overview
      Catalyst 6509-E Switch
    Table 1-13 lists the features of the Catalyst 6509-E switch chassis. 
    Table 1-13 Catalyst 6509-E Switch Features
    Feature Description
    Chassis
    Nine horizontal slots. Slots are numbered from (1) top to (9) bottom.
    Supervisor engines
    Supports Supervisor Engine 2, Supervisor Engine 32, Supervisor 
    Engine 32 PISA, Supervisor Engine 720, Supervisor Engine 720-10GE, 
    and Supervisor Engine 2T. 
    NoteRefer to your software release notes for the minimum software 
    release versions required to support the supervisor engines.
    –Supervisor Engine 2 must be installed in slot 1 and slot 2.
    –Supervisor Engine 32, Supervisor Engine 32 PISA, Supervisor 
    Engine 720, Supervisor Engine 720-10GE, and Supervisor 
    Engine 2T must be installed in slot 5 and slot 6.
    NoteSlots not occupied by supervisor engines can be used for modules. 
    Check your software release notes for any restrictions on the type of 
    module that can be installed.
    Supervisor Engine 720 and Supervisor Engine 720-10GE , and 
    Supervisor Engine 2T have a built-in switching fabric. Switch Fabric 
    Modules (WS-C6500-SFM and WS-X6500-SFM2) are not supported.
    Supervisor Engine 32 and Supervisor Engine 32 PISA do not support 
    the Switch Fabric Modules (WS-C6500-SFM and WS-X6500-SFM2). 
    The uplink ports are fully functional on all redundant supervisor engine 
    models when they are in standby mode.
    NoteIn systems with redundant supervisor engines, both supervisor 
    engines must be the same model and have the same daughter card 
    configurations. Each supervisor engine must have the resources to 
    run the switch on its own, which means that all supervisor engine 
    resources are duplicated. Identical supervisor engine memory 
    configurations are recommended, but are not required as long as the 
    supervisor engine with the smaller memory configuration is 
    sufficient to run the configured features of the switch. Additionally, 
    each supervisor engine must have its own flash device and console 
    port connections. 
    						
    							1-38
    Catalyst 6500 Series Switches Installation Guide
    OL-5781-08
    Chapter 1      Product Overview
      Catalyst 6509-E Switch
    ModulesSupports up to eight Catalyst 6500 series modules.
    WS-C6500-SFM and WS-X6500-SFM2 Switch Fabric Modules must be 
    installed in slot 5 or slot 6.
    NoteMixing WS-C6500-SFM and WS-X6500-SFM2 Switch Fabric 
    Modules in the Catalyst 6509-E chassis is allowed.
    Some Catalyst 6500 series modules may:
    –Not be supported
    –Require that you install a Supervisor Engine 720
    –Have chassis slot restrictions
    –Require a specific software release level to operate
    NoteCheck your software release notes for specific information on 
    module supported and restrictions.
    Backplane bandwidth
    32 GBps shared bus.
    256 GBps switch fabric.
    720 GBps switch fabric.
    Clock and VTT modules
    Two replaceable clock modules (CLK-7600=) provide clocking signals 
    to the EOBC channel and the switching bus.
    Three replaceable voltage termination (VTT) modules 
    (WS-C6K-VTT-E=) provide reference voltage for bus signals.
    Fan tray
    The chassis supports one hot-swappable fan tray. One fan tray model is 
    available:
    –WS-C6509-E-FAN—846 CFM
    NoteYou must install a 2500 W or higher capacity power supply in the 
    chassis to power the high-speed fan tray. The 2500 W power supply 
    can be powered from either 120 VAC or 220 VAC.
    NoteThe fan tray contains nine individual fans. The individual fans are 
    not field replaceable; you must replace the fan tray in the event of a 
    fan failure.
    Fan tray STATUS LED
    –Red—One or more individual fans have failed.
    –Green—Fan tray is operating normally.
    Table 1-13 Catalyst 6509-E Switch Features (continued)
    Feature Description 
    						
    All Cisco manuals Comments (0)