1-9 Catalyst 6500 Series Switches Installation Guide OL-5781-08 Chapter 1 Product Overview Catalyst 6503-E Switch Ta b l e 1 - 3 lists the features of the Catalyst 6503-E switch chassis. Table 1-3 Catalyst 6503-E Switch Features Feature Description Chassis Three horizontal slots. Slots are numbered from 1 (top) to 3 (bottom). Supervisor engine Supports Supervisor Engine 2, Supervisor Engine 32, Supervisor Engine 32 PISA, Supervisor Engine 720, Supervisor Engine 720-10GE, and Supervisor Engine 2T. NoteRefer to your software release notes for the minimum software release versions required to support the supervisor engines. Supervisor engines can be installed in either slot 1 or slot 2. NoteSlots not occupied by supervisor engines can be used for modules. Check your software release notes for any restrictions on the type of module that can be installed. Supervisor Engine 720, Supervisor Engine 720-10GE, and Supervisor Engine 2T have a built-in switching fabric. Switch Fabric Modules (WS-C6500-SFM and WS-X6500-SFM2) are not supported. Supervisor Engine 32 and Supervisor Engine 32 PISA do not support the Switch Fabric Modules (WS-C6500-SFM and WS-X6500-SFM2). The uplink ports are fully functional on the redundant supervisor engine when it is in standby mode. NoteIn systems with redundant supervisor engines, both supervisor engines must be the same model and have the same daughter card configurations. Each supervisor engine must have the resources to run the switch on its own, which means that all supervisor engine resources are duplicated. Identical supervisor engine memory configurations are recommended, but are not required as long as the supervisor engine with the smaller memory configuration is sufficient to run the configured features of the switch. Additionally, each supervisor engine must have its own flash device and console port connections. Modules Supports up to two Catalyst 6500 series modules. Does not support the WS-C6500-SFM and WS-X6500-SFM2 Switch Fabric Modules. Some Catalyst 6500 series modules may: –Not be supported –Require that you install a certain supervisor engine –Have chassis slot restrictions –Require a specific software release level to operate NoteCheck your software release notes for specific information on module support and restrictions.
1-10 Catalyst 6500 Series Switches Installation Guide OL-5781-08 Chapter 1 Product Overview Catalyst 6503-E Switch Backplane bandwidth32 GBps shared bus. 720 GBps switch fabric. Clock and VTT module One replaceable clock module (CLK-7600=) provides clocking signals to the EOBC channel and the switching bus. Nonreplaceable voltage termination (VTT) module provides reference voltage for bus signals. Fan tray The chassis supports one hot-swappable fan tray. One fan tray model is available: –WS-C6503-E-FAN—282 CFM NoteThe fan tray contains four individual fans. The individual fans are not field replaceable; you must replace the fan tray in the event of a fan failure. Fan tray STATUS LED –Red—One or more individual fans have failed. –Green—Fan tray is operating normally. Power Entry Module (PEM) 1A PEM is required for each installed power supply. –PEM-15A-AC (PEM for 950 W AC-input power supplies). –PEM-DC/3 (PEM for 950 W DC-input power supplies). –PEM-20A-AC+ (PEM for 1400 W AC-input power supplies). Table 1-3 Catalyst 6503-E Switch Features (continued) Feature Description
1-11 Catalyst 6500 Series Switches Installation Guide OL-5781-08 Chapter 1 Product Overview Catalyst 6503-E Switch Ta b l e 1 - 4 lists the environmental and physical specifications of the Catalyst 6503-E switch chassis. Power supplies Supports one or two power supplies. The following power supplies are supported: –PWR-950-AC (950 W AC-input power supply). –PWR-950-DC (950 W DC-input power supply). –PWR-1400-AC (1400 W AC-input power supply). Installed power supplies can be of different wattage ratings. Installed power supplies can be both AC-input, both DC-input, or one AC-input and one DC-input. Power supplies can be configured in either redundant or combined mode. All Catalyst 6500 series AC-input power supplies require single-phase source AC. Source AC can be out of phase between multiple power supplies or multiple AC-power plugs on the same power supply because all AC power supply inputs are isolated. Single power supplies are installed in the lower power supply bay. The second power supply is installed in the upper power supply bay. Supervisor Engine 2T requires a 1400 W power supply to operate. NoteFor proper operation of the power supply OUTPUT FAIL LED, systems with single power supplies must be configured with a minimum of one fan tray and one supervisor engine. Systems with dual power supplies must have a minimum configuration of one fan tray, one supervisor engine, and one additional module. Failure to meet these minimum configuration requirements can cause a false power supply output fail signal. 1. PEMs are required for Catalyst 6503 and Catalyst 6503-E switches only. Table 1-3 Catalyst 6503-E Switch Features (continued) Feature Description Table 1-4 Catalyst 6503-E Switch Specifications Item Specification Environmental Temperature, operating Certified for operation: 32° to 104°F (0° to 40°C) Designed and tested for operation: 32° to 131°F (0° to 55°C) NoteThe Catalyst 6500 series switches are equipped with internal air temperature sensors that are triggered at 104°F (40°C) generating a minor alarm and at 131°F (55°C) generating a major alarm. Temperature, nonoperating and storageChassis unpackaged: –4° to 149°F (–20° to 65°C) Chassis in protective shipping package: –40° to 158°F (–40° to 70°C) Thermal transition 0.5°C per minute (hot to cold) 0.33°C per minute (cold to hot) Humidity (RH), ambient (noncondensing) operating 5% to 90%
1-12 Catalyst 6500 Series Switches Installation Guide OL-5781-08 Chapter 1 Product Overview Catalyst 6503-E Switch Humidity (RH), ambient (noncondensing) nonoperating and storage 5% to 95% Altitude, operating Certified for operation: 0 to 6500 ft Designed and tested for operation: –200 to 10000 ft (–60 to 3000 m) Shock and vibration This switch complies with Network Equipment Building Systems (NEBS) (Zone 4 per GR-63-Core) in the following areas: Earthquake environment and criteria Office vibration and criteria Transportation vibration and criteria Shock Operational—5 G 30 ms, half-sine (IEC 68-2-27) Nonoperational—20 G, 7.5 ms, trapezoidal Vibration Operational—3 Hz to 500 Hz, Power Spectral Density (PSD)—0.0005 G2/Hz at 10 Hz and 200 Hz. 5 dB/octave roll off at each end. 0.5 hours per axis (1.12 Grms). Acoustic noise 64 to 76 dB. International Organization for Standardization (ISO) 7779: Bystander position operating to an ambient temperature of 86°F (30°C). Physical characteristics Dimensions (H x W x D) 7 x 17.37 x 21.75 in. (17.8 x 44.1 x 55.2 cm). Chassis requires 4 RU1. The Catalyst 6503-E switch chassis is designed to install in standard 19-inch equipment racks that meet ANSI/EIA 310-D, IEC 60297, and ETS 300-119 standards. Weight Chassis only: 33 lb (15 kg). Chassis fully configured with 1 supervisor engine, 2 modules, 2 AC-input PEMs, and 2 AC-input power supplies: 85.4 lb (38.7 kg). Airflow WS-C6503-E-FAN—282 CFM NoteTo maintain proper air circulation through the Catalyst switch chassis, we recommend that you maintain a minimum 6-inch (15 cm) separation between a wall and the chassis air intake or a wall and the chassis air exhaust. You should also allow a minimum separation of 12 inches (30.5 cm) between the hot air exhaust on one chassis and the air intake on another chassis. Failure to maintain adequate air space can cause the chassis to overheat and the system to fail. On Catalyst chassis in which the airflow is from front to back, the chassis may be placed side-by-side. 1. RU = rack units Table 1-4 Catalyst 6503-E Switch Specifications (continued) Item Specification
1-13 Catalyst 6500 Series Switches Installation Guide OL-5781-08 Chapter 1 Product Overview Catalyst 6504-E Switch Catalyst 6504-E Switch The Catalyst 6504-E switch is a 4-slot horizontal chassis that supports redundant power supplies, redundant supervisor engines, and slots for up to three modules. The Catalyst 6504-E switch chassis is NEBS L3 compliant. Figure 1-5 shows the front view of the chassis and Figure 1-6 shows the rear view of the chassis. Figure 1-5 Catalyst 6504-E Switch—Front View Figure 1-6 Catalyst 6504-E Switch—Rear View 126559 STATUS FAN STATUS STATUS Slots 1-4 (top to bottom) Supervisor Engine OSMs Redundant Supervisor Engine 126560 P W R -2700-AC INPUT OKFA N OKOUTPUT FAIL ALL F ASTENERS MUST BE FULLY ENGAGED PRIOR TO OPERATING THE POW ER SUPP LY 100-240 V-16A 50/60Hz PW R-270 0-AC INPUT OKF AN OKOUTPUT FAIL ALL F ASTENERS M UST BE FU LLY ENGA GED PRIO R TO OPER A TIN G THE P OW ER SUPPL Y 100-240V-16A 50/60Hz Power Supply 1Power Supply 2 (redundant)
1-14 Catalyst 6500 Series Switches Installation Guide OL-5781-08 Chapter 1 Product Overview Catalyst 6504-E Switch Ta b l e 1 - 5 lists the features of the Catalyst 6504-E switch chassis. Table 1-5 Catalyst 6504-E Switch Features Feature Description Chassis Four horizontal slots. Slots are numbered from 1 (top) to 4 (bottom). Supervisor engine Supports Supervisor Engine 2, Supervisor Engine 32, Supervisor Engine 32 PISA, Supervisor Engine 720, and Supervisor Engine 720-10GE. NoteRefer to your software release notes for the minimum software release versions required to support the supervisor engines. Supervisor engines are installed in slot 1 and slot 2. NoteSlots not occupied by supervisor engines can be used for modules. Check your software release notes for any restrictions on the type of module that can be installed. Supervisor Engine 720, Supervisor Engine 720-10GE, and Supervisor Engine 2T have a built-in switching fabric. Switch Fabric Modules (WS-C6500-SFM and WS-X6500-SFM2) are not supported. Supervisor Engine 32 and Supervisor Engine 32 PISA do not support the Switch Fabric Modules (WS-C6500-SFM and WS-X6500-SFM2). The uplink ports are fully functional on the redundant supervisor engine when it is in standby mode. NoteIn systems with redundant supervisor engines, both supervisor engines must be the same model and have the same daughter card configurations. Each supervisor engine must have the resources to run the switch on its own, which means that all supervisor engine resources are duplicated. Identical supervisor engine memory configurations are recommended, but are not required as long as the supervisor engine with the smaller memory configuration is sufficient to run the configured features of the switch. Additionally, each supervisor engine must have its own flash device and console port connections. Modules Supports up to three Catalyst 6500 series modules. Does not support the WS-C6500-SFM and WS-X6500-SFM2 Switch Fabric Modules. Some Catalyst 6500 series modules may: –Not be supported or have slot restrictions –Require that you install a Supervisor Engine 720 –Require a specific software release level to operate NoteCheck your software release notes for specific information. Backplane bandwidth 32 GBps shared bus. 720 GBps switch fabric.
1-15 Catalyst 6500 Series Switches Installation Guide OL-5781-08 Chapter 1 Product Overview Catalyst 6504-E Switch Clock and VTT moduleOne replaceable clock module (CLK-7600=) provides clocking signals to the EOBC channel and the switching bus. Nonreplaceable voltage termination (VTT) module provides reference voltage for bus signals. Fan tray The chassis supports one hot-swappable fan tray. One fan tray model is available: –FAN-MOD-4HS—300 CFM NoteThe fan tray contains eight individual fans. The individual fans are not field replaceable; you must replace the fan tray in the event of a fan failure. Fan tray STATUS LED –Red—One or more individual fans have failed. –Green—Fan tray is operating normally. Power supplies Supports one or two power supplies. The following power supplies are supported: –PWR-2700-AC/4 (2700 W AC-input power supply). –PWR-2700-DC/4 (2700 W DC-input power supply). Installed power supplies can be both AC-input, both DC-input, or one AC-input and one DC-input. Power supplies can be configured in either redundant or combined mode. All Catalyst 6500 series AC-input power supplies require single-phase source AC. Source AC can be out of phase between multiple power supplies or multiple AC-power plugs on the same power supply because all AC power supply inputs are isolated. Single power supplies are installed in the lower power supply bay. The second power supply is installed in the upper power supply bay. NoteFor proper operation of the power supply OUTPUT FAIL LED, systems with single power supplies must be configured with a minimum of one fan tray and one supervisor engine. Systems with dual power supplies must have a minimum configuration of one fan tray, one supervisor engine, and one additional module. Failure to meet these minimum configuration requirements can cause a false power supply output fail signal. Table 1-5 Catalyst 6504-E Switch Features (continued) Feature Description
1-16 Catalyst 6500 Series Switches Installation Guide OL-5781-08 Chapter 1 Product Overview Catalyst 6504-E Switch Ta b l e 1 - 6 lists the environmental and physical specifications of the Catalyst 6504-E switch chassis. Table 1-6 Catalyst 6504-E Switch Specifications Item Specification Environmental Temperature, operating Certified for operation: 32° to 104°F (0° to 40°C) Designed and tested for operation: 32° to 131°F (0° to 55°C) NoteThe Catalyst 6500 series switches are equipped with internal air temperature sensors that are triggered at 104°F (40°C) generating a minor alarm and at 131°F (55°C) generating a major alarm. Temperature, nonoperating and storageChassis unpackaged: –4° to 149°F (–20° to 65°C) Chassis in protective shipping package: –40° to 158°F (–40° to 70°C) Thermal transition 0.5°C per minute (hot to cold) 0.33°C per minute (cold to hot) Humidity (RH), ambient (noncondensing) operating 5% to 90% Humidity (RH), ambient (noncondensing) nonoperating and storage 5% to 95% Altitude, operating Certified for operation: 0 to 6500 ft (0 to 2000 m) Designed and tested for: –200 to 10,000 ft (–60 to 3000 m) Shock and vibration This switch complies with Network Equipment Building Systems (NEBS) (Zone 4 per GR-63-Core) in the following areas: Earthquake environment and criteria Office vibration and criteria Transportation vibration and criteria Shock Operational—5 G 30 ms, half-sine (IEC 68-2-27) Nonoperational—20 G, 7.5 ms, trapezoidal Vibration Operational—3 Hz to 500 Hz. Power Spectral Density (PSD)—0.0005 G2/Hz at 10 Hz and 200 Hz. 5 dB/octave roll off at each end. 0.5 hours per axis (1.12 Grms).
1-17 Catalyst 6500 Series Switches Installation Guide OL-5781-08 Chapter 1 Product Overview Catalyst 6504-E Switch Acoustic noise 64 to 76 dB. International Organization for Standardization (ISO) 7779: Bystander position operating to an ambient temperature of 86°F (30°C). Physical characteristics Dimensions (H x W x D) 8.75 x 17.5 x 21.75 in. (22.225 x 44.45 x 55.245 cm). Chassis requires 5 RU1. The Catalyst 6504-E switch chassis is designed to install in standard 19-inch equipment racks that meet ANSI/EIA 310-D, IEC 60297, and ETS 300-119 standards. Weight Chassis only: 27 lb (12.25 kg). Chassis fully configured with 2 supervisor engines, 2 modules, and 2 AC-input power supplies: 97 lb (43.99 kg). Airflow FAN-MOD-4HS—300 CFM NoteTo maintain proper air circulation through the Catalyst switch chassis, we recommend that you maintain a minimum 6-inch (15 cm) separation between a wall and the chassis air intake or a wall and the chassis air exhaust. You should also allow a minimum separation of 12 inches (30.5 cm) between the hot air exhaust on one chassis and the air intake on another chassis. Failure to maintain adequate air space can cause the chassis to overheat and the system to fail. On Catalyst chassis in which the airflow is from front to back, the chassis may be placed side-by-side. 1. RU = rack units Table 1-6 Catalyst 6504-E Switch Specifications (continued) Item Specification
1-18 Catalyst 6500 Series Switches Installation Guide OL-5781-08 Chapter 1 Product Overview Catalyst 6506 Switch Catalyst 6506 Switch The Catalyst 6506 switch is a 6-slot horizontal chassis supporting redundant power supplies, redundant supervisor engines, and slots for up to five modules. The chassis is NEBS L3 compliant. Figure 1-7 shows a front view of the Catalyst 6506 switch chassis. Figure 1-7 Catalyst 6506 Switch 18224 INPUT OKFA N OKOUTPUT FA I L o INPUT OKFA N OKOUTPUT FA I L o 1 2 3 FA N STATUS 4 5 68 P O R T G IG A B IT E TH E R N E TWS-X64081LINKSTA TUS2 3 4 56 7 8LINKLINKLINKLINKLINKLINKLINK 8 P O R T G IG A B IT E TH E R N E TWS-X64081LIN KSTA TUS2 3 4 5 6 7 8LI NKLINKLINKLIN KLI NKLI NKLI NK 8 P O R T G IG A B IT E TH E R N E TWS-X64081LIN KSTA TUS2 3 4 5 6 7 8LI NKLINKLINKLI N KLI NKLI NKLI NK 8 P O R T G IG A B IT E TH E R N E TWS-X64081LINKSTA TUS2 3 4 5 6 7 8LINKLINKLINKLINKLINKLINKLINKW S -S U P 32 -G E-3 BST AT U S SYSTEM ACT IV E PW R MGM T R ESETC ATA L Y S T 65 00 SUP ER V IS O R E N G IN E 3 2CONSOLE EJECTD ISK 0PORT 1 PORT 2 PORT 3 PORT 4PORT 5 POR T 6 PO RT 7PO RT 8POR T 9 USB 2.0 LIN K L INK L I NK LI NK LI NK LI NK LI NK LIN K LINKW S -S U P 32 -G E-3 BST AT U S SYSTEM ACT IVE PW R MG M T R ESETC AT A L Y S T 65 00 S UP ER V IS O R E N G IN E 3 2CONSOLE EJECTD ISK 0PORT 1 PORT 2 PORT 3 PORT 4PORT 5 PORT 6 PO RT 7PO RT 8POR T 9 USB 2. 0 LINK L IN K L I NK LI NK LI N K LI NK LI NK LINK LINK Fan assembly Supervisor engine Redundant supervisor engine Switching modules Power supply 2 (redundant)Power supply 1 ESD ground strap connector