    							A-21
    Catalyst 6500 Series Switches Installation Guide
    OL-5781-08
    Appendix A      Power Supply Specifications
      1400 W AC-Input Power Supply
    1400 W Power Supply AC Power Cords
    Ta b l e A - 1 6 lists the specifications for the AC power cords that are available for the 1400 W AC-input 
    power supply. These power cords plug into the 1400 W PEM (PEM-20A-AC+); not directly into the 
    power supply. The table includes references to power cord illustrations.
    NoteAll 1400 W power supply power cords are 14 feet (4.3 meters) in length.
    NoteAll 1400 W power supply power cords have an IEC60320/C19 appliance plug at one end.
    Table A-15 1400 W AC-Input Power Supply LEDs
    LED Meaning
    INPUT OK
    Green—Source AC voltage is OK. (Input voltage is 85 VAC or 
    greater.)
    Off—Source AC voltage falls below 70 VAC, is not present, or the 
    power supply is turned off.
    FAN OK
    Green—Power supply fan is operating properly. 
    Off—Power supply fan failure is detected.
    OUTPUT FAIL
    Red—Problem with one or more of the DC-output voltages of the 
    power supply is detected.
    DC-output voltages within acceptable margins.
    NoteFor proper operation of the OUTPUT FAIL LED, systems with 
    single power supplies must be configured with a minimum of 
    one fan tray and one supervisor engine. Systems with dual power 
    supplies must have a minimum configuration of one fan tray, one 
    supervisor engine, and one additional module. Failure to meet 
    these minimum configuration requirements can cause a false 
    power supply output fail signal. 
    						
    							A-22
    Catalyst 6500 Series Switches Installation Guide
    OL-5781-08
    Appendix A      Power Supply Specifications
      1400 W AC-Input Power Supply
    TableA-16 1400W Power Supply AC Power Cords
    Locale Power Cord
    Part NumberAC Source Plug Type Cordset Rating Power Cord 
    Reference 
    Illustration
    Argentina CAB-7513ACR=
    CAB-IR2073-C19-AR=IRAM 2073 16 A, 250 VACFigure A-31
    Australia, New Zealand CAB-7513ACA= SAA AS 3112 15 A, 250 VACFigure A-32
    People’s Republic of 
    ChinaCAB-AC16A-CH= GB16C 16 A, 250 VACFigure A-37
    Continental Europe CAB-7513ACE=
    CAB-AC-2500W-EU=CEE 7/7
    CEE 7/716 A, 250 VAC
    16 A, 250 VACFigure A-33
    Figure A-41
    International CAB-AC-2500W-INT= IEC 309 16 A, 250 VACFigure A-42
    Israel CAB-AC-2500W-ISRL= SI16S3 16 A, 250 VACFigure A-34
    Italy CAB-7513ACI= CEI 23-16/7 16 A, 250 VACFigure A-35
    Japan, North America CAB-7513AC=
    CAB-AC-2500W-US1=
    CAB-AC-C6K-TWLK=NEMA 5-20
    1
    NEMA 6-202
    NEMA L6-203
    1. For operation in Japan, ask your local electrical contractor to prepare the NEMA 5-20 power plug.
    2. For operation in Japan, ask your local electrical contractor to prepare the NEMA 6-20 power plug.
    3. For operation in Japan, ask your local electrical contractor to prepare the NEMA L6-20 power plug.
    20 A, 125 VAC
    16 A, 250 VAC
    16 A, 250 VACFigure A-36
    Figure A-43
    Figure A-44
    South Africa CAB-7513ACSA= IEC 884-1 16 A, 250 VACFigure A-38
    Switzerland CAB-ACS-10= SEV 1011 10 A, 250 VACFigure A-39
    Switzerland CAB-ACS-16= SEV 5934-2 Type 23 16 A, 250 VACFigure A-45
    United Kingdom CAB-7513ACU= BS 1363 13 A, 250 VAC
    4
    4. Plug contains a 13 A fuse.
    Figure A-40
    Power Distribution Unit 
    (PDU)
    5
    5. The PDU power cable is designed for users who power their switch from a PDU. The end of the cable that plugs into the chassis power supply has 
    a C19 connector; the other end of the cable that connects to the PDU has a C20 connector.
    CAB-C19-CBN= IEC 60320 C19
    IEC 60320 C2016 A, 250 VACFigure A-47 
    						
    							A-23
    Catalyst 6500 Series Switches Installation Guide
    OL-5781-08
    Appendix A      Power Supply Specifications
      2500 W AC-Input and DC-Input Power Supplies
    2500 W AC-Input and DC-Input Power Supplies 
    The 2500 W AC-input power supply (WS-CAC-2500W) and 2500 W DC-input power supply 
    (WS-CDC-2500W) are supported in the following Catalyst 6500 series switches:
    Catalyst 6506
    Catalyst 6506-E
    Catalyst 6509
    Catalyst 6509-E
    Catalyst 6509-NEB
    Catalyst 6509-NEB-A
    Catalyst 6509-V-E
    Catalyst 6513
    Catalyst 6513-E (DC-input power supply only)
    The 2500 W power supplies, shown in Figure A-9 and Figure A-10, share the same form factor as the 
    1000 W, 1300 W, 3000 W, 4000 W, and 6000 W AC-input power supplies.
    NoteWith a fully populated Catalyst 6513 switch, two 2500 W power supplies are not fully redundant. If you 
    operate the 2500 W power supply at the low range input (100 to 120 VAC), it is not redundant in a fully 
    populated Catalyst 6509, Catalyst 6509-E, Catalyst 6509-NEB, Catalyst 6509-NEB-A, or 
    Catalyst 6509-V-E switch.
    NoteThe 2500 W AC-input power supply needs 220 VAC to deliver 2500 W of power. When powered with 
    110 VAC, it delivers only 1300 W. In addition, the power supply needs 16 A, regardless of whether it is 
    plugged into 110 VAC or 220 VAC.
    Figure A-9 2500 W AC-Input Power Supply
    Power
    switchCable 
    retention
    deviceAC power
    connectionINPUT
    O
    KFA N
    OKOUTPUT
    FAIL
    Captive installation
    screwStatus LEDs
    16029I
    0 
    						
    							A-24
    Catalyst 6500 Series Switches Installation Guide
    OL-5781-08
    Appendix A      Power Supply Specifications
      2500 W AC-Input and DC-Input Power Supplies
    Figure A-10 2500 W DC-input Power Supply
    2500 W Power Supply Specifications
    Ta b l e A - 1 7 lists the specifications for the 2500 W AC-input and DC-input power supplies.
    Terminal
    block
    cover
    Captive installation screw
    o
    16030
    INPU
    T
    OKFA N
    OKO
    UTP
    UT
    FAIL
    Table A-17 2500 W AC-Input Power Supply Specifications
    Specification Description
    AC-input type Autoranging input with power factor correction (PFC).
    NotePower factor correction is a standard feature on all Catalyst 6500 
    series AC-input power supplies. PFC reduces the reactive 
    component in the source AC current allowing higher power 
    factors (typically 99 percent or better) and lower harmonic 
    current components.
    AC-input voltage
    Low-line (120 VAC nominal)—90 VAC (min) to 132 VAC (max)
    High-line (230 VAC nominal)—170 VAC (min) to 264 VAC (max)
    AC-input current 16 A maximum at 230 VAC at 2500 W output
    16 A maximum at 120 VAC at 1300 W output
    AC-input frequency 50/60 Hz (nominal) (±3% for full range) 
    						
    							A-25
    Catalyst 6500 Series Switches Installation Guide
    OL-5781-08
    Appendix A      Power Supply Specifications
      2500 W AC-Input and DC-Input Power Supplies
    Ta b l e A - 1 8 lists the specifications for the 2500 W DC-input power supply. Branch circuit requirement Each chassis power supply should have its own dedicated, fused-branch 
    circuit:
    For North America—20 A
    For International—Circuits sized to local and national codes
    All AC power supply inputs are fully isolated.
    –Source AC can be out of phase between multiple power supplies 
    in the same chassis, which means that PS1 can be operating 
    from phase A and PS2 can be operating from phase B.
    –For high-line operation, the power supply operates with the hot 
    conductor wired to a source AC phase and the neutral conductor 
    wired either to ground or to another source AC phase as long as 
    the net input voltage is in the range of 170 to 264 VAC.
    –Source AC can be out of phase between AC inputs on power 
    supplies that are equipped with multiple AC inputs, which 
    means that power cord 1 can be plugged into phase A and 
    power cord 2 can be plugged into phase B.
    Power supply output 
    capacity
    1300 W maximum (100–120 VAC)
    2500 W maximum (200–240 VAC)
    Power supply output 
    100/120 VAC operation
    –15.5 A @ +3.3 VDC
    –5A @ +5VDC
    –10 A @ +12 VDC
    –27.5 A @ +42 VDC
    200/240 VAC operation
    –15 A @ +3.3 VDC
    –5A @ +5VDC
    –10 A @ +12 VDC
    –55.5 A @ +42 VDC
    Output holdup time 20 ms minimum
    kVA rating
    13520 W (total input power) or 3.6 KVA (high-line operation)
    Heat dissipation 10,939 BTU/hour (approx.) 
    Weight 17.0 lb (7.7 kg)
    1. The kVA rating listed for the power supply should be used as the sizing criteria for both UPS outputs as well as standard 
    circuits and transformers to power a switch.
    Table A-17 2500 W AC-Input Power Supply Specifications (continued)
    Specification Description 
    						
    							A-26
    Catalyst 6500 Series Switches Installation Guide
    OL-5781-08
    Appendix A      Power Supply Specifications
      2500 W AC-Input and DC-Input Power Supplies
    Ta b l e A - 1 9 lists the power supply LEDs and their meanings.
    Table A-18 2500 W DC-Input Power Supply Specifications
    Specification Description
    DC-input voltage  North America: –48 VDC (nominal) (–40.5 VDC to –56 VDC) 
    International: –60 VDC (nominal) (–55 VDC to –72 VDC)
    DC-input current
    70 A @ –48 VDC
    55 A @ –60 VDC
    Power supply output 
    capacity2500 W maximum (–48 to –60 VDC)
    Power supply output 
    15 A @ +3.3 VDC
    5A @ +5VDC
    10 A @ +12 VDC
    55.5A @ +42VDC
    DC input terminal block Accepts 2–14 AWG copper conductors. Actual size of the wire needed 
    is determined by the installer or local electrician. Terminal block 
    material rated at 150°C.
    Output holdup time
    20 ms minimum (AC-input power supply)
    4 ms (DC-input power supply)
    Heat dissipation
    10,939 BTU/hour (approx.) AC-input power supply
    11,377 BTU/hour (approx.) DC-input power supply
    Weight 20.2 lb (9.2 kg) 
    						
    							A-27
    Catalyst 6500 Series Switches Installation Guide
    OL-5781-08
    Appendix A      Power Supply Specifications
      2500 W AC-Input and DC-Input Power Supplies
    Table A-19 2500 W AC-Input and DC-Input Power Supply LEDs
    LED Meaning
    INPUT OK AC-input power supplies:
    Green—Source AC voltage is OK. (Input voltage is 85 VAC or 
    greater.)
    Off—Source AC voltage falls below 70 VAC, is not present, or the 
    power supply is turned off.
    DC-input power supplies:
    Green—Source DC voltage is OK. (Input voltage is –40.5 VDC or 
    greater.)
    Off—Source DC voltage falls below –33 VDC, is not present, or the 
    power supply is turned off.
    FAN OK
    Green—Power supply fan is operating properly.
    Off—Power supply fan failure is detected.
    OUTPUT FAIL
    Red—Problem with one or more of the DC-output voltages of the 
    power supply.
    Off—DC-output voltages within acceptable margins.
    NoteFor proper operation of the OUTPUT FAIL LED, systems with 
    single power supplies must be configured with a minimum of 
    one fan tray and one supervisor engine. Systems with dual power 
    supplies must have a minimum configuration of one fan tray, one 
    supervisor engine, and one additional module. Failure to meet 
    these minimum configuration requirements can cause a false 
    power supply output fail signal. 
    						
    							A-28
    Catalyst 6500 Series Switches Installation Guide
    OL-5781-08
    Appendix A      Power Supply Specifications
      2500 W AC-Input and DC-Input Power Supplies
    2500 W Power Supply AC Power Cords
    Ta b l e A - 2 0 lists the specifications for the AC power cords that are available for the 2500 W AC-input 
    power supply. The table includes references to power cord illustrations.
    NoteAll 2500 W power supply power cords are 14 feet (4.3 meters) in length.
    NoteAll 2500 W power supply power cords have an IEC60320/C19 appliance connector at one end. 
    TableA-20 2500W Power Supply AC Power Cords
    Locale Power Cord
    Part NumberAC Source Plug Type Cordset Rating Power Cord 
    Reference 
    Illustration
    Argentina CAB-7513ACR= or 
    CAB-IR2073-C19-AR=IRAM 2073 16 A, 250 VACFigure A-31
    Australia, New Zealand CAB-AC-16A-AUS= AU20S3 16 A, 250 VACFigure A-46
    People’s Republic of China CAB-AC16A-CH= GB16C 16 A, 250 VACFigure A-37
    Continental Europe CAB-AC-2500W-EU= CEE 7/7 16 A, 250 VACFigure A-41
    International CAB-AC-2500W-INT= IEC 309 16 A, 250 VACFigure A-42
    Israel CAB-AC-2500W-ISRL= SI16S3 16 A, 250 VACFigure A-34
    Japan, North America 
    200–240 VAC operationCAB-AC-2500W-US1= NEMA 6-20
    (nonlocking plug)16 A, 250 VACFigure A-43
    Japan, North America 
    200–240 VAC operationCAB-AC-C6K-TWLK= NEMA L6-20
    (locking plug)16 A, 250 VACFigure A-44
    Japan, North America
    100–120 VAC operation
    1
    1. The 2500 W power supply operating on 110 VAC delivers 1300 W.
    CAB-7513AC= NEMA 5-20 20 A, 125 VACFigure A-36
    Power Distribution Unit 
    (PDU)
    2
    2. The PDU power cable is designed for users who power their switch from a PDU. The end of the cable that plugs into the chassis power supply has a 
    C19 connector; the other end of the cable that connects to the PDU has a C20 connector.
    CAB-C19-CBN IEC 60320 C19
    IEC 60320 C2016 A, 250 VACFigure A-47
    Switzerland CAB-ACS-16= SEV 5934-2 Type 23 16 A, 250 VACFigure A-45 
    						
    							A-29
    Catalyst 6500 Series Switches Installation Guide
    OL-5781-08
    Appendix A      Power Supply Specifications
      2700 W AC-Input and DC-Input Power Supplies
    2700 W AC-Input and DC-Input Power Supplies
    The 2700 W AC-input power supply (PWR-2700-AC/4) and 2700 W DC-input power supply 
    (PWR-2700-DC/4) are supported only in the Catalyst 6504-E switch. See Figure A-11 for the 2700 W 
    AC-input power supply and Figure A-12 for the 2700 W DC-input power supply.
    NoteThe 2700 W AC-input power supply needs 220 VAC to deliver 2700 W of power. When powered with 
    110 VAC, it delivers only 1350 W. In addition, the power supply needs 16 A, regardless of whether it is 
    plugged into 110 VAC or 220 VAC.
    Figure A-11 2700 W AC-Input Power Supply
    1Power on/off switch (|/O)4Status LEDs
    2Power supply fan5AC In receptacle
    3Captive installation screw (4x)
    154028ALL FASTENERS MUST BE FULLY ENGAGED
    PRIOR TO OPERATING THE POWER SUPPLY
    PWR-2700-AC/4
    1
    2
    4
    5
    3
    3 
    						
    							A-30
    Catalyst 6500 Series Switches Installation Guide
    OL-5781-08
    Appendix A      Power Supply Specifications
      2700 W AC-Input and DC-Input Power Supplies
    Figure A-12 2700 W DC-Input Power Supply
    1Captive installation screw (4x)7Fixed cable guide, top half
    2Source DC terminal block8Detached cable guide, bottom half
    3Status LEDs 9Tie-wrap (for source DC cables)
    4Terminal block cover10Fixed cable guide, bottom half
    5Detached cable guide, top half11Tie-wrap (for ground cable)
    6Ground terminal block
    132219
    PWR-2700-DC/4
    -VE-1
    -VE-1
    -VE-2
    -VE-2IN
    P
    U
    T1
    O
    K
    4
    8V
    -60V
    =40AIN
    PU
    T
    2
    O
    K
    48V
    -60V
    =4
    0AFA
    N
    O
    KO
    U
    TPU
    T
    FA
    IL
    ALL FASTENERS MUST BE F
    ULLY ENGAG
    ED
    PRIOR TO O
    PERATING THE POW
    ER SUPPLY
    32
    6
    4
    10
    1
    8
    57
    119 
    						
    All Cisco manuals Comments (0)

    Related Manuals for Cisco 6500e Manual