Home > Cisco > Ethernet Switch > Cisco 6500e Manual

Cisco 6500e Manual

    Download as PDF Print this page Share this page

    Have a look at the manual Cisco 6500e Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 53 Cisco manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.

    Page
    of 454
    							Catalyst 6500 Series Switches Installation Guide
    OL-5781-08
    APPENDIX
    A
    Chassis and Module Power and Heat Values
    This appendix provides the power and heat numbers for the Catalyst 6500 series chassis and modules. The following power 
    requirements and heat dissipation tables are provided:
    Chassis and fan trays—Ta b l e A - 1
    IP phones—Ta b l e A - 2
    Supervisor engines—Ta b l e A - 3
    Policy Feature Cards (PFCs)—Ta b l e A - 4
    Distributed Forwarding Cards (DFCs)—Ta b l e A - 5
    Switch fabric modules—Ta b l e A - 6
    10-Gigabit Ethernet modules—Ta b l e A - 7
    40-Gigabit Ethernet modules—Ta b l e A - 8
    Gigabit Ethernet modules—Ta b l e A - 9
    10/100/1000 Ethernet modules—Ta b l e A - 1 0
    Fast Ethernet switching modules—Ta b l e A - 1 1
    10/100 Ethernet switching modules—Ta b l e A - 1 2
    10BASE Ethernet switching modules—Ta b l e A - 1 3
    FlexWAN and Enhanced FlexWAN modules—Ta b l e A - 1 4
    Service modules—Ta b l e A - 1 5
    Miscellaneous modules—Ta b l e A - 1 6
    Unless otherwise noted, the information in the following tables is measured under fully loaded conditions (transceivers 
    installed). Typical numbers are approximately 20 percent below the numbers listed in these tables.
    NoteModule power is the output from the power supply (internal to the system). The AC-input power is the 
    input from the outlet to the power supply. The percentage difference between the two values is the 
    efficiency of the power supply. 
    						
    							A
    Catalyst 6500 Series Switches Installation Guide
    OL-5781-08
    Appendix A      Chassis and Module Power and Heat Values
      
    Table A-1 Power Requirements and Heat Dissipation—Chassis and Fan Trays
    Model Number/
    Module TypeModule 
    Current (A)Module 
    Power 
    (Watts)AC DC
    AC-Input
    Power 
    (Watts)Heat Diss.
    (BTU/HR)DC-Input
    Power 
    (Watts)Heat Diss.
    (BTU/HR)
    Catalyst 6503 chassis
    FAN-MOD-3 fan tray 0.80 34.00 43.00 145.00 46.00 156.00
    FAN-MOD-3HS fan tray 2.98 125.16 156.45 534.28 168.23 574.49
    Catalyst 6503-E chassis
    WS-C6503-E-FAN fan tray
    11.37
    3.1057.54
    130.2071.93
    162.75245.62
    555.7977.34
    175.00264.11
    597.63
    Catalyst 6504-E chassis
    FA N - M O D - 4 H S  f a n  t r a y
    11.43
    2.1760.06
    91.1475.08
    113.93256.38
    389.0580.73
    122.50275.68
    418.34
    Catalyst 6506 chassis 
    WS-C6K-6SLOT-FAN fan tray 0.71 30.00 37.48 128.00 40.00 136.88
    WS-C6K-6SLOT-FAN2 fan tray 2.00 84.00 105.00 359.00 113.00 386.00
    Catalyst 6506-E chassis
    WS-C6506-E-FAN fan tray
    12.35
    3.3598.70
    140.70123.40
    175.88421.33
    600.61132.66
    189.11453.04
    645.82
    Catalyst 6509 chassis 
    WS-C6K-9SLOT-FAN fan tray 1.10 46.00 58.00 196.00 62.00 212.00
    WS-C6K-9SLOT-FAN2 fan tray 3.04 127.68 159.60 545.03 171.70 586.06
    Catalyst 6509-E chassis
    WS-C6509-E-FAN fan tray
    13.58
    5.00150.36
    210.00187.95
    262.50641.85
    896.44202.10
    282.26690.16
    963.91
    Catalyst 6509-NEB chassis
    WS-C6K-NEB-FAN fan tray 7.00 294.00 368.00 1255.00 395.00 1349.00 
    						
    							Catalyst 6500 Series Switches Installation Guide
    OL-5781-08
    Appendix A      Chassis and Module Power and Heat Values
      
    Catalyst 6509-NEB-A chassis
    FA N - M O D - 0 9
    2 fan tray 5.75 242.00 302.00 1031.00 325.00 1108.00
    Catalyst 6509-V-E chassis
    3
    WS-C6509-V-E-FAN fan tray 5.75 242.00 302.00 1031.00 325.00 1108.00
    Catalyst 6513 chassis
    WS-C6K-13SLOT-FAN fan tray 1.58 73.00 146.00 499.00 157.00 536.00
    WS-C6K-13SLOT-FAN2 fan tray 7.10 298.20 372.75 1272.94 400.81 1368.75
    Catalyst 6513-E chassis
    WS-C6513-E-FAN 7.10 298.20 372.75 1272.94 400.81 1368.75
    1. Two sets of values are given for these fan trays. The Catalyst 6500-E series fan trays are designed to provide two levels of cooling. The lower 
    set of values shown are for chassis where modules that do not require the additional cooling capacity are installed. The higher set of values shown 
    are for chassis where modules that require additional cooling capacity are installed - they have been called out in the corresponding tables below. 
    2. Values given are per fan tray. The Catalyst 6509-NEB-A switch chassis ships with one fan tray installed by default. A second fan tray can be 
    installed in the chassis. The power and heat numbers for a chassis equipped with two fan trays are double the values listed.
    3. Values given are per fan tray. The Catalyst 6509-V-E switch chassis ships with one fan tray installed by default. A second fan tray can be installed 
    in the chassis. The power and heat numbers for a chassis equipped with two fan trays are double the values listed.
    Table A-2 Power Requirements and Heat Dissipation—IP Phones
    Model Number/
    Module TypeModule 
    Current (A)Module 
    Power 
    (Watts)AC DC
    AC-Input
    Power 
    (Watts)Heat Diss.
    (BTU/HR)DC-Input
    Power 
    (Watts)Heat Diss.
    (BTU/HR)
    Cisco IP Phone 7960 0.15 6.3 7.88 26.89 8.47 28.92
    Cisco IP Phone 7940 0.15 6.3 7.88 26.89 8.47 28.92
    Cisco IP Phone 7910 0.13 5.46 6.83 23.31 7.34 25.06
    Table A-1 Power Requirements and Heat Dissipation—Chassis and Fan Trays (continued)
    Model Number/
    Module TypeModule 
    Current (A)Module 
    Power 
    (Watts)AC DC
    AC-Input
    Power 
    (Watts)Heat Diss.
    (BTU/HR)DC-Input
    Power 
    (Watts)Heat Diss.
    (BTU/HR) 
    						
    							A
    Catalyst 6500 Series Switches Installation Guide
    OL-5781-08
    Appendix A      Chassis and Module Power and Heat Values
      
    The module power values are based on 42 VDC. Power is distributed to each slot in the chassis from the power supply’s 
    42 VDC output. Each module has DC-to-DC power supplies that convert the 42 VDC into +2.5 VDC, +3.3 VDC, and +5 VDC 
    to power the module. The 42 VDC is independent of the power supply’s input voltage, either 110 VAC or 220 VAC.
    Ta b l e A - 3 lists the power and the heat numbers for the supervisor engines.
    Table A-3 Power Requirements and Heat Dissipation—Supervisor Engines
    Model Number/
    Module TypeModule 
    Current (A) 
    @ 42 VDCModule 
    Power 
    (Watts)AC DC
    AC-Input
    Power 
    (Watts)Heat Diss.
    (BTU/HR)DC-Input
    Power 
    (Watts)Heat Diss.
    (BTU/HR)
    WS-X6K-SUP1A-2GE
    Supervisor Engine 1A1.70 71.40 89.25 304.79 95.97 327.73
    WS-X6K-SUP1A-PFC
    Supervisor Engine 1A with PFC 
    daughter card2.50 105 131.25 448.22 141.13 481.96
    WS-X6K-SUP1A-MSFC
    Supervisor Engine 1A with PFC 
    and MSFC daughter cards3.30 138.60 173.25 519.65 186.29 559.18
    WS-X6K-SUP1A-MSFC2
    Supervisor Engine 1A with PFC 
    and MSFC2 daughter cards2.90 121.80 152.25 519.93 163.71 559.07
    WS-X6K-S2-PFC2
    Supervisor Engine 2 with PFC2 
    daughter card3.06 128.52 160.65 548.62 172.74 589.91
    WS-X6K-S2-MSFC2
    Supervisor Engine 2 with PFC2 
    and MSFC2 daughter cards3.46 145.32 181.65 620.33 195.32 667.03
    WS-X6K-S2U-MSFC2
    Supervisor Engine 2 with PFC2 
    and MSFC2 daughter 
    cards—Has 512 MB of DRAM3.46 145.32 181.65 620.33 195.32 667.03 
    						
    							Catalyst 6500 Series Switches Installation Guide
    OL-5781-08
    Appendix A      Chassis and Module Power and Heat Values
      
    Model Number/
    Module TypeModule 
    Current (A) 
    @ 42 VDCModule 
    Power 
    (Watts)AC DC
    AC-Input
    Power 
    (Watts)Heat Diss.
    (BTU/HR)DC-Input
    Power 
    (Watts)Heat Diss.
    (BTU/HR)
    WS-SUP32-10GE-3B
    Supervisor Engine 32 with 
    PFC3B and MSFC2A daughter 
    cards 4.19 175.98 219.98 751.21 236.53 807.76
    WS-SUP32-GE-3B
    Supervisor Engine 32 with 
    PFC3B and MSFC2A daughter 
    cards 3.69 154.98 193.73 661.57 208.31 711.37
    WS-S32-GE-PISA
    Supervisor Engine 32 with 
    PFC3B and Programmable IP 
    Services Accelerator (PISA) 
    daughter cards. 2.96 124.32 155.40 530.69 167.10 570.64
    WS-S32-10GE-PISA
    Supervisor Engine 32 with 
    PFC3B and Programmable IP 
    Services Accelerator (PISA) 
    daughter cards2.97 124.74 155.93 532.48 167.66 572.56
    WS-SUP720
    Supervisor Engine 720 with 
    PFC3A daughter card and 
    integrated MSFC3 and switch 
    fabric7.50 315.0 393.75 1344.66 423.39 1445.87
    WS-SUP720-3B 
    Supervisor Engine 720 with 
    PFC3B daughter card and 
    integrated MSFC3 and switch 
    fabric6.72 282.24 350.80 1204.81 379.35 1295.5
    WS-SUP720-3BXL
    Supervisor Engine 720 with 
    PFC3BXL daughter card and 
    integrated MSFC3 and switch 
    fabric7.82 328.44 410.55 1402.03 441.45 1507.56
    VS-S720-10G-3C
    Supervisor Engine 720-10GE 
    with PFC3C daughter card and 
    integrated MSFC3 and switch 
    fabric8.05 338.10 422.63 1443.26 454.44 1551.90
    VS-S720-10G-3CXL
    Supervisor Engine 720-10GE 
    with PFC3CXL daughter card 
    and integrated MSFC3 and 
    switch fabric8.65 363.30 454.13 1550.84 488.31 1667.57
    Table A-3 Power Requirements and Heat Dissipation—Supervisor Engines (continued) 
    						
    							A
    Catalyst 6500 Series Switches Installation Guide
    OL-5781-08
    Appendix A      Chassis and Module Power and Heat Values
      
    Ta b l e A - 4 lists the power and the heat numbers for the Policy Feature Cards (PFCs).
    Ta b l e A - 5 lists the power and the heat numbers for the Distributed Forwarding Cards (DFCs).
    Table A-4 Power Requirements and Heat Dissipation—Policy Feature Cards (PFCs)
    Model Number/
    Module TypeModule 
    Current (A)Module 
    Power 
    (Watts)AC DC
    AC-Input
    Power 
    (Watts)Heat Diss.
    (BTU/HR)DC-Input
    Power 
    (Watts)Heat Diss.
    (BTU/HR)
    WS-F6K-PFC3A
    Policy Feature Card 3A2.25 94.50 118.13 403.40 127.02 433.76
    WS-F6K-PFC3B
    Policy Feature Card 3B1.47 61.74 77.18 263.55 82.98 283.39
    WS-F6K-PFC3BXL
    Policy Feature Card 3BXL2.57 107.94 134.93 460.77 145.08 495.45
    VS-F6K-PFC3C
    Policy Feature Card 3C1.90 79.80 99.75 340.65 107.26 366.29
    VS-F6K-PFC3CXL
    Policy Feature Card 3CXL2.50 105.00 131.25 448.22 141.13 481.96
    Table A-5 Power Requirements and Heat Dissipation—Distributed Forwarding Cards (DFCs)
    Model Number/
    Module TypeModule 
    Current (A)Module 
    Power 
    (Watts)AC DC
    AC-Input
    Power 
    (Watts)Heat Diss.
    (BTU/HR)DC-Input
    Power 
    (Watts)Heat Diss.
    (BTU/HR)
    WS-F6K-DFC
    Distributed Forwarding Card2.10 88.20 110.25 376.50 118.55 404.84
    WS-F6K-DFC3A
    Distributed Forwarding Card 3A2.57 107.94 134.93 460.77 145.08 495.45
    WS-F6K-DFC3B
    Distributed Forwarding Card 3B1.67 70.14 87.68 299.41 94.27 321.95
    WS-F6K-DFC3BXL
    Distributed Forwarding 
    Card 3BXL2.38 99.96 124.95 426.70 134.35 458.82
    WS-F6700-CFC
    Centralized Forwarding Card0.75 31.5 39.38 134.47 42.34 144.59 
    						
    							Catalyst 6500 Series Switches Installation Guide
    OL-5781-08
    Appendix A      Chassis and Module Power and Heat Values
      
    Ta b l e A - 6 lists the power and the heat numbers for the switch fabric modules. WS-F6700-DFC3A
    Distributed Forwarding Card 3A3.0 126 157.5 537.86 169.35 578.35
    WS-F6700-DFC3B
    Distributed Forwarding Card 3B2.7 113.40 141.75 484.08 152.42 520.51
    WS-F6700-DFC3BXL
    Distributed Forwarding 
    Card 3BXL3.3 138.60 173.25 591.65 186.29 636.18
    WS-F6700-DFC3C
    Distributed Forwarding Card 3C 
    for use on CEF720 modules. 
    Supported only with Supervisor 
    Engine 720 and Supervisor 
    Engine 720-10GE1.65 69.30 86.63 295.82 93.15 318.09
    WS-F6700-DFC3CXL
    Distributed Forwarding 
    Card 3CXL for use on CEF720 
    modules. Supported only with 
    Supervisor Engine 720 and 
    Supervisor Engine 720-10GE.2.35 98.70 123.38 421.33 132.66 453.04
    Table A-6 Power Requirements and Heat Dissipation—Switch Fabric Modules
    Model Number/
    Module TypeModule 
    Current (A)Module 
    Power 
    (Watts)AC DC
    AC-Input
    Power 
    (Watts)Heat Diss.
    (BTU/HR)DC-Input
    Power 
    (Watts)Heat Diss.
    (BTU/HR)
    WS-C6500-SFM
    Switch Fabric Module2.79 117.18 146.5 500.2 157.5 537.86
    WS-X6500-SFM2
    Switch Fabric Module 23.09 129.78 162.23 554 174.4 595.7
    Table A-5 Power Requirements and Heat Dissipation—Distributed Forwarding Cards (DFCs) (continued)
    Model Number/
    Module TypeModule 
    Current (A)Module 
    Power 
    (Watts)AC DC
    AC-Input
    Power 
    (Watts)Heat Diss.
    (BTU/HR)DC-Input
    Power 
    (Watts)Heat Diss.
    (BTU/HR) 
    						
    							A
    Catalyst 6500 Series Switches Installation Guide
    OL-5781-08
    Appendix A      Chassis and Module Power and Heat Values
      
    Ta b l e A - 7 lists the power and the heat numbers for the 10-Gigabit Ethernet modules.
    NoteFor the WS-X6502-10GE and WS-X6704-10GE Ethernet modules, the values shown are for the 
    baseboard only. When the baseboard has a CFC or DFC3 daughter card installed, you must add the 
    daughter card power to the baseboard power to get the total slot power. For the WS-X6708-10G-3C, 
    WS-X6708-10G-3CXL, WS-X6716-10G-3C , and the WS-X6716-10G-3CXL Ethernet modules, the 
    values shown include the factory installed WS-F6700-DFC3C or WS-F6700-DFC3CXL daughter cards.
    Table A-7 Power Requirements and Heat Dissipation—10-Gigabit Ethernet Modules
    Model Number/
    Module TypeModule 
    Current (A)Module 
    Power 
    (Watts)AC DC
    AC-Input
    Power 
    (Watts)Heat Diss.
    (BTU/HR)DC-Input
    Power 
    (Watts)Heat Diss.
    (BTU/HR)
    WS-X6502-10GE
    2-port 10-Gigabit Ethernet module3.30 138.60 173.25 591.65 186.29 636.18
    WS-X6704-10GE
    4-Port 10-Gigabit Ethernet module6.28 263.76 329.70 1125.93 354.52 1210.67
    WS-X6708-10G-3C
    8-Port 10-Gigabit Ethernet module with 
    WS-F6700-DFC3C daughter card. 
    Requires additional cooling. See footnote
    1.10.58 444.36 555.45 1896.86 600.49 2050.66
    WS-X6708-10G-3CXL
    8-Port 10-Gigabit Ethernet module with 
    WS-F6700-DFC3CXL daughter card.
    Requires additional cooling. See footnote
    1.11.28 473.76 592.20 2022.36 640.22 2186.34
    WS-X6716-10G-3C
    16-Port 10-Gigabit Ethernet module with 
    WS-F6700-DFC3C daughter card.
    Requires additional cooling. See footnote
    1.10.90 457.80 572.25 1954.23 615.32 2101.33
    WS-X6716-10G-3CXL
    16-Port 10-Gigabit Ethernet module with 
    WS-F6700-DFC3CXL daughter card.
    Requires additional cooling. See footnote
    1.11.60 487.20 609.00 2079.74 654.84 2236.27
    WS-X6716-10T-3C
    16-Port 10-Gigabit Ethernet module with 
    WS-F6700-DFC3C daughter card.11.53 484.26 605.33 2067.18 650.89 2222.78
    WS-X6716-10T-3CXL
    16-Port 10-Gigabit Ethernet module with 
    WS-F6700-DFC3CXL daughter card.12.23 513.66 642.08 2192.69 690.40 2357.73
    WS-X6908-10G-2T
    8-Port 10-Gigabit Ethernet module with 
    WS-F6K-DFC4-E daughter card.
    Requires additional cooling. See footnote
    1.14.00 488.0 610.05 2083.32 655.97 2240.13 
    						
    							Catalyst 6500 Series Switches Installation Guide
    OL-5781-08
    Appendix A      Chassis and Module Power and Heat Values
      
    WS-X6908-10G-2TXL
    8-Port 10-Gigabit Ethernet module with 
    WS-F6K-DFC4-EXL daughter card.
    Requires additional cooling. See footnote
    1.17.03 715.26 894.08 3053.27 961.37 3283.08 
    C6800-32P10G/C6800-32P10G-XL
    32-Port 10-Gigabit Ethernet module with 
    WS-F6K-DFC4-E/WS-F6K-DFC4-EXL 
    daughter card.
    Requires additional cooling. See footnote
    1.14
    1588 588 2006.33 588 2006.33 
    C6800-16P10G/C6800-16P10G-XL
    16-Port 10-Gigabit Ethernet modules with 
    WS-F6K-DFC4-E/WS-F6K-DFC4-EXL 
    daughter card.
    Requires additional cooling. See footnote
    1.8.5
    1 357 357 1218.13 357 1218.13 
    C6800-8P10G or C6800-8P10G-XL
    8-Port 10-Gigabit Ethernet modules with 
    WS-F6K-DFC4-E/WS-F6K-DFC4-EXL 
    daughter card.
    Requires additional cooling. See footnote
    1.8.5
    1357 357 1218.13 357 1218.13
    1. On a Cisco Catalyst 6503-E and 6504-E module current is @50V; On all other Cisco Catalyst 6500-E Series switches, module current is @ 42V. 
    Table A-7 Power Requirements and Heat Dissipation—10-Gigabit Ethernet Modules (continued)
    Model Number/
    Module TypeModule 
    Current (A)Module 
    Power 
    (Watts)AC DC
    AC-Input
    Power 
    (Watts)Heat Diss.
    (BTU/HR)DC-Input
    Power 
    (Watts)Heat Diss.
    (BTU/HR) 
    						
    							A
    Catalyst 6500 Series Switches Installation Guide
    OL-5781-08
    Appendix A      Chassis and Module Power and Heat Values
      
    Ta b l e A - 8 lists the power and the heat numbers for the 40-Gigabit Ethernet modules.
    Ta b l e A - 9 lists the power and the heat numbers for the Gigabit Ethernet modules.
    Table A-8 Power Requirements and Heat Dissipation—40-Gigabit Ethernet Modules
    Model Number/Module TypeModule 
    Current 
    (A)Module 
    Power 
    (Watts)AC DC
    AC-Input
    Power 
    (Watts)Heat Diss.
    (BTU/HR)DC-Input
    Power 
    (Watts)Heat Diss.
    (BTU/HR)
    WS-X6904-40G-2T
    4-Port 10-Gigabit Ethernet module with 
    WS-F6K-DFC4-E daughter card.
    Requires additional cooling. See footnote
    1.16.67 700.14 875.18 2988.72 941.05 3213.68
    WS-X6904-40G-2TXL
    4-Port 10-Gigabit Ethernet module with 
    WS-F6K-DFC4-EXL daughter card.
    Requires additional cooling. See footnote
    1.17.03 715.26 894.08 3053.27 961.37 3283.08
    Table A-9 Power Requirements and Heat Dissipation—Gigabit Ethernet Modules
    Model Number/Module TypeModule 
    Current (A)Module 
    Power 
    (Watts)AC DC
    AC-Input
    Power 
    (Watts)Heat Diss.
    (BTU/HR)DC-Input
    Power 
    (Watts)Heat Diss.
    (BTU/HR)
    WS-X6316-GE-TX
    16-port 1000BASE-T Gigabit 
    Ethernet module5.15 216.3 270.38 923.33 290.73 992.83
    WS-X6408A-GBIC
    8-port 1000BASE-X Gigabit 
    Ethernet module2.00 84.00 105.00 358.58 112.90 385.56
    WS-X6416-GBIC
    16-port 1000BASE-X Gigabit 
    Ethernet module2.81 118.02 147.53 503.8 158.63 541.72
    WS-X6416-GE-MT
    8-port 1000BASE-SX Gigabit 
    Ethernet module2.50 105.00 131.25 448.22 141.13 481.96
    WS-X6516-GBIC
    16-port 1000BASE-X Gigabit 
    Ethernet module3.40 142.80 178.50 609.58 191.94 655.46
    WS-X6516A-GBIC
    16-port 1000BASE-X Gigabit 
    Ethernet module3.62 152.04 190.05 649.02 204.35 697.87
    WS-X6724-SFP
    24-Port 1000BASE-X Ethernet 
    module2.23 99.66 117.08 399.81 125.89 429.90 
    						
    All Cisco manuals Comments (0)