Cisco 6500e Manual
Have a look at the manual Cisco 6500e Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 53 Cisco manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.
A-11 Catalyst 6500 Series Switches Installation Guide OL-5781-08 Appendix A Power Supply Specifications 1000 W AC-Input Power Supply 1000 W Power Supply Specifications Ta b l e A - 7 lists the specifications for the 1000 W AC-input power supply. Table A-7 1000 W Power Supply Specifications Specification Description AC-input type Autoranging input with power factor correction (PFC) NotePower factor correction is a standard feature on all Catalyst 6500 series AC-input power supplies. PFC reduces the reactive component in the source AC current allowing higher power factors (typically 99 percent or better) and lower harmonic current components. AC-input voltage Low-line (120 VAC nominal)—90 VAC (min) to 132 VAC (max) High-line (230 VAC nominal)—170 VAC (min) to 264 VAC (max) AC-input current 12 A @ 120 VAC 6 A @ 230 VAC AC-input frequency 50/60 Hz (nominal) Branch circuit requirement Each chassis power supply should have its own dedicated, fused-branch circuit: For North America—15 A or 20 A For International—Circuits sized to local and national codes All Catalyst 6500 series AC-input power supplies require single-phase source AC. All AC power supply inputs are fully isolated. –Source AC can be out of phase between multiple power supplies in the same chassis, which means that PS1 can be operating from phase A and PS2 can be operating from phase B. –For high-line operation, the power supply operates with the hot conductor wired to a source AC phase and the neutral conductor wired either to ground or to another source AC phase as long as the net input voltage is in the range of 170 to 264 VAC. –Source AC can be out of phase between AC inputs on power supplies that are equipped with multiple AC inputs, which means that power cord 1 can be plugged into phase A and power cord 2 can be plugged into phase B.
A-12 Catalyst 6500 Series Switches Installation Guide OL-5781-08 Appendix A Power Supply Specifications 1000 W AC-Input Power Supply Ta b l e A - 8 list the power supply LEDs and their meanings. Power supply output capacity1000 W Power supply output 15 A @ +3.3 VDC 5A @ +5VDC 6A @ +12VDC 20.3A @ +42VDC Output holdup time 20 ms minimum kVA rating 11.25 kVA Heat dissipation 4213 BTU/hour (approx.) Weight 14.8 lb (6.7 kg) 1. The kVA rating listed for the power supply should be used as the sizing criteria for both UPS outputs as well as standard circuits and transformers to power a switch. Table A-7 1000 W Power Supply Specifications (continued) Specification Description Table A-8 1000 W Power Supply LEDs LED Meaning INPUT OK Green—Source AC voltage is OK. (Input voltage is 85 VAC or greater.) Off—Source AC voltage falls below 70 VAC, is not present, or the power supply is turned off. FAN OK Green—Power supply fan is operating properly. Off—Power supply fan failure is detected. OUTPUT FAIL Red—Problem with one or more of the DC-output voltages of the power supply is detected. Off—DC-output voltage with acceptable margins. NoteFor proper operation of the OUTPUT FAIL LED, systems with single power supplies must be configured with a minimum of one fan tray and one supervisor engine. Systems with dual power supplies must have a minimum configuration of one fan tray, one supervisor engine, and one additional module. Failure to meet these minimum configuration requirements can cause a false power supply output fail signal.
A-13 Catalyst 6500 Series Switches Installation Guide OL-5781-08 Appendix A Power Supply Specifications 1300 W AC-Input and DC-Input Power Supplies 1000 W Power Supply AC Power Cords Ta b l e A - 9 lists the specifications for the AC power cords that are available for the 1000 W AC-input power supply. The table includes references to power cord illustrations. NoteAll 1000 W power supply power cords are 8 feet 2 inches (2.5 meters) in length. NoteAll 1000 W power supply power cords have an IEC60320/C15 appliance plug at one end. 1300 W AC-Input and DC-Input Power Supplies The 1300 W AC-input power supply (WS-CAC-1300W) and 1300 W DC-input power supply (WS-CDC-1300W) are supported in the following Catalyst 6500 series switches: Catalyst 6506 Catalyst 6509 Catalyst 6509-NEB The 1300 W power supply (see Figure A-5 for the 1300 W AC-input power supply and Figure A-6 for the 1300 W DC-input power supply) shares the same form factor as the 1000 W, 2500 W, 3000 W, 4000 W, and 6000 W AC-input power supplies. Table A-9 1000 W AC-Input Power Supply Power Cords Locale Power Cord Part NumberAC Source Plug Type Cordset Rating Power Cord Reference Illustration Argentina CAB-7KACR= IRAM 2073 10 A, 250 VACFigure A-25 Australia, New Zealand CAB-7KACA= SAA AS 3112 15 A, 250 VAC Figure A-26 Continental Europe CAB-7KACE= CEE 7/7 16 A, 250 VACFigure A-27 Italy CAB-7KACI= CEI 23-16/7 10 A, 250 VACFigure A-28 Japan, North America CAB-7KAC-15= NEMA 5-15 15 A, 125 VACFigure A-29 United Kingdom CAB-7KACU= BS 1363 1 1. Plug contains a 13 A fuse. 10 A, 250 VACFigure A-30
A-14 Catalyst 6500 Series Switches Installation Guide OL-5781-08 Appendix A Power Supply Specifications 1300 W AC-Input and DC-Input Power Supplies Figure A-5 1300 W AC-input Power Supply Figure A-6 1300 W DC-Input Power Supply Power switchCable retention deviceAC power connectionINPU T O KFA N O KOUTPUT FAIL Captive installation screwStatus LEDs 16029I 0 Terminal block cover Captive installation screw o 16030 INPUT OKFA N OKOUTPUT FAIL
A-15 Catalyst 6500 Series Switches Installation Guide OL-5781-08 Appendix A Power Supply Specifications 1300 W AC-Input and DC-Input Power Supplies 1300 W Power Supply Specifications Ta b l e A - 1 1 lists the specifications for the 1300 W AC-input power supply. Table A-10 1300 W AC-Input Power Supply Specifications Specification Description AC-input type Autoranging input with power factor correction (PFC). NotePower factor correction is a standard feature on all Catalyst 6500 series AC-input power supplies. PFC reduces the reactive component in the source AC current allowing higher power factors (typically 99 percent or better) and lower harmonic current components. AC-input voltage Low-line (120 VAC nominal)—90 VAC (min) to 132 VAC (max) High-line (230 VAC nominal)—170 VAC (min) to 264 VAC (max) AC-input current 16 A @ 120 VAC 8 A @ 230 VAC AC-input frequency 50/60 Hz (nominal) (±3 Hz for full range) Branch circuit requirement Each chassis power supply should have its own dedicated, fused-branch circuit: For North America—15 A or 20 A For International—Circuits sized to local and national codes All Catalyst 6500 series AC-input power supplies require single-phase source AC. All AC power supply inputs are fully isolated. –Source AC can be out of phase between multiple power supplies in the same chassis, which means that PS1 can be operating from phase A and PS2 can be operating from phase B. –For high-line operation, the power supply operates with the hot conductor wired to a source AC phase and the neutral conductor wired either to ground or to another source AC phase as long as the net input voltage is in the range of 170 to 264 VAC. –Source AC can be out of phase between AC inputs on power supplies that are equipped with multiple AC inputs, which means that power cord 1 can be plugged into phase A and power cord 2 can be plugged into phase B. Power supply output capacity 1300 W maximum (AC-input) 1360 W maximum (DC-input) Power supply output 15 A @ +3.3 VDC 5A @ +5VDC 6A @ +12VDC 27.46 A @ +42 VDC Output holdup time 20 ms minimum
A-16 Catalyst 6500 Series Switches Installation Guide OL-5781-08 Appendix A Power Supply Specifications 1300 W AC-Input and DC-Input Power Supplies Ta b l e A - 1 1 lists the specifications for the 1300 W DC-input power supply. Ta b l e A - 1 2 lists the 1300 W power supply LEDS and their meanings. kVA rating 11.625 kVA Heat dissipation 5478 BTU/hour (approx.) Weight 18.4 lb (8.3 kg) 1. The kVA rating listed for the power supply should be used as the sizing criteria for both UPS outputs as well as standard circuits and transformers to power a switch. Table A-10 1300 W AC-Input Power Supply Specifications (continued) Specification Description Table A-11 1300 W DC-Input Power Supply Specifications Specification Description DC-input voltage –48 VDC to –60 VDC continuous DC-input current 39 A @ –48 VDC 31 A @ –60 VDC Power supply output capacity1360 W maximum (DC-input) Power supply output 15 A @ +3.3 VDC 5A @ +5VDC 6A @ +12VDC 28.9A @ +42VDC DC input terminal block Accepts 3 AWG to 10 AWG copper conductors. Actual size of the wire needed is determined by the installer or local electrician. Terminal block material is rated at 120°C. Output holdup time 8 ms Heat dissipation 6447 BTU/hour (approx.) Weight 21.0 lb (9.5 kg)
A-17 Catalyst 6500 Series Switches Installation Guide OL-5781-08 Appendix A Power Supply Specifications 1300 W AC-Input and DC-Input Power Supplies 1300 W Power Supply AC Power Cords Ta b l e A - 1 3 lists the specifications for the AC power cords that are available for the 1300 W AC-input power supply. The table includes references to power cord illustrations. NoteAll 1300 W power supply power cords are 14 feet (4.3 meters) in length. NoteAll 1300 W power supply power cords have an IEC60320/C19 appliance connector at one end. Table A-12 1300 W AC-Input and DC-Input Power Supply LEDs LED Meaning INPUT OK AC-input power supplies: Green—Source AC voltage is OK. (Input voltage is 85 VAC or greater.) Off—Source AC voltage falls below 70 VAC, is not present, or the power supply turned off. DC-input power supplies: Green—Source DC voltage is OK. (Input voltage is –40.5 VDC or greater.) Off—Source DC voltage falls below –33 VDC, is not present, or the power supply is turned off. FAN OK Green—Power supply fan is operating properly. Off—Power supply fan failure is detected. OUTPUT FAIL Red—Problem with one or more of the DC-output voltages of the power supply is detected. Off—DC-output voltages within acceptable margins. NoteFor proper operation of the OUTPUT FAIL LED, systems with single power supplies must be configured with a minimum of one fan tray and one supervisor engine. Systems with dual power supplies must have a minimum configuration of one fan tray, one supervisor engine, and one additional module. Failure to meet these minimum configuration requirements can cause a false power supply output fail signal.
A-18 Catalyst 6500 Series Switches Installation Guide OL-5781-08 Appendix A Power Supply Specifications 1400 W AC-Input Power Supply 1400 W AC-Input Power Supply The 1400 W AC-input power supply (PWR-1400-AC) can be installed in the Catalyst 6503 switch and Catalyst 6503-E switch chassis only. Due to form factor differences, the 1400 W AC-input power supply cannot be installed in any other Catalyst 6500 series switch chassis. The 1400 W power supplies (see Figure A-7) do not connect directly to source AC but use power entry modules (PEMs), located on the front of the Catalyst 6503 and Catalyst 6503-E switch chassis, to connect the site power source to the power supply located in the back of the chassis. The AC-input PEM (PEM-20A-AC+) (shown in Figure A-8) provides an input power connection on the front of the router chassis to connect the site power source to the power supply. The PEMs have an illuminated power switch, current protection, surge and EMI suppression, and filtering functions. TableA-13 1300W Power Supply AC Power Cords Locale Power Cord Part NumberAC Source Plug Type Cordset Rating Power Cord Reference Illustration Argentina CAB-7513ACR= IRAM 2073 10 A, 250 VACFigure A-31 Australia, New Zealand CAB-7513ACA= SAA AS 3112 15 A, 250 VACFigure A-32 Continental Europe CAB-7513ACE= CEE 7/7 16 A, 250 VACFigure A-33 Israel CAB-AC-2500W-ISRL= SI16S3 16 A, 250 VACFigure A-34 Italy CAB-7513ACI= CEI 23-16/7 16 A, 250 VACFigure A-35 Japan, North America CAB-7513AC= NEMA 5-20 1 1. For Japan, ask your local electrical contractor to prepare the NEMA 5-20 power plug. 20 A, 125 VACFigure A-36 People’s Republic of ChinaCAB-AC16A-CH= GB16C 16 A, 250 VACFigure A-37 South Africa CAB-7513ACSA= IEC 884-1 16 A, 250 VACFigure A-38 Switzerland CAB-ACS-10= SEV 1011 10 A, 250 VACFigure A-39 United Kingdom CAB-7513ACU= BS 1363 2 2. Plug contains a 13 A fuse. 13 A, 250 VACFigure A-40 Power Distribution Unit (PDU) 3 3. The PDU power cable is designed for users who power their switch from a PDU. The end of the cable that plugs into the chassis power supply has a C19 connector; the other end of the cable that connects to the PDU has a C20 connector. CAB-C19-CBN= IEC 60320 C19 IEC 60320 C2016 A, 250 VACFigure A-47
A-19 Catalyst 6500 Series Switches Installation Guide OL-5781-08 Appendix A Power Supply Specifications 1400 W AC-Input Power Supply Figure A-7 1400 W AC-Input Power Supply (PWR-1400-AC) Figure A-8 1400 W AC-Input PEM (PEM-20A-AC+) 1400 W Power Supply Specifications Ta b l e A - 1 4 lists the specifications for the 1400 W AC-input power supply. 63183 INPUT OKF AN OKOUTPUT FAIL Captive installation screws Status LEDs Captive installation screwsIEC 60320 C19 connector AC power switch130057 PEM-20A-AC+50-60 Hz 120-240V 15A Table A-14 1400 W AC-Input Power Supply Specifications Specification Description AC-input type Autoranging input with power factor correction (PFC). NotePower factor correction is a standard feature on all Catalyst 6500 series AC-input power supplies. PFC reduces the reactive component in the source AC current allowing higher power factors (typically 99 percent or better) and lower harmonic current components. AC-input voltage Low-line (120 VAC nominal)—90 VAC (min) to 132 VAC (max) High-line (230 VAC nominal)—170 VAC (min) to 264 VAC (max) AC-input current 16 A @ 120 VAC 8 A @ 230 VAC AC-input frequency 50/60 Hz (nominal) (±3 Hz for full range)
A-20 Catalyst 6500 Series Switches Installation Guide OL-5781-08 Appendix A Power Supply Specifications 1400 W AC-Input Power Supply Ta b l e A - 1 5 lists the 1400 W AC-input power supply LEDs and their meanings. Branch circuit requirement Each chassis power supply should have its own dedicated, fused-branch circuit: For North America—20 A For International—Circuits sized to local and national codes All AC power supply inputs are fully isolated. –Source AC can be out of phase between multiple power supplies in the same chassis, which means that PS1 can be operating from phase A and PS2 can be operating from phase B. –For high-line operation, the power supply operates with the hot conductor wired to a source AC phase and the neutral conductor wired either to ground or to another source AC phase as long as the net input voltage is in the range of 170 to 264 VAC. –Source AC can be out of phase between AC inputs on power supplies that are equipped with multiple AC inputs, which means that power cord 1 can be plugged into phase A and power cord 2 can be plugged into phase B. Power supply output capacity1400 W Power supply output 15 A @ +1.5 V 2.5 A @ +3.3 V 27.4A @ +50V Output holdup time 20 ms minimum kVA rating 11.75 kVA Heat dissipation 5976 BTU/hour (approx.) Weight 7.8 lb (3.5 kg) 1. The kVA rating listed for the power supply should be used as the sizing criteria for both UPS outputs as well as standard circuits and transformers to power a switch. Table A-14 1400 W AC-Input Power Supply Specifications (continued) Specification Description