19 Catalyst 6500 Series Switches Installation Guide OL-5781-08 Preface Related Documentation Related Documentation For additional Catalyst 6500 series switch information, refer to these publications: Regulatory Compliance and Safety Information for the Catalyst 6500 Series Switches Catalyst 6500 Series Switch Quick Software Configuration Guide Catalyst 6500 Series Switch Module Installation Guide Catalyst 6500 Series Switch Software Configuration Guide Catalyst 6500 Series Switch Command Reference Catalyst 6500 Series Switch Cisco IOS Software Configuration Guide Catalyst 6500 Series Switch Cisco IOS Command Reference ATM Software Configuration and Command Reference—Catalyst 5000 Family and Catalyst 6000 Family Switches Catalyst 6500 Series Switch System Message Guide For information about MIBs, refer to this URL: http://www.cisco.com/public/sw-center/netmgmt/cmtk/mibs.shtml
20 Catalyst 6500 Series Switches Installation Guide OL-5781-08 Preface Related Documentation Obtaining Documentation and Submitting a Service Request For information on obtaining documentation, submitting a service request, and gathering additional information, see the monthly What’s New in Cisco Product Documentation, which also lists all new and revised Cisco technical documentation, at: http://www.cisco.com/en/US/docs/general/whatsnew/whatsnew.html Subscribe to the What’s New in Cisco Product Documentation as a Really Simple Syndication (RSS) feed and set content to be delivered directly to your desktop using a reader application. The RSS feeds are a free service and Cisco currently supports RSS Version 2.0.
CH A P T E R 1-1 Catalyst 6500 Series Switches Installation Guide OL-5781-08 1 Product Overview Revised: February 3, 2012 This chapter describes the Catalyst 6500 series switches and contains these sections: Catalyst 6503 Switch, page 1-2 Catalyst 6503-E Switch, page 1-8 Catalyst 6504-E Switch, page 1-13 Catalyst 6506 Switch, page 1-18 Catalyst 6506-E Switch, page 1-24 Catalyst 6509 Switch, page 1-30 Catalyst 6509-E Switch, page 1-36 Catalyst 6509-NEB Switch, page 1-42 Catalyst 6509-NEB-A Switch, page 1-49 Catalyst 6509-V-E Switch, page 1-55 Catalyst 6513 Switch, page 1-61 Catalyst 6513-E Switch, page 1-67 NoteThe Catalyst 6000 series switches (Catalyst 6006 switch and Catalyst 6009 switch) are described in a separate publication, the Catalyst 6000 Series Switches Installation Guide. NoteThroughout this publication, except where noted, the term supervisor engine is used to refer to Supervisor Engine 2, Supervisor Engine 32, Supervisor Engine 32 PISA, Supervisor Engine 720, and Supervisor Engine 720-10GE.
1-2 Catalyst 6500 Series Switches Installation Guide OL-5781-08 Chapter 1 Product Overview Catalyst 6503 Switch Catalyst 6503 Switch The Catalyst 6503 switch is a 3-slot horizontal chassis supporting redundant power supplies, redundant supervisor engines, and slots for up to two modules. The chassis is NEBS L3 compliant. Figure 1-1 shows the front view of the chassis and Figure 1-2 shows the rear view of the chassis. Figure 1-1 Catalyst 6503 Switch—Front View Figure 1-2 Catalyst 6503 Switch—Rear View 91239 Slots 1-3 (top to bottom) Fan assemblyPEM 1 PEM 2 ESD ground strap connection Supervisor Engine Modules W S-X6516-G E-T X 16 POR T 1000 BA SE-T G E1234567 8910 111213 141516 LINK LINK LINK LINK LINK LINK LINK LINK LINK LINK LINK LINK LINK LINK LINK LINK W S-X6516-G E -T X 16 PO RT 1000 BA SE-T G E12345 67 8910 111213 141516 LINK LINK LINK LINK LINK LINK LINK LINK LINK LINK LINK LINK LINK LINK LINK LINK W S-S UP 32-G E-3B ST A T US SYST EM ACT IVE PWR MGMT RESETCAT ALYST 6500 SUPER VIS OR ENGI NE 32CO NSO LE EJECTDIS K 0PORT 1 PO RT 2 PO RT 3 PO RT 4PO RT 5 PORT 6 PO RT 7P O R T 8P O RT 9 USB 2. 0 LI NK LINK LI NK LI NK LI NK LINK LI NK LIN K LINK 63031 INPUT OKFA N OKOUTPUT FA I L INPUT OKFA N OKOUTPUT FAIL Power supply 2 (redundant) Power supply 1
1-3 Catalyst 6500 Series Switches Installation Guide OL-5781-08 Chapter 1 Product Overview Catalyst 6503 Switch Ta b l e 1 - 1 lists the features of the Catalyst 6503 switch chassis. Table 1-1 Catalyst 6503 Switch Features Feature Description Chassis Three horizontal slots. Slots are numbered from 1 (top) to 3 (bottom). Supervisor engine Supports Supervisor Engine 2, Supervisor Engine 32, Supervisor Engine 32 PISA, and Supervisor Engine 720. NoteRefer to your software release notes for the minimum software release versions required to support the supervisor engines. Supervisor engines can be installed in either slot 1 or slot 2. NoteSlots not occupied by supervisor engines can be used for modules. Check your software release notes for any restrictions on the type of module that can be installed. Supervisor Engine 720 with 10-GB uplink ports (VS-S720-10G-3C and VS-S720-10G-3CXL) is not supported on the Catalyst 6503 switch chassis. Supervisor Engine 32, Supervisor Engine 32 PISA, or a Supervisor Engine 720 requires that the optional high-speed fan tray (FAN-MOD-3HS) be installed in the chassis. Supervisor Engine 720 has built-in switching fabric. The uplink ports are fully functional on the redundant supervisor engine in standby mode. NoteIn systems with redundant supervisor engines, both supervisor engines must be the same model and have the same daughter card configurations. Each supervisor engine must have the resources to run the switch on its own, which means that all supervisor engine resources are duplicated. Identical supervisor engine memory configurations are recommended, but are not required as long as the supervisor engine with the smaller memory configuration is sufficient to run the configured features of the switch. Additionally, each supervisor engine must have its own flash device and console port connections. Modules Supports up to two Catalyst 6500 series modules. Does not support the WS-C6500-SFM and WS-X6500-SFM2 Switch Fabric Modules. Does not support the WS-X67xx modules. Some Catalyst 6500 series modules may: –Not be supported –Require that you install a Supervisor Engine 720 –Have chassis slot restrictions –Require a specific software release level to operate NoteCheck your software release notes for specific information.
1-4 Catalyst 6500 Series Switches Installation Guide OL-5781-08 Chapter 1 Product Overview Catalyst 6503 Switch Backplane bandwidth32 GBps shared bus. 720 GBps switch fabric. Clock and VTT modules One replaceable clock module (CLK-7600=) provides clocking signals to the EOBC channel and the switching bus. Nonreplaceable voltage termination (VTT) module provides reference voltage for bus signals. Fan tray The chassis supports one hot-swappable fan tray. Two fan tray models are available: –FAN-MOD-3 (Standard fan tray—170 CFM). Supports Supervisor Engine 1 and Supervisor Engine 2 only; does not support Supervisor Engine 32 or Supervisor Engine 720. –FAN-MOD-3HS (Optional high-speed fan tray—270 CFM). Required for Supervisor Engine 32 and Supervisor Engine 720. Supports Supervisor Engine 2. NoteBoth fan tray models contain four individual fans. The individual fans are not field replaceable; you must replace the fan tray in the event of a fan failure. NoteThe WS-C6503-E-FAN tray is not supported in the Catalyst 6503 chassis. Fan tray STATUS LED –Red—One or more individual fans have failed. –Green—Fan tray is operating normally. Table 1-1 Catalyst 6503 Switch Features (continued) Feature Description
1-5 Catalyst 6500 Series Switches Installation Guide OL-5781-08 Chapter 1 Product Overview Catalyst 6503 Switch Power Entry Module (PEM)1A PEM is required for each installed power supply. –PEM-15A-AC (PEM for 950 W AC-input power supplies). –PEM-DC/3 (PEM for 950 W DC-input power supplies). –PEM-20A-AC+ (PEM for 1400 W AC-input power supplies). Power supplies Supports one or two power supplies. The following power supplies are supported: –PWR-950-AC (950 W AC-input power supply). –PWR-950-DC (950 W DC-input power supply). –PWR-1400-AC (1400 W AC-input power supply). Installed power supplies can be of different wattage ratings. Installed power supplies can be both AC-input, both DC-input, or one AC-input and one DC-input. Power supplies can be configured in either redundant or combined mode. NoteFor Catalyst 6503 and Catalyst 6503-E chassis that are equipped with DC-input power supplies, the system (NEBS) ground serves as the primary safety ground and must be installed. The DC-input power supplies for these chassis do not have a separate ground. All Catalyst 6500 series AC-input power supplies require single-phase source AC. Source AC can be out of phase between multiple power supplies or multiple AC-power plugs on the same power supply because all AC power supply inputs are isolated. Single power supplies are installed in the lower power supply bay. The second power supply is installed in the upper power supply bay. NoteFor proper operation of the power supply OUTPUT FAIL LED, systems with single power supplies must be configured with a minimum of one fan tray and one supervisor engine. Systems with dual power supplies must have a minimum configuration of one fan tray, one supervisor engine, and one additional module. Failure to meet these minimum configuration requirements can cause a false power supply output fail signal. 1. PEMs are required for Catalyst 6503 and Catalyst 6503-E switches only. Table 1-1 Catalyst 6503 Switch Features (continued) Feature Description
1-6 Catalyst 6500 Series Switches Installation Guide OL-5781-08 Chapter 1 Product Overview Catalyst 6503 Switch Ta b l e 1 - 2 lists the environmental and physical specifications of the Catalyst 6503 switch chassis. Table 1-2 Catalyst 6503 Switch Specifications Item Specification Environmental Temperature, operating Certified for operation: 32° to 104°F (0° to 40°C) Designed and tested for operation: 32° to 131°F (0° to 55°C) NoteThe Catalyst 6500 series switches are equipped with internal air temperature sensors that are triggered at 40°C (104°F) generating a minor alarm and at 55°C (131°F) generating a major alarm. Temperature, nonoperating and storageChassis unpackaged: –4° to 149°F (–20° to 65°C) Chassis in protective shipping package: –40° to 158°F (–40° to 70°C) Thermal transition 0.5°C per minute (hot to cold) 0.33°C per minute (cold to hot) Humidity (RH), ambient (noncondensing) operating Operating: 5% to 90% Nonoperating and storage: 5% to 95% Altitude, operating Certified for operation: 0 to 6500 ft (0 to 2000 m) Designed and tested for operation: –200 to 10,000 ft (–60 to 3000 m) Shock and vibration This switch was complies with Network Equipment Building Systems (NEBS) (Zone 4 per GR-63-Core) in the following areas: Earthquake environment and criteria Office vibration and criteria Transportation vibration and criteria Shock Operational—5 G 30 ms, half-sine (IEC 68-2-27) Nonoperational—20 G, 7.5 ms, trapezoidal Vibration Operational—3 Hz to 500 Hz, Power Spectral Density (PSD)—0.0005 G2/Hz at 10 Hz and 200 Hz. 5 dB/octave roll off at each end. 0.5 hours per axis (1.12 Grms). Acoustic noise 64 to 76 dB. International Organization for Standardization (ISO) 7779: Bystander position operating to an ambient temperature of 86°F (30°C).
1-7 Catalyst 6500 Series Switches Installation Guide OL-5781-08 Chapter 1 Product Overview Catalyst 6503 Switch Physical Characteristics Dimensions (H x W x D) 7 x 17.37 x 21.75 in. (17.8 x 44.1 x 55.2 cm). Chassis requires 4 RU1. The Catalyst 6503 switch chassis is designed to install in standard 19-inch equipment racks that meet ANSI/EIA 310-D, IEC 60297, and ETS 300-119 standards. Weight Chassis only: 27 lb (12.25 kg). Chassis fully configured with 1 supervisor engine, 2 modules, 2 AC-input PEMs, and 2 AC-input power supplies: 85.4 lb (38.7 kg). Airflow FAN-MOD-3 (Standard fan tray)—170 CFM FAN-MOD-3HS (Optional high-speed fan tray)—270 CFM NoteTo maintain proper air circulation through the Catalyst switch chassis, we recommend that you maintain a minimum 6-inch (15 cm) separation between a wall and the chassis air intake or a wall and the chassis air exhaust. You should also allow a minimum separation of 12 inches (30.5 cm) between the hot air exhaust on one chassis and the air intake on another chassis. Failure to maintain adequate air space can cause the chassis to overheat and the system to fail. On Catalyst chassis in which the airflow is from front to back, the chassis may be placed side-by-side. 1. RU = rack units Table 1-2 Catalyst 6503 Switch Specifications (continued) Item Specification
1-8 Catalyst 6500 Series Switches Installation Guide OL-5781-08 Chapter 1 Product Overview Catalyst 6503-E Switch Catalyst 6503-E Switch The Catalyst 6503-E switch is an enhanced version of the Catalyst 6503 switch. The 3-slot horizontal chassis supports redundant power supplies, redundant supervisor engines, and slots for up to two modules. It also supports a greater power capacity per slot than the Catalyst6503 switch chassis. The Catalyst 6503-E switch chassis is NEBS L3 compliant. Figure 1-3 shows the front view of the chassis and Figure 1-4 shows the rear view of the chassis. Figure 1-3 Catalyst 6503-E Switch—Front View Figure 1-4 Catalyst 6503-E Switch—Rear View 91239 Slots 1-3 (top to bottom) Fan assemblyPEM 1 PEM 2 ESD ground strap connection Supervisor Engine Modules W S-X6516-G E -T X 16 PO R T 1000 B ASE -T GE1234567 8910 111213 141516 LINK LINK LINK LINK LINK LINK LINK LINK LINK LINK LINK LINK LINK LINK LINK LINK W S-X6516-GE -T X 16 PO RT 1000 BA SE-T G E12345 67 8910 111213 141516 LINK LINK LINK LINK LINK LINK LINK LINK LINK LINK LINK LINK LINK LINK LINK LINK W S-S UP 32-G E-3B ST A T US SYST EM ACTIVE PWR MGMT RESETCAT ALYST 6500 SUPER VIS OR ENGI NE 32CO NSO LE EJECTDISK 0PORT 1 PO RT 2 PO RT 3 P O RT 4PO RT 5 PO RT 6 PO RT 7PO R T 8P ORT 9 USB 2. 0 LI NK LINK LI NK LI NK LI NK LINK LI NK LIN K LINK 63031 INPUT OKFA N OKOUTPUT FA I L INPUT OKFA N OKOUTPUT FA I L Power supply 2 (redundant) Power supply 1