Home > Cisco > Ethernet Switch > Cisco 6500e Manual

Cisco 6500e Manual

    Download as PDF Print this page Share this page

    Have a look at the manual Cisco 6500e Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 53 Cisco manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.

    Page
    of 454
    							19
    Catalyst 6500 Series Switches Installation Guide
    OL-5781-08
    Preface
    Related Documentation
    Related Documentation
    For additional Catalyst 6500 series switch information, refer to these publications:
    Regulatory Compliance and Safety Information for the Catalyst 6500 Series Switches
    Catalyst 6500 Series Switch Quick Software Configuration Guide
    Catalyst 6500 Series Switch Module Installation Guide
    Catalyst 6500 Series Switch Software Configuration Guide
    Catalyst 6500 Series Switch Command Reference
    Catalyst 6500 Series Switch Cisco IOS Software Configuration Guide
    Catalyst 6500 Series Switch Cisco IOS Command Reference
    ATM Software Configuration and Command Reference—Catalyst 5000 Family and Catalyst 6000 
    Family Switches
    Catalyst 6500 Series Switch System Message Guide
    For information about MIBs, refer to this URL: 
    http://www.cisco.com/public/sw-center/netmgmt/cmtk/mibs.shtml 
    						
    							20
    Catalyst 6500 Series Switches Installation Guide
    OL-5781-08
    Preface
    Related Documentation
    Obtaining Documentation and Submitting a Service Request
    For information on obtaining documentation, submitting a service request, and gathering additional 
    information, see the monthly What’s New in Cisco Product Documentation, which also lists all new and 
    revised Cisco technical documentation, at:
    http://www.cisco.com/en/US/docs/general/whatsnew/whatsnew.html
    Subscribe to the What’s New in Cisco Product Documentation as a Really Simple Syndication (RSS) feed 
    and set content to be delivered directly to your desktop using a reader application. The RSS feeds are a free 
    service and Cisco currently supports RSS Version 2.0. 
    						
    							CH A P T E R
    1-1
    Catalyst 6500 Series Switches Installation Guide
    OL-5781-08
    1
    Product Overview
    Revised: February 3, 2012
    This chapter describes the Catalyst 6500 series switches and contains these sections:
    Catalyst 6503 Switch, page 1-2
    Catalyst 6503-E Switch, page 1-8
    Catalyst 6504-E Switch, page 1-13
    Catalyst 6506 Switch, page 1-18
    Catalyst 6506-E Switch, page 1-24
    Catalyst 6509 Switch, page 1-30
    Catalyst 6509-E Switch, page 1-36
    Catalyst 6509-NEB Switch, page 1-42
    Catalyst 6509-NEB-A Switch, page 1-49
    Catalyst 6509-V-E Switch, page 1-55
    Catalyst 6513 Switch, page 1-61
    Catalyst 6513-E Switch, page 1-67
    NoteThe Catalyst 6000 series switches (Catalyst 6006 switch and Catalyst 6009 switch) are described in a 
    separate publication, the Catalyst 6000 Series Switches Installation Guide.
    NoteThroughout this publication, except where noted, the term supervisor engine is used to refer to 
    Supervisor Engine 2, Supervisor Engine 32, Supervisor Engine 32 PISA, Supervisor Engine 720, and 
    Supervisor Engine 720-10GE.  
    						
    							1-2
    Catalyst 6500 Series Switches Installation Guide
    OL-5781-08
    Chapter 1      Product Overview
      Catalyst 6503 Switch
    Catalyst 6503 Switch 
    The Catalyst 6503 switch is a 3-slot horizontal chassis supporting redundant power supplies, redundant 
    supervisor engines, and slots for up to two modules. The chassis is NEBS L3 compliant. Figure 1-1 
    shows the front view of the chassis and Figure 1-2 shows the rear view of the chassis. 
    Figure 1-1 Catalyst 6503 Switch—Front View
    Figure 1-2 Catalyst 6503 Switch—Rear View
    91239
    Slots 1-3
    (top to bottom) Fan assemblyPEM 1 PEM 2
    ESD ground
    strap connection
    Supervisor
    Engine
    Modules
    W
    S-X6516-G
    E-T X
     
    16 POR
    T
     1000 BA
    SE-T G
    E1234567
    8910
    111213 141516
    LINK
    LINK
    LINK
    LINK
    LINK
    LINK
    LINK
    LINK
    LINK
    LINK
    LINK
    LINK
    LINK LINK
    LINK
    LINK
    W
    S-X6516-G
    E
    -T X
     
    16 PO
    RT 1000 BA
    SE-T G
    E12345
    67
    8910
    111213 141516
    LINK
    LINK
    LINK
    LINK
    LINK
    LINK
    LINK
    LINK
    LINK
    LINK
    LINK
    LINK
    LINK LINK
    LINK
    LINK
    W
    S-S
    UP
    32-G
    E-3B
    ST
    A
    T
    US
    SYST
    EM
    ACT
    IVE
    PWR MGMT
    RESETCAT
    ALYST  
     6500
     SUPER
    VIS
    OR  
    ENGI
    NE
      
    32CO
    NSO
    LE
    EJECTDIS
    K 0PORT 
    1
    PO
    RT 2
    PO
    RT 
    3
    PO
    RT 4PO
    RT 5
    PORT 
    6
    PO
    RT 
    7P
    O
    R
    T 8P
    O
    RT 9
    USB 
    2.
    0
    LI
    NK
    LINK
    LI
    NK
    LI
    NK
    LI
    NK
    LINK
    LI
    NK
    LIN
    K
    LINK
    63031 
    INPUT
    OKFA N
    OKOUTPUT
    FA I L
    INPUT
    OKFA N
    OKOUTPUT
    FAIL
    Power supply 2
    (redundant)
    Power supply 1 
    						
    							1-3
    Catalyst 6500 Series Switches Installation Guide
    OL-5781-08
    Chapter 1      Product Overview
      Catalyst 6503 Switch
    Ta b l e 1 - 1 lists the features of the Catalyst 6503 switch chassis. 
    Table 1-1 Catalyst 6503 Switch Features
    Feature Description
    Chassis
    Three horizontal slots. Slots are numbered from 1 (top) to 3 (bottom).
    Supervisor engine
    Supports Supervisor Engine 2, Supervisor Engine 32, Supervisor 
    Engine 32 PISA, and Supervisor Engine 720.
    NoteRefer to your software release notes for the minimum software 
    release versions required to support the supervisor engines.
    Supervisor engines can be installed in either slot 1 or slot 2. 
    NoteSlots not occupied by supervisor engines can be used for modules. 
    Check your software release notes for any restrictions on the type of 
    module that can be installed.
    Supervisor Engine 720 with 10-GB uplink ports (VS-S720-10G-3C and 
    VS-S720-10G-3CXL) is not supported on the Catalyst 6503 switch 
    chassis.
    Supervisor Engine 32, Supervisor Engine 32 PISA, or a Supervisor 
    Engine 720 requires that the optional high-speed fan tray 
    (FAN-MOD-3HS) be installed in the chassis.
    Supervisor Engine 720 has built-in switching fabric. 
    The uplink ports are fully functional on the redundant supervisor engine 
    in standby mode. 
    NoteIn systems with redundant supervisor engines, both supervisor 
    engines must be the same model and have the same daughter card 
    configurations. Each supervisor engine must have the resources to 
    run the switch on its own, which means that all supervisor engine 
    resources are duplicated. Identical supervisor engine memory 
    configurations are recommended, but are not required as long as the 
    supervisor engine with the smaller memory configuration is 
    sufficient to run the configured features of the switch. Additionally, 
    each supervisor engine must have its own flash device and console 
    port connections.
    Modules 
    Supports up to two Catalyst 6500 series modules. 
    Does not support the WS-C6500-SFM and WS-X6500-SFM2 Switch 
    Fabric Modules.
    Does not support the WS-X67xx modules.
    Some Catalyst 6500 series modules may:
    –Not be supported
    –Require that you install a Supervisor Engine 720
    –Have chassis slot restrictions
    –Require a specific software release level to operate
    NoteCheck your software release notes for specific information. 
    						
    							1-4
    Catalyst 6500 Series Switches Installation Guide
    OL-5781-08
    Chapter 1      Product Overview
      Catalyst 6503 Switch
    Backplane bandwidth32 GBps shared bus.
    720 GBps switch fabric.
    Clock and VTT modules
    One replaceable clock module (CLK-7600=) provides clocking signals 
    to the EOBC channel and the switching bus.
    Nonreplaceable voltage termination (VTT) module provides reference 
    voltage for bus signals.
    Fan tray
    The chassis supports one hot-swappable fan tray. Two fan tray models 
    are available:
    –FAN-MOD-3 (Standard fan tray—170 CFM). Supports Supervisor 
    Engine 1 and Supervisor Engine 2 only; does not support 
    Supervisor Engine 32 or Supervisor Engine 720.
    –FAN-MOD-3HS (Optional high-speed fan tray—270 CFM). 
    Required for Supervisor Engine 32 and Supervisor Engine 720. 
    Supports Supervisor Engine 2.
    NoteBoth fan tray models contain four individual fans. The individual 
    fans are not field replaceable; you must replace the fan tray in the 
    event of a fan failure.
    NoteThe WS-C6503-E-FAN tray is not supported in the Catalyst 6503 
    chassis.
    Fan tray STATUS LED
    –Red—One or more individual fans have failed.
    –Green—Fan tray is operating normally.
    Table 1-1 Catalyst 6503 Switch Features (continued)
    Feature Description 
    						
    							1-5
    Catalyst 6500 Series Switches Installation Guide
    OL-5781-08
    Chapter 1      Product Overview
      Catalyst 6503 Switch
    Power Entry Module (PEM)1A PEM is required for each installed power supply. 
    –PEM-15A-AC (PEM for 950 W AC-input power supplies).
    –PEM-DC/3 (PEM for 950 W DC-input power supplies).
    –PEM-20A-AC+ (PEM for 1400 W AC-input power supplies).
    Power supplies
    Supports one or two power supplies. The following power supplies are 
    supported:
    –PWR-950-AC (950 W AC-input power supply).
    –PWR-950-DC (950 W DC-input power supply).
    –PWR-1400-AC (1400 W AC-input power supply).
    Installed power supplies can be of different wattage ratings. Installed 
    power supplies can be both AC-input, both DC-input, or one AC-input 
    and one DC-input. Power supplies can be configured in either redundant 
    or combined mode.
    NoteFor Catalyst 6503 and Catalyst 6503-E chassis that are equipped 
    with DC-input power supplies, the system (NEBS) ground serves as 
    the primary safety ground and must be installed. The DC-input 
    power supplies for these chassis do not have a separate ground.
    All Catalyst 6500 series AC-input power supplies require single-phase 
    source AC. Source AC can be out of phase between multiple power 
    supplies or multiple AC-power plugs on the same power supply because 
    all AC power supply inputs are isolated.
    Single power supplies are installed in the lower power supply bay. The 
    second power supply is installed in the upper power supply bay.
    NoteFor proper operation of the power supply OUTPUT FAIL LED, 
    systems with single power supplies must be configured with a 
    minimum of one fan tray and one supervisor engine. Systems with 
    dual power supplies must have a minimum configuration of one fan 
    tray, one supervisor engine, and one additional module. Failure to 
    meet these minimum configuration requirements can cause a false 
    power supply output fail signal.
    1. PEMs are required for Catalyst 6503 and Catalyst 6503-E switches only.
    Table 1-1 Catalyst 6503 Switch Features (continued)
    Feature Description 
    						
    							1-6
    Catalyst 6500 Series Switches Installation Guide
    OL-5781-08
    Chapter 1      Product Overview
      Catalyst 6503 Switch
    Ta b l e 1 - 2 lists the environmental and physical specifications of the Catalyst 6503 switch chassis. 
    Table 1-2 Catalyst 6503 Switch Specifications
    Item Specification
    Environmental
    Temperature, operating Certified for operation: 32° to 104°F (0° to 40°C)
    Designed and tested for operation: 32° to 131°F (0° to 55°C)
    NoteThe Catalyst 6500 series switches are equipped with internal air 
    temperature sensors that are triggered at 40°C (104°F) generating a 
    minor alarm and at 55°C (131°F) generating a major alarm.
    Temperature, nonoperating 
    and storageChassis unpackaged: –4° to 149°F (–20° to 65°C)
    Chassis in protective shipping package: –40° to 158°F (–40° to 70°C)
    Thermal transition 0.5°C per minute (hot to cold)
    0.33°C per minute (cold to hot)
    Humidity (RH), ambient 
    (noncondensing) operating Operating: 5% to 90%
    Nonoperating and storage: 5% to 95%
    Altitude, operating Certified for operation: 0 to 6500 ft (0 to 2000 m)
    Designed and tested for operation: –200 to 10,000 ft (–60 to 3000 m)
    Shock and vibration This switch was complies with Network Equipment Building Systems 
    (NEBS) (Zone 4 per GR-63-Core) in the following areas:
    Earthquake environment and criteria
    Office vibration and criteria
    Transportation vibration and criteria
    Shock
    
    Operational—5 G 30 ms, half-sine (IEC 68-2-27)
    Nonoperational—20 G, 7.5 ms, trapezoidal
    Vibration 
    Operational—3 Hz to 500 Hz, 
    Power Spectral Density (PSD)—0.0005 G2/Hz at 10 Hz and 200 Hz. 
    5 dB/octave roll off at each end. 0.5 hours per axis (1.12 Grms).
    Acoustic noise 64 to 76 dB. International Organization for Standardization (ISO) 7779: 
    Bystander position operating to an ambient temperature of 86°F (30°C). 
    						
    							1-7
    Catalyst 6500 Series Switches Installation Guide
    OL-5781-08
    Chapter 1      Product Overview
      Catalyst 6503 Switch
    Physical Characteristics
    Dimensions (H x W x D)
    7 x 17.37 x 21.75 in. (17.8 x 44.1 x 55.2 cm). 
    Chassis requires 4 RU1.
    The Catalyst 6503 switch chassis is designed to install in standard 
    19-inch equipment racks that meet ANSI/EIA 310-D, IEC 60297, and 
    ETS 300-119 standards.
    Weight
    Chassis only: 27 lb (12.25 kg).
    Chassis fully configured with 1 supervisor engine, 2 modules, 
    2 AC-input PEMs, and 2 AC-input power supplies: 85.4 lb (38.7 kg).
    Airflow
    FAN-MOD-3 (Standard fan tray)—170 CFM
    FAN-MOD-3HS (Optional high-speed fan tray)—270 CFM
    NoteTo maintain proper air circulation through the Catalyst switch 
    chassis, we recommend that you maintain a minimum 6-inch (15 cm) 
    separation between a wall and the chassis air intake or a wall and the 
    chassis air exhaust. You should also allow a minimum separation of 
    12 inches (30.5 cm) between the hot air exhaust on one chassis and 
    the air intake on another chassis. Failure to maintain adequate air 
    space can cause the chassis to overheat and the system to fail. On 
    Catalyst chassis in which the airflow is from front to back, the 
    chassis may be placed side-by-side. 
    1. RU = rack units
    Table 1-2 Catalyst 6503 Switch Specifications (continued)
    Item Specification 
    						
    							1-8
    Catalyst 6500 Series Switches Installation Guide
    OL-5781-08
    Chapter 1      Product Overview
      Catalyst 6503-E Switch
    Catalyst 6503-E Switch
    The Catalyst 6503-E switch is an enhanced version of the Catalyst 6503 switch. The 3-slot horizontal 
    chassis supports redundant power supplies, redundant supervisor engines, and slots for up to two 
    modules. It also supports a greater power capacity per slot than the Catalyst6503 switch chassis. The 
    Catalyst 6503-E switch chassis is NEBS L3 compliant. Figure 1-3 shows the front view of the chassis 
    and Figure 1-4 shows the rear view of the chassis. 
    Figure 1-3 Catalyst 6503-E Switch—Front View
    Figure 1-4 Catalyst 6503-E Switch—Rear View
    91239
    Slots 1-3
    (top to bottom) Fan assemblyPEM 1 PEM 2
    ESD ground
    strap connection
    Supervisor
    Engine
    Modules
    W
    S-X6516-G
    E
    -T X
     
    16 PO
    R
    T 1000 B
    ASE
    -T GE1234567
    8910
    111213 141516
    LINK
    LINK
    LINK
    LINK
    LINK
    LINK
    LINK
    LINK
    LINK
    LINK
    LINK
    LINK
    LINK LINK
    LINK
    LINK
    W
    S-X6516-GE
    -T X 
    16 PO
    RT 1000 BA
    SE-T G
    E12345
    67
    8910
    111213 141516
    LINK
    LINK
    LINK
    LINK
    LINK
    LINK
    LINK
    LINK
    LINK
    LINK
    LINK
    LINK
    LINK LINK
    LINK
    LINK
    W
    S-S
    UP
    32-G
    E-3B
    ST
    A
    T
    US
    SYST
    EM
    ACTIVE
    PWR MGMT
    RESETCAT
    ALYST  
     6500
     SUPER
    VIS
    OR  
    ENGI
    NE
      
    32CO
    NSO
    LE
    EJECTDISK 0PORT 
    1
    PO
    RT 2
    PO
    RT 
    3
    P
    O
    RT 4PO
    RT 5
    PO
    RT 
    6
    PO
    RT 
    7PO
    R
    T 8P
    ORT 9
    USB 
    2.
    0
    LI
    NK
    LINK
    LI
    NK
    LI
    NK
    LI
    NK
    LINK
    LI
    NK
    LIN
    K
    LINK
    63031 
    INPUT
    OKFA N
    OKOUTPUT
    FA I L
    INPUT
    OKFA N
    OKOUTPUT
    FA I L
    Power supply 2
    (redundant)
    Power supply 1 
    						
    All Cisco manuals Comments (0)

    Related Manuals for Cisco 6500e Manual