1-19 Catalyst 6500 Series Switches Installation Guide OL-5781-08 Chapter 1 Product Overview Catalyst 6506 Switch Ta b l e 1 - 7 lists the features of the Catalyst 6506 switch chassis. Table 1-7 Catalyst 6506 Switch Features Feature Descriptions Chassis Six horizontal slots. Slots are numbered from 1 (top) to 6 (bottom). Supervisor engines Supports Supervisor Engine 2, Supervisor Engine 32, Supervisor Engine 32 PISA, Supervisor Engine 720, and Supervisor Engine 720-10GE. NoteRefer to your software release notes for the minimum software release versions required to support the supervisor engines. –Supervisor Engine 2 must be installed in slot 1 or slot 2. –Supervisor Engine 32, Supervisor Engine 32 PISA, Supervisor Engine 720, and Supervisor Engine 720-10GE must be installed in slot 5 or slot 6. NoteSlots not occupied by supervisor engines can be used for modules. Check your software release notes for any restrictions on the type of module that can be installed. Supervisor Engine 32, Supervisor Engine 32 PISA, Supervisor Engine 720, and Supervisor Engine 720-10GE all require the high-speed fan tray (WS-C6K-6SLOT-FAN2) be installed in the chassis. You must also install a 2500 W or higher capacity power supply in the chassis to power the high-speed fan tray. NoteThe 2500 W power supply, when supporting the high-speed fan tray, can be powered from either 120 VAC or 220 VAC. Supervisor Engine 720 and Supervisor Engine 720-10GE have a built-in switching fabric. Switch Fabric Modules (WS-C6500-SFM and WS-X6500-SFM2) are not supported by Supervisor Engine 720 and Supervisor Engine 720-10GE. Supervisor Engine 32 and Supervisor Engine 32 PISA do not support the Switch Fabric Modules (WS-C6500-SFM and WS-X6500-SFM2). The uplink ports are fully functional on the redundant supervisor engine in standby mode. NoteIn systems with redundant supervisor engines, both supervisor engines must be the same model and have the same daughter card configurations. Each supervisor engine must have the resources to run the switch on its own, which means that all supervisor engine resources are duplicated. Identical supervisor engine memory configurations are recommended, but are not required as long as the supervisor engine with the smaller memory configuration is sufficient to run the configured features of the switch. Additionally, each supervisor engine must have its own flash device and console port connections.
1-20 Catalyst 6500 Series Switches Installation Guide OL-5781-08 Chapter 1 Product Overview Catalyst 6506 Switch ModulesSupports up to five Catalyst 6500 series modules. WS-C6500-SFM and WS-X6500-SFM2 Switch Fabric Modules must be installed in slot 5 or slot 6. NoteMixing WS-C6500-SFM and WS-X6500-SFM2 Switch Fabric Modules in the Catalyst 6506 chassis is allowed. Some Catalyst 6500 series modules may: –Not be supported –Require that you install a Supervisor Engine 720 –Have chassis slot restrictions –Require a specific software release level to operate NoteCheck your software release notes for specific information on module support and restrictions. Backplane bandwidth 32 GBps shared bus. 256 GBps switch fabric. 720 GBps switch fabric. Clock and VTT modules Two replaceable clock modules (WS-C6K-CL=) provide clocking signals to the EOBC channel and the switching bus. Three replaceable voltage termination (VTT) modules (WS-C6K-VTT=) provide reference voltage for bus signals. Fan tray The chassis supports one hot-swappable fan tray. Two fan tray models are available: –WS-C6K-6SLOT-FAN (Standard fan tray—227 CFM). Supports Supervisor Engine 1 and Supervisor Engine 2 only; does not support Supervisor Engine 32 or Supervisor Engine 720. –WS-C6K-6SLOT-FAN2 (Optional high-speed fan tray—420 CFM. Required for Supervisor Engine 32 and Supervisor Engine 720. Supports Supervisor Engine 1 and Supervisor Engine 2. NoteYou must install a 2500 W or higher capacity power supply in the chassis to power the high-speed fan tray. The 2500 W power supply can be powered from either 120 VAC or 220 VAC. NoteThe fan trays contains six individual fans. The individual fans are not field replaceable; you must replace the fan tray in the event of a fan failure. Fan tray STATUS LED –Red—One or more individual fans have failed. –Green—Fan tray is operating normally. Table 1-7 Catalyst 6506 Switch Features (continued) Feature Descriptions
1-21 Catalyst 6500 Series Switches Installation Guide OL-5781-08 Chapter 1 Product Overview Catalyst 6506 Switch Power supplySupports one or two power supplies. The following power supplies are supported: –WS-CAC-1000W (1000 W AC-input power supply). –WS-CAC-1300W (1300 W AC-input power supply). –WS-CDC-1300W (1300 W DC-input power supply). –WS-CAC-2500W (2500 W AC-input power supply). –WS-CDC-2500W (2500 W DC-input power supply). –WS-CAC-3000W (3000 W AC-input power supply). –WS-CAC-4000W-US (4000 W AC-input power supply). –WS-CAC-4000W-INT (4000 W AC-input power supply). –PWR-4000-DC (4000 W DC-input power supply). –WS-CAC-6000W (6000 W AC-input power supply). –PWR-6000-DC (6000 W DC-input power supply). –WS-CAC-8700W (8700 W AC-input power supply). NoteThe 6000 W AC-input and DC-input power supplies, and the 8700 W AC-input power supply are limited to 4000 W maximum output when installed in the Catalyst 6506 chassis. Installed power supplies can be of different wattage ratings. Installed power supplies can also be both AC-input, both DC-input, or one AC-input and one DC-input. Power supplies can be configured in either redundant or combined mode. All Catalyst 6500 series AC-input power supplies require single-phase source AC. Source AC can be out of phase between multiple power supplies or multiple AC-power plugs on the same power supply because all AC power supply inputs are isolated. Single power supplies are installed in the left power supply bay. The second power supply is installed in the right power supply bay. You must install a 2500 W or higher capacity power supply when using the Supervisor Engine 32 or the Supervisor Engine 720 and the high-speed fan tray. NoteFor proper operation of the power supply OUTPUT FAIL LED, systems with single power supplies must be configured with a minimum of one fan tray and one supervisor engine. Systems with dual power supplies must have a minimum configuration of one fan tray, one supervisor engine, and one additional module. Failure to meet these minimum configuration requirements can cause a false power supply output fail signal. Table 1-7 Catalyst 6506 Switch Features (continued) Feature Descriptions
1-22 Catalyst 6500 Series Switches Installation Guide OL-5781-08 Chapter 1 Product Overview Catalyst 6506 Switch Ta b l e 1 - 8 lists the environmental and physical specifications of the Catalyst6506 switch chassis. Table 1-8 Catalyst 6506 Switch Specifications Item Specification Environmental Temperature, operating Certified for operation: 32° to 104°F (0° to 40°C) Designed and tested for operation: 32° to 130°F (0° to 55°C) NoteThe Catalyst 6500 series switches are equipped with internal air temperature sensors that are triggered at 104°F (40°C) generating a minor alarm and at 131°F (55°C) generating a major alarm. Temperature, nonoperating and storageChassis unpackaged: –4° to 149°F (–20° to 65°C) Chassis in protective shipping package: –40° to 158°F (–40° to 70°C) Thermal transition 0.5°C per minute (hot to cold) 0.33°C per minute (cold to hot) Humidity (RH), ambient (noncondensing) operating 5% to 90% Humidity (RH), ambient (noncondensing) nonoperating and storage 5% to 95% Altitude, operating Certified for operation: 0 to 6500 ft (0 to 2000 m) Designed and tested for operation: –200 to 10,000 ft (–60 to 3000 m) Shock and vibration This switch complies with Network Equipment Building Systems (NEBS) (Zone 4 per GR-63-Core) in the following areas: Earthquake environment and criteria Office vibration and criteria Transportation vibration and criteria Shock Operational—5 G 30 ms, half-sine (IEC 68-2-27) Nonoperational—20 G, 7.5 ms, trapezoidal Vibration Operational—3 Hz to 500 Hz. Power Spectral Density (PSD)—0.0005 G2/Hz at 10 Hz and 200 Hz. 5 dB/octave roll off at each end. 0.5 hours per axis (1.12 Grms). Acoustic noise 53 to 61 dB. International Organization for Standardization (ISO) 7779: Bystander position operating to an ambient temperature of 86°F (30°C).
1-23 Catalyst 6500 Series Switches Installation Guide OL-5781-08 Chapter 1 Product Overview Catalyst 6506 Switch Physical characteristics Dimensions (H x W x D) 20.1 x 17.2 x 18.2 in. (51.1 x 43.7 x 46.0 cm). Chassis depth including cable guide is 21.64 in. (55.0 cm). Chassis requires 12 RU. The Catalyst 6506 switch chassis is designed to install in standard 19-inch equipment racks that meet ANSI/EIA 310-D, IEC 60297, and ETS 300-119 standards. Weight Chassis only: 45 lb (20.4 kg). Chassis fully configured with 1 supervisor engine, 5 switching modules, and 2 power supplies: 156.6 lb (71.0 kg). Airflow WS-C6K-6SLOT-FAN (Standard fan tray)—227 CFM. WS-C6K-6SLOT-FAN2 (Optional high-speed fan tray)—420 CFM. NoteTo maintain proper air circulation through the Catalyst switch chassis, we recommend that you maintain a minimum 6-inch (15 cm) separation between a wall and the chassis air intake or a wall and the chassis air exhaust. You should also allow a minimum separation of 12 inches (30.5 cm) between the hot air exhaust on one chassis and the air intake on another chassis. Failure to maintain adequate air space can cause the chassis to overheat and the system to fail. On Catalyst chassis in which the airflow is from front to back, the chassis may be placed side-by-side. Table 1-8 Catalyst 6506 Switch Specifications (continued) Item Specification
1-24 Catalyst 6500 Series Switches Installation Guide OL-5781-08 Chapter 1 Product Overview Catalyst 6506-E Switch Catalyst 6506-E Switch The Catalyst 6506-E switch is an enhanced version of the Catalyst 6506 switch. The 6-slot horizontal chassis supports redundant power supplies, redundant supervisor engines, and slots for up to five modules. It also supports a greater power capacity per slot than the Catalyst6506 switch chassis. The Catalyst 6506-E switch chassis is NEBS L3 compliant. Figure 1-8 shows a front view of the Catalyst 6506-E switch. Figure 1-8 Catalyst 6506-E Switch Table 1-9 lists the features of the Catalyst 6506-E switch chassis. 18224 INPUT OKFA N OKOUTPUT FA I L o INPUT OKFA N OKOUTPUT FA I L o 1 2 3 FA N STATUS 4 5 68 P O R T G IG A B IT E TH E R N E TWS-X64081LINKSTA TUS2 3 4 5 6 7 8LINKLINKLINKLINKLINKLINKLINK 8 P O R T G IG A B IT E TH E R N E TWS-X64081LIN KSTA TUS2 3 4 5 6 7 8LI NKLINKLINKLIN KLI NKLI NKLI NK 8 P O R T G IG A B IT E TH E R N E TWS-X64081LIN KSTA TUS2 3 4 5 6 7 8LI NKLINKLINKLIN KLI NKLI NKLI NK 8 P O R T G IG A B IT E TH E R N E TWS-X64081LINKSTA TUS2 3 4 5 6 7 8LINKLINKLINKLINKLINKLINKLINKW S -S U P 32- G E-3 BST AT U S SYSTEM ACT IVE PW R MGM T R ESETC ATA L Y S T 65 00 SUP ER V IS O R E N G IN E 3 2C ONSOLE EJEC TD ISK 0PORT 1 PORT 2 PORT 3 PORT 4PORT 5 POR T 6 PO RT 7PO RT 8POR T 9 USB 2.0 LIN K L INK L I NK LI NK LI NK LI NK LI NK LIN K LINKW S -S U P 32- G E-3 BST AT U S SYSTEM ACT IVE PW R MG M T R ESETC AT A L Y S T 65 00 S UP ER V IS O R E N G IN E 3 2CONSOLE EJECTD ISK 0PORT 1 PORT 2 PORT 3 PORT 4PORT 5 PORT 6 PO RT 7PO RT 8POR T 9 USB 2.0 LINK L IN K L I NK LI NK LI NK LI NK LI NK LINK LINK Fan assembly Supervisor engine Redundant supervisor engine Switching modules Power supply 2 (redundant)Power supply 1 ESD ground strap connector
1-25 Catalyst 6500 Series Switches Installation Guide OL-5781-08 Chapter 1 Product Overview Catalyst 6506-E Switch Table 1-9 Catalyst 6506-E Switch Features Feature Descriptions Chassis Six horizontal slots. Slots are numbered from 1 (top) to 6 (bottom). Supervisor engines Supports Supervisor Engine 2, Supervisor Engine 32, Supervisor Engine 32 PISA, Supervisor Engine 720, Supervisor Engine 720-10GE, and Supervisor Engine 2T. NoteRefer to your software release notes for the minimum software release versions required to support the supervisor engines. –Supervisor Engine 2 must be installed in slot 1 and slot 2. –Supervisor Engine 32, Supervisor Engine 32 PISA, Supervisor Engine 720, Supervisor Engine 720-10GE, and Supervisor Engine 2T must be installed in slot 5 and slot 6. NoteSlots not occupied by supervisor engines can be used for modules. Check your software release notes for any restrictions on the type of module that can be installed. Supervisor Engine 720, Supervisor Engine 720-10GE, and Supervisor Engine 2T have a built-in switching fabric. Switch Fabric Modules (WS-C6500-SFM and WS-X6500-SFM2) are not supported. Supervisor Engine 32 and Supervisor Engine 32 PISA do not support the Switch Fabric Modules (WS-C6500-SFM and WS-X6500-SFM2). The uplink ports are fully functional on the redundant supervisor engine in standby mode. NoteIn systems with redundant supervisor engines, both supervisor engines must be the same model and have the same daughter card configurations. Each supervisor engine must have the resources to run the switch on its own, which means that all supervisor engine resources are duplicated. Identical supervisor engine memory configurations are recommended, but are not required as long as the supervisor engine with the smaller memory configuration is sufficient to run the configured features of the switch. Additionally, each supervisor engine must have its own flash device and console port connections.
1-26 Catalyst 6500 Series Switches Installation Guide OL-5781-08 Chapter 1 Product Overview Catalyst 6506-E Switch ModulesSupports up to five Catalyst 6500 series modules. WS-C6500-SFM and WS-X6500-SFM2 Switch Fabric Modules must be installed in slot 5 or slot 6. NoteMixing WS-C6500-SFM and WS-X6500-SFM2 Switch Fabric Modules in the Catalyst 6506-E chassis is allowed. Some Catalyst 6500 series modules may: –Not be supported –Require that you install a Supervisor Engine 720 –Have chassis slot restrictions –Require a specific software release level to operate NoteCheck your software release notes for specific information on module support and restrictions. Backplane bandwidth 32 GBps shared bus. 256 GBps switch fabric. 720 GBps switch fabric. Clock and VTT modules Two replaceable clock modules (CLK-7600=) provide clocking signals to the EOBC channel and the switching bus. Three replaceable voltage termination (VTT) modules (WS-C6K-VTT-E=) provide reference voltage for bus signals. Fan tray The chassis supports one hot-swappable fan tray. One fan tray model is available: –WS-C6506-E-FAN—564 CFM NoteYou must install a 2500 W or higher capacity power supply in the chassis to power the fan tray. The 2500 W power supply can be powered from either 120 VAC or 220 VAC. NoteThe fan tray contains six individual fans. The individual fans are not field replaceable; you must replace the fan tray in the event of a fan failure. Fan tray STATUS LED –Red—One or more individual fans have failed. –Green—Fan tray is operating normally. Table 1-9 Catalyst 6506-E Switch Features (continued) Feature Descriptions
1-27 Catalyst 6500 Series Switches Installation Guide OL-5781-08 Chapter 1 Product Overview Catalyst 6506-E Switch Power supplySupports one or two power supplies. The following power supplies are supported: –WS-CAC-2500W (2500 W AC-input power supply). –WS-CDC-2500W (2500 W DC-input power supply). –WS-CAC-3000W (3000 W AC-input power supply). –WS-CAC-4000W-US (4000 W AC-input power supply). –WS-CAC-4000W-INT (4000 W AC-input power supply). –PWR-4000-DC (4000 W DC-input power supply). –WS-CAC-6000W (6000 W AC-input power supply). –PWR-6000-DC (6000 W DC-input power supply). –WS-CAC-8700W-E (8700 W AC-input power supply). Installed power supplies can be of different wattage ratings. Installed power supplies can also be both AC-input, both DC-input, or one AC-input and one DC-input. Power supplies can be configured in either redundant or combined mode. All Catalyst 6500 series AC-input power supplies require single-phase source AC. Source AC can be out of phase between multiple power supplies or multiple AC-power plugs on the same power supply because all AC power supply inputs are isolated. Single power supplies are installed in the left power supply bay. The second power supply is installed in the right power supply bay. Supervisor Engine 2T requires a 3000 W or greater power supply to operate. NoteFor proper operation of the power supply OUTPUT FAIL LED, systems with single power supplies must be configured with a minimum of one fan tray and one supervisor engine. Systems with dual power supplies must have a minimum configuration of one fan tray, one supervisor engine, and one additional module. Failure to meet these minimum configuration requirements can cause a false power supply output fail signal. Table 1-9 Catalyst 6506-E Switch Features (continued) Feature Descriptions
1-28 Catalyst 6500 Series Switches Installation Guide OL-5781-08 Chapter 1 Product Overview Catalyst 6506-E Switch Table 1-10 lists the environmental and physical specifications of the Catalyst 6506-E switch chassis. Table 1-10 Catalyst 6506-E Switch Specifications Item Specification Environmental Temperature, operating Certified for operation: 32° to 104°F (0° to 40°C) Designed and tested for operation: 32° to 131°F (0° to 55°C) NoteThe Catalyst 6500 series switches are equipped with internal air temperature sensors that are triggered at 104°F (40°C) generating a minor alarm and at 131°F (55°C) generating a major alarm. Temperature, nonoperating and storageChassis unpackaged: –4° to 149°F (–20° to 65°C) Chassis in protective shipping package: –40° to 158°F (–40° to 70°C) Thermal transition 0.5°C per minute (hot to cold) 0.33°C per minute (cold to hot) Humidity (RH), ambient (noncondensing) operating 5% to 90% Humidity (RH), ambient (noncondensing) nonoperating and storage 5% to 95% Altitude, operating Certified for operation: 0 to 6500 ft (0 to 2000 m) Designed and tested for operation: –200 to 10,000 ft (–60 to 3000 m) Shock and vibration This switch complies with Network Equipment Building Systems (NEBS) (Zone 4 per GR-63-Core) in the following areas: Earthquake environment and criteria Office vibration and criteria Transportation vibration and criteria Shock Operational—5 G 30 ms, half-sine (IEC 68-2-27) Nonoperational—20 G, 7.5 ms, trapezoidal Vibration Operational—3 Hz to 500 Hz. Power Spectral Density (PSD)—0.0005 G2/Hz at 10 Hz and 200 Hz. 5 dB/octave roll off at each end. 0.5 hours per axis (1.12 Grms). Acoustic noise 53 to 61 dB. International Organization for Standardization (ISO) 7779: Bystander position operating to an ambient temperature of 86°F (30°C).