Cisco 6500e Manual
Have a look at the manual Cisco 6500e Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 53 Cisco manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.
A-31 Catalyst 6500 Series Switches Installation Guide OL-5781-08 Appendix A Power Supply Specifications 2700 W AC-Input and DC-Input Power Supplies 2700 W Power Supply Specifications Ta b l e A - 2 2 lists the specifications for the 2700 W AC-input power supply. Table A-21 2700 W AC-Input Power Supply Specifications Specification Description AC-input type Autoranging input with power factor correction (PFC). NotePower factor correction is a standard feature on all Catalyst 6500 series AC-input power supplies. PFC reduces the reactive component in the source AC current allowing higher power factors (typically 99 percent or better) and lower harmonic current components. AC-input voltage Low-line (120 VAC nominal)—90 VAC (min) to 132 VAC (max) High-line (230 VAC nominal)—170 VAC (min) to 264 VAC (max) AC-input current 16 A maximum at 230 VAC at 2700 W output 16 A maximum at 120 VAC at 1350 W output AC-input frequency 50/60 Hz (nominal) (±3% for full range) Branch circuit requirement Each chassis power supply should have its own dedicated, fused-branch circuit: For North America—20 A For International—Circuits sized to local and national codes All AC power supply inputs are fully isolated. –Source AC can be out of phase between multiple power supplies in the same chassis, which means that PS1 can be operating from phase A and PS2 can be operating from phase B. –For high-line operation, the power supply operates with the hot conductor wired to a source AC phase and the neutral conductor wired either to ground or to another source AC phase as long as the net input voltage is in the range of 170 to 264 VAC. –Source AC can be out of phase between AC inputs on power supplies that are equipped with multiple AC inputs, which means that power cord 1 can be plugged into phase A and power cord 2 can be plugged into phase B. Power supply output capacity 1350 W maximum (100–120 VAC) 2700 W maximum (200–240 VAC)
A-32 Catalyst 6500 Series Switches Installation Guide OL-5781-08 Appendix A Power Supply Specifications 2700 W AC-Input and DC-Input Power Supplies Ta b l e A - 2 2 lists the 2700 W DC-input power supply specifications. Power supply output 100/120 VAC operation –15 A @ +1.5 VDC –2.5 A @ +3.3 VDC –27.49 A @ +50 VDC 200/240 VAC operation –15 A @ +1.5 VDC –2.5 A @ +3.3 VDC –55.61 A @ +50 VDC Output holdup time 20 ms minimum kVA rating 13.4 KVA (high-line operation) Heat dissipation 10,841 BTU/hour (approx.) Weight 18.5 lb (8.4 kg) 1. The kVA rating listed for the power supply should be used as the sizing criteria for both UPS outputs as well as standard circuits and transformers to power a switch. Table A-21 2700 W AC-Input Power Supply Specifications (continued) Specification Description Table A-22 2700 W DC-Input Power Supply Specifications Specification Description DC-input voltage –48 VDC @ 37 A for nominal –48 V battery backup system (operating range: –40.5 VDC to –56 VDC) –60 VDC @ 29 A for nominal –60 V battery backup system (operating range: –55 VDC to –72 VDC) DC-input current (per DC input) 43 A @ –40.5 VDC 37 A @ –48 VDC 29 A @ –60 VDC NoteFor multiple DC input power supplies, each DC input must be protected by a dedicated circuit breaker or a fuse. The circuit breaker or the fuse must be sized according to the power supply input power rating and any local or national electrical code requirements. Power supply output capacity 1350 W maximum (–48 to –60 VDC, with one DC input) 2700 W maximum (–48 to –60 VDC, with two DC inputs)
A-33 Catalyst 6500 Series Switches Installation Guide OL-5781-08 Appendix A Power Supply Specifications 2700 W AC-Input and DC-Input Power Supplies Ta b l e A - 2 3 lists the power supply LEDs and their meanings. Power supply output One DC input operation (1350 W operation) –15 A @ +1.5 VDC –5 A @ +3.3 VDC –27.49 A @ +50 VDC Two DC inputs operation (2700 W operation –15 A @ +1.5 VDC –5 A @ +3.3 VDC –55.61 A @ +50 VDC DC input terminal block Accepts 2–14 AWG copper conductors. Actual size of the wire needed is determined by the installer or local electrician. Terminal block material rated at 150°C. Output holdup time 4 ms kVA rating 13.5 KW Heat dissipation 11,968 BTU/hour (approx.) Weight 21.0 lb (9.5 kg) 1. The kVA rating listed for the power supply should be used as the sizing criteria for both UPS outputs as well as standard circuits and transformers to power a switch. Table A-22 2700 W DC-Input Power Supply Specifications (continued) Specification Description
A-34 Catalyst 6500 Series Switches Installation Guide OL-5781-08 Appendix A Power Supply Specifications 2700 W AC-Input and DC-Input Power Supplies Table A-23 2700 W AC-Input and DC-Input Power Supply LEDs LED Meaning INPUT 1 OK INPUT 2 OK (DC-input power supply only)AC-input power supplies: Green—Source AC voltage is OK. (Input voltage is 85 VAC or greater.) Off—Source AC voltage falls below 70 VAC, is not present, or the power supply is turned off. DC-input power supplies: Green—Source DC is OK. (Input voltage is –40.5 VDC or greater.) Off—Source DC voltage falls below –33 VDC, is not present, or the power supply is turned off. FAN OK Green—Power supply fan is operating properly. Off—Power supply fan failure is detected. OUTPUT FAIL Red—Problem with one or more of the DC-output voltages of the power supply. Off—DC-output voltages within acceptable margins. NoteFor proper operation of the OUTPUT FAIL LED, systems with single power supplies must be configured with a minimum of one fan tray and one supervisor engine. Systems with dual power supplies must have a minimum configuration of one fan tray, one supervisor engine, and one additional module. Failure to meet these minimum configuration requirements can cause a false power supply output fail signal.
A-35 Catalyst 6500 Series Switches Installation Guide OL-5781-08 Appendix A Power Supply Specifications 2700 W AC-Input and DC-Input Power Supplies 2700 W Power Supply AC Power Cords Ta b l e A - 2 4 lists the specifications for the AC power cords that are available for the 2700 W AC-input power supply. The table includes references to power cord illustrations. NoteAll 2700 W power supply power cords are 14 feet (4.3 meters) in length. NoteAll 2700 W power supply power cords have an IEC60320/C19 appliance connector at one end. TableA-24 2700W Power Supply AC Power Cords Locale Power Cord Part NumberAC Source Plug Type Cordset Rating Power Cord Reference Illustration Argentina CAB-7513ACR= or CAB-IR2073-C19-AR=IRAM 2073 16 A, 250 VACFigure A-31 Australia, New Zealand CAB-AC-16A-AUS= AU20S3 16 A, 250 VACFigure A-45 People’s Republic of China CAB-AC16A-CH= GB16C 16 A, 250 VACFigure A-37 Continental Europe CAB-AC-2500W-EU= CEE 7/7 16 A, 250 VACFigure A-41 International CAB-AC-2500W-INT= IEC 309 16 A, 250 VACFigure A-42 Israel CAB-AC-2500W-ISRL= SI16S3 16 A, 250 VACFigure A-34 Italy CAB-7513ACI= CEI 23-16/7 16 A, 250 VACFigure A-35 Japan, North America 200–240 VAC operationCAB-AC-2500W-US1= NEMA 6-20 (nonlocking plug)16 A, 250 VACFigure A-43 Japan, North America 200–240 VAC operationCAB-AC-C6K-TWLK= NEMA L6-20 (locking plug)16 A, 250 VACFigure A-44 Japan, North America 100–120 VAC operationCAB-7513AC= NEMA 5-20 20 A, 125 VACFigure A-36 Power Distribution Unit (PDU) 1 1. The PDU power cable is designed for users who power their switch from a PDU. The end of the cable that plugs into the chassis power supply has a C19 connector; the other end of the cable that connects to the PDU has a C20 connector. CAB-C19-CBN= IEC 60320 C19 IEC 60320 C2016 A, 250 VACFigure A-47 South Africa CAB-7513ACSA= IEC 884-1 16 A, 250 VACFigure A-38 Switzerland CAB-ACS-16= SEV 5934-2 Type 23 16 A, 250 VACFigure A-45
A-36 Catalyst 6500 Series Switches Installation Guide OL-5781-08 Appendix A Power Supply Specifications 3000 W AC-Input Power Supply 3000 W AC-Input Power Supply The 3000 W AC-input power supply (WS-CAC-3000W) is supported in the following Catalyst 6500 series switches: Catalyst 6506 Catalyst 6506-E Catalyst 6509 Catalyst 6509-E Catalyst 6509-NEB Catalyst 6509-NEB-A Catalyst 6509-V-E Catalyst 6513 Catalyst 6513-E The 3000 W power supply (see Figure A-13) shares the same form factor as the 1000 W, 1300 W, 2500 W, 4000 W, and 6000 W AC-input power supplies. NoteThe 3000 W AC-input power supply needs 220 VAC to deliver 3000 W of power. When operating with 110 VAC, it delivers only 1400 W. In addition, the power supply needs 16 A, regardless of whether it is plugged into 110 VAC or 220 VAC. Figure A-13 3000 W AC-Input Power Supply INPUT OKFA N OKOUTPUT FA I LOUTPUT 42V /17A42V /17AOK IINSTALLRUN O 110-120V - 15A 200-240V - 15A 60/50HZ + 105069 Power switch Cable retention deviceAC power connection Captive installation screwStatus LEDs (3) External power connector cover
A-37 Catalyst 6500 Series Switches Installation Guide OL-5781-08 Appendix A Power Supply Specifications 3000 W AC-Input Power Supply 3000 W Power Supply Specifications Ta b l e A - 2 5 lists the specifications for the 3000 W AC-input power supply. Table A-25 3000 W Power Supply Specifications Specification Description AC-input type Autoranging input with power factor correction (PFC). NotePower factor correction is a standard feature on all Catalyst 6500 series AC-input power supplies. PFC reduces the reactive component in the source AC current allowing higher power factors (typically 99 percent or better) and lower harmonic current components. AC-input voltage Low-line (120 VAC nominal)—90 VAC (min) to 132 VAC (max) High-line (230 VAC nominal)—170 VAC (min) to 264 VAC (max) AC-input current 16 A @ 200 VAC (3000 W output) 16 A @ 100 VAC (1400 W output) AC-input frequency 50/60 Hz (nominal) (±3% for full range) Branch circuit requirement Each chassis power supply should have its own dedicated, fused-branch circuit: For North America—20 A For International—Circuits sized to local and national codes All AC power supply inputs are fully isolated. –Source AC can be out of phase between multiple power supplies in the same chassis, which means that PS1 can be operating from phase A and PS2 can be operating from phase B. –For high-line operation, the power supply operates with the hot conductor wired to a source AC phase and the neutral conductor wired either to ground or to another source AC phase as long as the net input voltage is in the range of 170 to 264 VAC. –Source AC can be out of phase between AC inputs on power supplies that are equipped with multiple AC inputs, which means that power cord 1 can be plugged into phase A and power cord 2 can be plugged into phase B. Power supply output capacity 1400 W maximum (100–120 VAC) 3000 W maximum (200–240 VAC)
A-38 Catalyst 6500 Series Switches Installation Guide OL-5781-08 Appendix A Power Supply Specifications 3000 W AC-Input Power Supply Ta b l e A - 2 6 lists the power supply LEDs and their meanings. Power supply output 100/120 VAC operation –25.0 A @ +3.3 V –5A @ +5V –12 A @ +12 V –27.89 A @ +42 V 200/240 VAC operation –25.0 A @ +3.3 V –5A @ +5V –12 A @ +12 V –65.98 A @ +42 V Front panel power connectorA two-pin male Molex connector is located in the lower right corner of the power supply front panel. The connector provides 42 VDC at a maximum of 17 A. This connector provides power to the WS-6509-NEB-UPGRD kit fan assembly through a power harness also provided in the kit. A hinged protective flap secured by a captive screw covers the connector when it is not in use. Output holdup time 20 ms minimum kVA rating 13520 W (total input power) or 3.6 KVA (high-line operation) Heat dissipation 12,046 BTU/hour (approx.) Weight 15.8 lb (7.2 kg) 1. The kVA rating listed for the power supply should be used as the sizing criteria for both UPS outputs as well as standard circuits and transformers to power a switch. Table A-25 3000 W Power Supply Specifications (continued) Specification Description
A-39 Catalyst 6500 Series Switches Installation Guide OL-5781-08 Appendix A Power Supply Specifications 3000 W AC-Input Power Supply TableA-26 3000W AC-Input Power Supply LEDs LED Meaning INPUT OK Green—Source AC voltage is OK. (Input voltage is 85 VAC or greater.) Off—Source AC voltage falls below 70 VAC, is not present, or the power supply is turned off. FAN OK Green—Power supply fan is operating properly. Off—Power supply fan failure is detected. OUTPUT FAIL Red—Problem with one or more of the DC-output voltages of the power supply. Off—DC-output voltages within acceptable margins. NoteFor proper operation of the OUTPUT FAIL LED, systems with single power supplies must be configured with a minimum of one fan tray and one supervisor engine. Systems with dual power supplies must have a minimum configuration of one fan tray, one supervisor engine, and one additional module. Failure to meet these minimum configuration requirements can cause a false power supply output fail signal. 42V OK Green—42 VDC is present at the fan power connector. Off—42 VDC is not present at the fan power connector.
A-40 Catalyst 6500 Series Switches Installation Guide OL-5781-08 Appendix A Power Supply Specifications 3000 W AC-Input Power Supply 3000 W Power Supply AC Power Cords Ta b l e A - 2 7 lists the specifications for the AC power cords that are available for the 3000 W AC-input power supply. The table includes references to power cord illustrations. NoteAll 3000 W power supply power cords are 14 feet (4.3 meters) in length. NoteAll 3000 W power supply power cords have an IEC60320/C19 appliance connector at one end. TableA-27 3000W Power Supply AC Power Cords Locale Power Cord Part NumberAC Source Plug Type Cordset Rating Power Cord Reference Illustration Argentina CAB-7513ACR= or CAB-IR2073-C19-AR=IRAM 2073 16 A, 250 VACFigure A-31 Australia, New Zealand CAB-AC-16A-AUS= AU20S3 16 A, 250 VACFigure A-46 People’s Republic of China CAB-AC16A-CH= GB16C 16 A, 250 VACFigure A-37 Continental Europe CAB-AC-2500W-EU= CEE 7/7 16 A, 250 VACFigure A-41 International CAB-AC-2500W-INT= IEC 309 16 A, 250 VACFigure A-42 Israel CAB-AC-2500W-ISRL= SI16S3 16 A, 250 VACFigure A-34 Italy CAB-7513ACI= CEI 23-16/7 16 A, 250 VACFigure A-35 Japan, North America (nonlocking plug) 200–240 VAC operationCAB-AC-2500W-US1= NEMA 6-20 16 A, 250 VACFigure A-43 Japan, North America (locking plug) 200–240 VAC operationCAB-AC-C6K-TWLK= NEMAL6-20 16A, 250VACFigure A-44 Japan, North America 100–120 VAC operation 1 1. The 3000 W power supply operating on 110 VAC delivers 1400 W. CAB-7513AC= NEMA 5-20 20 A, 125 VACFigure A-36 Power Distribution Unit (PDU) 2 2. The PDU power cable is designed for users who power their switch from a PDU. The end of the cable that plugs into the chassis power supply has a C19 connector; the other end of the cable that connects to the PDU has a C20 connector. CAB-C19-CBN= IEC 60320 C19 IEC 60320 C2016 A, 250 VACFigure A-47 Switzerland CAB-ACS-16= SEV 5934-2 Type 23 16 A, 250 VACFigure A-45