Installing the cartridges / 81 P0603539 02Compact ICS 6.1 Installer Guide Installing Trunk Cartridges 1. Slide the Trunk Cartridge into slot 1, applying equal pressure at the top and bottom. See illustration on the next page. 2. Close the cartridge clips at the same time, to keep the cartridge aligned with the connector. 3. If you are installing a second trunk cartridge, remove the filler faceplate from slot 2 and slot 3 (it is one piece), using a screwdriver at the bottom of each slot and prying the bottom edge out. 4. Snap the two parts of the faceplate apart and put back the filler faceplate in slot 3. 5. Insert the second Trunk Cartridge, as described in steps 2 and 3. Global Analog Trunk Cartridge/CLI Cartridge These cartridges have dip switches that may need to be set if your system is not running with the North American profile (Profile 1). Set the dip switches before you install the cartridge. GATC dip switch settings (default is North America)( The following table lists the various dip switch settings. However, for this release, only the North America, Taiwan, and Australia settings are active. DIP switch settingCountry profile 00000000North America 10000000Taiwan 01000000Australia 11000000*Chili 00100000*Peru 10100000*Argentina 01100000*Mexico
82 / Installing the cartridges Compact ICS 6.1 Installer GuideP0603539 02 11100000*Sweden 00010000*South America 10010000*Brazil 01010000*Norway 11010000*France 00110000*Germany 10110000*Korea XXXXXXX1*Reserved XXXXXX1X*Reserved XXXXX1XX*Reserved * Reserved for future development DIP switch settingCountry profile
Installing the cartridges / 83 P0603539 02Compact ICS 6.1 Installer Guide
84 / Installing the cartridges Compact ICS 6.1 Installer GuideP0603539 02 Installing the Expansion Cartridge The Expansion Cartridge must be equipped with clock control if you are installing BRI Cards. 1. Remove the filler faceplate from slot 3 (and slot 2 if there is no Trunk Cartridge), using a screwdriver to pry the bottom edge(s) out. 2. If required, snap the two parts of the faceplate apart and put back the filler faceplate in slot 2. 3. Slide the Expansion Cartridge into slot 3, applying equal pressure at the top and bottom. See illustration on page 86. 4. Close the cartridge clips at the same time, to keep the cartridge aligned with the connector. Expansion CartridgeExpansion Cartridge with ClockingClocking Cartridge
Installing the cartridges / 85 P0603539 02Compact ICS 6.1 Installer Guide Removing the expansion cartridge will cause a cold restart. If you downsize the system by removing the expansion cartridge, all system programming will be lost. Alarm Telephone will indicate a cold reset. An alarm and a prompt indicating warm or cold reset will occur on the alarm telephone when the system size has been decreased.
86 / Installing the cartridges Compact ICS 6.1 Installer GuideP0603539 02 Installing the Expansion Cartridge
Connecting the wiring / 87 P0603539 02Compact ICS 6.1 Installer Guide Connecting the wiring Connecting the wiring for a Compact ICS Extend 150 mm (6 in.) and clamp before bringing cables together. Do not attach central office or station line connections until power is connected to the ICS.
88 / Connecting the wiring Compact ICS 6.1 Installer GuideP0603539 02 Connecting the wiring to the distribution panel 1. Route the cables from the ICS to the distribution panel. 2. Bundle the cables with cable ties and secure them to the wall to support their weight. 3. Connect the telephone and auxiliary equipment wires to the appropriate pins on the distribution block (refer to the wiring charts). 4. Cross-connect the ICS telephone and auxiliary equipment wiring to the corresponding station pins on the distribution block. 5. Using a single pair of wires for each telephone, connect each of the telephones according to the wiring charts. 6. Cross-connect the external lines to the distribution block (refer to the wiring charts). Wiring charts Port numbering on the wiring charts The port number listed on the wiring charts is useful in tracking down faults during a Maintenance session where error codes appear on a Norstar telephone display. Refer to Maintenance on page 305 for more information. For example, the code 112 appearing as part of an error message indicates that the problem is with the telephone connected to the system at port 112. The corresponding pins on the distribution block are pin 37 (black-orange) and pin 12 (orange-black). Integrated Communications System (ICS) In the charts on the following pages, notice that the ICS has two 25-pair connectors. One handles telephones and auxiliary ringer. The other handles lines, I-ATA, music, and page.
Connecting the wiring / 89 P0603539 02Compact ICS 6.1 Installer Guide B1 and B2 directory numbers (DNs) Norstar has a B1 and B2 channel for transmitting voice and data. Each telephone port on the ICS has a B1 DN and a B2 DN. Devices such as the Business Series Terminals, and Norstar telephones use only the B1 DN. Other devices may need both B1 and B2 channels, therefore, requiring B1 and B2 DNs. Norstar Compact ICS uses different numbering schemes for the B1 and B2 DNs, depending on how you upgrade your system and when an Expansion Cartridge is added. See the tables below for details. ICS numbering (restricted feature cartridge) ICS numbering (restricted feature cartridge, expanded) Connector #DevicePortsB1 DNB2 DN ICS (#1)Telephones 1-8 I-ATA I-RAD101-108 117 11821-28 29 (I-ATA) 30 (I-RAD)31-38 39 40 ICS (#2)Lines 001-004201-204— —— — Connector #DevicePortsB1 DNB2 DN ICS (#1)Telephones 1-8 I-ATA I-RAD Telephones 9-16101-108 117 118 109-11621-28 29 (I-ATA) 30 (I-RAD) 41-4831-38 39 40 49-56 ICS (#2)Analog: Lines 001-004 Lines 031-034 BRI: Lines 001-008 Lines 031-038 201-204 231-234 201-208 225-232 (Profile 1, 3, 4) 231-238 (Profile 2)— — — — — — — —— — — — — — — —
90 / Connecting the wiring Compact ICS 6.1 Installer GuideP0603539 02 ICS numbering (restricted feature cartridge, expanded): Expansion Cartridge added ICS numbering (standard feature cartridge) ICS numbering (standard feature cartridge): Expansion Cartridge added at installation ICS numbering (standard feature cartridge): Expansion Cartridge added later Connector #DevicePortsB1 DNB2 DN ICS (#1)Telephones 1-8 I-ATA I-RAD Telephones 9-16 Telephones17-24101-108 117 118 109-116 119-12621-28 29 (I-ATA) 30 (I-RAD) 41-48 57-6431-38 39 40 49-56 65-72 Connector #DevicePortsB1 DNB2 DN ICS (#1)Telephones 1-16 I-ATA I-RAD101-116 117 11821-36 37 (I-ATA) 38 (I-RAD)39-54 55 56 Connector #DevicePortsB1 DNB2 DN ICS (#1)Telephones 1- 16 I-ATA I-RAD Telephones 17-24101-116 117 118 119-12621-36 37 (I-ATA) 38 (I-RAD) 39-4647-62 63 64 65-72 Connector #DevicePortsB1 DNB2 DN