    							Installing the cartridges / 81
    P0603539  02Compact ICS 6.1 Installer Guide
    Installing Trunk Cartridges   
    1. Slide the Trunk Cartridge into slot 1, applying equal pressure at the top 
    and bottom. See illustration on the next page.
    2. Close the cartridge clips at the same time, to keep the cartridge aligned 
    with the connector.
    3. If you are installing a second trunk cartridge, remove the filler 
    faceplate from slot 2 and slot 3 (it is one piece), using a screwdriver at 
    the bottom of each slot and prying the bottom edge out.
    4. Snap the two parts of the faceplate apart and put back the filler 
    faceplate in slot 3.
    5. Insert the second Trunk Cartridge, as described in steps 2 and 3.
    Global Analog Trunk Cartridge/CLI Cartridge
    These cartridges have dip switches that may need to be set if your system 
    is not running with the North American profile (Profile 1). Set the dip 
    switches before you install the cartridge.
    GATC dip switch settings (default is North America)(
    The following table lists the various dip switch settings. 
    However, for this release, only the North America, Taiwan, 
    and Australia settings are active.
    DIP switch settingCountry profile
    00000000North America
    10000000Taiwan
    01000000Australia
    11000000*Chili
    00100000*Peru
    10100000*Argentina
    01100000*Mexico 
    						
    							82 / Installing the cartridges
    Compact ICS 6.1 Installer GuideP0603539  02
    11100000*Sweden
    00010000*South America
    10010000*Brazil
    01010000*Norway
    11010000*France
    00110000*Germany
    10110000*Korea
    XXXXXXX1*Reserved
    XXXXXX1X*Reserved
    XXXXX1XX*Reserved
    * Reserved for future development
    DIP switch settingCountry profile 
    						
    							Installing the cartridges / 83
    P0603539  02Compact ICS 6.1 Installer Guide
                   
    						
    							84 / Installing the cartridges
    Compact ICS 6.1 Installer GuideP0603539  02
    Installing the Expansion Cartridge   
    The Expansion Cartridge must be equipped with clock control if you are 
    installing BRI Cards.
    1. Remove the filler faceplate from slot 3 (and slot 2 if there is no Trunk 
    Cartridge), using a screwdriver to pry the bottom edge(s)  out.
    2. If required, snap the two parts of the faceplate apart and put back the 
    filler faceplate in slot 2.
    3. Slide the Expansion Cartridge into slot 3, applying equal pressure at 
    the top and bottom. See illustration on page 86.
    4. Close the cartridge clips at the same time, to keep the cartridge aligned 
    with the connector.
     
    Expansion CartridgeExpansion Cartridge
    with ClockingClocking Cartridge 
    						
    							Installing the cartridges / 85
    P0603539  02Compact ICS 6.1 Installer Guide
      
     
    Removing the expansion cartridge will cause 
    a cold restart.
    If you downsize the system by removing the 
    expansion cartridge, all system programming will 
    be lost.
    Alarm Telephone will indicate a cold reset.
    An alarm and a prompt indicating warm or cold 
    reset will occur on the alarm telephone when the 
    system size has been decreased.  
    						
    							86 / Installing the cartridges
    Compact ICS 6.1 Installer GuideP0603539  02
    Installing the Expansion Cartridge 
    						
    							Connecting the wiring / 87
    P0603539  02Compact ICS 6.1 Installer Guide
    Connecting the wiring
    Connecting the wiring for a Compact ICS
    Extend 150 mm (6 in.) 
    and clamp before bringing
    cables together.
    Do not attach central office
    or station line connections until
    power is connected to the ICS. 
    						
    							88 / Connecting the wiring
    Compact ICS 6.1 Installer GuideP0603539  02
    Connecting the wiring to the distribution panel
    1. Route the cables from the ICS to the distribution panel.
    2. Bundle the cables with cable ties and secure them to the wall to support 
    their weight.
    3. Connect the telephone and auxiliary equipment wires to the 
    appropriate pins on the distribution block (refer to the wiring charts).
    4. Cross-connect the ICS telephone and auxiliary equipment wiring to 
    the corresponding station pins on the distribution block.
    5. Using a single pair of wires for each telephone, connect each of the 
    telephones according to the wiring charts.
    6. Cross-connect the external lines to the distribution block (refer to the 
    wiring charts).
    Wiring charts
    Port numbering on the wiring charts
    The port number listed on the wiring charts is useful in tracking down 
    faults during a Maintenance session where error codes appear on a Norstar 
    telephone display. Refer to Maintenance on page 305 for more 
    information.
    For example, the code 112 appearing as part of an error message indicates 
    that the problem is with the telephone connected to the system at port 112. 
    The corresponding pins on the distribution block are pin 37 (black-orange) 
    and pin 12 (orange-black).
    Integrated Communications System (ICS)
    In the charts on the following pages, notice that the ICS has two 25-pair 
    connectors. One handles telephones and auxiliary ringer. The other handles 
    lines, I-ATA, music, and page. 
    						
    							Connecting the wiring / 89
    P0603539  02Compact ICS 6.1 Installer Guide
    B1 and B2 directory numbers (DNs)
    Norstar has a B1 and B2 channel for transmitting voice and data. Each 
    telephone port on the ICS has a B1 DN and a B2 DN. Devices such as the 
    Business Series Terminals, and Norstar telephones use only the B1 DN. 
    Other devices may need both B1 and B2 channels, therefore, requiring B1 
    and B2 DNs.
    Norstar Compact ICS uses different numbering schemes for the B1 and B2 
    DNs, depending on how you upgrade your system and when an Expansion 
    Cartridge is added. See the tables below for details. 
    ICS numbering (restricted feature cartridge)
    ICS numbering (restricted feature cartridge, expanded)  
    Connector 
    #DevicePortsB1 DNB2 DN
    ICS (#1)Telephones 1-8
    I-ATA
    I-RAD101-108
    117
    11821-28
    29 (I-ATA)
    30 (I-RAD)31-38
    39
    40
    ICS (#2)Lines 001-004201-204— —— —
    Connector 
    #DevicePortsB1 DNB2 DN
    ICS (#1)Telephones 1-8
    I-ATA
    I-RAD
    Telephones 9-16101-108
    117
    118
    109-11621-28
    29 (I-ATA)
    30 (I-RAD)
    41-4831-38
    39
    40
    49-56
    ICS (#2)Analog:
    Lines 001-004
    Lines 031-034
    BRI:
    Lines 001-008
    Lines 031-038
    201-204
    231-234
    201-208
    225-232 
    (Profile 1, 3, 4)
    231-238 
    (Profile 2)— —
    — —
    — —
    — —— —
    — —
    — —
    — — 
    						
    							90 / Connecting the wiring
    Compact ICS 6.1 Installer GuideP0603539  02
    ICS numbering (restricted feature cartridge, expanded): 
    Expansion Cartridge added 
    ICS numbering (standard feature cartridge)  
    ICS numbering (standard feature cartridge): Expansion 
    Cartridge added at installation  
    ICS numbering (standard feature cartridge): Expansion 
    Cartridge added later  
    Connector 
    #DevicePortsB1 DNB2 DN
    ICS (#1)Telephones 1-8
    I-ATA
    I-RAD
    Telephones 9-16
    Telephones17-24101-108
    117
    118
    109-116
    119-12621-28
    29 (I-ATA)
    30 (I-RAD)
    41-48
    57-6431-38
    39
    40
    49-56
    65-72
    Connector 
    #DevicePortsB1 DNB2 DN
    ICS (#1)Telephones 1-16
    I-ATA
    I-RAD101-116
    117
    11821-36
    37 (I-ATA)
    38 (I-RAD)39-54
    55
    56
    Connector 
    #DevicePortsB1 DNB2 DN
    ICS (#1)Telephones 1-
    16
    I-ATA
    I-RAD
    Telephones 
    17-24101-116
    117
    118
    119-12621-36
    37 (I-ATA)
    38 (I-RAD)
    39-4647-62
    63
    64
    65-72
    Connector 
    #DevicePortsB1 DNB2 DN 
    						