    							Connecting the wiring / 91
    P0603539  02Compact ICS 6.1 Installer Guide
    ICS telephone and auxiliary ringer wiring chart 
    ICS (#1)Telephones 1-
    16
    I-ATA
    I-RAD
    Telephones 17-
    24101-116
    117
    118
    119-12621-36
    37 (I-ATA)
    38 (I-RAD)
    57-6439-54
    55
    56
    65-72
    Tip - B1 and B2 directory numbers reflect the 
    default numbering scheme.
    I-ATA and I-RAD are not physically connected 
    to the ICS #1 25-pair connector.
    The internal analog terminal adaptor (I-ATA) is 
    wired on the ICS #2 connector along with the 
    external lines and equipment for music and 
    paging. The internal remote access device 
    (I-RAD) appears on port 118 but has no wired 
    connection.
    PinWire colorPortServiceTelephones (ICS)
    26White-Blue101T1
    1Blue-White101R1
    27White-Orange102T2
    2Orange-White102R2
    28White-Green103T3
    3Green-White103R3
    29White-Brown104T4
    4Brown-White104R4
    30White-Slate105T5
    5Slate-White105R5
    31Red-Blue106T6
    6Blue-Red106R6 
    						
    							92 / Connecting the wiring
    Compact ICS 6.1 Installer GuideP0603539  02
    32Red-Orange107T7
    7Orange-Red107R7
    33Red-Green108T8
    8Green-Red108R8
    34Red-Brown109T9
    9Brown-Red109R9
    35Red-Slate110T10
    10Slate-Red110R10
    36Black-Blue111T11
    11Blue-Black111R11
    37Black-Orange112T12
    12Orange-Black112R12
    38Black-Green113T13
    13Green-Black113R13
    39Black-Brown114T14
    14Brown-Black114R14
    40Black-Slate115T15
    15Slate-Black115R15
    41Yellow-Blue116T16
    16Blue-Yellow116R16
    42Yellow-Orange119T17 
    17Orange-Yellow119R17 
    43Yellow-Green120T18
    18Green-Yellow120R18
    44Yellow-Brown121T19
    19Brown-Yellow121R19
    45Yellow-Slate122T20
    20Slate-Yellow122R20
    PinWire colorPortServiceTelephones (ICS) 
    						
    							Connecting the wiring / 93
    P0603539  02Compact ICS 6.1 Installer Guide
    T and R represent station connections and should not be confused with Tip and 
    Ring on external lines. Station connections are non-polarized.
    Stations 18 through 25 are available only when an Expansion Cartridge is in-
    stalled.
    For default DNs, see the ICS numbering charts starting on page 89.
    Note: Central Answering Positions (CAP) that require a station auxiliary power 
    supply (SAPS) must be connected with a four-wire cord, as the SAPS is connect-
    ed to the second wire pair. This includes any T7324 and CAP module combina-
    tion, and any T7316E telephone attached to more than 4 KIMs. Refer to the 
    SAPS installation card for detailed installation instructions.
    Wiring arrangement for Norstar ICS 
    46Violet-Blue123T21
    21Blue-Violet123R21
    47Violet-Orange124T22
    22Orange-Violet124R22
    48Violet-Green125T23
    23Green-Violet125R23
    49Violet-Brown126T24
    24Brown-Violet126R24
    50Violet-Slate----MakeAux. ringer
    25Slate-Violet----CommonAux. ringer
    PinWire colorPortServiceTelephones (ICS)
    ICS
    external line 
    connections, 
    auxiliary 
    services, 
    I-ATA and 
    emergency 
    telephone
    15.2 m 
    (50 ft.) 
    max. 
    length
    Distribution block
    two 25-pair connectorsauxiliary 
    servicesemergency telephone 
    I-ATARJ-21/CA-21external 
    lines 
    						
    							94 / Connecting the wiring
    Compact ICS 6.1 Installer GuideP0603539  02
    ICS external lines, I-ATA, music, and page wiring
    ICS external lines connector
    PinWire colorPortServiceEquipment
    26White-Blue201TLine 1
    1Blue-White201RLine 1
    27White-Orange202TLine 2
    2Orange-White202RLine 2
    28White-Green------------
    3Green-White------------
    29White-Brown------------
    4Brown-White------------
    30White-Slate203TLine 3
    5Slate-White203RLine 3
    31Red-Blue204TLine 4
    6Blue-Red204 RLine 4
    32Red-Orange------------
    7Orange-Red------------
    33Red-Green------------
    8Green-Red------------
    34Red-Brown231TLine 31
    9Brown-Red231RLine 31
    35Red-Slate232TLine 32
    10Slate-Red232RLine 32
    36Black-Blue------------
    11Blue-Black------------
    37Black-Orange------------
    12Orange-Black------------
    38Black-Green233TLine 33
    13Green-Black233RLine 33
    39Black-Brown234TLine 34
    14Brown-Black234RLine 34
    40Black-Slate------------
    15Slate-Black------------ 
    						
    							Connecting the wiring / 95
    P0603539  02Compact ICS 6.1 Installer Guide
    Lines 5 through 8 are not available to a system using a restricted feature car-
    tridge that has not been upgraded. For an explanation of port numbering, see 
    Port numbering on the wiring charts on page 88. The emergency telephone uses 
    line 002 (on Trunk Cartridge in slot 1). 
    41Yellow-Blue------------
    16Blue-Yellow------------
    42Yellow-Orange----Temergency telephone
    17Orange-Yellow----Remergency telephone
    43Yellow-Green------------
    18Green-Yellow------------
    44Yellow-Brown------------
    19Brown-Yellow------------
    45Yellow-Slate117TI-ATA
    20Slate-Yellow117RI-ATA
    46Violet-Blue------------
    21Blue-Violet------------
    47Violet-Orange------------
    22Orange-Violet------------
    48Violet-Green----GroundMusic
    23Green-Violet----MusicMusic
    49Violet-Brown----MakeExternal Page
    24Brown-Violet----CommonExternal Page
    50Violet-Slate----TPage
    25Slate-Violet----RPage
    Music source must be grounded.
    To avoid possible damage to your Compact ICS 
    system or music source, the music source 
    ground must be connected according to the 
    wiring charts. 
    ICS external lines connector
    PinWire colorPortServiceEquipment 
    						
    							96 / Connecting the wiring
    Compact ICS 6.1 Installer GuideP0603539  02
    BRI Wiring charts
    A BRI Card in Slot 1 uses loops 201 through 204. A BRI Card in Slot 2 
    uses loops 225 through 228 (profile 1, 3 or 4) or loops 231 through 234 
    (profile 2). Because a BRI-U2 Card has only two loops, it only uses the first 
    two loop numbers (201-202 and 225-226 (profile 1, 3, or 4) or  231-232 
    (profile 2)) when it occupies an ICS slot.
    The loops appearing on a BRI Card may be automatically assigned lines, 
    or assigned one or more ISDN DNs in 
    Hardware programming. If the loop 
    is configured as S or T or NT, lines are automatically assigned. If the loop 
    is configured as S or LT, you can assign one or more ISDN DNs to the loop. 
    The emergency telephone connection (pins 42 and 17 on ICS #2 connector) 
    cannot be used if a BRI Card is installed in Slot 1. All other pins which are 
    not shown in the BRI wiring charts are assigned as shown in the non-BRI 
    wiring charts beginning on page 91.
    Detailed information about configuring BRI Cards is included in the ISDN 
    chapter and in the Hardware section of the Programming chapter.
    ST Interface Cards wiring chart (profile 1, 3 or 4) 
    PinWire colorLoopServiceLines 
    (S or T loop) Terminal 
    equipment
    (S loop)
    26White-Blue201+TxLines 001-002Assigned DN
    1Blue-White201-TxLines 001-002Assigned DN
    27White-Orange201+RxLines 001-002Assigned DN
    2Orange-White201-RxLines 001-002Assigned DN
    28White-Green202+TxLines 003-004Assigned DN
    3Green-White202-TxLines 003-004Assigned DN
    29White-Brown202+RxLines 003-004Assigned DN
    4Brown-White202-RxLines 003-004Assigned DN
    30White-Slate203+TxLines 005-006Assigned DN
    5Slate-White203-TxLines 005-006Assigned DN
    31Red-Blue203+RxLines 005-006Assigned DN
    6Blue-Red203-RxLines 005-006Assigned DN 
    						
    							Connecting the wiring / 97
    P0603539  02Compact ICS 6.1 Installer Guide
    BRI ST wiring is polarity sensitive.
    Tx and Rx are Transmit and Receive for Norstar.
    32Red-Orange204+TxLines 007-008Assigned DN
    7Orange-Red204-TxLines 007-008Assigned DN
    33Red-Green204+RxLines 007-008Assigned DN
    8Green-Red204-RxLines 007-008Assigned DN
    34Red-Brown225+Tx Lines 031-032Assigned DN
    9Brown-Red225-Tx Lines 031-032Assigned DN
    35Red-Slate225+Rx Lines 031-032Assigned DN
    10Slate-Red225-Rx Lines 031-032Assigned DN
    36Black-Blue226+Tx Lines 033-034Assigned DN
    11Blue-Black226-Tx Lines 033-034Assigned DN
    37Black-Orange226+Rx Lines 033-034Assigned DN
    12Orange-Black226-Rx Lines 033-034Assigned DN
    38Black-Green227+TxLines 035-036Assigned DN
    13Green-Black227-TxLines 035-036Assigned DN
    39Black-Brown227+RxLines 035-036Assigned DN
    14Brown-Black227-RxLines 035-036Assigned DN
    40Black-Slate228+TxLines 037-038Assigned DN
    15Slate-Black228-TxLines 037-038Assigned DN
    41Yellow-Blue228+RxLines 037-038Assigned DN
    16Blue-Yellow228-RxLines 037-038Assigned DN
    PinWire colorLoopServiceLines 
    (S or T loop) Terminal 
    equipment
    (S loop) 
    						
    							98 / Connecting the wiring
    Compact ICS 6.1 Installer GuideP0603539  02
    ST Interface Cards wiring chart (profile 2) 
    PinWire colorLoopServiceLines 
    (S or T loop) Terminal 
    equipment
    (S loop)
    26White-Blue201+TxLines 001-002Assigned DN
    1Blue-White201-TxLines 001-002Assigned DN
    27White-Orange201+RxLines 001-002Assigned DN
    2Orange-White201-RxLines 001-002Assigned DN
    28White-Green202+TxLines 003-004Assigned DN
    3Green-White202-TxLines 003-004Assigned DN
    29White-Brown202+RxLines 003-004Assigned DN
    4Brown-White202-RxLines 003-004Assigned DN
    30White-Slate203+TxLines 005-006Assigned DN
    5Slate-White203-TxLines 005-006Assigned DN
    31Red-Blue203+RxLines 005-006Assigned DN
    6Blue-Red203-RxLines 005-006Assigned DN
    32Red-Orange204+TxLines 007-008Assigned DN
    7Orange-Red204-TxLines 007-008Assigned DN
    33Red-Green204+RxLines 007-008Assigned DN
    8Green-Red204-RxLines 007-008Assigned DN
    34Red-Brown231+TxLines 031-032Assigned DN
    9Brown-Red231-TxLines 031-032Assigned DN
    35Red-Slate231+RxLines 031-032Assigned DN
    10Slate-Red231-RxLines 031-032Assigned DN
    36Black-Blue232+TxLines 033-034Assigned DN
    11Blue-Black232-TxLines 033-034Assigned DN
    37Black-Orange232+RxLines 033-034Assigned DN
    12Orange-Black232-RxLines 033-034Assigned DN
    38Black-Green233+TxLines 035-036Assigned DN
    13Green-Black233-TxLines 035-036Assigned DN
    39Black-Brown233+RxLines 035-036Assigned DN
    14Brown-Black233-RxLines 035-036Assigned DN
    40Black-Slate234+TxLines 037-038Assigned DN
    15Slate-Black234-TxLines 037-038Assigned DN 
    						
    							Connecting the wiring / 99
    P0603539  02Compact ICS 6.1 Installer Guide
    BRI ST wiring is polarity sensitive.
    Tx and Rx are Transmit and Receive for Norstar.
    Wiring the BRI network interface
    A network interface provides the connection between the ISDN network 
    and the Compact ICS.
    If the card in the ICS is configured as a T loop, the ICS is wired to the 
    network connection using an NT1. For an S or T loop, the ICS and terminal 
    equipment share the loop wired to the NT1, which is in turn wired to the 
    network. See the ISDN chapter for more information about the NT1.
    Wiring for T or S network connection
    41Yellow-Blue234+RxLines 037-038Assigned DN
    16Blue-Yellow234-RxLines 037-038Assigned DN
    Pin (jack or 
    plug) NT1 connection (for 
    jack)ICS and optional TE connection 
    (plug)
    1not usedoptional power source 3 (+)
    2not usedoptional power source 3 (-)
    3+Rx+Tx
    4+Tx+Rx
    5-Tx-Rx
    6-Rx-Tx
    7not usedoptional power sink 2 (-)
    8not usedoptional power sink 2 (+)
    PinWire colorLoopServiceLines 
    (S or T loop) Terminal 
    equipment
    (S loop) 
    						
    							100 / Connecting the wiring
    Compact ICS 6.1 Installer GuideP0603539  02
    The Compact ICS supplies the NT1 functionality to a U-NT loop, allowing 
    a direct connection to the network. The connection may use a plug and 
    jack, or may be directly wired.
    Wiring for U-NT network interface  
    The BRI-U Card does not use or provide optional power.
    Some installations may not use a plug and jack for connections between the 
    ICS and the network.
    The following illustration shows the pin arrangement for a Bellcore 
    standard ISDN plug and jack. Other pin arrangements are possible.
    Pin numbering for network interface jack and plug
    PinNorstar 
    connectionNetwork interface connection (plug/
    jack)
    1not usedoptional battery status indicator (+)
    2not usedoptional battery status indicator (-)
    3not usedno connection
    4RR
    5TT
    6not usedno connection
    7not usedoptional power supply (-)
    8not usedoptional power supply (+)
    8  7  6  5  4  3  2  1