Connecting the wiring / 91 P0603539 02Compact ICS 6.1 Installer Guide ICS telephone and auxiliary ringer wiring chart ICS (#1)Telephones 1- 16 I-ATA I-RAD Telephones 17- 24101-116 117 118 119-12621-36 37 (I-ATA) 38 (I-RAD) 57-6439-54 55 56 65-72 Tip - B1 and B2 directory numbers reflect the default numbering scheme. I-ATA and I-RAD are not physically connected to the ICS #1 25-pair connector. The internal analog terminal adaptor (I-ATA) is wired on the ICS #2 connector along with the external lines and equipment for music and paging. The internal remote access device (I-RAD) appears on port 118 but has no wired connection. PinWire colorPortServiceTelephones (ICS) 26White-Blue101T1 1Blue-White101R1 27White-Orange102T2 2Orange-White102R2 28White-Green103T3 3Green-White103R3 29White-Brown104T4 4Brown-White104R4 30White-Slate105T5 5Slate-White105R5 31Red-Blue106T6 6Blue-Red106R6
![](/img/blank.gif)
92 / Connecting the wiring Compact ICS 6.1 Installer GuideP0603539 02 32Red-Orange107T7 7Orange-Red107R7 33Red-Green108T8 8Green-Red108R8 34Red-Brown109T9 9Brown-Red109R9 35Red-Slate110T10 10Slate-Red110R10 36Black-Blue111T11 11Blue-Black111R11 37Black-Orange112T12 12Orange-Black112R12 38Black-Green113T13 13Green-Black113R13 39Black-Brown114T14 14Brown-Black114R14 40Black-Slate115T15 15Slate-Black115R15 41Yellow-Blue116T16 16Blue-Yellow116R16 42Yellow-Orange119T17 17Orange-Yellow119R17 43Yellow-Green120T18 18Green-Yellow120R18 44Yellow-Brown121T19 19Brown-Yellow121R19 45Yellow-Slate122T20 20Slate-Yellow122R20 PinWire colorPortServiceTelephones (ICS)
![](/img/blank.gif)
Connecting the wiring / 93 P0603539 02Compact ICS 6.1 Installer Guide T and R represent station connections and should not be confused with Tip and Ring on external lines. Station connections are non-polarized. Stations 18 through 25 are available only when an Expansion Cartridge is in- stalled. For default DNs, see the ICS numbering charts starting on page 89. Note: Central Answering Positions (CAP) that require a station auxiliary power supply (SAPS) must be connected with a four-wire cord, as the SAPS is connect- ed to the second wire pair. This includes any T7324 and CAP module combina- tion, and any T7316E telephone attached to more than 4 KIMs. Refer to the SAPS installation card for detailed installation instructions. Wiring arrangement for Norstar ICS 46Violet-Blue123T21 21Blue-Violet123R21 47Violet-Orange124T22 22Orange-Violet124R22 48Violet-Green125T23 23Green-Violet125R23 49Violet-Brown126T24 24Brown-Violet126R24 50Violet-Slate----MakeAux. ringer 25Slate-Violet----CommonAux. ringer PinWire colorPortServiceTelephones (ICS) ICS external line connections, auxiliary services, I-ATA and emergency telephone 15.2 m (50 ft.) max. length Distribution block two 25-pair connectorsauxiliary servicesemergency telephone I-ATARJ-21/CA-21external lines
![](/img/blank.gif)
94 / Connecting the wiring Compact ICS 6.1 Installer GuideP0603539 02 ICS external lines, I-ATA, music, and page wiring ICS external lines connector PinWire colorPortServiceEquipment 26White-Blue201TLine 1 1Blue-White201RLine 1 27White-Orange202TLine 2 2Orange-White202RLine 2 28White-Green------------ 3Green-White------------ 29White-Brown------------ 4Brown-White------------ 30White-Slate203TLine 3 5Slate-White203RLine 3 31Red-Blue204TLine 4 6Blue-Red204 RLine 4 32Red-Orange------------ 7Orange-Red------------ 33Red-Green------------ 8Green-Red------------ 34Red-Brown231TLine 31 9Brown-Red231RLine 31 35Red-Slate232TLine 32 10Slate-Red232RLine 32 36Black-Blue------------ 11Blue-Black------------ 37Black-Orange------------ 12Orange-Black------------ 38Black-Green233TLine 33 13Green-Black233RLine 33 39Black-Brown234TLine 34 14Brown-Black234RLine 34 40Black-Slate------------ 15Slate-Black------------
![](/img/blank.gif)
Connecting the wiring / 95 P0603539 02Compact ICS 6.1 Installer Guide Lines 5 through 8 are not available to a system using a restricted feature car- tridge that has not been upgraded. For an explanation of port numbering, see Port numbering on the wiring charts on page 88. The emergency telephone uses line 002 (on Trunk Cartridge in slot 1). 41Yellow-Blue------------ 16Blue-Yellow------------ 42Yellow-Orange----Temergency telephone 17Orange-Yellow----Remergency telephone 43Yellow-Green------------ 18Green-Yellow------------ 44Yellow-Brown------------ 19Brown-Yellow------------ 45Yellow-Slate117TI-ATA 20Slate-Yellow117RI-ATA 46Violet-Blue------------ 21Blue-Violet------------ 47Violet-Orange------------ 22Orange-Violet------------ 48Violet-Green----GroundMusic 23Green-Violet----MusicMusic 49Violet-Brown----MakeExternal Page 24Brown-Violet----CommonExternal Page 50Violet-Slate----TPage 25Slate-Violet----RPage Music source must be grounded. To avoid possible damage to your Compact ICS system or music source, the music source ground must be connected according to the wiring charts. ICS external lines connector PinWire colorPortServiceEquipment
![](/img/blank.gif)
96 / Connecting the wiring Compact ICS 6.1 Installer GuideP0603539 02 BRI Wiring charts A BRI Card in Slot 1 uses loops 201 through 204. A BRI Card in Slot 2 uses loops 225 through 228 (profile 1, 3 or 4) or loops 231 through 234 (profile 2). Because a BRI-U2 Card has only two loops, it only uses the first two loop numbers (201-202 and 225-226 (profile 1, 3, or 4) or 231-232 (profile 2)) when it occupies an ICS slot. The loops appearing on a BRI Card may be automatically assigned lines, or assigned one or more ISDN DNs in Hardware programming. If the loop is configured as S or T or NT, lines are automatically assigned. If the loop is configured as S or LT, you can assign one or more ISDN DNs to the loop. The emergency telephone connection (pins 42 and 17 on ICS #2 connector) cannot be used if a BRI Card is installed in Slot 1. All other pins which are not shown in the BRI wiring charts are assigned as shown in the non-BRI wiring charts beginning on page 91. Detailed information about configuring BRI Cards is included in the ISDN chapter and in the Hardware section of the Programming chapter. ST Interface Cards wiring chart (profile 1, 3 or 4) PinWire colorLoopServiceLines (S or T loop) Terminal equipment (S loop) 26White-Blue201+TxLines 001-002Assigned DN 1Blue-White201-TxLines 001-002Assigned DN 27White-Orange201+RxLines 001-002Assigned DN 2Orange-White201-RxLines 001-002Assigned DN 28White-Green202+TxLines 003-004Assigned DN 3Green-White202-TxLines 003-004Assigned DN 29White-Brown202+RxLines 003-004Assigned DN 4Brown-White202-RxLines 003-004Assigned DN 30White-Slate203+TxLines 005-006Assigned DN 5Slate-White203-TxLines 005-006Assigned DN 31Red-Blue203+RxLines 005-006Assigned DN 6Blue-Red203-RxLines 005-006Assigned DN
![](/img/blank.gif)
Connecting the wiring / 97 P0603539 02Compact ICS 6.1 Installer Guide BRI ST wiring is polarity sensitive. Tx and Rx are Transmit and Receive for Norstar. 32Red-Orange204+TxLines 007-008Assigned DN 7Orange-Red204-TxLines 007-008Assigned DN 33Red-Green204+RxLines 007-008Assigned DN 8Green-Red204-RxLines 007-008Assigned DN 34Red-Brown225+Tx Lines 031-032Assigned DN 9Brown-Red225-Tx Lines 031-032Assigned DN 35Red-Slate225+Rx Lines 031-032Assigned DN 10Slate-Red225-Rx Lines 031-032Assigned DN 36Black-Blue226+Tx Lines 033-034Assigned DN 11Blue-Black226-Tx Lines 033-034Assigned DN 37Black-Orange226+Rx Lines 033-034Assigned DN 12Orange-Black226-Rx Lines 033-034Assigned DN 38Black-Green227+TxLines 035-036Assigned DN 13Green-Black227-TxLines 035-036Assigned DN 39Black-Brown227+RxLines 035-036Assigned DN 14Brown-Black227-RxLines 035-036Assigned DN 40Black-Slate228+TxLines 037-038Assigned DN 15Slate-Black228-TxLines 037-038Assigned DN 41Yellow-Blue228+RxLines 037-038Assigned DN 16Blue-Yellow228-RxLines 037-038Assigned DN PinWire colorLoopServiceLines (S or T loop) Terminal equipment (S loop)
![](/img/blank.gif)
98 / Connecting the wiring Compact ICS 6.1 Installer GuideP0603539 02 ST Interface Cards wiring chart (profile 2) PinWire colorLoopServiceLines (S or T loop) Terminal equipment (S loop) 26White-Blue201+TxLines 001-002Assigned DN 1Blue-White201-TxLines 001-002Assigned DN 27White-Orange201+RxLines 001-002Assigned DN 2Orange-White201-RxLines 001-002Assigned DN 28White-Green202+TxLines 003-004Assigned DN 3Green-White202-TxLines 003-004Assigned DN 29White-Brown202+RxLines 003-004Assigned DN 4Brown-White202-RxLines 003-004Assigned DN 30White-Slate203+TxLines 005-006Assigned DN 5Slate-White203-TxLines 005-006Assigned DN 31Red-Blue203+RxLines 005-006Assigned DN 6Blue-Red203-RxLines 005-006Assigned DN 32Red-Orange204+TxLines 007-008Assigned DN 7Orange-Red204-TxLines 007-008Assigned DN 33Red-Green204+RxLines 007-008Assigned DN 8Green-Red204-RxLines 007-008Assigned DN 34Red-Brown231+TxLines 031-032Assigned DN 9Brown-Red231-TxLines 031-032Assigned DN 35Red-Slate231+RxLines 031-032Assigned DN 10Slate-Red231-RxLines 031-032Assigned DN 36Black-Blue232+TxLines 033-034Assigned DN 11Blue-Black232-TxLines 033-034Assigned DN 37Black-Orange232+RxLines 033-034Assigned DN 12Orange-Black232-RxLines 033-034Assigned DN 38Black-Green233+TxLines 035-036Assigned DN 13Green-Black233-TxLines 035-036Assigned DN 39Black-Brown233+RxLines 035-036Assigned DN 14Brown-Black233-RxLines 035-036Assigned DN 40Black-Slate234+TxLines 037-038Assigned DN 15Slate-Black234-TxLines 037-038Assigned DN
![](/img/blank.gif)
Connecting the wiring / 99 P0603539 02Compact ICS 6.1 Installer Guide BRI ST wiring is polarity sensitive. Tx and Rx are Transmit and Receive for Norstar. Wiring the BRI network interface A network interface provides the connection between the ISDN network and the Compact ICS. If the card in the ICS is configured as a T loop, the ICS is wired to the network connection using an NT1. For an S or T loop, the ICS and terminal equipment share the loop wired to the NT1, which is in turn wired to the network. See the ISDN chapter for more information about the NT1. Wiring for T or S network connection 41Yellow-Blue234+RxLines 037-038Assigned DN 16Blue-Yellow234-RxLines 037-038Assigned DN Pin (jack or plug) NT1 connection (for jack)ICS and optional TE connection (plug) 1not usedoptional power source 3 (+) 2not usedoptional power source 3 (-) 3+Rx+Tx 4+Tx+Rx 5-Tx-Rx 6-Rx-Tx 7not usedoptional power sink 2 (-) 8not usedoptional power sink 2 (+) PinWire colorLoopServiceLines (S or T loop) Terminal equipment (S loop)
![](/img/blank.gif)
100 / Connecting the wiring Compact ICS 6.1 Installer GuideP0603539 02 The Compact ICS supplies the NT1 functionality to a U-NT loop, allowing a direct connection to the network. The connection may use a plug and jack, or may be directly wired. Wiring for U-NT network interface The BRI-U Card does not use or provide optional power. Some installations may not use a plug and jack for connections between the ICS and the network. The following illustration shows the pin arrangement for a Bellcore standard ISDN plug and jack. Other pin arrangements are possible. Pin numbering for network interface jack and plug PinNorstar connectionNetwork interface connection (plug/ jack) 1not usedoptional battery status indicator (+) 2not usedoptional battery status indicator (-) 3not usedno connection 4RR 5TT 6not usedno connection 7not usedoptional power supply (-) 8not usedoptional power supply (+) 8 7 6 5 4 3 2 1 1 2 3 4 5 6 7 8