    							Installing the cartridges / 81
    P0992669 03Compact ICS 6.0 Installer Guide
    Installing the Expansion Cartridge   
    The Expansion Cartridge must be equipped with clock control if you are 
    installing BRI Cards.
    1. Remove the filler faceplate from slot 3 (and slot 2 if there is no Trunk 
    Cartridge), using a screwdriver to pry the bottom edge(s) out.
    2. If required, snap the two parts of the faceplate apart and put back the 
    filler faceplate in slot 2.
    3. Slide the Expansion Cartridge into slot 3, applying equal pressure at 
    the top and bottom. See illustration on page 82.
    4. Close the cartridge clips at the same time, to keep the cartridge aligned 
    with the connector.
     
      
    Removing the expansion cartridge will cause a 
    cold restart.
    If you downsize the system by removing the 
    expansion cartridge, all system programming will be 
    lost.
    Expansion CartridgeExpansion Cartridge
    with ClockingClocking Cartridge 
    						
    							82 / Installing the cartridges
    Compact ICS 6.0 Installer GuideP0992669 03
     
    Installing the Expansion Cartridge
    Alarm Telephone will indicate a cold reset.
    An alarm and a prompt indicating warm or cold reset 
    will occur on the alarm telephone when the system 
    size has been decreased.  
    						
    							Connecting the wiring / 83
    P0992669 03Compact ICS 6.0 Installer Guide
    Connecting the wiring
    Connecting the wiring for a Compact ICS
    Extend 150 mm (6 in.) 
    and clamp before bringing
    cables together.
    Do not attach central office
    or station line connections until
    power is connected to the ICS. 
    						
    							84 / Connecting the wiring
    Compact ICS 6.0 Installer GuideP0992669 03
    Connecting the wiring to the distribution panel
    1. Route the cables from the ICS to the distribution panel.
    2. Bundle the cables with cable ties and secure them to the wall to support 
    their weight.
    3. Connect the telephone and auxiliary equipment wires to the 
    appropriate pins on the distribution block (refer to the wiring charts).
    4. Cross-connect the ICS telephone and auxiliary equipment wiring to 
    the corresponding station pins on the distribution block.
    5. Using a single pair of wires for each telephone, connect each of the 
    telephones according to the wiring charts.
    6. Cross-connect the external lines to the distribution block (refer to the 
    wiring charts).
    Wiring charts
    Port numbering on the wiring charts
    The port number listed on the wiring charts is useful in tracking down 
    faults during a Maintenance session where error codes appear on a Norstar 
    telephone display. Refer to Maintenance on page 291 for more 
    information.
    For example, the code 112 appearing as part of an error message indicates 
    that the problem is with the telephone connected to the system at port 112. 
    The corresponding pins on the distribution block are pin 37 (black-orange) 
    and pin 12 (orange-black).
    Integrated Communications System (ICS)
    In the charts on the following pages, notice that the ICS has two 25-pair 
    connectors. One handles telephones and auxiliary ringer. The other handles 
    lines, I-ATA, music, and page. 
    						
    							Connecting the wiring / 85
    P0992669 03Compact ICS 6.0 Installer Guide
    B1 and B2 directory numbers (DNs)
    Norstar has a B1 and B2 channel for transmitting voice and data. Each 
    telephone port on the ICS has a B1 DN and a B2 DN. Devices such as the 
    Business Series Terminals, and Norstar telephones use only the B1 DN. 
    Other devices may need both B1 and B2 channels, therefore requiring B1 
    and B2 DNs.
    Norstar Compact ICS uses different numbering schemes for the B1 and B2 
    DNs, depending on how you upgrade your system and when an Expansion 
    Cartridge is added. See the tables below for details. 
    ICS numbering (restricted feature cartridge)
    ICS numbering (restricted feature cartridge, expanded)  
    Connector #DevicePortsB1 DNB2 DN
    ICS (#1)Telephones 1-8
    I-ATA
    I-RAD101-108
    117
    11821-28
    29 (I-ATA)
    30 (I-RAD)31-38
    39
    40
    ICS (#2)Lines 001-004201-204— —— —
    Connector 
    #DevicePortsB1 DNB2 DN
    ICS (#1)Telephones 1-8
    I-ATA
    I-RAD
    Telephones 9-16101-108
    117
    118
    109-11621-28
    29 (I-ATA)
    30 (I-RAD)
    41-4831-38
    39
    40
    49-56
    ICS (#2)Analog:
    Lines 001-004
    Lines 031-034
    BRI:
    Lines 001-008
    Lines 031-038
    201-204
    231-234
    201-208
    231-238— —
    — —
    — —
    — —— —
    — —
    — —
    — — 
    						
    							86 / Connecting the wiring
    Compact ICS 6.0 Installer GuideP0992669 03
    ICS numbering (restricted feature cartridge, expanded): 
    Expansion Cartridge added 
    ICS numbering (standard feature cartridge)  
    ICS numbering (standard feature cartridge): Expansion 
    Cartridge added at installation  
    Connector 
    #DevicePortsB1 DNB2 DN
    ICS (#1)Telephones 1-8
    I-ATA
    I-RAD
    Telephones 9-16
    Telephones17-24101-108
    117
    118
    109-116
    119-12621-28
    29 (I-ATA)
    30 (I-RAD)
    41-48
    57-6431-38
    39
    40
    49-56
    65-72
    ICS (#2)Analog:
    Lines 001-004
    Lines 031-034
    BRI:
    Lines 001-008
    Lines 031-038
    201-204
    231-234
    201-208
    231-238— —
    — —
    — —
    — —— —
    — —
    — —
    — —
    Connector #DevicePortsB1 DNB2 DN
    ICS (#1)Telephones 1-
    16
    I-ATA
    I-RAD101-116
    117
    11821-36
    37 (I-ATA)
    38 (I-RAD)39-54
    55
    56
    ICS (#2)Analog:
    Lines 001-004
    Lines 031-034
    BRI:
    Lines 001-008
    Lines 031-038
    201-204
    231-234
    201-208
    231-238— —
    — —
    — —
    — —— —
    — —
    — —
    — —
    Connector 
    #DevicePortsB1 DNB2 DN
    ICS (#1)Telephones 1-16
    I-ATA
    I-RAD
    Telephones 17-24101-116
    117
    118
    119-12621-36
    37 (I-ATA)
    38 (I-RAD)
    39-4647-62
    63
    64
    65-72 
    						
    							Connecting the wiring / 87
    P0992669 03Compact ICS 6.0 Installer Guide
    ICS numbering (standard feature cartridge): Expansion 
    Cartridge added later  
    ICS (#2)Analog:
    Lines 001-004
    Lines 031-034
    BRI:
    Lines 001-008
    Lines 031-038
    201-204
    231-234
    201-208
    231-238— —
    — —
    — —
    — —— —
    — —
    — —
    — —
    Connector #DevicePortsB1 DNB2 DN
    ICS (#1)Telephones 1-16
    I-ATA
    I-RAD
    Telephones 17-24101-116
    117
    118
    119-12621-36
    37 (I-ATA)
    38 (I-RAD)
    57-6439-54
    55
    56
    65-72
    ICS (#2)Analog:
    Lines 001-004
    Lines 031-034
    BRI:
    Lines 001-008
    Lines 031-038
    201-204
    231-234
    201-208
    231-238— —
    — —
    — —
    — —— —
    — —
    — —
    — —
    Tip - B1 and B2 directory numbers reflect the 
    default numbering scheme.
    I-ATA and I-RAD are not physically connected 
    to the ICS #1 25-pair connector.
    The internal analog terminal adaptor (I-ATA) is 
    wired on the ICS #2 connector along with the 
    external lines and equipment for music and 
    paging. The internal remote access device 
    (I-RAD) appears on port 118 but has no wired 
    connection. 
    						
    							88 / Connecting the wiring
    Compact ICS 6.0 Installer GuideP0992669 03
    ICS telephone and auxiliary ringer wiring chart 
    PinWire colorPortServiceTelephones (ICS)
    26White-Blue101T1
    1Blue-White101R1
    27White-Orange102T2
    2Orange-White102R2
    28White-Green103T3
    3Green-White103R3
    29White-Brown104T4
    4Brown-White104R4
    30White-Slate105T5
    5Slate-White105R5
    31Red-Blue106T6
    6Blue-Red106R6
    32Red-Orange107T7
    7Orange-Red107R7
    33Red-Green108T8
    8Green-Red108R8
    34Red-Brown109T9
    9Brown-Red109R9
    35Red-Slate110T10
    10Slate-Red110R10
    36Black-Blue111T11
    11Blue-Black111R11
    37Black-Orange112T12
    12Orange-Black112R12
    38Black-Green113T13
    13Green-Black113R13
    39Black-Brown114T14
    14Brown-Black114R14
    40Black-Slate115T15
    15Slate-Black115R15
    41Yellow-Blue116T16 
    						
    							Connecting the wiring / 89
    P0992669 03Compact ICS 6.0 Installer Guide
    T and R represent station connections and should not be confused with Tip and 
    Ring on external lines. Station connections are non-polarized.
    Stations 18 through 25 are available only when an Expansion Cartridge is in-
    stalled.
    For default DNs, see the ICS numbering charts starting on page 85.
    16Blue-Yellow116R16
    no physical connection at port 117 (reserved for I-ATA)
    no physical connection at port 118 (reserved for I-RAD)
    42Yellow-Orange119T17 
    17Orange-Yellow119R17 
    43Yellow-Green120T18
    18Green-Yellow120R18
    44Yellow-Brown121T19
    19Brown-Yellow121R19
    45Yellow-Slate122T20
    20Slate-Yellow122R20
    46Violet-Blue123T21
    21Blue-Violet123R21
    47Violet-Orange124T22
    22Orange-Violet124R22
    48Violet-Green125T23
    23Green-Violet125R23
    49Violet-Brown126T24
    24Brown-Violet126R24
    50Violet-Slate----MakeAux. ringer
    25Slate-Violet----CommonAux. ringer
    PinWire colorPortServiceTelephones (ICS) 
    						
    							90 / Connecting the wiring
    Compact ICS 6.0 Installer GuideP0992669 03
    Wiring arrangement for Norstar ICS 
    ICS external lines, I-ATA, music, and page wiring
    ICS external lines connector
    PinWire colorPortServiceEquipment
    26White-Blue201TLine 1
    1Blue-White201RLine 1
    27White-Orange202TLine 2
    2Orange-White202RLine 2
    28White-Green------------
    3Green-White------------
    29White-Brown------------
    4Brown-White------------
    30White-Slate203TLine 3
    5Slate-White203RLine 3
    31Red-Blue204TLine 4
    6Blue-Red204 RLine 4
    32Red-Orange------------
    7Orange-Red------------
    33Red-Green------------
    8Green-Red------------
    34Red-Brown231TLine 31
    9Brown-Red231RLine 31
    ICS
    external line 
    connections, 
    auxiliary 
    services, 
    I-ATA and 
    emergency 
    telephone
    15.2 m 
    (50 ft.) 
    max. 
    length
    Distribution block
    two 25-pair connectorsauxiliary 
    servicesemergency telephone 
    I-ATARJ-21/CA-21external 
    lines 
    						