    							Problems with telephones / 261
    P0992669 03Compact ICS 6.0 Installer Guide
    Norstar telephone dead
    1. Run a Station Set Test (²¡âÞ). Instructions are included in 
    the Compact ICS 6.0 System Coordinator Guide.
    2. If more than one telephone is affected, refer to the ICS down section 
    on page 278.
    3. Check for dial tone.
    4. Check the display.
    5. If the problem persists, replace the telephone with a known working 
    Norstar telephone of the same type, so that the programming is 
    retained.
    6. Check the internal wiring at both the modular jack and the distribution 
    cross-connect. A Norstar telephone port should have between 15 and 
    26 V DC across the Tip and Ring when the telephone is disconnected.
    7. Check the line cord.
    Running a Maintenance session to test a dead telephone
    1. Run a Maintenance session to ensure that the telephone is not disabled. 
    See Port/DN status on page 294.
    2. Disable the port that the telephone is connected to using the heading
     
    Port/DN status.
    3. Enable the port that the telephone is connected to using the heading
     
    Port/DN status.
    Replacing a telephone
    In a powered-up system, an existing Norstar telephone can be replaced by 
    a new Norstar telephone. If you use a Norstar telephone that has already 
    been used on the system, it may have to be reprogrammed.
    Replacing Norstar telephones of the same type
    If an existing Norstar telephone is unplugged, and a new Norstar telephone 
    of the same type is then plugged into the same jack (for example, replacing 
    an T7208 telephone with another T7208 telephone), the new telephone 
    acquires the programming and the internal number of the old telephone. 
    This is normally done to replace a defective telephone. 
    						
    							262 / Problems with telephones
    Compact ICS 6.0 Installer GuideP0992669 03
    Replacing Norstar telephones of different types
    If an existing Norstar telephone is unplugged, and a new Norstar telephone 
    of a different type is plugged into the same jack (for example, replacing an 
    T7208 telephone with an T7316 telephone), the new telephone keeps the 
    old internal number. The new telephone receives default programming for 
    a telephone of its type. 
    If the telephone being replaced has more lines than the new telephone, 
    automatic outgoing line selection may not work with the Handsfree/Mute 
    feature. A line must be selected manually.
    Status of a telephone that was replaced
    The old Norstar telephone that was unplugged and replaced by a new 
    Norstar telephone loses its programming and internal number. The old 
    telephone internal number has been given to the new telephone and the 
    programming has either been removed or given to the new telephone when 
    it was plugged into the old jack. The replaced telephone (if still functional) 
    is now treated by the system as a telephone not previously in service.
    Emergency telephone dead
    1. Verify that the power indicator on the ICS is not lit.
    2. Verify that there is no dial tone at the emergency telephone.
    3. Check that  the external line and  emergency  telephone connections 
    have been made correctly.
    4. Ensure that the emergency telephone is not faulty by connecting it 
    directly to the external line 002 and listening for dial tone.
    5. Verify that the ICS has a Loop Start Trunk Cartridge installed. 
    6. Verify that there is dial tone on line 002 of the ICS.
    7. Replace the ICS. 
    						
    							Problems with lines / 263
    P0992669 03Compact ICS 6.0 Installer Guide
    Problems with lines
    The troubleshooting problems listed here focus on trouble with making 
    calls or using lines. For problems which are specific to BRI lines, see 
    Problems with BRI service on page 274.
    Calls cannot be made (but can be received)
    1. Press ²¥â.
    2. Press a line button.
    3. If an incorrect line number or name appears (or if neither appears) on 
    the Norstar telephone display, check the programming settings.
    OR
    If the correct line number or name appears on the Norstar telephone 
    display, make sure the external lines are properly cross-connected.
    4. Check the restrictions that are applied to the set and to the lines at the 
    set.
    5. Check that the dialing mode is consistent with that used by the central 
    office (CO).
    6. Run a Maintenance session and verify that the module in which the 
    Trunk Cartridge is installed in is not disabled or unequipped using the 
    heading Module status.
    7. Run a Maintenance session and disable the appropriate ports using the 
    heading Port/DN status. For charts showing external line port number 
    defaults, refer to Installing the hardware.
    8. Enable the appropriate ports using the heading Port/DN status.
    9. To check the line, contact the telephone company. 
    						
    							264 / Problems with lines
    Compact ICS 6.0 Installer GuideP0992669 03
    Dial tone absent on external lines
    1. Use Button Inquiry (²¥â) to display the number of the external 
    line you are testing.
    2. Check for dial tone using a test telephone at the connections for the 
    external line on the distribution block.
    3. Make sure that a Trunk Cartridge for the line is properly installed in 
    the ICS.
    4. Refer to the section on Trunk Cartridge trouble in this chapter.
    5. Run a Maintenance session to ensure that the line is not disabled. (See 
    Port/DN Status in the Maintenance chapter.)
    Hung lines at a telephone
    Line indicators that have been solid for a long time are the only visible 
    indication that lines are hung. 
    Possible problem
    A line that has been redirected using Line Redirection may, under some 
    circumstances, remain busy after a call is over. If this happens, the 
    outgoing line for the redirection also remains busy. You can clear this kind 
    of hung line only at the telephone that was used to redirect the line. 
    Solution
    1. Enter the Button Inquiry feature code (²¥â) at the telephone 
    that was used to redirect the line. 
    2. Press the button of the redirected line.
    3. Press 
    SHOW or £.
    4. Press 
    DROP or •. 
    Both the redirected line and the outgoing line for the redirection should 
    now be cleared. 
    						
    							Problems with lines / 265
    P0992669 03Compact ICS 6.0 Installer Guide
    Possible problem
    The supervision or Discon timer programming for the line does not match 
    the settings for the line at the central office.
    Solution
    Verify that your programming for the line matches the central office 
    settings.
    Possible problem
    Lines are still hung after all the above solutions have been investigated or 
    tried out.
    Solution
    For lines that are hung for any other reason, you will have to run a 
    Maintenance session. 
    1. Run a Maintenance session and go to the heading
     Module status.
    2. Disable and enable the affected Trunk Cartridge. 
    Follow the procedures in the Troubleshooting overview and the Installation 
    check sections before proceeding.
    Auto-answer line rings at a Norstar telephone
    Possible problem
    You configured a loop start trunk as auto-answer but the installed hardware 
    does not support disconnect supervision. (In this case, the symptom would 
    be accompanied by the Alarm 62 code symptom.)
    Solution
    Reconfigure the trunk as manual answer.
    OR
    Replace the Trunk Cartridge with one that provides disconnect 
    supervision. 
    						
    							266 / Problems with lines
    Compact ICS 6.0 Installer GuideP0992669 03
    Possible problem
    The line is configured as auto-answer and unsupervised.
    Solution
    Reconfigure the line as manual answer.
    OR
    Reconfigure the line as supervised.
    Possible problem
    The line is not equipped for disconnect supervision at the central office.
    Solution
    Reconfigure the trunk as manual answer.
    Possible problem
    The Discon timer setting for the Trunk Cartridge in
    Trunk/Line data does not match the setting for the line at the central office.
    Solution
    Reconfigure the Discon timer to match the setting at the central office.
    Prime telephone gets misdialed calls
    Possible problem
    The digits sent by a switch at a central office or in the private network did 
    not match any Received number, the Auto DN, or the DISA DN. The call 
    has been routed to the prime telephone for the incoming trunk.
    Solution
    1. Verify that the switch is sending the correct number of digits for the 
    Received number length defined in your system.
    2. Verify all the digit strings that the switch should be sending. 
    						
    							Problems with lines / 267
    P0992669 03Compact ICS 6.0 Installer Guide
    3. Check that you have defined the corresponding Received number for 
    every target line in your system.
    4. Make sure that the published telephone numbers for your network are 
    correct.
    Selected line shows ‘Not in service’ or ‘Not available’ 
    Possible problem
    The line has been disabled for maintenance purposes.
    Solution
    Enable the line.
    OR
    If the line will be out of service for some time, configure another line to 
    replace it on the telephone.
    Selected line pool shows ‘No free lines’ 
    Possible problem
    If this happens often, there are not enough lines in the line pool to serve the 
    number of line pool users.
    Solution
    Enter programming and move less-used loop start trunks from other line 
    pools into the deficient line pool. 
    						
    							268 / Problems with the I-ATA
    Compact ICS 6.0 Installer GuideP0992669 03
    Problems with the I-ATA
    The problems listed here focus on trouble with the I-ATA and the analog 
    device connected to it.
    Calls do not ring and caller does not receive busy tone
    1. Verify that the ringer of the attached analog device is turned on.
    2. Check the ringer volume.
    3. Verify that calls can be answered even when the device does not ring.
    4. Replace the analog device with a single-line analog telephone and 
    check for ringing.
    5. Check for ringing at the wiring connection block using a single-line 
    analog telephone.
    6. Check wiring from the connection block to the attached analog device.
    7. Check the requirements of the analog device to see if it is compatible 
    with the I-ATA specifications (see specifications on page 329).
    I-ATA is always busy
    1. Remove the attached analog device from the I-ATA line and make a 
    call to the I-ATA from a Norstar telephone. If the line is not busy, the 
    analog device may be faulty. If the line is busy, check the wiring.
    2. Ensure that the analog device is not faulty by connecting it directly to 
    an external line and verifying that it functions correctly.
    3. Check the internal wiring at the modular jack and the distribution 
    cross-connect. The I-ATA port should have about 31 Vdc across the 
    Tip and Ring when the telephone is disconnected.
    4. Check the requirements of the analog device to see if it is compatible 
    with the I-ATA specifications. Refer to Specifications on page 329.
    5. Run a maintenance session to ensure the I-ATA is not disabled. Refer 
    to Port/DN status on page 294. 
    						
    							Problems with the I-ATA / 269
    P0992669 03Compact ICS 6.0 Installer Guide
    Calls cannot be answered (or dial tone is not present 
    when making calls)
    1. Check that the I-ATA connections have been made correctly.
    2. Replace the analog device with a single-line analog telephone and 
    check for dial tone.
    3. Ensure that the analog device is not faulty by connecting it directly to 
    an external line and checking for dial tone.
    4. Check that the I-ATA is not busy by making a call to it from a Norstar 
    telephone. If it is busy, remove the analog device and check for busy.
    5. Check the internal wiring at the modular jack and the distribution 
    cross-connect. The I-ATA port should have about 31 Vdc across the 
    Tip and Ring when the telephone is disconnected. The voltage should 
    drop when the analog telephone is connected and a call  is attempted.
    6. Check the requirements of the analog device to see if it is compatible 
    with the I-ATA specifications. Refer to Specifications on page 329.
    Calls cannot be made (but dial tone is present)
    1. Ensure that the analog device is not faulty by connecting it directly to 
    an external line and making a call.
    2. Ensure the dialed number is not restricted by call restrictions.
    3. Check if the ICS is detecting dialing by listening to the dial tone. Dial 
    the first digit of an internal telephone DN and check that dial tone is 
    removed. If you still hear dial tone, the ICS is not detecting the dialed 
    digit.
    4. Determine if the problem is associated with the wiring by connecting 
    the analog device directly at the modular jack or the distribution cross-
    connect by the ICS. If calls can be made with this connection, the 
    problem may be with the internal wiring.
    5. Check the internal wiring at the modular jack and the distribution 
    cross-connect. The I-ATA port should have about 31 Vdc across the 
    Tip and Ring when the telephone is disconnected. The voltage should 
    drop when the analog telephone is connected and a call  is attempted.
    6. Check the requirements of the analog device to see if it is compatible 
    with the I-ATA specifications. Refer to Specifications on page 329. 
    						
    							270 / Problems with optional equipment
    Compact ICS 6.0 Installer GuideP0992669 03
    Problems with optional equipment
    Auxiliary ringer
    1. If the auxiliary ringer is used for Schedules (Night, Evening, or Lunch 
    schedule), ensure that Schedules is activated from the control 
    telephone.
    2. Check the wiring between the auxiliary ringer generator and the 
    ringing device. Refer to the auxiliary ringer wiring chart.
    3. Check the wiring between the auxiliary ringer generator and the 
    distribution block.
    Auxiliary ringer wiring
    4. Ensure that the auxiliary ringer contacts are operating properly by 
    checking with an ohmmeter across the auxiliary ringer pin contacts. 
    Refer to the auxiliary ringer wiring chart.
    5. Check that the auxiliary ringer pin contacts are programmed to operate 
    in conjunction with any or all of the features in the auxiliary ringer 
    programming chart.
    Auxiliary ringer programming
    The maximum current carrying capability of the Norstar auxiliary relay 
    contacts is 50 mA dc. They are designed to operate with the auxiliary ringer 
    generator, or equivalent.
    FeaturePin
    Auxiliary ring (Make)50 (Violet-Slate)
    Auxiliary ring (Common)25 (Slate-Violet)
    FeatureProgrammed in
    Auxiliary ringer: LinesLinesTrunk/Line data
    Auxiliary ringer: SetsTerminals&SetsCapabilities
    Service ModesServicesRinging service 
    						