    Have a look at the manual Lucent Technologies Intuity CONVERSANT System Version 7.0 Guide online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 413 Lucent Technologies manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.

    Page
    of 1206
    							5  
    Switch Interface Administration  Digital Interfaces
    Intuity™ CONVERSANT® System Version 7.0 Administration 
    585-313-501 Issue 3 January 2000 297
    Change E1 CAS P2 - Australian Network ParametersThe E1 circuit card must first be assigned to the E1 CAS P2 - Australian 
    Network protocol to use this procedure. See Assign E1 CAS P2 - Australian Network Protocol to E1 Circuit Cards
     on page 294
    , for more information 
    about making the initial assignment.
    Note:Before attempting to make any assignment changes to circuit 
    cards, they must be in the “manoos” state. See Equipment State
     
    on page 150
     in Chapter 3, 
    Voice System Administration
     , for 
    additional information.
    If you change digital protocol assignments on the voice system, 
    you must make the change on the switch as well.
    Use the following procedure to change the E1 CAS P2 - Australian Network 
    parameters:
    1  
    Start at the E1 CAS P2 - Australian Network menu (Figure 146 on page 293
    ) and select
    The system displays the Change Parameters: E1 CAS P2 - Australian 
    Network window (Figure 148 on page 298
    ).
    > Change Parameters 
    						
    							5  
    Switch Interface Administration  Digital Interfaces
    Intuity™ CONVERSANT® System Version 7.0 Administration 
    585-313-501 Issue 3 January 2000 298
    Figure 148. Change Parameters:  E1 CAS P2 - Australian Network Window
    2  
    Enter the circuit card number in the 
    Card Number:
     field, or press 
    F2
     
    (Choices) to select from a menu. Initially, all fields are populated with the 
    current values for the circuit card number entered.
    3  
    Change any of the parameters as described in Assign E1 CAS P2 - Australian Network Protocol to E1 Circuit Cards
     on page 294
    .
    4  
    Press 
    F3
     (Save).
    The system saves the changed parameters. 
    						
    							5  
    Switch Interface Administration  Digital Interfaces
    Intuity™ CONVERSANT® System Version 7.0 Administration 
    585-313-501 Issue 3 January 2000 299
    Display E1 CAS P2 - Australian Network ParametersThe E1 circuit card must first be assigned to the E1 CAS P2 - Australian 
    Network protocol to use this procedure. See Assign E1 CAS P2 - Australian Network Protocol to E1 Circuit Cards
     on page 294
    , for more information 
    about making the initial assignment.
    Use the following procedure to display the E1 CAS P2 - Australian Network 
    parameters of an E1 circuit card:
    1  
    Start at the E1 CAS P2 - Australian Network menu (Figure 146 on page 293
    ) and select
    The system displays the Display Parameters: E1 CAS P2 - Australian 
    Network window (Figure 149 on page 300
    ).
    > Display Parameters 
    						
    							5  
    Switch Interface Administration  Digital Interfaces
    Intuity™ CONVERSANT® System Version 7.0 Administration 
    585-313-501 Issue 3 January 2000 300
    Figure 149. Display Parameters:  E1 CAS P2 - Australian Network Window
    2  
    Enter the circuit card number in the 
    Card Number:
     field, or press 
    F2
     
    (Choices) to select from a menu.
    The system displays the parameter values for the selected circuit card.
    3  
    Press F6 (Cancel) to return to the E1 CAS P2 - Australian Network menu. 
    						
    							5  
    Switch Interface Administration  Digital Interfaces
    Intuity™ CONVERSANT® System Version 7.0 Administration 
    585-313-501 Issue 3 January 2000 301
    Unassign E1 CAS P2 - Australian Network Protocol to E1 Circuit CardsNote:Before attempting to make any assignment changes to circuit 
    cards, they must be in the “manoos” state. See Equipment State
     
    on page 150
     in Chapter 3, 
    Voice System Administration
     , for 
    additional information.
    Use the following procedure to unassign the E1 CAS P2 - Australian Network 
    protocol:
    1  
    Start at the E1 CAS P2 - Australian Network menu (Figure 146 on page 293
    ) and select
    The system displays the Unassign Card: E1 CAS P2 - Australian Network 
    window (Figure 150 on page 302
    ).
    > Unassign Card 
    						
    							5  
    Switch Interface Administration  Digital Interfaces
    Intuity™ CONVERSANT® System Version 7.0 Administration 
    585-313-501 Issue 3 January 2000 302
    Figure 150. Unassign Card:  E1 CAS P2 - Australian Network Window
    2  
    Enter the circuit card number in the 
    Card Number:
     field, or press 
    F2
     
    (Choices) to select from a menu.
    The system displays the current parameter values for the selected circuit 
    card.
    3  
    Press 
    F3
     (Save).
    The system removes the E1 CAS P2 - Australian Network assignment 
    from the selected circuit card.
    4  
    Press F6 (Cancel) repeatedly to return to the Digital Interfaces menu. 
    						
    							5  
    Switch Interface Administration  Digital Interfaces
    Intuity™ CONVERSANT® System Version 7.0 Administration 
    585-313-501 Issue 3 January 2000 303
    T1 A/B Robbed-bit E&M Protocol
    Make sure that the switch to which the system is connected is programmed 
    with the following options: •
    The T1 interface uses wink start robbed-bit E&M signaling on a link using 
    D4 framing with zero code suppression (ZCS).  
    •
    The E1/T1 interface outpulses dual tone multifrequency (DTMF) tones at 
    7 pulses per second when originating outbound calls and requires DTMF 
    when taking inbound calls.
    Access T1 A/B 
    Robbed-bit E&M 
    Menu
    Use the following procedure to access the T1 A/B Robbed-bit E&M menu:1  
    Start at the Digital Interfaces menu (Figure 129 on page 248
    ) and select:
    The system displays the T1 A/B Robbed-bit E&M menu (Figure 151 on page 
    304
    ).
    > T1 A/B Robbed-bit E&M 
    						
    							5  
    Switch Interface Administration  Digital Interfaces
    Intuity™ CONVERSANT® System Version 7.0 Administration 
    585-313-501 Issue 3 January 2000 304
    Figure 151. T1 A/B Robbed-bit E&M Menu
    Assign T1 A/B 
    Robbed-bit E&M to 
    Digital Circuit CardsNote:Before a new protocol can be assigned to a circuit card, any 
    existing protocol must first be unassigned. See Unassign T1 A/B 
    Robbed-bit E&M to Digital Circuit Cards
     on page 314
     below for 
    more information.
    Before attempting to make any assignment changes to circuit 
    cards, they must be in the MANOOS state. See Equipment State
     
    on page 150
     in Chapter 3, 
    Voice System Administration
     , for 
    additional information.
    If you change digital protocol assignments on the voice system, 
    you must make the change on the switch as well. 
    						
    							5  
    Switch Interface Administration  Digital Interfaces
    Intuity™ CONVERSANT® System Version 7.0 Administration 
    585-313-501 Issue 3 January 2000 305
    Use the following procedure to assign the T1 A/B Robbed-bit E&M protocol to 
    a digital circuit card:1  
    Start at the T1 A/B Robbed-bit E&M menu (Figure 151 on page 304
    ) and 
    select:
     
    The system displays the Assign Card: T1 A/B Robbed-bit E&M window 
    (Figure 152 on page 306
    ).
    > Assign Card 
    						
    							5  
    Switch Interface Administration  Digital Interfaces
    Intuity™ CONVERSANT® System Version 7.0 Administration 
    585-313-501 Issue 3 January 2000 306
    Figure 152. Assign Card:  T1 A/B Robbed-bit E&M Window  2  
    Enter the circuit card number in the 
    Card Number:
     field, or press 
    F2
     
    (Choices) to select from a menu. Initially, all fields are populated with the 
    default values for the circuit card number entered.
    The 
    Card Number:
     field is blank in Figure 152 on page 306
    . After you 
    enter the circuit card number, certain E1-only fields disappear (
    Idle 
    Code:
    , A-LAW or MU-LAW:
    , and 
    CRC:
    ). 
    						
    All Lucent Technologies manuals Comments (0)