    Have a look at the manual Lucent Technologies Intuity CONVERSANT System Version 7.0 Guide online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 413 Lucent Technologies manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.

    Page
    of 1206
    							3  
    Voice System Administration  Host Configuration
    Intuity™ CONVERSANT® System Version 7.0 Administration 
    585-313-501 Issue 3 January 2000 87
    4  
    Press 
    F3
     (Save).
    The system stores the information to use the next time it processes a 
    Display Host Sessions request.
    Print a Host Sessions ReportUse the following procedure to print a report showing all host sessions 
    currently defined:1  
    Start at the Host Sessions: Actions Menu (Figure 57 on page 85
    ) and 
    select: 
    The system sends the Display Host Sessions window to the system 
    printer.
    Note:This report will not print if a printer has not been configured for use 
    with the voice system. See Printer Administration
     on page 427
     in 
    Chapter 7, 
    Peripheral Administration
     , for more information about 
    printer administration.
    > Print 
    						
    							3  
    Voice System Administration  Host Configuration
    Intuity™ CONVERSANT® System Version 7.0 Administration 
    585-313-501 Issue 3 January 2000 88
    Access the SDLC Protocol Menu
    Use the SDLC Protocol menu to perform the following procedures:•
    Add an SDLC Protocol
     on page 89
    l
    •
    Change an SDLC Protocol
     on page 92
    •
    Deleting an SDLC Protocol
     on page 94
    •
    Diagnose the SDLC Connection
     on page 95
    l
    •
    Display an SDLC Protocol
     on page 96
    •
    View SDLC Connection Information
     on page 97
    •
    Rename an SDLC Protocol
     on page 98
    Use the following procedure to access the SDLC protocol menu:1  
    Start at the Host Configuration menu (Figure 46 on page 67
    ) and select: 
    The system displays the SDLC Protocol menu (Figure 59 on page 89
    ).
    > SDLC Protocol 
    						
    							3  
    Voice System Administration  Host Configuration
    Intuity™ CONVERSANT® System Version 7.0 Administration 
    585-313-501 Issue 3 January 2000 89
    Figure 59. SDLC Protocol Menu  
    Add an SDLC 
    Protocol
    Use the following procedure to add an SDLC protocol:1  
    Start at the SDLC Protocol menu (Figure 46 on page 67
    ) and select: 
    The system displays the Add SDLC Protocol window (Figure 60 on page 
    90
    ). 
    > Add 
    						
    							3  
    Voice System Administration  Host Configuration
    Intuity™ CONVERSANT® System Version 7.0 Administration 
    585-313-501 Issue 3 January 2000 90
    Figure 60. Add SDLC Protocol Window  
    Table 5 on page 91
     describes the fields on this window.
    2  
    Enter the information described in Table 5 on page 91
    .
    3  
    Press 
    F3
     (Save).
    The system adds the SDLC Protocol with the selected parameters. 
    						
    							3  
    Voice System Administration  Host Configuration
    Intuity™ CONVERSANT® System Version 7.0 Administration 
    585-313-501 Issue 3 January 2000 91
     
    Table 5. Field Descriptions for SDLC Protocols
    Field Name DescriptionConnection 
    Name:
    Identifies a logical connection to a host. The default value is SDLCn, where 
    n 
    is the circuit card number.
    Card 
    Number:
    Indicates which communications adapter circuit card this connection uses.  
    The default value is 1 unless circuit card number 1 is in use; then the default 
    is 2.
    Line Type:
    Specifies the type of physical line being used.  The default value is leased.
    Node ID to 
    Send:
    An 8-digit hexadecimal number that specifies the ID that is sent to the remote 
    computer.  The number is divided into a 3-digit block number and a 5-digit 
    node number.  Values 000 and FFF cannot be used for the block number, 
    and 00000 cannot be used for the node number. Valid values range from 
    00100001 to FFEFFFFF.  The default value is blank (no node ID to send).
    Encoding:
    Specifies the encoding scheme of the modem for transmitting and receiving 
    data.  Valid values are nrz and nrzi.  The default value is nrz.
    Constant 
    Carrier:
    Specifies whether the system will keep the RTS signal high.  If Yes, the 
    modem must support constant carrier.  The default value is No.
    1 of 2 
    						
    							3  
    Voice System Administration  Host Configuration
    Intuity™ CONVERSANT® System Version 7.0 Administration 
    585-313-501 Issue 3 January 2000 92
    Change an SDLC 
    Protocol
    Use the following procedure to change SDLC protocol:1  
    Start at the SDLC Protocol menu (Figure 46 on page 67
    ) and select: 
    The system displays the Change SDLC Protocol window (Figure 61 on 
    page 93
    ).
    Poll 
    Address:
    Specifies the polling address of the system.  The poll address is a 
    hexadecimal value that ranges from 00 to FF.  The default value is C1.
    LU:
    Identifies the logical unit number.  Valid values range from 2 to the maximum 
    LU number allowed by the system.  You can enter multiple LUs separated by 
    commas, and a range of LUs using a dash, for example 2, 4–8, 10.
    Table 5. Field Descriptions for SDLC Protocols
    Field Name Description
    2 of 2
    > Change 
    						
    							3  
    Voice System Administration  Host Configuration
    Intuity™ CONVERSANT® System Version 7.0 Administration 
    585-313-501 Issue 3 January 2000 93
    Figure 61. Change SDLC Protocol Window  2  
    Enter the name of the connection you want to change in the 
    Connection 
    Name:
     field, or press 
    F2
     (Choices) to select from a menu.
    3  
    Modify any of the fields as desired using Table 5 on page 91
     as a guide.
    4  
    Press 
    F3
     (Save).
    The system overwrites the host connection with new SDLC information. 
    						
    							3  
    Voice System Administration  Host Configuration
    Intuity™ CONVERSANT® System Version 7.0 Administration 
    585-313-501 Issue 3 January 2000 94
    Deleting an SDLC 
    Protocol
    Use the following procedure to delete SDLC protocol:1  
    Start at the SDLC Protocol menu (Figure 46 on page 67
    ) and select: 
    The system displays the Delete SDLC Protocol window (Figure 62 on 
    page 94
    ).
    Figure 62. Delete SDLC Protocol Window  2  
    Enter the name of the connection you want to delete in the 
    Connection 
    Name:
     field, or press 
    F2
     (Choices) to select from a menu.
    3  
    Press 
    F3
     (Delete).
    The system deletes the specified connection.
    > Delete 
    						
    							3  
    Voice System Administration  Host Configuration
    Intuity™ CONVERSANT® System Version 7.0 Administration 
    585-313-501 Issue 3 January 2000 95
    Diagnose the SDLC 
    Connection
    Use the following procedure to diagnose one SDLC connection or all SDLC 
    connections:1  
    Start at the SDLC Protocol menu (Figure 46 on page 67
    ) and select: 
    The system displays the Diagnose SDLC Connection window 
    (Figure 63
    ).
    Figure 63. Diagnose SDLC Connection Window  2  
    Enter the connection name or all in the 
    Connection Name:
     field, or press 
    F2
     (Choices) to select from a menu.
    3  
    Press 
    F3
     (Diagnose).
    The system diagnoses the selected SDLC connection and displays the 
    results.
    > Diagnose 
    						
    							3  
    Voice System Administration  Host Configuration
    Intuity™ CONVERSANT® System Version 7.0 Administration 
    585-313-501 Issue 3 January 2000 96
    Display an SDLC 
    Protocol
    Use the following procedure to display an SDLC protocol:1  
    Start at the SDLC Protocol menu (Figure 46 on page 67
    ) and select: 
    The system displays the Display SDLC Protocol window (Figure 64 on 
    page 96
    ).
    Figure 64. Display SDLC Protocol Window  2  
    Enter the name of the connection in the 
    Connection Name:
     field, or press 
    F2
     (Choices) to select from a menu. 
    The system fills in the remaining fields.
    3  
    Press 
    F3
     (Display).
    The system displays information about the selected SDLC protocol.
    > Display 
    						