    Have a look at the manual Lucent Technologies Intuity CONVERSANT System Version 7.0 Guide online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 413 Lucent Technologies manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.

    Page
    of 1206
    							4  
    Feature Package Administration  ASAI Administration
    Intuity™ CONVERSANT® System Version 7.0 Administration 
    585-313-501 Issue 3 January 2000 217
    Disable a Domain
    Use the following procedure to take a domain out of service:1  
    Start at the Domain Administration window (Figure 119 on page 208
    ) and 
    press 
    F8
     (Chg-Keys).
    The system displays the alternate function keys.
    2  
    Press
     F5
     (Disable).
    The system changes the 
    Status:
     field to “manoos”.
    Parameter Administration
    Use Parameter Administration menu option to administer:•
    “Connect Event” reporting to the A_Event variable in an application 
    assigned to an ACD, VDN, or CTL domain
    •
    Details displayed with the trace dip7 command to monitor messages and 
    events processed by the ASAI feature
    Note:See Trace Service
     on page 457
     in Chapter 8, 
    Common 
    Administration
      for more information on trace. 
    						
    							4  
    Feature Package Administration  ASAI Administration
    Intuity™ CONVERSANT® System Version 7.0 Administration 
    585-313-501 Issue 3 January 2000 218
    Use the following procedure to set ASAI parameters regarding connect event 
    reporting and the level of trace detail:1  
    Start at the ASAI Administration menu (Figure 115 on page 197
    ) and 
    select:
    The system displays the ASAI Parameters window (Figure 122 on page 
    218
    ).
    Figure 122. ASAI Parameters Window  2  
    Enter either Connected or Alerting in the 
    CONNECT Event:
     field to 
    specify when the Connect event is reported to the A_Event action in a 
    script assigned to an ACD, VDN, or CTL type domain. Or, you may press 
    F2
     (Choices) to select from a menu. The default is Connected.
    > Parameter Administration 
    						
    							4  
    Feature Package Administration  ASAI Administration
    Intuity™ CONVERSANT® System Version 7.0 Administration 
    585-313-501 Issue 3 January 2000 219
    3  
    Enter Low, Normal, or High in the 
    Trace Detail:
     field to specify the 
    amount of trace detail to display. Or, you may press F2
     (Choices) to 
    select from a menu. Table 21 on page 219
     summarizes the trace 
    command settings and the level of detail achieved with each one.
      4  
    Press 
    F3
     (Save).
    The system displays the level of trace detail specified.
    5  
    Press 
    F6
     (Cancel) repeatedly to return to the ASAI Administration menu 
    (Figure 115 on page 197
    ).
    Table 21. Trace Detail Display Settings
    Setting DisplayLow
    Information displayed about ASAI error and warning 
    conditions.
    Normal
    All information displayed by the Low setting, plus ASAI 
    script action (that is, A_Callinfo, A_Tran, A_Event, and 
    A_RouteSel).
    High
    All information displayed by the Low and Normal settings, 
    plus call event descriptions received from the PBX. 
    						
    							4  
    Feature Package Administration  ASAI Administration
    Intuity™ CONVERSANT® System Version 7.0 Administration 
    585-313-501 Issue 3 January 2000 220
    Show the ASAI Software Version
    This procedure displays the version information about the ASAI software 
    loaded onto the voice system. 
    Use the following procedure to show the ASAI software version:1  
    Start at the ASAI Administration menu (Figure 115 on page 197
    ) and 
    select:
    The system displays the Show ASAI Software Version window
    (Figure 123 on page 221
    ).
    > Show ASAI Software Version 
    						
    							4  
    Feature Package Administration  ASAI Administration
    Intuity™ CONVERSANT® System Version 7.0 Administration 
    585-313-501 Issue 3 January 2000 221
    Figure 123. Show ASAI Software Version Window  2  
    Press 
    ENTER
    .
    The system returns to the ASAI Administration menu (Figure 115 on page 
    197
    ). 
    						
    							4  
    Feature Package Administration  ASAI Administration
    Intuity™ CONVERSANT® System Version 7.0 Administration 
    585-313-501 Issue 3 January 2000 222
    Show the Status of the ASAI Link
    Note:The ASAI link must be administered on the DEFINITY® switch. 
    See 
    DEFINITY Communications System Generic 3i 
    Implementation
    , 555-230-650, for more information.
    Use the following procedure to display the current maintenance state of the 
    ASAI link using a LAN connection to the switch:
    1  
    Start at the ASAI Administration menu (Figure 115 on page 197
    ) and 
    select:
    The system displays the Show Status of ASAI Link window (Figure 124 
    on page 222
    ).
    Figure 124. Show Status of ASAI Link Window (LAN)  > Show Status of ASAI Link 
    						
    							4  
    Feature Package Administration  UCID Administration
    Intuity™ CONVERSANT® System Version 7.0 Administration 
    585-313-501 Issue 3 January 2000 223
    Table 22 on page 223
     describes the messages that appear on the Show 
    Status of ASAI Link screen if the LAN link is experiencing problems. 
     2  
    Press 
    ENTER
    .
    The system returns to the ASAI Administration menu.
    UCID Administration
    The UCID Administration screen allows you to select the UCID network node 
    identifier for an Intuity CONVERSANT system. 
    Use the following procedure to access the UCID Administration menu:1  
    At the 
    Console Login:
     prompt, enter root
    The system prompts you for a password.
    2  
    Enter your root password.
    The system displays the system prompt #.Table 22. Show Status ASAI Link (LAN) Messages
    Status Message DescriptionLAN is Talking
    LAN connection is on-line.
    LAN is Quiet
    LAN connection is off-line. 
    						
    							4  
    Feature Package Administration  UCID Administration
    Intuity™ CONVERSANT® System Version 7.0 Administration 
    585-313-501 Issue 3 January 2000 224
    3  
    Enter cvis_menu
    The system displays the Voice System Administration menu (Figure 42 on page 59
    ).
    4  
    Select:
    The system displays the Universal Call ID Administration screen (Figure 125 on page 224
    ).
    Figure 125. Universal Call ID Administration Screen  
    > UCID Administration
    > Feature Packages 
    						
    							4  
    Feature Package Administration  UCID Administration
    Intuity™ CONVERSANT® System Version 7.0 Administration 
    585-313-501 Issue 3 January 2000 225
    5  
    Enter a 
    UCID Network Node ID
    . This value is used to uniquely identify 
    this Intuity CONVERSANT system within a DEFINITY Enterprise 
    Communication System (ECS) Call Center. Each node (DEFINITY ECS, 
    Intuity CONVERSANT, etc.) must have a distinct UCID Network Node ID. 
    Valid values are:
    ~
    NONE — This node is not administered with a node number
    ~
    nnnnn
     — A number between 1 and 32767
    Note:The recommended range for Intuity CONVERSANT systems is 
    10000 to 19999.
    6  
    Press 
    F3
     (Save) to save the values.
    7  
    Press 
    F3
     (Cancel) twice to exit the screen and return to the Voice System 
    Administration menu.
    Note:In order for changes to take affect for UCID administration, stop 
    and start the voice system. See Stop the Voice System
     on page 
    136
     and Start the Voice System
     on page 139
     in Chapter 3, 
    Vo ic e  
    System Administration
     . 
    						
    							Intuity™ CONVERSANT® System Version 7.0 Administration 
    585-313-501 Issue 3 January 2000 226
    5 
    Switch Interface Administration
    Overview
    The Switch Interfaces menu lets you to define the interaction between the 
    Intuity CONVERSANT system and the switches connected to it by allowing 
    you to modify switch interface parameters and protocol options for both 
    analog and digital interfaces.
    This chapter provides procedural information and reference information for 
    administering the supported analog and digital switch interfaces. 
    						