    Have a look at the manual Lucent Technologies Intuity CONVERSANT System Version 7.0 Guide online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 413 Lucent Technologies manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.

    Page
    of 1206
    							5  
    Switch Interface Administration  Digital Interfaces
    Intuity™ CONVERSANT® System Version 7.0 Administration 
    585-313-501 Issue 3 January 2000 287
    Change E1 CAS P2 - Australian DEFINITY ParametersThe E1 circuit card must first be assigned to the E1 CAS P2 - Australian 
    DEFINITY protocol to use this procedure. See Assign E1 CAS P2 - Australian DEFINITY Protocol to E1 Circuit Cards
     on page 284
    , for more information 
    about making the initial assignment.
    Note:Before attempting to make any assignment changes to circuit 
    cards, they must be in the “manoos” state. See Equipment State
     
    on page 150
     in Chapter 3, 
    Voice System Administration
     , for 
    additional information.
    If you change digital protocol assignments on the voice system, 
    you must make the change on the switch as well.
    Use the following procedure to change the E1 CAS P2 - Australian DEFINITY 
    parameters:
    1  
    Start at the E1 CAS P2 - Australian DEFINITY menu (Figure 141 on page 283
    ) and select
    The system displays the Change Parameters: E1 CAS P2 - Australian 
    DEFINITY window (Figure 143 on page 288
    ).
    > Change Parameters 
    						
    							5  
    Switch Interface Administration  Digital Interfaces
    Intuity™ CONVERSANT® System Version 7.0 Administration 
    585-313-501 Issue 3 January 2000 288
    Figure 143. Change Parameters:  E1 CAS P2 - Australian DEFINITY Window  2  
    Enter the circuit card number in the 
    Card Number:
     field, or press 
    F2
     
    (Choices) to select from a menu. Initially, all fields are populated with the 
    current values for the circuit card number entered.
    3  
    Change any of the parameters described in Assign E1 CAS P2 - Australian DEFINITY Protocol to E1 Circuit Cards
     on page 284
    .
    4  
    Press 
    F3
     (Save).
    The system saves the changed parameters. 
    						
    							5  
    Switch Interface Administration  Digital Interfaces
    Intuity™ CONVERSANT® System Version 7.0 Administration 
    585-313-501 Issue 3 January 2000 289
    Display E1 CAS P2 - Australian DEFINITY ParametersThe E1 circuit card must first be assigned to the E1 CAS P2 - Australian 
    DEFINITY protocol to use this procedure. See Assign E1 CAS P2 - Australian DEFINITY Protocol to E1 Circuit Cards
     on page 284
    , for more information 
    about making the initial assignment.
    Use the following procedure to display the E1 CAS P2 - Australian DEFINITY 
    parameters of an E1 circuit card:
    1  
    Start at the E1 CAS P2 - Australian DEFINITY menu (Figure 141 on page 283
    ) and select
     
    The system displays the Display Parameters: E1 CAS P2 - Australian 
    DEFINITY window (Figure 144 on page 290
    ).
    > Display Parameters 
    						
    							5  
    Switch Interface Administration  Digital Interfaces
    Intuity™ CONVERSANT® System Version 7.0 Administration 
    585-313-501 Issue 3 January 2000 290
    Figure 144. Display Parameters:  E1 CAS P2 - Australian DEFINITY Window  2  
    Enter the circuit card number in the 
    Card Number:
     field, or press 
    F2
     
    (Choices) to select from a menu.
    The system displays the parameter values for the selected circuit card.
    3  
    Press F6 (Cancel) to return to the E1 CAS P2 - Australian DEFINITY 
    menu. 
    						
    							5  
    Switch Interface Administration  Digital Interfaces
    Intuity™ CONVERSANT® System Version 7.0 Administration 
    585-313-501 Issue 3 January 2000 291
    Unassign E1 CAS P2 - Australian DEFINITY Protocol to E1 Circuit Cards  Note:Before attempting to make any assignment changes to circuit 
    cards, they must be in the “manoos” state. See Equipment State
     
    on page 150
     in Chapter 3, 
    Voice System Administration
     , for 
    additional information. 
    						
    							5  
    Switch Interface Administration  Digital Interfaces
    Intuity™ CONVERSANT® System Version 7.0 Administration 
    585-313-501 Issue 3 January 2000 292
    Use the following procedure to unassign the E1 CAS P2 - Australian 
    DEFINITY protocol:1  
    Start at the E1 CAS P2 - Australian DEFINITY menu (Figure 141 on page 283
    ) and select
     
    The system displays the Unassign Card: E1 CAS P2 - Australian 
    DEFINITY window (Figure 145 on page 292
    ).
    Figure 145. Unassign Card:  E1 CAS P2 - Australian DEFINITY Window
    2  
    Enter the circuit card number in the 
    Card Number:
     field, or press 
    F2
     
    (Choices) to select from a menu.
    The system displays the current parameter values for the selected circuit 
    card.
    3  
    Press 
    F3
     (Save).
    The system removes the E1 CAS P2 - Australian DEFINITY assignment 
    from the selected circuit card.
    4  
    Press F6 (Cancel) repeatedly to return to the Digital Interfaces menu.> Unassign Card 
    						
    							5  
    Switch Interface Administration  Digital Interfaces
    Intuity™ CONVERSANT® System Version 7.0 Administration 
    585-313-501 Issue 3 January 2000 293
    E1 CAS P2 - 
    Australian Network 
    ProtocolAccess E1 CAS P2 - Australian Network Menu
    Use the following procedure to access the E1 CAS P2 - Australian Network 
    protocol menu:1  
    Start at the Digital Interfaces menu (Figure 129 on page 248
    ) and select
    The system displays the E1 CAS P2 - Australian Network menu (Figure 
    146 on page 293
    ).
    Figure 146. E1 CAS P2 - Australian Network Menu  Use the following procedures to assign/unassign the E1 CAS P2 - Australian 
    Network protocol to digital circuit cards, and administer the switch interface 
    parameters.> E1 CAS P2 - Australian Network 
    						
    							5  
    Switch Interface Administration  Digital Interfaces
    Intuity™ CONVERSANT® System Version 7.0 Administration 
    585-313-501 Issue 3 January 2000 294
    Assign E1 CAS P2 - Australian Network Protocol to E1 Circuit CardsNote:Before a new protocol can be assigned to a circuit card, any 
    existing protocol must first be “unassigned.” See Unassign E1 
    CAS P2 - Australian Network Protocol to E1 Circuit Cards
     on page 
    301
     for more information.
    Before attempting to make any assignment changes to circuit 
    cards, they must be in the “manoos” state. See Equipment State
     
    on page 150
     in Chapter 3, 
    Voice System Administration
     , for 
    additional information.
    If you change digital protocol assignments on the voice system, 
    you must make the change on the switch as well.
    Use the following procedure to assign the E1 CAS P2 - Australian Network 
    protocol to an E1 circuit card:
    1  
    Start at the E1 CAS P2 - Australian Network menu (Figure 146 on page 293
    ) and select
    The system displays the Assign Card: E1 CAS P2 - Australian Network 
    window (Figure 147 on page 295
    ).
    > Assign Card 
    						
    							5  
    Switch Interface Administration  Digital Interfaces
    Intuity™ CONVERSANT® System Version 7.0 Administration 
    585-313-501 Issue 3 January 2000 295
    Figure 147. Assign Card:  E1 CAS P2 - Australian Network Window  2  
    Enter the circuit card number in the 
    Card Number:
     field, or press 
    F2
     
    (Choices) to select from a menu. Initially, all fields are populated with the 
    default values for the circuit card number entered.
    3  
    Enter the values as shown in Table 30 on page 296
     for each of the fields 
    in the window. 
    						
    							5  
    Switch Interface Administration  Digital Interfaces
    Intuity™ CONVERSANT® System Version 7.0 Administration 
    585-313-501 Issue 3 January 2000 296
    4  
    Press 
    F3
     (Save).
    The system saves the parameter information and assigns the E1 CAS P2 
    - Australian Network protocol to the selected E1 circuit card.
    Table 30. Parameter Values for Assign Card: E1 CAS P2 - Australian 
    Network Window
    Field Name Enter ValueFraming/Line Coding:
    CEPTHDB3
    Idle Code:
    01010100
    DTMF Muting:
    Yes
    A-LAW or MU-LAW:
    A-LAW
    CRC:
    Yes
    Max. Digits in Called Number:
    4
    Outgoing Addressing Type:
    DTMF
    Incoming Addressing Type:
    DTMF
    Incoming Speech Volume:
    1414
    Outgoing Speech Volume:
    707 
    						
    All Lucent Technologies manuals Comments (0)