Home > Lucent Technologies > Communications System > Lucent Technologies Definity Audix System Digital Networking Guide

Lucent Technologies Definity Audix System Digital Networking Guide

    Download as PDF Print this page Share this page

    Have a look at the manual Lucent Technologies Definity Audix System Digital Networking Guide online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 413 Lucent Technologies manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.

    							DEFINITY AUDIX System Digital Networking  585-300-534  Issue 2
    May 1999
    DCP Mode 2 — 9600 or 19,200 bps 
    4-17 Switch Administration Requirements for DCP Mode 2 
    4
    Figure 4-13. Modem Switch Hunt Group – Group Member Assignments 
    						
    							DEFINITY AUDIX System Digital Networking  585-300-534  Issue 2
    May 1999
    DCP Mode 2 — 9600 or 19,200 bps 
    4-18 Switch Administration Requirements for DCP Mode 2 
    4
    The following sc reen shows Pag e 1 of the remote Mac hine Profile sc reen on 
    DEFINITY AUDIX A to set up  a networking  c onnec tion with DEFINITY AUDIX B. 
    Figure 4-14. Remote Machine Profile Screen — Page 1 to Call DEFINITY 
    AUDIX B 
    						
    							DEFINITY AUDIX System Digital Networking  585-300-534  Issue 2
    May 1999
    DCP Mode 2 — 9600 or 19,200 bps 
    4-19 Switch Administration Requirements for DCP Mode 2 
    4
    The following sc reen shows Pag e 2 of the remote Mac hine Profile sc reen on 
    DEFINITY AUDIX A to set up  a networking  c onnec tion with DEFINITY AUDIX B.
    Figure 4-15. Remote Machine Profile Screen — Page 2 to Call DEFINITY 
    AUDIX B 
    						
    							DEFINITY AUDIX System Digital Networking  585-300-534  Issue 2
    May 1999
    DCP Mode 2 — 9600 or 19,200 bps 
    4-20 Switch Administration Requirements for DCP Mode 2 
    4 
    						
    							DCP Mode 1 — 56 Kbps 
    5-1 Considerations 
    5
    DEFINITY AUDIX System Digital Networking  585-300-534  Issue 2
    May 1999
    5
    DCP Mode 1 — 56 Kbps
    This c hapter d esc rib es Dig ital Communic ations Protoc ol (DCP) Mod e 1. Mod e 1 
    is a hig h-sp eed , 56 Kb p s network c onnec tion. Use it when the systems to b e 
    networked  are in d ifferent loc ations and  req uire some typ e of interloc ation fac ility 
    to c ommunic ate.
    NOTE:
    DCP Mod e 3 is rec ommend ed  for loc al networking on the same G3r switc h 
    b etween a DEFINITY AUDIX system and  an Intuity AUDIX system or an 
    AUDIX R1 system. See Chapter 3, ‘‘DCP Mode 3 — 64 Kbps’’
    , for a 
    description of DCP Mode 3.
    This c hap ter presents sup p orted  56 Kb p s c onfig urations for the DEFINITY AUDIX 
    system; all other 56 Kb ps c onfig urations must b e d esig ned  b y c ustom 
    d evelop ment. The examp le in this c hap ter shows two DEFINITY AUDIX systems 
    using DCP Mod e 1 at b oth loc ations. See Chap ter 6
     for a d esc rip tion of networks 
    that c omb ine DCP mod es.
    Considerations
    If a c ustomer is c onsid ering  using  DCP Mod e 1 c onnec tions in their DEFINITY 
    AUDIX network, keep  the following  in mind :
    nDCP Mod e 1 is not rec ommend ed for loc al networking  c onfig urations 
    (DCP Mode 3 is rec ommend ed  for loc al c onnec tions).
    nThe DEFINITY AUDIX system c an network with other DEFINITY AUDIX 
    systems, Intuity AUDIX systems, and  AUDIX R1 systems using  this 
    method .
    nTransmission in this typ e of network is full-dup lex, sync hronous, at 56 
    Kbps. 
    						
    							DEFINITY AUDIX System Digital Networking  585-300-534  Issue 2
    May 1999
    DCP Mode 1 — 56 Kbps 
    5-2 General Information 
    5
    nThe c ustomer also will need  a DS1 interfac e on the switc h to c onnec t with 
    the 56 Kb p s fac ility.
    nThe c ustomer will need  ac c ess to 56 Kbp s rob bed -b it fac ilities at a static  
    or d ynamic  serving offic e (SO).
    nLong distance, 56 Kbps service may be provided by a long distance 
    servic e p rovid er.
    General Information
    To use DCP Mod e 1 as the transmission p rotoc ol, the switc h must b e set up  to 
    ac c ess a switc hed  network at 56 Kb p s via rob b ed -b it fac ilities. These sp ec ial 
    ac c ess lines c an b e either AT&T Datap hone Dig ital Servic e (DDS) or ACCUNET 
    T1.5, AT&T Software Defined  Network (SDN) servic e p rovid ing  ac c ess to either a 
    static  or d ynamic  Serving  Offic e (SO), or c omp atible servic es provid ed  b y other 
    vend ors. Currently the System 75, DEFINITY Generic  1, and  DEFINITY Generic  3 
    c an p rovid e this typ e of ac c ess.
    The following fig ure, DCP Mod e 1 Network Using  Switc hed  56 Servic e
    , shows 
    two DEFINITY AUDIX systems networked  via 56 Kb p s servic es. 
    NOTE:
    If the c ustomer d oes not sub sc rib e to switc hed  56 servic e, c onsid er the 
    DCP Mod e 2 or DCP Mod e 3 network alternatives b efore setting  up  a 
    switc hed  56 Kb p s fac ility. It is rec ommend ed  that 64 Kb p s c onnec tions be 
    used  to ac hieve maximum d ata throug hp ut whenever 64 Kb p s c onnec tivity 
    is available between two systems. 
    						
    							DEFINITY AUDIX System Digital Networking  585-300-534  Issue 2
    May 1999
    DCP Mode 1 — 56 Kbps 
    5-3 General Information 
    5
    Figure 5-1. DCP Mode 1 Network Using Switched 56 Service
    Static Access
    Static  Software Defined Data Network (SDDN) allows c ustomers c urrently 
    sub sc rib ing  to SDN voic e ap p lic ations to transmit d ata on the same ac c ess 
    arrang ement b y d efining  a sub g roup  for d ata. Customers using  this c onfig uration 
    must have a trunk subgroup (TSG) dedicated to SDDN 56 Kbps between the 
    c ustomer p remises and  a c entral offic e. They must also have a System 75 R1V3 
    Issue 2.2 or later, a DEFINITY Generic  1, or a DEFINITY Generic  3 switc h.
    The c entral offic e must p rovid e one of the following :
    nAT&T Software Defined  Network (SDN), T1.5, or Datap hone Dig ital Servic e 
    (DDS) and  Switc hed  Digital Servic e (SDS), or c omp atible servic e offered  
    b y another vend or
    nA 4ESS supp orting  56 Kb p s servic e
    DEFINITY
    AUDIX
    DEFINITY
    AUDIX DS1 port
    DS1 portPBX
    PBX T1
    T1
    Po i n t -o f -
    Presence
    switch
    Po i n t -o f -
    Presence
    switch
    Switched
    56 service 
    						
    							DEFINITY AUDIX System Digital Networking  585-300-534  Issue 2
    May 1999
    DCP Mode 1 — 56 Kbps 
    5-4 DEFINITY AUDIX Requirements for DCP Mode 1 
    5
    A c ustomer c annot use this op tion if they have the following :
    nT1.5 ac c ess to a c entral offic e tariffed  for SDN 
    nT1.5 that d oes not orig inate from a 4ESS with Switc hed  Dig ital Servic e 
    (SDS)
    Dynamic Access
    Dynamic  SDDN (non-ISDN) allows c ustomers that c urrently sub sc rib e to SDN 
    voic e ap p lic ations to transmit d ata on the same ac c ess arrang ement b y p refixing  
    a 115 feature c od e in front of a telep hone numb er. This allows c ustomers to 
    alternately transmit voic e and  d ata on one ac c ess line; a sep arate trunk g roup  for 
    56 Kbps data is not required.
    The T1.5 is d edic ated  to SDN and  is therefore not exc lusively 56 Kb p s. The 
    c entral offic e must route to a 4ESS that sup p orts 56 Kb p s via dig ital c onnec tivity. 
    This ac c ess may only b e offered  on c irc uits without ec ho c anc ellation.
    The d ynamic  arrang ement is not p ossib le from loc ations using  Datap hone Dig ital 
    Servic e (DDS) ac c ess. DDS lines must terminate in a c entral offic e that has been 
    tariffed for Software Defined  Network (SDN), DDS, and  Switc hed  Dig ital Servic e 
    (SDS).
    System 75 R1V3, DEFINITY Generic  1, and  DEFINITY Generic  3 sup port d ynamic  
    ac c ess b ut have sp ec ial req uirements suc h as c irc uit p ac ks.
    NOTE:
    DEFINITY AUDIX d ig ital networking throug h tand em switc hes may not 
    work. Contac t the d esig n c enter for these d esigns.
    DEFINITY AUDIX Requirements for 
    DCP Mode 1
    Eac h DEFINITY AUDIX system req uiring  ac c ess to a switc hed  56 network must 
    b e running R3.2 or later software.  
    						
    							DEFINITY AUDIX System Digital Networking  585-300-534  Issue 2
    May 1999
    DCP Mode 1 — 56 Kbps 
    5-5 Switch (or Customer) Requirements for DCP Mode 1 
    5
    Switch (or Customer) Requirements 
    for DCP Mode 1
    To imp lement DEFINITY AUDIX networking  over static  or d ynamic  switc hed  56 
    Kb p s fac ilities, the c ustomers switc h must have a DS1 interfac e to c onnec t with 
    the 56 Kb p s switc hed  network. See the System Desc rip tion for the switc h to see 
    whic h c irc uit p ac ks will meet this req uirement.
    NOTE:
    DEFINITY AUDIX d ig ital networking throug h tand em switc hes may not 
    work. Contac t the d esig n c enter for these d esigns.
    Whether a c ustomer is using  static  or d ynamic  56 Kb p s, the p oint-of-p resenc e 
    switc h need s to b e translated  to matc h the switc h (inc lud ing  wink in/wink out). 
    The RNXs are set up  b y the c ustomer and  ad d ed  to the network b y AT&T 
    Network Systems or another vend or. 
    NOTE:
    Contac t the d esig n c enter to d esig n ISDN.
    NOTE:
    See the DEFINITY Communic ations System Generic  2.2 and  Generic  3 
    Version 2 DS1/CEPT1/ISDN-PRI Referenc e
     (555-025-107) for ad ministering  
    DS1 trunks on the DEFINITY switc h.
    Static Access Switch Requirements
    The req uirements for networking  DEFINITY AUDIX systems via static  56 Kb p s 
    fac ilities d ep end  on the c ustomers p remises switc h:
    nSystem 75
    — The switc h must b e R1V3 2.2 or later.
    — All tone d etec tors must b e TN748C (V4 or later).
    nDEFINITY Generic  1 and  Generic  3 
    — Any release will sup p ort static  56 Kb p s ac c ess.
    — All tone d etec tors must b e TN748C (V4 or later).
    — The tone c loc ks must b e TN786 and  TN741. 
    						
    							DEFINITY AUDIX System Digital Networking  585-300-534  Issue 2
    May 1999
    DCP Mode 1 — 56 Kbps 
    5-6 Data Rates for DCP Mode 1 
    5
    Dynamic Access Switch Requirements
    The req uirements for networking  DEFINITY AUDIX systems via d ynamic  56 Kb p s 
    fac ilities d ep end  on the c ustomer premises switc h:
    nSystem 75
    — The switc h must b e R1V3 2.2 or later.
    — All tone d etec tors must b e TN748C (V4 or later).
    nDEFINITY Generic  1 and  Generic  3
    — Any release will sup p ort dynamic  56 Kb p s ac c ess.
    — All tone d etec tors must b e TN748C (V4 or later).
    — The tone c loc ks must b e TN786 and  TN741.
    Data Rates for DCP Mode 1
    The c onfig urations shown in this c hap ter op erate at 56 Kb ps.
    The following fig ure shows Page 1 of the remote Mac hine Profile sc reen for 
    c alling  a remote system using  a d ata rate of 56 Kb p s.
    Figure 5-2. Machine Profile Screen for Remote System 56 Kbps Call, page 1 
    						