Have a look at the manual Lucent Technologies Definity Audix System Digital Networking Guide online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 413 Lucent Technologies manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.
Hardware Installation for DCP Mode 2 8-1 8 DEFINITY AUDIX System Digital Networking 585-300-534 Issue 2 May 1999 8 Hardware Installation for DCP Mode 2 This c hapter d esc rib es the hard ware installation and c onnec tion testing for DCP Mod e 2 networking c onnec tions. The following information is also inc lud ed: nMod em front panel setting s for the Parad yne Comsp here 3800 series modem and a procedure for configuring the front panel settings n7400A op tion setting s whic h need to b e set using the 7400A front p anel DEFINITY AUDIX DCP Mod e 2 uses one of the following typ es of mod em/d ata mod ule arrang ements: nDCP port (TN754), 7400A data module, modem, and analog port nElec tronic Ind ustries Assoc iation (EIA p ort), async hronous d ata unit (ADU), modem, and analog port
DEFINITY AUDIX System Digital Networking 585-300-534 Issue 2 May 1999 Hardware Installation for DCP Mode 2 8-2 Hardware Installation Using a 7400A Data Module 8 Hardware Installation Using a 7400A Data Module You need the following eq uip ment: n7400A Data Mod ule and 7400A p ower sup p ly nM7U null-mod em c ab le (male-male) (3 feet) n103A or wall jac k (2 for eac h mod em/d ata mod ule arrangement) nD8W c ord (14 feet) nCompatible modem (refer to Chap ter 4, ‘‘DCP Mod e 2 — 9600 or 19,200 bps’’, for a list of c omp atib le mod ems) NOTE: Refer to Fi g u re 8 - 1, 7400A Data Mod ule in a DCP Mod e 2 Mod em/Data Mod ule Arrang ement. 1. Use the 7400A front p anel to set the 7400A op tions. Refer to 7400A Op tion Setting s later in this c hapter. 2. Use a D8W wall c ord to c onnec t the 7400A Data Mod ule to the 103A or wall jack. 3. To c onnec t the 7400A Data Mod ule to the c omp atib le mod em, use an M7U null-mod em c ab le (male-male). 4. Use a 2/4 Wire Line Cord to c onnec t the Parad yne Mod em to the 103A or wall jack This c omp letes the hard ware installation using a 7400A Data Mod ule. The following tasks in Chap ter 9, ‘‘Initial Network Ad ministration and Ac c ep tanc e Tests’’, need to b e c omp leted before the installation is c omp lete: nTask 9: Ad minister Remote System(s) on the Loc al DEFINITY AUDIX Sys t e m. nTask 10: Ad minister the DEFINITY AUDIX on the Remote Mac hine(s) nTask 11: Test the Connec tion to Eac h Remote System Complete Chap ter 9.
DEFINITY AUDIX System Digital Networking 585-300-534 Issue 2 May 1999 Hardware Installation for DCP Mode 2 8-3 Hardware Installation Using a 7400A Data Module 8 Figure 8-1. 7400A Data Module in a DCP Mode 2 Modem/Data Module Arrangement DEFINITY AUDIXTN754 circuit pack TN747 circuit pack TN742 or TN746B analog circuit pack To public network PBX Switched Switched Cross connect Cross connect 103A or wall jack 103A or wall jack 3800 series modem D8W-87 2/4 wire line cord 7400A data module M7U
DEFINITY AUDIX System Digital Networking 585-300-534 Issue 2 May 1999 Hardware Installation for DCP Mode 2 8-4 Hardware Installation Using an ADU 8 Hardware Installation Using an ADU You need the following eq uip ment: nADU (Z3A-2) M8J-82 c ab le is inc lud ed . nH-600-258, Group 1 null-mod em c ab le (male-female) (12 inc hes) n103A wall jac k (2 for eac h modem/d ata mod ule arrang ement) nD8W c ord (14 feet) nCompatible modem (refer to Chap ter 4, ‘‘DCP Mod e 2 — 9600 or 19,200 bps’’, for a list of c omp atib le mod ems) NOTE: Refer to Fi g u re 8 - 2, ADU in a DCP Mod e 2 Mod em/Data Mod ule Arrangement. 1. Use a D8W wall c ord to c onnec t the ADU to the 103A or wall jac k. 2. Connec t one end of the M8J-82 c ab le that c ame with the ADU to the ADU. 3. Connec t the male end of the M8J-82 c ab le to the female end of the H-600-258, Group 1 c ab le. 4. Connec t the male end of the H-600-258, Group 1 c ab le to the mod em. 5. Use a 2/4 Wire Line Cord to c onnec t the Parad yne Mod em to the 103A or wall jack. This c omp letes the hard ware installation using an ADU. The following tasks in Chap ter 9, ‘‘Initial Network Ad ministration and Ac c ep tanc e Tests’’, need to b e c omp leted before the installation is c omp lete: nTask 9: Ad minister Remote System(s) on the Loc al DEFINITY AUDIX Sys t e m. nTask 10: Ad minister the DEFINITY AUDIX on the Remote Mac hine(s) nTask 11: Test the Connec tion to Eac h Remote System Complete Chap ter 9.
DEFINITY AUDIX System Digital Networking 585-300-534 Issue 2 May 1999 Hardware Installation for DCP Mode 2 8-5 Hardware Installation Using an ADU 8 Figure 8-2. ADU in a DCP Mode 2 Modem/Data Module Arrangement DEFINITY AUDIXTN726B circuit pack TN747 circuit pack To public network PBX Switched Cross connect103A or wall jack ADU (Z3A-2) 3800 series modem D8W-87 M8J-82 H-600-258, Group 1 null modem cable (male-female) TN742 or TN746B analog circuit pack Switched Cross connect103A or wall jack2/4 wire line cord
DEFINITY AUDIX System Digital Networking 585-300-534 Issue 2 May 1999 Hardware Installation for DCP Mode 2 8-6 Configuring the Paradyne Comsphere 3810/3820 Series Modems using the 8 Configuring the Paradyne Comsphere 3810/3820 Series Modems using the Diagnostic Control Panel The Diag nostic Control Panel’s (DCP) liq uid c rystal d isp lay (LCD) c onsists of two 16-c harac ter lines, whic h d isp lay mod em status, c ontrol func tions, and c onfig uration op tions. To c onfig ure the Comsp here 3810/3820 series mod ems for digital networking, you must program the modem using the DCP. To c onfig ure the Comsp here mod em to work with DEFINITY AUDIX d ig ital networking , p erform the following step s: 1. On the DCP, p ress the key until Configure c omes into view. 2. Press the func tion key d irec tly und er Config ure to selec t the Config ure menu. The LCD disp lays Ld EditArea frm . 3. Press the key until Factory c omes into view. 4. Press the func tion key d irec tly und er Fac tory to d isp lay the fac tory p reset configurations. 5. Press the func tion key d irec tly und er Async Dial . 6. The LCD disp lays the following lines: Choose Func tion Edit Save 7. Press the func tion key d irec tly und er the Ed it op tion. The LCD disp lays the following lines: Edit StrapGroup DTE_Interface The DTE_Interfac e sub menu op tion c ontains setting s for the EIA-232-D (ITU V.24) and for the async hronous c harac ter formation information used to maintain the c onnec tion and to transmit d ata b etween the mod em and the 7400A or ADU. 8. Press the func tion key d irec tly und er the DTE_Interfac e submenu. The LCD displays the following lines: Async/Sync Mode Nxt Async 9. The Async mod e is the c orrec t setting . Press the func tion key direc tly und er Nxt to retain this setting . The LCD disp lays the following lines: Async DTE Rate 19200
DEFINITY AUDIX System Digital Networking 585-300-534 Issue 2 May 1999 Hardware Installation for DCP Mode 2 8-7 Configuring the Paradyne Comsphere 3810/3820 Series Modems using the 8 10. If 19200 b p s is the setting for DCP Mod e 2 d ig ital networking , press the func tion key d irec tly und er the Nxt op tion. If 9600 b ps is the d ig ital networking sp eed : 1. Press the key until 9600 d isp lays on the LCD. 2. Press the func tion key d irec tly und er the 9600 op tion. 3. Press the func tion key d irec tly und er Nxt to save this setting . The LCD displays the following lines: Asyn #Data Bits Nxt 8 11. Continue to c onfig ure the DTE_Interfac e op tions b y using the setting s described in Tab le 8-1 , Parad yne Comsp here 3810p lus/3820p lus/3910 Mod em Settings, for the Comsp here 3810plus/3820p lus/3910 mod ems and Ta b l e 8 - 2 , Paradyne Comsp here 3810/3820 Mod em Setting s, for the Comsp here 3810/3820 mod ems. NOTE: Some of the setting s listed in Ta b l e 8 - 1 and Tab le 8-2 may not b e p resent in your mod em, or there may b e setting s that are not listed in the tab les. Parad yne p eriod ic ally up d ates their modem firmware with new op tions so your firmware may d iffer from the firmware that is depicted in Table 8-1 and Table 8-2. All op tions and setting s that are req uired for DEFINITY AUDIX d ig ital networking are p resent in all firmware releases. Use the following p roc ed ure: nIf the setting is not in b old fac e typ e, press the func tion key d irec tly und er Nxt to c ontinue to the next menu item. nFor the b old fac e items, use the following p roc ed ure: 1. Press the key until the option d isp lays on the LCD. 2. Press the func tion key d irec tly und er the option. 3. Press the func tion key d irec tly und er Nxt to save this setting . nThe last op tion in the DTE_Interfac e Menu has an End func tion instead of the Nxt func tion. Press the func tion key d irec tly und er End . This returns you to the Ed it Strap Group menu.
DEFINITY AUDIX System Digital Networking 585-300-534 Issue 2 May 1999 Hardware Installation for DCP Mode 2 8-8 Configuring the Paradyne Comsphere 3810/3820 Series Modems using the 8 12. At the Edit StrapGroup menu, p ress the key to move to the DTE_Dialer sub menu. Press the func tion key d irec tly und er DTE_Dialer, and c onfig ure the op tions as shown in Ta b l e 8 - 1 , Parad yne Comsp here 3810p lus/3820p lus/3910 Mod em Setting s, for the Comsp here 3810p lus/3820p lus/3910 mod ems and Tab le 8-2 , Paradyne Comsp here 3810/3820 Mod em Setting s, for the Comsp here 3810/3820 modems. Use the following p roc ed ure: nIf the setting is not in b old fac e typ e, press the Nxt func tion key to c ontinue to the next menu item. nFor the b old fac e items, use the following p roc ed ure: 1. Press the key until the option d isp lays on the LCD. 2. Press the func tion key d irec tly und er the option. 3. Press the func tion key d irec tly und er Nxt to save this setting . For the option AT Escape Char und er the DTE_Dialer sub menu, use the following p roc ed ure to c hang e the op tion to 128 for examp le. The and keys move the c ursor to the rig ht or left. Th e key inc reases the d ig it. 1. The c ursor is und er the first d ig it. Press the key until 1 displays. 2. Press the key to move the c ursor to the sec ond d ig it. 3. Press the key until 2 d isp lays. 4. Press the key to move the c ursor to the third d ig it. 5. Press the key until 8 d isp lays. 6. Press the func tion key d irec tly und er ASCI to save the numb er. 7. Press the func tion key und er Nxt to move to the next option. nThe last op tion in the menu has an End func tion instead of the Nxt func tion. Press the func tion key d irec tly und er End. This returns you to the Ed it Strap Group menu. F2 F2 F2 F2
DEFINITY AUDIX System Digital Networking 585-300-534 Issue 2 May 1999 Hardware Installation for DCP Mode 2 8-9 Configuring the Paradyne Comsphere 3810/3820 Series Modems using the 8 13. After setting the op tions for the DTE_Dialer sub menu, c ontinue to set the op tions for the Line_Dialer, Dial Line, V42/MNP/Buffer, and Test and Misc sub menus. At the Edit StrapGroup menu, p ress the key to move to the d esired sub menu. Press the func tion key d irec tly und er the d isp layed sub menu, and c onfig ure the op tions as shown in Ta b l e 8 - 1 , Parad yne Comsp here 3810p lus/3820p lus/3910 Mod em Setting s, for the Comsp here 3810p lus/3820p lus/3910 mod ems andTa b l e 8 - 2 , Paradyne Comsphere 3810/3820 Mod em Setting s, for the Comsp here 3810/3820 modems. Use the following p roc ed ure: nIf the setting is not in b old fac e typ e, press the Nxt func tion key to c ontinue to the next menu item. nFor the b old fac e items, use the following p roc ed ure: 1. Press the key until the option d isp lays on the LCD. 2. Press the func tion key d irec tly und er the option. 3. Press the func tion key d irec tly und er Nxt to save this setting . nThe last op tion in the menu has an End func tion instead of the Nxt func tion. Press the func tion key d irec tly und er End. This returns you to the Ed it Strap Group menu. 14. When you have set all op tions in all the sub menus and the LCD d isp lay shows the Ed it Strap Group menu, p ress the left key. The LCD d isp lays the following lines: Choose Function Edit Save Press the func tion key d irec tly und er the Save op tion. The LCD d isp lays the following lines: Sav EditArea to Active(Saved) 15. Press the func tion key d irec tly under the Ac tive(Saved ) op tion. This saves the setting s and c omp letes the c onfiguration of the mod em. The LCD d isp lays Command Complete . 16. Press the key to return the mod em to the normal op erating p osition. For examp le: Idle: 9600 Call_Setup To Chang e any setting s at a later d ate, rep eat the ab ove p roc ed ure. In step 3, selec t Ac tiv(Op erating ) instead of Fac tory.
DEFINITY AUDIX System Digital Networking 585-300-534 Issue 2 May 1999 Hardware Installation for DCP Mode 2 8-10 Paradyne Comsphere 3810plus/3820plus/3910 Front Panel Settings 8 Paradyne Comsphere 3810plus/3820plus/3910 Front Panel Settings The following tab le shows the front p anel setting s for the Parad yne Comsp here 3810p lus, 3820p lus, and 3910 mod ems. Table 8-1. Paradyne Comsphere 3810plus/3820plus/3910 Modem Settings (Bold Setting s are Chang es from Fac tory Setting s) DTE_Interface Setting Notes Async/Sync Mod e Async Async DTE Rate 19200 or 9600 AT c ommand s41= 20 AT c ommand s41= 3 Asyn #Data Bits 8 Asyn Parity Bit None Asyn #Stop Bits 1 DTR Ac tionStndrd_RS232 AT command &d 2 DSR ControlWinkWhenDisc AT command &s2 RTS Ac tion Ig nore CTS Control Forc ed _On RTS/ C TS D e la y 0 m s e c LSD ControlWinkWhenDisc AT command &c 2 TX Cloc k Sourc e Internal CT111_Rate Cntl Disab le DTE_Rate= VF Disab le DTE_Dialer Setting Notes DTE Dialer Typ e AT AT Esc ap e Char128 ASCI AT c ommand s2= 128 Escape GuardTim 1 sec BreakForc eEsc ap Disab le CommandCharEc ho Enab le Carriag eRtnChar 013 ASCI Bac ksp ac e Char 008 ASCI