    Have a look at the manual Lucent Technologies Definity Audix System Digital Networking Guide online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 413 Lucent Technologies manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.

    							DEFINITY AUDIX System Digital Networking  585-300-534  Issue 2
    May 1999
    DCP Mode 2 — 9600 or 19,200 bps 
    4-7 DEFINITY AUDIX Modem/Data Module Arrangements 
    4
    DEFINITY AUDIX to DEFINITY AUDIX 
    Multistag e d ialing  from one DEFINITY AUDIX system to another DEFINITY AUDIX 
    system p ermits a d ig ital networking  p ort to p lac e a c all in three stag es.
    1. Call a DCP-to-mod em c onversion resourc e.
    2. Initiate a sec ond  c all off p remises over analog  fac ilities to a remote 
    mod em.
    3. Estab lish the final c onnec tion to the remote d ig ital networking port.
    All three stag es must b e inc lud ed  in the Dial String  entered  on the Mac hine 
    Profile sc reen for c alling  the other system.
    DEFINITY AUDIX to Intuity AUDIX or 
    AUDIX R1
    Multistag e d ialing  from a DEFINITY AUDIX system to an Intuity AUDIX system or 
    an AUDIX R1 system permits a d ig ital networking port to p lac e a c all in two 
    stag es.
    1. Call a DCP-to-mod em c onversion resourc e.
    2. Initiate a sec ond  c all off p remises over analog  fac ilities to a remote 
    modem or modem pool.
    These two stages must be inc luded in the Dial String entered on the DEFINITY 
    AUDIX Mac hine Profile sc reen for c alling  the Intuity AUDIX system or AUDIX R1 
    system.
    Intuity AUDIX or AUDIX R1 to DEFINITY 
    AUDIX 
    Multistag e d ialing  from an Intuity AUDIX system or an AUDIX R1 system to a 
    DEFINITY AUDIX system p ermits a dig ital networking  p ort to p lac e a c all in two 
    stag es.
    1. Initiate a c all off p remises over analog  fac ilities to a remote mod em.
    2. Estab lish the final c onnec tion to the remote d ig ital networking port.
    The Intuity AUDIX or AUDIX R1 dial string  must inc lud e these two stag es for 
    c alling  the DEFINITY AUDIX system.
    Following  is an examp le Dial String  for an Intuity AUDIX or AUDIX R1 DCP Mod e 
    2 networking  c all to a DEFINITY AUDIX networking  p ort:
    ATDT9,1303,5552345” W” ” B” 51234
    nATDT – Attention c ommand  of the modem
    n9,1303,5552345 – Long  d istanc e numb er of the remote DEFINITY AUDIX 
    modem or modem hunt group 
    						
    							DEFINITY AUDIX System Digital Networking  585-300-534  Issue 2
    May 1999
    DCP Mode 2 — 9600 or 19,200 bps 
    4-8 DEFINITY AUDIX Modem/Data Module Arrangements 
    4
    n“ W”  – Wait for mod ems to hand shake
    n“ B”  – Send  Break c ommand  to ac tivate the DIAL: p romp t on the DCP d ata 
    mod ule
    n51234 – Cause the DCP d ata mod ule to d ial the DEFINITY AUDIX 
    networking  p ort or hunt g roup .
    The following fig ure shows the three stag es of multistag e d ialing : 
    .
    Figure 4-5. Multistage Dialing Between DEFINITY AUDIX Systems
    DEFINITY
    AUDIX
    Analog
    portAnalog
    trunk
    DCP
    port
    7400A
    Modem
    PBX
    Analog
    T/R DCP
    DEFINITY
    AUDIX
    Analog
    port EIA
    portAnalog
    trunk
    ADU
    Modem
    PBX
    Analog
    T/R x4993
    Call #3Call #1
    Call #2 Call #2
    STAGE 1
    STAGE 3 STAGE 2CCMS keyboard dial
    Dial string:
    Hayes modem dial
    Dial string: Dial string:
    7400A keyboard dial
    Dial string: (wait then break)x71044993
    9=19086587100
    4993WATDT919086587100WB7104
    7104 Multistage Dial Information: 
    						
    							DEFINITY AUDIX System Digital Networking  585-300-534  Issue 2
    May 1999
    DCP Mode 2 — 9600 or 19,200 bps 
    4-9 DEFINITY AUDIX Modem/Data Module Arrangements 
    4
    In the d ial string  shown in the ab ove fig ure, the end  of the first stag e of d ialing  is 
    indic ated  b y the W
     c ommand  whic h tells the DEFINITY AUDIX system to wait for 
    a c onnec tion to b e estab lished  to the next element. Calling  via a mod em/data 
    mod ule arrang ement (shown in the ab ove fig ure) involves the following stag es:
    nStage 1
    . The DEFINITY AUDIX system send s the d ial string  4993 to 
    estab lish a c onnec tion with the d ig ital sid e of a mod em/d ata mod ule 
    arrang ement at a c ommon DCP Mod e 2 d ata rate (9600 or 19200 b p s). In 
    the ab ove fig ure, this c onnec tion is from the DEFINITY AUDIX system to 
    the ADU. (An Intuity AUDIX system or an AUDIX R1 system to a DEFINITY 
    AUDIX system d oes not require this stag e b ut may req uire c ommas for 
    p auses.)
    nStage 2
    . The DEFINITY AUDIX system then send s the Hayes d ialing  
    commands (in the above figure, this string is 
    ATDT 9=19086587100). The 
    loc al mod em g oes off-hook and  initiates a c all to the remote end p oint. The 
    mod em at the remote end p oint answers the c all.
    nStage 3
    . The third  stag e of the d ial string  tells the remote d ata mod ule to 
    g o off hook (ind ic ated  b y the W
     [wait] and B
     [ b reak]  c ommand ) and  d ial 
    the digital networking port hunt group 
    7104. The c all c omp letes to the 
    remote DEFINITY AUDIX system. (A DEFINITY AUDIX system to an Intuity 
    AUDIX system or an AUDIX R1 system d oes not req uire this stag e b ut may 
    req uire c ommas for pauses.)
    The following fig ure shows the d ial string  from the ab ove fig ure entered  on p ag e 
    2 of the Mac hine Profile sc reen:
    Figure 4-6. Multistage Dial String on Machine Profile Screen 
    						
    							DEFINITY AUDIX System Digital Networking  585-300-534  Issue 2
    May 1999
    DCP Mode 2 — 9600 or 19,200 bps 
    4-10 Switch Hardware Requirements for DCP Mode 2 
    4
    Switch Hardware Requirements for 
    DCP Mode 2
    DCP Mod e 2 has the following  hardware req uirements for the System 75 
    R1V3 2.2 or later, DEFINITY G1, DEFINITY G3i, and  DEFINITY G3r:
    nTN754 DCP p ort (one p ort for eac h 7400A d ata mod ule)
    nTN726 EIA p ort (one p ort for eac h ADU)
    nTN742 analog  p ort/TN746B analog  line (one p ort or one line for eac h 
    mod em)
    nSystem 75
    — The switc h must b e R1V3 2.2 or later.
    — All tone d etec tors must b e TN748C (V4 or later).
    nDEFINITY Generic  1 and  Generic  3
    — All tone d etec tors must b e TN748C (V4 or later).
    — The tone c loc ks must b e TN786 and  TN741.
    AUDIX R1 Requirements 
    AUDIX R1V5 and  later systems req uire a TN539B network c ard to d o two-stag e 
    d ialing  when networking  with a DEFINITY AUDIX system using  DCP Mod e 2.
    Switch Administration Requirements 
    for DCP Mode 2
    DCP Mod e 2 req uires the following  ad d itional switc h ad ministration. Refer to 
    Chapter 9, ‘‘Initial Network Administration and  Ac c eptanc e Tests’’
    , for 
    ad ministration p roc ed ures.
    7400A Data Module
    Ad d  a d ata extension for eac h 7400A d ata mod ule and  set it up as a PDM.
    Asynchronous Data Unit (ADU)
    Ad d  a d ata extension for eac h ADU and set it up  as a data line.
    Modem
    Ad d  a station extension for eac h mod em and  set it up  as a 2500. 
    						
    							DEFINITY AUDIX System Digital Networking  585-300-534  Issue 2
    May 1999
    DCP Mode 2 — 9600 or 19,200 bps 
    4-11 Switch Administration Requirements for DCP Mode 2 
    4
    Hunt Groups
    If there are two d ig ital networking  p orts, set up  a hunt g roup  for the d ig ital 
    networking  p orts and , op tionally, for p airs of d ata mod ules, ADUs, and mod ems.
    Digital Networking Ports
    If there are two digital networking ports, set up a hunt group that c ontains the two 
    p orts for inc oming  c alls. 
    Additional Hunt Groups
    If there is hard ware for two DCP Mod e 2 networking  p orts for DEFINITY AUDIX 
    d ig ital networking , set up  the following  ad d itional hunt group s on the switc h.
    nset up  eac h p air of d ata module p orts in a hunt g roup  or set up  eac h p air 
    of ADU p orts in a hunt g roup
    nset up  eac h p air of mod em p orts in a hunt g roup
    Fi g u re  4 - 7
    , Switc h Hunt Group s for Data Mod ule, ADU, and  Mod em Ports (2 of 2), 
    d ep ic ts the hunt g roup arrang ements for DCP Mod e 2. In this fig ure, DEFINITY 
    AUDIX A shows a hunt g roup  for the p air of networking p orts, a hunt g roup  for the 
    p air of 7400A d ata mod ule ports, and  a hunt group  for the pair of mod em p orts. 
    DEFINITY AUDIX B shows a hunt group  for the p air of networking  p orts, a hunt 
    group for the pair of ADU ports, and a hunt group for the pair of modem ports. 
    The d ial strings entered  on the remote Mac hine Profile sc reen then use these 
    hunt g roup  numb ers to p lac e a c all throug h the switc h to the remote DEFINITY 
    AUDIX system. 
    DEFINITY AUDIX A uses multistag e d ialing  to p lac e a c all to DEFINITY AUDIX B.
    nStag e 1 p lac es a c all to the 7400A d ata mod ule using  the hunt g roup  11 
    extension numb er 40020.
    nStag e 2 p lac es a c all to mod em hunt g roup  22 on PBX 2 using  the numb er 
    20010.
    nStag e 3 p lac es a c all to the hunt g roup  extension of the DEFINITY AUDIX 
    networking  p orts on PBX 2 using  extension numb er 20000. 
    						
    							DEFINITY AUDIX System Digital Networking  585-300-534  Issue 2
    May 1999
    DCP Mode 2 — 9600 or 19,200 bps 
    4-12 Switch Administration Requirements for DCP Mode 2 
    4
    DEFINITY
    AUDIX A
    DEFINITY
    AUDIX B TN754
    port
    TN726
    port TN754
    port
    TN726
    port TN746B
    port
    TN746B
    port TN746B
    port
    TN746B
    portAnalog
    trunk
    Analog
    trunk
    7400A 7400A
    ADU ADU
    Modem
    Modem Modem
    ModemPBX 1
    PBX 2 554-
    nnnn
    552-nnnn
    Hunt group 11
    Hunt group 21 Hunt group 12
    Hunt group 22
    ext. 40021
    ext. 20021 ext. 40022
    ext. 20022 ext. 40011
    ext. 20011 ext. 40012
    ext. 20012
    Switched
    Switched Switched
    Switched
    Hunt group 11(data
    module ports)
    Group extension 40020
    Data module extensions
    40021, 40022
    Hunt group 21 (ADU
    ports)
    Group extension 20020
    ADU extensions 20021,
    20022Hunt group 10
    (networking ports)
    Group extension 40000
    Network port extensions
    40001, 40002
    Hunt group 20
    (networking ports)
    Group extension 20000
    Network port extensions
    20001, 20002 Hunt group 12 (modem
    ports)
    Group extension 40010
    Modem extensions
    40011, 40012
    Hunt group 22 (modem
    ports)
    Group extension 20010
    Modem extensions
    20011, 20012
    Public/private
    interlocation facilities Analog
    data call 
    						
    							DEFINITY AUDIX System Digital Networking  585-300-534  Issue 2
    May 1999
    DCP Mode 2 — 9600 or 19,200 bps 
    4-13 Switch Administration Requirements for DCP Mode 2 
    4
    Figure 4-7. Switch Hunt Groups for Data Module, ADU, and Modem Ports (2 of 2)
    40020 W ATDT 9,5520010 W B 20000
    20020 W ATDT 9,5540010 W B 40000 Call 7400A
    hunt group
    Call ADU
    hunt groupWait
    WaitTell modem to call
    modem hunt group
    on PBX 2 (Hunt
    Group 22)
    Tell modem to call
    modem hunt group
    on PBX 1 (Hunt
    Group 12)Wait then send
    break to ADU
    connected to
    modem on PBX 2
    Wait then send
    break to 7400A
    connected to
    modem on PBX 1Dial the hunt group
    extension of the
    DEFINITY AUDIX
    networking ports on
    PBX 2
    Dial the hunt group
    extension of the
    DEFINITY AUDIX
    networking ports on
    PBX 1
    Sample dial string
    DEFINITY AUDIX A to DEFINITY AUDIX B
    Dial 9 for outside trunk
    Sample dial string
    DEFINITY AUDIX B to DEFINITY AUDIX A
    Dial 9 for outside trunk 
    						
    							DEFINITY AUDIX System Digital Networking  585-300-534  Issue 2
    May 1999
    DCP Mode 2 — 9600 or 19,200 bps 
    4-14 Switch Administration Requirements for DCP Mode 2 
    4
    The following fig ures show samp le switc h Hunt Group  sc reens for DEFINITY 
    AUDIX A.
    Figure 4-8. Digital Networking Ports Switch Hunt Group – Screen 1 
    						
    							DEFINITY AUDIX System Digital Networking  585-300-534  Issue 2
    May 1999
    DCP Mode 2 — 9600 or 19,200 bps 
    4-15 Switch Administration Requirements for DCP Mode 2 
    4
    Figure 4-9. Digital Networking Ports Switch Hunt Group – Group Member 
    Assignments
    Figure 4-10. Data Module Switch Hunt Group – Screen 1 
    						
    							DEFINITY AUDIX System Digital Networking  585-300-534  Issue 2
    May 1999
    DCP Mode 2 — 9600 or 19,200 bps 
    4-16 Switch Administration Requirements for DCP Mode 2 
    4
    Figure 4-11. Data Module Switch Hunt Group – Group Member Assignments
    Figure 4-12. Modem Switch Hunt Group – Screen 1 
    						