CHAPTER 4 NDA-24282 Pag e 5 2 Revision 1.0 PH-PC22 (EAPI) SWITCH NAMESWITCH NO. SETTINGSTANDARD SETTINGMEANING SW01 (for Port 0) SW11 (for Port 1) (When using AC D-M IS Interface Port)1 2 3 4ON×Sets the non-protocol RS-232C port stop bit length to 1 bit. OFFSets the non-protocol RS-232C port stop bit length to 2 bit. 5ON×Sets the non-protocol RS-232C port data length to 7 bit. OFFSets the non-protocol RS-232C port data length to 8 bit. 6 7 8ONSets the polarity of non-protocol RS-232C PB signal to Not Provided. OFF×Sets the polarity of non-protocol RS-232C PB signal to +, or sets PB signal to Provided. SW01-1 SW11-1SW01-2 SW11-2SW01-3 SW11-3NON-PROTOCOL RS-232C PORT DATA SPEED SETTING ON ON ON 300 bps ON ON OFF 600 bps ON OFF ON 1200 bps ON OFF OFF 2400 bps OFF ON ON 4800 bps OFF ON OFF 9600 bps OFF OFF ON 19200 bps SW01-6 SW11-6SW01-7 SW11-7NON-PROTOCOL RS-232C PORT PARITY BIT SETTING ON ON ODD Parity Check ON OFF EVEN Parity Check (standard setting) OFF OFF No Parity Check is to be made
NDA-24282 CHAPTER 4 Page 53 Revision 1.0 PH-PC22 (EAPI) SWITCH SETTING SHEET MODULE SLOT NO.SWITCH NAMESWITCH SHAPE REMARKS LCMA 02 03 04MB UP: Circuit card make busy MBR DOWN: Circuit card make idle LPRJ-A 00 01 02SW0 SW01 9600 bps Port 0, 1 Stop 7 Even SW11 9600 bps Port 1, 1 Stop 7 Even DOWN DOWN ON 12345678 ON 12345678 ON 12345678
CHAPTER 4 NDA-24282 Pag e 5 4 Revision 1.0 PH-PC27 (EAPI) PH-PC27 (EAPI) 1. Function This circuit card is an I/O system functions integrated card to be used in the ACD Circuit Card Type System. This card supports the following functions. (a) APINT Function: For processor communications between the CPU of the System and ACDP card, this circuit card provides FIFO for mutual I/O bus connections. (b) IOC Function: For ACD-MIS connection, this circuit card provides a serial interface which conforms with RS-232C (three I/O ports). 2. Mounting Location/Condition The mounting locations of this circuit card and the conditions related to mounting are shown below. GATE CPU MEMECPYGA TE CPU MEMMISC EAPI ACDPMISC 8-bit I/O Bus RS-232C Extended 8-bit I/O Bus TSW, INT 8-bit I/O Bus 32-bit MEM Bus Position within the system 00 01 02 03 04 05 06 07 08 09 10 11 12 13 14 15 16 17 18 19 20 21 22 23 Mounting Module LCMA PH-PC27 PH-PC27 PH-PC27 Note Note:This circuit card is mounted in any one of Slot No. 02~04.
NDA-24282 CHAPTER 4 Page 55 Revision 1.0 PH-PC27 (EAPI) 3. Face Layout of Lamps, Switches, and Connectors The face layout of lamps, switches, and connectors of this circuit card is shown below. 00 01 02 03 04 Mounting Module LPRJ-A PH-PC27 PH-PC27 PH-PC27 Note CPRAC-0 CPRAC-1 Note:This circuit card is mounted in any one of Slot No. 00~02. IOC OPE CLKALM OPE/MB MB SW10 SW12 SW11 MBR SW0to CP-53 to CP-53 AP-1 AP-0
CHAPTER 4 NDA-24282 Pag e 5 6 Revision 1.0 PH-PC27 (EAPI) 4. Lamp Indications The contents of lamp indications of this circuit card are shown in the table below. 5. Switch Settings Standard settings of various switches on this circuit card are shown in the table below. LAMP NAME COLOR STATE OPE/MB Green Remains lit while this circuit card is operating. IOCOPE Red Remains lit while the non-protocol/RS-232C Port Controller is operating normally. CLKALM Red Lights when a clock failure has occurred. Note:The PH-PC27 is a three port EAPI card. SWITCH NAMESWITCH NO. SETTINGSTANDARD SETTINGMEANING MBUP Circuit card make busy. DOWN Circuit card make idle. MBRUPRequests the software to place the ACD-MIS Interface Port Controller into make-busy state. DOWNCancels the request to place the ACD-MIS Interface Port Controller into make-busy state. (Circuit card operating state) SW01OFF× 2OFF× 3OFF× 4OFF× 5OFF× 6ON× 7OFF× 8ON× Fixed
NDA-24282 CHAPTER 4 Page 57 Revision 1.0 PH-PC27 (EAPI) Note: Ports 0, 1 and 2 translate to MIS ports 1, 2 and 3. SWITCH NAMESWITCH NO. SETTINGSTANDARD SETTINGMEANING SW10 (for Port 0) SW11 (for Port 1) SW12 (for Port 2)1 2 3 MIS Port Interface 4ON×Sets the non-protocol RS-232C port stop bit length to 1 bit. OFFSets the non-protocol RS-232C port stop bit length to 2 bit. 5ON×Sets the non-protocol RS-232C port data length to 7 bit. OFFSets the non-protocol RS-232C port data length to 8 bit. 6 7 8ONSets the polarity of non-protocol RS-232C PB signal to Not Provided. OFF×Sets the polarity of non-protocol RS-232C PB signal to +, or sets PB signal to Provided. SW01-1 SW11-1SW01-2 SW11-2SW01-3 SW11-3NON-PROTOCOL RS-232C PORT DATA SPEED SETTING ON ON ON 300 bps ON ON OFF 600 bps ON OFF ON 1200 bps ON OFF OFF 2400 bps OFF ON ON 4800 bps OFF ON OFF 9600 bps OFF OFF ON 19200 bps SW01-6 SW11-6SW01-7 SW11-7NON-PROTOCOL RS-232C PORT PARITY BIT SETTING ON ON ODD Parity Check ON OFF EVEN Parity Check (standard setting) OFF OFF No Parity Check is to be made
CHAPTER 4 NDA-24282 Pag e 5 8 Revision 1.0 PH-PC27 (EAPI) SWITCH SETTING SHEET MODULE SLOT NO.SWITCH NAMESWITCH SHAPE REMARKS LCMA 02 03 04MB UP: Circuit card make busy. MBR DOWN: Circuit card make idle. LPRJ-A 00 01 02SW0 SW10 2, 4, 5, 6 ON only SW11 2, 4, 5, 6 ON only SW12 2, 4, 5, 6 ON only DOWN DOWN ON 12345678 ON 12345678 ON 12345678 ON 12345678
NDA-24282 CHAPTER 4 Page 59 Revision 1.0 PA-AL16 (ALMC) PA-AL16 (ALMC) 1. Function This circuit card collects fault information and manages a dual-configuration system of the ACD Module Type System. The card displays the collected fault information on the TOPU. Besides, the card provides the functions for data communication between two ACDPs in the dual system configuration. 2. Mounting Location/Condition The mounting location of this circuit card and the condition related to mounting are shown below. When ACDP is provided by single system configuration in the IMG (IMX), this circuit card is to be mounted in its mounting slot only when the APMA is installed externally. CPU APINTAPINT CPUCPU COPYCOPY CRAMCRAM IOC ACD-MIS ALMC RS-232C (Non-protocol) IMX ACD system (Module Type) I/O LOCAL BUS (ACDP) (ACDP) APM-A\E Position within the System 00 01 02 03 04 05 06 07 08 09 10 11 12 13 14 15 16 17 18 19 20 21 22 23 Mounting Module APM-A\E PA-AL16
CHAPTER 4 NDA-24282 Pag e 6 0 Revision 1.0 PA-AL16 (ALMC) 3. Face layout of Lamps, Switches, and Connectors The face layout of lamps, switches, and connectors of this circuit card is shown below. MBR SW1 EMA SUP MG SW5 SW4 SW6 SW0 SW2 (SW3)CPUSEL
NDA-24282 CHAPTER 4 Page 61 Revision 1.0 PA-AL16 (ALMC) 4. Switch Settings Standard settings of various switches on this circuit card are shown in the table below. Note 1:For IMG (IMX) (ICS), IMGx, IMGxh Note 7:For MMG (ICS), UMG (ICS), UMGx SWITCH NAMESWITCH NO.SETTINGSTANDARD SETTINGMEANING MBUP Circuit card make busy. DOWNCircuit card make idle. EMASUP UP×Fixed DOWN CPUSEL UP MIDDLEFor ACDP Dual System Configuration DOWNFor ACDP Single System Configuration MG (SW3) 0Single CPU System Note 1 9Multi CPU System Note 2 SW0 1 OFF×Fixed 2OFF×Fixed 3OFF×Fixed 4ON×Fixed SW1 1 OFF×Fixed 2ON×Fixed 3OFF×Fixed 4ON×Fixed SWITCH NAMESWITCH NO.SETTINGSTANDARD SETTINGMEANING SW21OFF×Fixed 2ON×Fixed ON ON ON ON1234 ON1234 12ON