Home > NEC > Communications System > NEC Neax 2400 Imx Callcenterworx Enterprise Acd System Manual

NEC Neax 2400 Imx Callcenterworx Enterprise Acd System Manual

    Download as PDF Print this page Share this page

    Have a look at the manual NEC Neax 2400 Imx Callcenterworx Enterprise Acd System Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 1168 NEC manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.

    Page
    of 485
    							CHAPTER 3 NDA-24282
    Pag e 2 2
    Revision 1.0
    INSTALLATION
    Figure 3-4 shows the cable connection between the Agent Position and the NEAX2400 IMX.
    Figure 3-4   Connection of ACD Agent Position
    NAP-200-101
    Sheet 1/3
    Installation  of ACD  Agent Position 
    Note 2:For more details of connector lead accommodation, see “Circuit Card Manual”.
    PIMMDF
    Installation Cable
    MDF Max. 850m (0.5φ)
    16ELC Camp
    Connector Leads (example)Modular Rosette
    Modular Jack
    Note 1
    LTNo.1
    No.15
    Dterm No.0
    (Dterm Series III/Series E)
    PA-16ELCJ
    26
    27
    28
    29
    30
    31
    32
    33
    34
    35
    36
    37
    38
    39
    40
    41
    42
    43
    44
    45
    46
    47
    48
    49
    50 1
     2
     3
     4
     5
     6
     7
     8
     9
    10
    11
    12
    13
    14
    15
    16
    17
    18
    19
    20
    21
    22
    23
    24
    25 B0
    B1
    B2
    B3
    B4
    B5
    B6
    B7
    B8
    B9
    B10
    B11
    B12
    B13
    B14
    B15A0
    A1
    A2
    A3
    A4
    A5
    A6
    A7
    A8
    A9
    A10
    A11
    A12
    A13
    A14
    A15
    Agent Position1
    2
    34
    No.0
    No.1
    No.2
    No.3
    No.4
    No.5
    No.6
    No.7
    No.8
    No.9
    No.10
    No.11
    No.12
    No.13
    No.14
    No.15
    A0 B0
    1
    23
    4
    PA-16ELCJ
    Note 1:Connector leads (A0 and B0)
    may be connected with Modu-
    lar Rosette. 
    						
    							NDA-24282 CHAPTER 3
    Page 23
    Revision 1.0
    INSTALLATION
     Attach the provided key pad/labels to identify the names of the keys. For the function key data assignments,
    refer to the AKYD command in Chapter 7.
    (1) D
    term Series III
    Figure 3-5   Key Pads on ACD Agent Position Keyboard ( Dterm Series III)
    NAP-200-101
    Sheet 2/3
    Installation  of ACD  Agent Position 
    HOLD XFR CONF WORK
    *0
    #TALLY
    8 795 462 13LOGONBREAK
    RLS CW AUTO/MAN ASSIST EMER TRKTRBL RECALL
    ACD CALL LINE FNC HAND/HEAD MIC SPKR 
    						
    							CHAPTER 3 NDA-24282
    Pag e 2 4
    Revision 1.0
    INSTALLATION
    (2) Dterm 
    Series E
    Figure 3-6   Key Pads on ACD Agent Position Keyboard ( Dterm Series E)
    NAP-200-101
    Sheet 3/3
    Installation  of ACD  Agent Position 
    12
    3
    45 6
    789
    0# 
    CW
    ACDCALL LINE TRKTRBL RECALL
    FUNC HAND/HEAD MIC SPKR
    RLS
    BREAK
    LOGON
    TALLY
    WORK CONF XFR HOLD
    FLEX KEYASSIST EMER AUTO/MAN 
    						
    							NDA-24282 CHAPTER 3
    Page 25
    Revision 1.0
    INSTALLATION
    Figure 3-7 shows the cable connection between the Supervisory Position and the NEAX2400 IMX.
    Figure 3-7   Connection of ACD Supervisory Position
    NAP-200-102
    Sheet 1/3
    Installation of ACD Supervisory Position 
    Note 2:For more details of connector lead accommodation, see “Circuit Card Manual”.
    LTNo.1
    No.15
    26
    27
    28
    29
    30
    31
    32
    33
    34
    35
    36
    37
    38
    39
    40
    41
    42
    43
    44
    45
    46
    47
    48
    49
    50 1
     2
     3
     4
     5
     6
     7
     8
     9
    10
    11
    12
    13
    14
    15
    16
    17
    18
    19
    20
    21
    22
    23
    24
    25 B0
    B1
    B2
    B3
    B4
    B5
    B6
    B7
    B8
    B9
    B10
    B11
    B12
    B13
    B14
    B15A0
    A1
    A2
    A3
    A4
    A5
    A6
    A7
    A8
    A9
    A10
    A11
    A12
    A13
    A14
    A15
    Supervisory Position
    1
    2
    34
    No.0
    No.1
    No.2
    No.3
    No.4
    No.5
    No.6
    No.7
    A0 B0
    MDF MDF
    PIM
    Installation Cable
    Max. 850m (0.5 f )Dterm No. 0
    (Dterm Series III/Series E)
    No.8
    No.9
    No.10
    No.11
    No.12
    No.13
    No.14
    No.15
    16ELC Camp
    Connector Leads (example)Modular Rosette
    Modular Jack
    1
    23
    4
    Note 1
    PA-16ELCJPA-16ELCJ
    Note 1:Connector leads (A0,
    B0) may be connected
    with Modular Rosette. 
    						
    							CHAPTER 3 NDA-24282
    Pag e 2 6
    Revision 1.0
    INSTALLATION
     Attach the provided key pad/labels to identify the names of the keys. For the function key data assignments,
    refer to the AKYD command in Chapter 7.
    (1) D
    term Series III
    Figure 3-8   Key Pads on Supervisory Position Keyboard (Dterm Series III)
    NAP-200-102
    Sheet 2/3
    Installation of ACD Supervisory Position
    CW AUTO/MAN TRKTRBL RECALL
    ACD CALL LINE FNC HAND/HEAD MIC SPKR
    HOLD XFR CONF WORK
    *0
    #TALLY
    8 795 462 13LOGONBREAK
    RLS NIGHT
    MO N/BARG E 
    						
    							NDA-24282 CHAPTER 3
    Page 27
    Revision 1.0
    INSTALLATION
    (2) Dterm Series E
    Figure 3-9   Key Pads on Supervisory Position Keyboard (Dterm Series E)
    NAP-200-102
    Sheet 3/3
    Installation of ACD Supervisory Position
    12
    3
    4 56
    789
    0# 
    CW
    ACDCALL LINE
    TRKTRBL RECALL
    FNC HAND/HEAD MIC SPKR
    BREAKRLS
    TA L LY
    WORKCONF
    XFR HOLD
    FLEX KEYMON/BARGENIGHTAU TO/ MA N
    LOGON 
    						
    							CHAPTER 3 NDA-24282
    Pag e 2 8
    Revision 1.0
    INSTALLATION
    Figure 3-10 shows the cable connection between the MIS and the NEAX2400 IMX.
    Figure 3-10   Cable Connection between MIS and PBX
    NAP-200-103
    Sheet 1/1
    Installation of MIS
    Note:When the client MIS and IVR/Host are installed in a system together, LAN network for these terminals
    should be separated by the router.
    00 01 02 03 04 05 06 07 08 09 10 11
    00 01 02 03 04 05 06 07 08 09 10 1112 13 14 15 16 17 18 19 20 21 22 23
    LANI (PZ-PC19)
    MIS
    HUB BASEULPM
    10BASE-T (Straight)
    PH-PC40 (EMA)
    PH-IO24 (IOC) 
    						
    							NDA-24282 CHAPTER 3
    Page 29
    Revision 1.0
    INSTALLATION
    Figures 3-11 and 3-12 show connection for an Emergency Recorder.
    Figure 3-11   Connection of Emergency Recorder 
    (When Emergency Recorder Has Starting Terminal)
    Figure 3-12   Connection of Emergency Recorder 
    (When Emergency Recorder Does Not Have Starting Terminal)
    NAP-200-104
    Sheet 1/1
    Installation of Emergency Recorder
    Emergency 
    Recorder
    AC
    A
    B
    G MD F
    R0
    T0
    M 
    (T1) 16COT
    No.0 circuit
    No.1 circuit
     -48V
    Power Receiving Terminal
    G -48V RPT0
    FUSE
    Speech Wires
    Starting Wire
    AC A
    B
    G MDF
    R0
    T0
    M 
    (T1) 16COT
    No.0 circuit
    No.1 circuit
     -48V
    Power Receiving 
    Terminal
    GRPT0
    Emergency
    RecorderPower Relay
    Note
    Starting Wire
    Speech WiresAC 
    Receptacle
    Note:If a power relay is used, select an optimum relay by
    confirming the amplifiers current drain.
      
    						
    							CHAPTER 3 NDA-24282
    Pag e 3 0
    Revision 1.0
    INSTALLATION
    The standard announcement machine available is PA-4DATA or PA-4DATB (4DAT: 4 Digital Announcement
    Trunk) card. The 4DAT can be used by simply inserting it in the universal slot of PIM.
    If a non-standard announcement machine is used, the connection method and the announcement trunk to be used
    as interface vary depending on the machine.
    An example of this connection is shown in Figure 3-13.
    Figure 3-13   Connection of Announcement Machine
    NAP-200-105
    Sheet 1/1
    Installation of Announcement Machine
    Announcement 
    Machine
    Fuse
    Power Receiving 
    TerminalG–48V RPT0 16 COT
    No.0 circuit
    No.1 circuitR0
    T0
    M 
    (T1)MDF
    OA
    OB
    OC 
    (RT)–48 G
    R1G 
    						
    							NDA-24282 CHAPTER 3
    Page 31
    Revision 1.0
    INSTALLATION
    Figure 3-14 shows the system configuration when IVR/Host is installed.
    For more details of IVR cable connection, refer to Figure 3-15 and for the Host connection, refer to Figure 3-16.
    Figure 3-14   System Configuration (when IVR/Host is installed)
    NAP-200-106
    Sheet 1/1
    Installation of IVR/Host
    Note:When the client MIS and IVR/Host are installed in a system together, LAN network directly connected
    with these terminals should be separated by the router.
    Router
    MIS IVR/Host
    Dterm
    (ACD Positions)
    E
    L
    C
    L
    C
    HUB
    PBXL
    A
    N
    L
    A
    N
    Note 
    						
    All NEC manuals Comments (0)

    Related Manuals for NEC Neax 2400 Imx Callcenterworx Enterprise Acd System Manual