    							CHAPTER 4 NDA-24282
    Pag e 9 2
    Revision 1.0
    PH-BS16 (PBI)
    4. Lamp Indications
    The contents of lamp indications of this circuit card are shown in the table below.
    LAMP NAME COLOR STATE
    AC TGreen Remains lit while the CPU which controls this circuit card is in ACT state.
    Red Lights with PBI Make Busy switch and MB switch turned on.
    OPE Green Lights when the CPU has accessed to this circuit card.
    PWRALM  Red Lights when the On-Board Power Supply equipped on this circuit card is faulty.
    EQBY Green Remains lit while the circuit card is in equipment busy state.
    B-OPE0Green Remains lit while BUS No. 0 of this circuit card is data transmitting and receiving.
    RedLights when BUS No. 0 of this circuit card has been placed into make-busy state by 
    SP or PBI Make Busy switch has been turned on.
    B-OPE1Green Remains lit while BUS No. 1 of this circuit card is data transmitting and receiving.
    RedLights when BUS No. 1 of this circuit card has been placed into make-busy state by 
    SP or PBI Make Busy switch has been turned on.
    TRBSY Green Lights when the send memory of this circuit card is busy.
    RVBSY Green Lights when the receive memory of this circuit card is busy.
    M-OPE Green Lights when the data have been received from M-BUS. 
    						
    							NDA-24282 CHAPTER 4
    Page 93
    Revision 1.0
    PH-BS16 (PBI)
    5. Switch Settings
    Standard settings of various switches on this circuit card are shown in the table below.
    SWITCH NAMESWITCH 
    NO.SETTINGSTAN-
    DARD 
    SETTINGMEANING
    MB
    UP Circuit card make busy.
    DOWN×Circuit card make idle.
    PBIH 
    7×Fixed
    PBIL
    0Not used.
    ~
    7Not used
    8ACDP0-System No. 0 (Mounted in Slot No. 13 
    of APMA0) (standard setting)
    9ACDP0- System No. 1(Mounted in Slot No. 14 
    of APMA0) (standard setting)
    AACDP1-System No. 0 (Mounted in Slot No. 13 
    of APMA1)
    BACDP1-System No. 1 (Mounted in Slot No. 14 
    of APMA1)
    CACDP2-System No. 0 (Mounted in Slot No. 13 
    of APMA2)
    DACDP2-System No. 1 (Mounted in Slot No. 14 
    of APMA2)
    E Not used
    F Not used
    ON
    ~ 
    						
    							CHAPTER 4 NDA-24282
    Pag e 9 4
    Revision 1.0
    PH-BS16 (PBI)
    SWITCH SETTING SHEET
    MODULE SLOT NO.SWITCH 
    NAMESWITCH SHAPE REMARKS
    13
    14MB UP: Circuit card make busy
    DOWN:Circuit card make idle
    PBIH 7: Fixed
    PBILON
    7 
    						
    							NDA-24282 CHAPTER 4
    Page 95
    Revision 1.0
    PA-GT17 (SPGT)
    PA-GT17 (SPGT)
    1. Function
    This circuit card is used when the MISCME module is required. This circuit card provides flow control and
    terminates the extention of the MISC bus. This circuit card also controls the alarm LEDs equipped in the
    To p  U n i t .
    Figure 4-2   Position in IMGdxh
    Single Configuration
    IMG0LOCAL I/O BUS
    TSW
    GT
    GTA
    GTA
    GTA To IMG 1
    To IMG 2
    To IMG 3
    EXGT
    EMA
    IOC
    MISC BUSCPRB-A
    HDD
    FDD
    APINT APINT APINT APINTMISCME
    SPGT
    INT
    IMG0
    LOCAL I/O
    TSW
    GT0
    GTA0
    GTA
    GTA To IMG 1
    To IMG 2
    To IMG 3
    EXGT0
    CPRB-A
    HDD#0
    FDD#0
    APINT APINT APINT APINTMISCME
    SPGT
    INT0
    Dual Configuration
    GT1
    GTA1
    GTA
    GTA
    EXGT1
    CPRB-A
    HDD 1
    FDD 1
    INT1
    EMA
    IOC
    To IMG 1
    To IMG 2
    To IMG 3
    BUS
    SPGT
    MISC BUS
    MISC BUS 
    						
    							CHAPTER 4 NDA-24282
    Pag e 9 6
    Revision 1.0
    PA-GT17 (SPGT)
    2. Mounting Location/Conditions
    The SPGT card mounts in the MISCME as shown below.
    3. Face Layout of Lamps, Switches, and Connectors
    The face layout of lamps, switches, and connectors of this circuit card is shown below.
    00 01 02 03 04 05 06 07 08 09 10 11 12 13 14 15 16 17 18 19 20 21 22 23
    Mounting Module MISCME
    SPGTSPGT
    SW10OPE
    MB
    CLK ALM
    DSPP
    ALM 
    						
    							NDA-24282 CHAPTER 4
    Page 97
    Revision 1.0
    PA-GT17 (SPGT)
    4. Lamp Indications
    The contents of lamp indications of this circuit card are shown in the table below.
    5. Switch Setting
    Standard settings of various switches on this circuit card are shown in the table below.
    LAMP NAME COLOR STATE
    OPE Green Remains lit while this circuit card is operating.
    CLK ALM Red Lights when a clock down occurred.
    SWITCH 
    NAMESWITCH 
    NO.SETTINGSTANDARD
    SETTINGMEANING
    MBON Circuit card make busy.
    OFF×Circuit card make idle.
    SW101OFF×Fixed.
    2OFF×Fixed. 
    						
    							CHAPTER 4 NDA-24282
    Pag e 9 8
    Revision 1.0
    PA-GT17 (SPGT)
    Switch Setting Sheet
    MODULE SLOT NO.SWITCH 
    NAMESWITCH SHAPE REMARKS
    MISCME 22 and 23MBUP: Circuit card make busy
    DOWN: Circuit card make idle
    SW0
    ON
    ON
    12 
    						
    							NDA-24282 CHAPTER 4
    Page 99
    Revision 1.0
    PA-16ELCDD (ELC)
    PA-16ELCDD (ELC)
    1. Function
    This circuit card is a line card which supports the interface of HDAC. When using voice only, 16 lines of
    HDAC can be connected to this circuit card. Further, by changing the switch setting, this circuit card can be
    connected with eight (8) lines respectively of voice terminals and data terminals.
    NUMBER OF 
    LINE 
    CIRCUITSNUMBER OF 
    TIME SLOTSDATA COMMUNICATION FUNCTION REMARKS
    8DLC Mode 8 circuits 16 Time Slots Available
    16ELC Mode 16 circuits 16 Time Slots Not Available
    C.O. Line COT INT
    T 
    S 
    W
    CPU MEM 16ch
    ELC 
    (PA-16ELCDD) Terminal 0 
     
    Terminal 7 
     
    Terminal 8 
     
    Terminal 15
    Note
    Position within the system
    Note:To be accommodated to Terminals 0~7 in 8DLC Mode. 
    						
    							CHAPTER 4 NDA-24282
    Pag e 1 00
    Revision 1.0
    PA-16ELCDD (ELC)
    2. Mounting Location/Condition
    The mounting locations of this circuit card and the conditions related to mounting are shown below.
    (a) When this circuit card is mounted in PIMA
    (b) When this circuit card is mounted in PIMB
    00 01 02 03 04 05 06 07 08 09 10 11 12 13 14 15 16 17 18 19 20 21 22 23
    Mounting Module PIMU-A
    00 01 02 03 04 05 06 07 08 09 10 11 12 13 14 15 16 17 18 19 20 21 22 23
    Mounting Module PIMB
    Note:  indicates the mounting locations of this circuit card. 
    						
    							NDA-24282 CHAPTER 4
    Page 101
    Revision 1.0
    PA-16ELCDD (ELC)
    3. Face Layout of Lamps, Switches, and Connectors
    The face layout of lamps, switches, and connectors of this circuit card is shown below.
    4. Lamp Indications
    The contents of lamp indications of this circuit card are shown in the table below.
    LAMP NAME COLOR STATE
    OPE  Green Remains lit while this circuit card is in operating normally.
    N-OPE  Red Remains lit while this circuit card is isolated from the system.
    PWRALM Red Lights when power supply to D
    term is abnormal on more than one circuit.
    BL0
    BL15Green Lights when the corresponding circuit is busy.
    FlashLights when the corresponding circuit is in make-busy state or when the related 
    system data is not assigned.
    MB
    PWRALM
    BLO
    SW0BL15
    N-OPE OP E
    ELC Connector
      
    						