    							CHAPTER 7 NDA-24282 (E)
    Pag e 3 72
    Revision 1.0
    ALGSN: Assignment of Telephone Station Data for NDM
    ALGSN: Assignment of Telephone Station Data for NDM
    1. General
    This command assigns the related data of the Telephone Number (TELN) corresponding to the physical
    station. The data assigned by this command is written in Network Data Memory (NDM) of the Network
    Control Node (NCN), updating the NDM at each Local Node (LN). 
    2.     Precautions
    1. The ALGSN command is used to assign the Telephone Number (TELN) for a Network Control Node
    (NCN).
    2. The TYPE parameter allows the user to choose the programming method of the physical station. 
    TYPE = 1 (LENS): Telephone number to be given to the LENS 
    TYPE = 2 (STN): Telephone number to be given to the station
    3. The system data assignment (ASYDN, SYS 1, INDEX 514, bit1 = 1) is needed to provide the Network
    Data Memory (NDM).
    4. When the parameter TYPE is “1” (LENS is used to specify the physical station number), the assignment
    of the Fusion Point Code (FPC) entered by the AFMU command is required. 
    5. For more details, see the NEAX2400 IMX Fusion Network System Manual.
    6. All PBX and ACD Station Numbers must be added here for Fusion Network. 
    						
    							NDA-24282 (E) CHAPTER 7
    Page 373
    Revision 1.0
    ALGSN: Assignment of Telephone Station Data for NDM
    3. Data Entry Instructions
     When assigning TYPE = 1 (LENS is used to specify the Telephone number) 
    When assigning TYPE = 2 (STN is used to specify the Telephone number) 
    TYPE
    1/2USER 
    GROUP 
    NUMBER
    (UGN)TELEPHONE NUMBER (TELN)
    MAX. 16 DIGITSLINE EQUIPMENT 
    NUMBER 
    (LENS)FUSION 
    POINT CODE
    (FPC)
    1-253
    115
    11
               4      0     0     0     0 0    0     0      0    1      1
         
         
    TYPE
    1 = LENS is used to specify the Telephone number
    2 = STN is used to specify the Telephone numberLENS
    LENS of the physical station
    UGN
    1 = User Group Number 1 (Fixed)LSTN
    Telephone number assigned by the ALGNN
    command.
    FPC
    Fusion Point Code (FPC) of the designated
    LENS. FPC is assigned by the AFMU com-
    mand.
    TN
    Tenant number of the physical station
    TYPE
    1/2USER 
    GROUP 
    NUMBER
    (UGN)TELEPHONE NUMBER (TELN)
    MAX. 16 DIGITSTENANT
    NUMBER 
    (TN)STATION
    NUMBER
    (STN)
    21 11
    214      0      0     0       02     5     6      4     5
    TYPE
    1 = LENS is used to specify the Telephone number
    2 = STN is used to specify the Telephone numberSTN
    Station number of the physical station
    UGN
    1 = User Group Number 1 (Fixed)
    LSTN
    Telephone number assigned by the ALGNN
    command. 
    						
    							CHAPTER 7 NDA-24282 (E)
    Pag e 3 74
    Revision 1.0
    ALGSN: Assignment of Telephone Station Data for NDM
    4. Data Sheet
    a. LENS is used to specify the Telephone number (TYPE = 1) 
    TYPEUSER GROUP 
    NUMBER (UGN)TELEPHONE NUMBER 
    (TELN)
    MAX. 16 DIGITSLINE EQUIPMENT 
    NUMBER 
    (LENS)FUSION POINT 
    CODE
    (FPC)
    11
    11
    11
    11
    11
    11
    11
    11
    11
    11
    11
    11
    11
    11
    11
    11
    11
    11
    11
    11
    11
    11
    11
    11
    11
    11
    11
    11
    11
    11
    11
    11
    11 
    						
    							NDA-24282 (E) CHAPTER 7
    Page 375
    Revision 1.0
    ALGSN: Assignment of Telephone Station Data for NDM
    b. STN is used to specify the Telephone number (TYPE = 2)
    TYPEUSER GROUP 
    NUMBER (UGN)TELEPHONE NUMBER (TELN)
    MAX. 16 DIGITSTENANT 
    NUMBER
    (TN)STATION
    NUMBER
    (STN)REMARKS
    21
    21
    21
    21
    21
    21
    21
    21
    21
    21
    21
    21
    21
    21
    21
    21
    21
    21
    21
    21
    21
    21
    21
    21
    21
    21
    21
    21
    21
    21
    21
    21
    21
    21 
    						
    							CHAPTER 7 NDA-24282
    Pag e 3 76
    Revision 1.0
    PBX AND ACD COMMAND PROGRAMMING
    2.2 ACD COMMANDS
    For NEAX2400 IMX Commands, see Section 2.1, “NEAX2400 IMX Commands” in this chapter.
    Table 7-2  ACD Command List
    COMMAND
    NAMEICON DESCRIPTION
    ACDTN Assignment of ACD Tenant Data
    ACDSPL Assignment of ACD Split Data
    ACDLOG Assignment of ACD Receiver ID Code
    ACDPSN Assignment of ACD Position Data
    ACDCCV Assignment of ACD CCV Data
    ACDPLT Assignment of ACD Monitor Number
    ACDTG Assignment of ACD Trunk Group Data
    ACDANA Assignment of ACD Analog Split Access Code
    ACDIVR Assignment of ACD IVR Data
    ACDHS Assignment of ACD Holiday Schedule
    ACDHC Assignment of ACD Holiday Calendar
    ACDWS Assignment of ACD Week Schedule
    ACDCOM ACD Communications Data
    System Information System Information
    ACD Backup ACD Backup 
    						
    							NDA-24282 CHAPTER 7
    Page 377
    Revision 1.0
    PBX AND ACD COMMAND PROGRAMMING
    2.2.1 Command Relationships
    Each command consists of a name (four to six alphanumeric characters) which suggests its function and the
    parameters required for its execution. Table 7-3 describes the correspondence among the ACD and PBX
    commands. Each ACD command may involve the assignment or execution of PBX commands and/or other
    ACD commands.
    Each command description includes a section entitled “Assignment and Deletion Procedure” which describes
    the correct sequence for applying related commands.
    Table 7-3  Related Commands 
    Command NameRelated PBX
     (Non-Fusion)
    CommandsRelated PBX Fusion
    CommandsRelated ACD Commands
    ACDTN ASYD, ANPD, ASPA, AADTASYD, ANPDN, ASPAN, 
    ASYDL, AADTN, ASYDNACDCOM, ACDSPL,
    ACDC CV
    ACDS PLAC DTN
    ACDLOG ACDTN, ACDSPL, ACDPSN
    AC DPS NAEFR, ASFC, ASDT, AKYD, 
    ARSCAEFR, ASFC, ASDT, AKYD, 
    ARSCN, ALGSNAC DSP L, ACD HS, AC DWS , 
    ACDH C, ACD TN
    ACDCCV AADT, ASDT AADTN, ASDT, ALGSNAC DSP L, ACD HS, AC DWS , 
    ADCHC, ACDTN
    ACDPLT AMNO, ACNO, ASATAMNON, ACNON, ALGNN, 
    ASATNACDTN, AC DCC V, AC DWS
    ACDTG ATRK, MBTK ALRTN ACDTN
    ACDANA AMNO ALGNN, AMNON ACDPSN
    ACDIVR ASDT, ASHU ASDT, ASHUN, ALGSN ACDTN
    ACDH SACDTN, ACDWS, ACDHS, 
    ACDC CV
    ADCHC ACDTN, ACDHS
    ACDWS ACDTN, AC DCC V, AC DPLT
    Total ACD
    SystemASYD (R), ASDT (R),
    AOKC (R), ARSC (R), 
    ASFC (R), AKYD (R), 
    AMNO (R), ACNO (O),
     AEFR (R), AADT (O),
     ASHU (O), SPDL (R), 
    ASAT (R), ROAI (O)ASYD (R), ASYDL (R), 
    ASDT (R), AOKC (R),
    ARSCN (R), ASFC (R),
    AKYD (R), AMNON (R),
    ACNON (O), AEFR (R),
    AADTN (O), ASHUN (O),
    SPDL (R), ASATN (R),
    ROAI (O), ALGNN (R)
    ALRTN (R), ALGSN (R)ACDTN (R), ACDSPL (R), 
    ACDLOG (O), ACDPSN (R), 
    ACDCCV (R), ACDPLT (R), 
    ACDTG (R) , ACDANA (O), 
    ACDIVR (O), ACDHS (O), 
    ACDHC  ( O), ACDWS  (O)
    (R) = Required, (O) = Optional 
    						
    							CHAPTER 7 NDA-24282
    Pag e 3 78
    Revision 1.0
    PBX AND ACD COMMAND PROGRAMMING
    2.3 SETTING UP THE ACD
    ACD parameters are set up in Windows 95 and Windows 98 using popup Windows. From the folder containing
    the IMX installation/maintenance files, select the ACDMAT ACD MAT System option.
    HouseSwitch - NECAM:IMXZ 1.5 -FPC 1
    F
    ile  View  PBX  Scan  Help
    MJ MN SUP TRF
    ACDMAT ACD MAT System
    System Control
    System Backup
    Make Busy Control
    Traffic Data
    Traffic Data for Fusion Network
    Test
    Station Data
    Trunk Data
    Numbering Plan
    Service Feature Data
    List Up Commands(1)
    List Up Commands(2)
    Signal Translation Data
    Restriction Data
    Installation
    Local Data Memory
    Event
    Tool
    Ready 
    						
    							NDA-24282 CHAPTER 7
    Page 379
    Revision 1.0
    PBX AND ACD COMMAND PROGRAMMING
    The IMX ACD MAT menu is displayed. Double-click the icon corresponding to the function you wish to set.
    To identify the function, place the cursor on the icon. The name of the function is displayed.
    Note:To use the ACD On-Line Help from any of the Windows, place the cursor in the box for the desired setting
    and press F1.
    IMX ACD MAT
    File  View  Options  MAT  Report  Window  Help
    Ready 
    						
    							CHAPTER 7 NDA-24282
    Pag e 3 80
    Revision 1.0
    ACDTN: ASSIGNMENT OF ACD TENANT DATA
    ACDTN: Assignment of ACD Tenant Data
    1. Function
    This command is used to assign, list, and print the following data for an ACD tenant:
    [1] Tenant Number
    [2] Tenant Name (optional)
    [3] The number (maximum) of splits (per tenant)
    [4] Default Language
    [5] Operator Access Code
    [6] IVR Pilot Number
    [7] Outbound Answer Timer
    [8] Agent Personal Queue Parameters:
    Announcement Number and Overflow/Forward Priority.
    Tenant data gives the user an identity within the ACD system. It also allows the tenant to determine the
    number of splits that will be needed for ACD operations.
    2. Precautions
    1. The ACDTN data is one of the most important data for ACD system configuration. The user must
    program the NSPL data carefully to lessen the need for future changes. If the NSPL data is changed,
    all data concerned with ACD function must be changed also.
    2. Since data related to MIS connection is assigned using TN 1, the following data must be set even when
    TN 1 is not used for the ACD system.
    TN=1, NSPL=1, PRI=1, LANG=0 *the data to be entered in other parameter is optional
    3. For the maximum number of splits per ACD, see Section 2.3.1, “System Capacity” in Chapter 2.
    4. Remove menu selection is not applicable for this command.
    5. Assign the number of tenants for whole system including Business/Hotel features (SYS1, Index8).
    Tenant Number: Name
    Splits:  IVR Plot Number  Outbound Answer Timer: 
    Operator Access Code:  Default Language:1ACD FPC40
    5030
    0English
    Agent Personal Queues
    Announcement Number:
    Overflow/Forward Priority:
    1
    1I/O Port Assignment:
    COM1 COM2
    COM3
      
    OffMISInfolink
    Remove
    List
    Close
    Tenant Data
    Remove Tenant? 
    						
    							NDA-24282 CHAPTER 7
    Page 381
    Revision 1.0
    ACDTN: ASSIGNMENT OF ACD TENANT DATA
    3. Parameters
    TENANT NUMBER: Tenant Number (1 to 10)
    NAME: Tenant Name (up to 20 characters)
    SPLITS: Maximum Split for Tenant (1 - 250)
    DEFAULT LANGUAGE: English
    Japanese
    Spanish
    Italian
    French
    German
    OPERATOR ACCESS CODE: Enter the operator access code programmed in the PBX subsystem
    (ASPA or ASPAN).
    IVR PILOT NUMBER: Number to access IVR directory numbers used by ACD
    ANSWER TIMER: Time (in seconds) after which an outbound call is assumed to have
    been answered.
    AGENT PERSONAL QUEUE: Personal Announcement Number (0 - 58) or SPACE: feature not
    used
    OVERFLOW/FORWARD PRIORITY: Priority to use for split queuing after overflow or call forwarding
    (1 to 250)
    I/O PORT ASSIGNMENT: MIS I/O Ports (1 to 6). Defines which of the MIS Ports are config-
    ured for this tenant. 
    						