CHAPTER 8 NDA-24282 Pag e 4 32 Revision 1.0 SYSTEM OPERATIONS 2.7 CALL TRANSFER Use the following procedure to transfer an ACD call to another split. 2.8 NIGHT SERVICE When the shift is over, the supervisory position can perform the following procedure to switch the entire split into the Night mode. (a) From Day mode to Night mode (b) From Night mode to Day modePress the XFER key. Special Dial Tone (SPDT) is heard. XFR (D term Series III) or XFR OPE (Dterm Series E) is displayed. Dial the ACD monitoring number of the transfer destination split. The call is immediately connected to one of the idle stations in the transfer destination split. If all stations in the transfer destination split are busy, the transfer originator hears the Ring Back Tone (RBT) and should wait for an answering agent or release the call to complete the transfer. The supervisor presses the NIGHT key. The lamp blinks, and ENTER NIGHT/FWD? is displayed. Dial 1 followed by the # key. The lamp lights, and the split is switched to Night mode. New incoming calls are no longer queued, and calls which have already been queuing are connected as soon as an agent position becomes idle. The supervisor presses the NIGHT key. The lamp blinks, and EXIT NIGHT? is displayed. Dial 1 followed by the # key. The lamp goes out, and the split is switched to Day mode. START END START END START END
NDA-24282 CHAPTER 8 Page 433 Revision 1.0 SYSTEM OPERATIONS 2.9 ASSISTANCE The agent position can request assistance from a supervisor during an ACD call. 2.10 EMERGENCY/RECORDER The agent can notify the supervisory position of abnormal calls such as harassment and request monitoring. If a recorder is provided, the conversation can also be recorded. Note:When the supervisor presses MON key while the agent is being monitored, “BARGE?” is displayed. At that time, the supervisor may enter the conversation by pressing 1 + #.The agent position presses the ASSIST key. ASSIST XXXX (Supervisory position name for the position with ID code or the ACD line number for the position without ID code) is displayed. The supervisor answers the assistance call. ASSIST XXXX (Agent position name for the position with ID code or the ACD line number for the position without ID code) is displayed. The supervisor and agent can confer while the ACD call is held with Consultation Hold. The agent presses the EMER key. EMER XXXX (Supervisory name for the position with ID code or the ACD line number for the position without ID code) is displayed. If a recorder is provided, recording of the call starts at the same time. The ACD CALL lamp and the MONITOR lamp on the supervisory position blink. When ringing starts, the supervisory confirms the display of EMER XXXX (Agent name or ACD line number), Trunk kind, Trunk number, and presses the LINE key. Note The monitoring can be terminated when the supervisor presses the RELEASE key. The call between the ACD call and agent position continues. The recording ends. (When activating three-way conference, see 2.11 Monitoring/Supervisory Override) START END START END
CHAPTER 8 NDA-24282 Pag e 4 34 Revision 1.0 SYSTEM OPERATIONS 2.11 MONITORING/SUPERVISORY OVERRIDE With the following procedure, the supervisory position can monitor a conversation between an agent position and ACD caller at any time, and can join the call by overriding if required. 3. ACD SYSTEM RESTART PROCESSING Since the ACDP is incorporated in the NEAX2400 IMX, perform the restart procedure of the NEAX2400 IMX referring to the “Installation Manual” or “System Operations and Maintenance Manual”. Monitoring Place Supervisor into the “Work” mode. Supervisory presses the MON/BARGE key. The lamp blinks. MONITOR NUMBER? is displayed. Dial the ID code of the agent to be monitored, or dial 0 followed by the non- ACD call s tation number of the agent position, and #. (Monitoring) Press MON/BARGE key again. BARGE? is displayed. Supervisory Override Dial 1 and #. The MON/BARGE lamp blinks. (Three-way conference call between the ACD call, agent position and supervisory position). Press the RELEASE or MON/BARGE key to end overriding. “CONF” lamp goes off and Return to Monitoring. START END
NDA-24282 (E) CHAPTER 9 Page 435 Revision 1.0 CHAPTER 9 SYSTEM MAINTENANCE 1. GENERAL This chapter explains the maintenance, diagnostics from system messages and fault recovery procedure respectively of the NEAX2400 CallCenterWorX-Enterprise ACD System. If any fault has been discovered in the course or as a result of maintenance operations, it should be diagnosed and repaired by referring to system messages concerned and the fault recovery procedure. Figure 9-1 Flow of Maintenance Work 2. MAINTENANCE 3. SYSTEM MESSAGES Message Detail Data System Messages for ACDP and MIS 4. FAULT DIAGNOSTICS Diagnostics from System Messages 5. FAULT RECOVERY PROCEDURE MIS (1) MIS Restart Processing Routine Maintenance Daily Maintenance
CHAPTER 9 NDA-24282 (E) Pag e 4 36 Revision 1.0 SYSTEM MAINTENANCE 2. MAINTENANCE 2.1 DAILY MAINTENANCE The daily maintenance of the ACD System consists of the following checking. Checking if the following system messages related to ACD system is displayed. 4-R: TCP/IP Link Failure 65-Q: ACD-MIS LOCK UP 6H: Bad Call Notification (ACD) 26-V: LAN Interface Error Report 2.1.1 THE RELATIONSHIP BETWEEN SYSTEM MESSAGES AND LAMP INDICATIONS When the system has detected a fault, the corresponding system message is given and simultaneously, the related lamp on the TOPU illuminates. Table 9-1 shows the relationship between system messages and lamp indications. Table 9-1 System Messages and Lamp Indications on the TOPU SYSTEM MESSAGE LAMP ON THE TOPU REMARKS NO. NAME MJ MN SUP NON 4-R TCP/IP Link Failure× 5-Q ACD-MIS LOCK UP× 6-H Bad Call Notification× 26-V LAN Interface Error Report×
NDA-24282 (E) CHAPTER 9 Page 437 Revision 1.0 SYSTEM MAINTENANCE 3. SYSTEM MESSAGES 3.1 SYSTEM MESSAGES AND THEIR MEANINGS The system messages shown in Table 9-2 is displayed when faults occur with the ACD within the IMX system. This table shows the system messages and their meaning. Table 9-2 System Messages for MIS SYSTEM MESSAGEMEANING FAULT CONTENTS 4-R TCP/IP Link FailureA fault has occurred to the UAP or to the line connected with the external computer. 5-Q ACD-MIS LOCK UPAbnormal occurrence, and the communication between ACDP and MIS has locked up. (To be displayed when ASYD command, SYS 1, INDEX 42, b2 = “1”.) 6-H Bad Call Notification This message is issued to indicate the result of Bad Call Notification. 26-VLAN Interface Error ReportA fault, related to the TCP/IP connection between the PBX and MIS/ HOST, occurred.
CHAPTER 9 NDA-24282 (E) Pag e 4 38 Revision 1.0 SYSTEM MAINTENANCE 3.2 MESSAGE DETAIL DATA This section describes the detailed information on the faults indicated by system messages (message detail data). 3.2.1 MESSAGE DETAIL DATA OF SYSTEM MESSAGE “4-R” System Message 4-R: TCP/IP Link Failure 1. Print-out Format 2. Print-out information (typical) When the PBX software Series 7300 and the ACD software R1 or earlier software are installed Fault port number: 0-5 Communication Protocol: 03 = ETHER + TCP/IP Error Code (ERR): Refer to the table below Note 1:This error code shows that the Host (UAP) is down manually. The option not to output this detail message at some offices can be programmed using SYS1, INDEX864, b1 in ASYDL (Messages other than ERR = 01 are output when TCP connection disconnected is not output). Note 2:This data is output when using PBX software Series 7300 or earlier. If installing PBX software Series 7300 or later, this information is output in the system message “26-V”. PROTOCOL ERROR CODECONTENT OF FAULT 03 (ETHER + TCP/IP)01 TCP Connection disconnected (Normal) Note 1 02 Reception of a text which cannot be analyzed Note 2 03~09 Not used 10 (0A) TCP Connection disconnected (on the way) Note 2 11 (0B) Transmission to PZ-PC19 (LANI) is disabled (Permanent) Note 2 12 (0C) Abnormal UAP is detected by Heart Beat function 13 (0D) Not used 14 (0E) TCP/IP Connection Error (B-level Infinite Loop, etc.) 15 (0F) ~ 255 (FF) Not used TCP/IP Link re SYSTEM MESSAGE 4 - R TCP/IP Link Failure NEC - ESD DEC 22 21:32 1: xx xx xx xx xx xx xx xx 2: xx xx xx xx xx xx xx xx 12345678910111213141516 1 2 3 23
NDA-24282 (E) CHAPTER 9 Page 439 Revision 1.0 SYSTEM MAINTENANCE Fault logical channel number (LCID): 01~10H (00 means the data is invalid) When the PBX software Series 7300 and the ACD software R2 or the later software are installed Fault port number: 0-5 Communication Protocol: 03 = ETHER + TCP/IP Error Code (ERR): Refer to the table below Note 1:This error code shows that the Host (UAP) is down manually. The option not to output this detail message at some offices can be programmed using SYS1, INDEX864, b1 in ASYDL (Messages other than ERRK = 01 are output when TCP connection disconnected is not output). Fault logical channel number (LCID): 01~10H (00 means the data is invalid) ~ IP address Relation between LCID and PBX TCP port number LCID TCP port number of the PBX 01 60030 PROTOCOL ERROR CODE CONTENT OF FAULT 03 (ETHER + TCP/IP)01 TCP Connection disconnected (Normal) Note 1 12 (0C) Abnormal UAP is detected by Heart Beat function 13 (0D) ~ 255 (FF) Not used Relation between LCID and PBX TCP port number LCID TCP port number of the PBX 01 60030 4 1 2 3 23 4 58
CHAPTER 9 NDA-24282 (E) Pag e 4 40 Revision 1.0 SYSTEM MAINTENANCE 3.2.2 MESSAGE DETAIL DATA OF SYSTEM MESSAGE “5-Q” System Message 5-Q: ACD-MIS LOCK UP This message is output when the PBX software release 5 and the ACD software release 1 or the later software are installed. (1) Print-out Format (2) Print-out information (typical) Each data is always displayed as “0”. : ACD-MISK UP SYSTEM MESSAGE 5 - Q ACD-MIS LOCK UP NEC - ESD MAY 11 22:30 1: 00 00 00 00 00 00 00 00 2: 00 00 00 00 00 00 00 00
NDA-24282 (E) CHAPTER 9 Page 441 Revision 1.0 SYSTEM MAINTENANCE 3.2.3 MESSAGE DETAIL DATA OF SYSTEM MESSAGE “6-H” System Message 6-H: Bad Call Notification (ACD) 1. Print-out Format 2. Print-out information (typical) Bad Call Notification 20=ACD trunk connection ACD Trouble Kind 01=ACD trunk trouble key 14=ACD reset start 15=Insufficient ACD memory 16=Insufficient ACD call record 17=Excessive business station on ACD calls 18=Excessive calls queued 21=Unknown Pilot No. called 24=Illegal execution of ACD timeout procedure 30=ACD pointer error detection and recovery 33=ACDP reset completion 34=Call recovery failure on unknown Pilot No. 37=ACD Traffic (incoming) Capacity Over Note 99=Illegal ACD processing - trace stored Note:Since the PBX software Series 7300 and the ACD software release 2. [When = 01 (Hex)] ~ : Information on Calling Party – Station ~ : My Line No. (Station) :00 – Trunk ~ : Route No. ~ : Trunk No. ~ : 00 00 ~ : Information on Calling Party – Station ~ : Station No. :00 – Trunk ~ : Route No. ~ : Trunk No. Bad CallficationD) SYSTEM MESSAGE 6 - H BAD CALL NOTIFICATION NEC - ESD AUG 14 17:00 1: xx xx xx xx xx xx xx xx 2: xx xx xx xx xx xx xx xx 12345678910111213141516 1 2 2 36 35 6 34 56 78 912 911 12 910 1112