CHAPTER 4 NDA-24282 (E) Pag e 1 62 Revision 1.0 PA-4DTLA (4DTL) NEAX2400 IMS B00MDF G R A004DTLModular JackDTE RS232 B B10 Y A10
NDA-24282 (E) CHAPTER 4 Page 163 Revision 1.0 PA-CC98 (ETHER) PA-CC98 (ETHER) Ethernet Controller 1. Functional Outline In the NEAX2400 ICS OAI System, this circuit card supports the functions for interface between the CPU (IP) circuit card and the external computer. If circuit card type, this circuit card is directly connected with the CPU card (PA-CP53). If module type, being paired with PA-GT (MBB) card, it connects the Interface Processor (IP) and the User Application Processor (UAP) through a LAN. CPU (No.0 Sys) (PA-CP53) ETHER (PA-CC98) Ethernet (a) If circuit card type CPU (No.0 Sys) (PA-CP54)CPU (No.1 Sys) (PA-CP54) MBB (PA-GT16) ALMC (PA-AL16) ETHER (PA-CC98)Ethernet (b) If module type (dual system configuration) Memory Bus (No.0 System)Memory Bus (No.1 System)
CHAPTER 4 NDA-24282 (E) Pag e 1 64 Revision 1.0 PA-CC98 (ETHER) 2. Circuit Card Mounting Locations/Conditions The mounting locations and conditions of this circuit card are shown below. (a) In the case of circuit card type When mounting in the PIMU-A When mounting in the PIMB Mounting Module PIMU-A 00 01 02 03 04 05 06 07 08 09 10 11 12 13 14 15 16 17 18 19 20 21 22 23 Note: Indicates the mounting locations of this circuit card. Mounting Module PIMB 00 01 02 03 04 05 06 07 08 09 10 11 12 13 14 15 16 17 18 19 20 21 22 23 Note: Indicates the mounting locations of this circuit card.
NDA-24282 (E) CHAPTER 4 Page 165 Revision 1.0 PA-CC98 (ETHER) (a) In the case of module type 3. Locations of Lamps, Switches, and Connectors The locations of lamps, switches, and connectors equipped on this circuit card are shown below. Mounting Module APM 00 01 02 03 04 05 06 07 08 09 10 11 12 13 14 15 16 17 18 19 20 21 22 23PA-CC98 SW0 BUS LAN FUSE OPE SW1ERR S2 S1 S3 SW2
CHAPTER 4 NDA-24282 (E) Pag e 1 66 Revision 1.0 PA-CC98 (ETHER) 4. Lamp Indications The meaning of indication of each lamp on this circuit card is shown below. 5. Switch Setting Each switch setting on this circuit card and its meaning are shown in the tables on the following pages. The CC98 Internet address is set by using the AIPT MAT command. For ICS and IMX, Internet is set only by the AIPT command. For HDS (IMG) configurations, the AIPT command is used for setting the Internet address for software versions J04.7 and higher. Contact NEC Personnel for Internet address settings in HDS software versions below J04.7. Each CC98 card must have a unique MAC address. This MAC address allows each CC98 to be different from each other and different from any other LAN system. The MAC address is twelve digits in length. Switches SW0 and SW1 are used to set the lowest three digits. The remainder of the MAC address is fixed. The Internet address set by AIPT is used with the MAC address to allow the CC98 to connect to LAN net- works. Note:If two or more CC98 cards are connected on the same LAN, each must have a unique MAC address. LAMP COLOR MEANING OF INDICATION OPE Green Remains lit while this circuit card is in operating status ERRRed When a fault has occurred within this circuit card, this lamp lights or flashes to- gether with lamp S1, S2, or S3 so as to specify the contents of the fault Red Flash S1Green FlashFlashes when data frame has been sent out onto the LAN S2 Green Lights when this circuit card is ready to operate S3 Green Remains lit while the power supply to this circuit card is on
NDA-24282 (E) CHAPTER 4 Page 167 Revision 1.0 PA-CC98 (ETHER) SWITCHDIP SW No.SETTINGDEFAULT SETTINGMEANING SW0 (8 DIP Switches)1ON Sets 0, corresponding to bit 0 of MAC address OFF Sets 1, corresponding to bit 0 of MAC address 2ON Sets 0, corresponding to bit 1 of MAC address OFF Sets 1, corresponding to bit 1 of MAC address 3ON Sets 0, corresponding to bit 2 of MAC address OFF Sets 1, corresponding to bit 2 of MAC address 4ON Sets 0, corresponding to bit 3 of MAC address OFF Sets 1, corresponding to bit 3 of MAC address 5ON Sets 0, corresponding to bit 4 of MAC address OFF Sets 1, corresponding to bit 4 of MAC address 6ON Sets 0, corresponding to bit 5 of MAC address OFF Sets 1, corresponding to bit 5 of MAC address 7ON Sets 0, corresponding to bit 6 of MAC address OFF Sets 1, corresponding to bit 6 of MAC address 8ON Sets 0, corresponding to bit 7 of MAC address OFF Sets 1, corresponding to bit 7 of MAC address Note:For switch setting for MAC address, refer to [Reference] shown below in the setting of SW1. For details of switch setting for Internet address, refer to the AIPT command explained in Chapter 7, ”PBX and ACD Command Pro- gramming”. SW1 (8 DIP Switches)1ON Sets 0, corresponding to bit 8 of MAC address OFF Sets 1, corresponding to bit 8 of MAC address 2ON Sets 0, corresponding to bit 9 of MAC address OFF Sets 1, corresponding to bit 9 of MAC address 3ON Sets 0, corresponding to bit 10 of MAC address OFF Sets 1, corresponding to bit 10 of MAC address 12345678 ON 12345678 ON
CHAPTER 4 NDA-24282 (E) Pag e 1 68 Revision 1.0 PA-CC98 (ETHER) SW1 (Continued) 4ON Sets 0, corresponding to bit 11 of MAC address OFF Sets 1, corresponding to bit 11 of MAC address 5ON×Fixed 6ON×Fixed 7ON×Fixed 8ON×Fixed [Reference] Setting of MAC address On LAN and TCP/IP, this circuit card can have the following addresses and ports. MAC Address: 000032250xxxH (48 bits) TCP Port Numbers: 16 port numbers of 1024 ~ 1039 The last 12 bits of MAC address must be set by switches SW0 and SW1 before starting up this circuit card. (Ex.) When MAC address is to be set to 000032250123H: By dividing 12 bits into 4-bit units (refer to the table on the right side), and set the switches as shown below. SW2 (Rotary SW)0Fixed setting (When operating) SWITCHDIP SW No.SETTINGDEFAULT SETTINGMEANING 0H 1H 2H 3H 4H 5H 6H 7H 8H 9H AH BH CH DH EH FH Relation between the value of 4 Bits and Switch Setting Hex Switch Setting 0 = Fixed (not used) SW0SW1 12345678 ON 32 12345678 ON 10
NDA-24282 (E) CHAPTER 4 Page 169 Revision 1.0 PA-CC98 (ETHER) MODULE SLOT SWITCH SWITCH SHAPE REMARKS SW0 SW1 SW2Fixed for the system12345678ON 12345678ON 0
CHAPTER 4 NDA-24282 (E) Pag e 1 70 Revision 1.0 PA-GT16 (MBB) PA-GT16 (MBB) Memory Bus Buffer 1. Functional Outline This circuit card is used in the OAI module type for the NEAX2400 IMX and ICS OAI System. It is a circuit card which repeats the memory bus on PA-CP54 (CPU) card side to ETHER (Ethernet Interface) gate card. 2. Circuit Card Mounting Locations/Conditions Mounting Module APM 00 01 02 03 04 05 06 07 08 09 10 11 12 13 14 15 16 17 18 19 20 21 22 23PA-GT16 CPU (No.0 Sys) (PA-CP54)CPU (No.1 Sys) (PA-CP54) MBB (PA-GT16) ALMC (PA-AL16) ETHER (PA-CC98)Ethernet Position within the system Memory Bus (No.0 System) Memory Bus (No.1 System)
NDA-24282 (E) CHAPTER 4 Page 171 Revision 1.0 PA-GT16 (MBB) 3. Locations of Lamps, Switches, and Connectors The locations of lamps, switches, and connectors equipped on this circuit card are shown below. 4. Lamp Indications The meaning of indication of each lamp on this circuit card is shown below. LAMP COLOR MEANING OF INDICATION OPE Green Remains lit while this circuit card and ETHER card are normally operating LAN ALM RedLights when the processor in ETHER card has become faulty or when ETHER card is not correctly connected with this circuit card SW0 BUS OPE SEG MB LAN ALM MBRQ