    							CHAPTER 4 NDA-24282 (E)
    Pag e 1 62
    Revision 1.0
    PA-4DTLA (4DTL)
    NEAX2400 IMS
    B00MDF
    G
    R
    A004DTLModular
    JackDTE RS232
    B
    B10
    Y
    A10 
    						
    							NDA-24282 (E) CHAPTER 4
    Page 163
    Revision 1.0
    PA-CC98 (ETHER)
    PA-CC98 (ETHER)
    Ethernet Controller
    1. Functional Outline
    In the NEAX2400 ICS OAI System, this circuit card supports the functions for interface between the CPU
    (IP) circuit card and the external computer. If circuit card type, this circuit card is directly connected with
    the CPU card (PA-CP53). If module type, being paired with PA-GT (MBB) card, it connects the Interface
    Processor (IP) and the User Application Processor (UAP) through a LAN.
    CPU (No.0 Sys) 
    (PA-CP53)
    ETHER 
    (PA-CC98)
    Ethernet
    (a) If circuit card type
    CPU (No.0 Sys) 
    (PA-CP54)CPU (No.1 Sys) 
    (PA-CP54)
    MBB 
    (PA-GT16)
    ALMC 
    (PA-AL16)
    ETHER 
    (PA-CC98)Ethernet
    (b) If module type (dual system configuration) Memory Bus 
    (No.0 System)Memory Bus 
    (No.1 System) 
    						
    							CHAPTER 4 NDA-24282 (E)
    Pag e 1 64
    Revision 1.0
    PA-CC98 (ETHER)
    2. Circuit Card Mounting Locations/Conditions
    The mounting locations and conditions of this circuit card are shown below.
    (a) In the case of circuit card type
     When mounting in the PIMU-A
     When mounting in the PIMB
    Mounting Module PIMU-A
    00 01 02 03 04 05 06 07 08 09 10 11 12 13 14 15 16 17 18 19 20 21 22 23
    Note:      Indicates the mounting locations of this circuit card.
    Mounting Module PIMB
    00 01 02 03 04 05 06 07 08 09 10 11 12 13 14 15 16 17 18 19 20 21 22 23
    Note:      Indicates the mounting locations of this circuit card. 
    						
    							NDA-24282 (E) CHAPTER 4
    Page 165
    Revision 1.0
    PA-CC98 (ETHER)
    (a) In the case of module type
    3. Locations of Lamps, Switches, and Connectors
    The locations of lamps, switches, and connectors equipped on this circuit card are shown below.
    Mounting Module APM
    00 01 02 03 04 05 06 07 08 09 10 11 12 13 14 15 16 17 18 19 20 21 22 23PA-CC98
    SW0
    BUS LAN FUSE OPE
    SW1ERR 
    S2 S1 
    S3
    SW2 
    						
    							CHAPTER 4 NDA-24282 (E)
    Pag e 1 66
    Revision 1.0
    PA-CC98 (ETHER)
    4. Lamp Indications
    The meaning of indication of each lamp on this circuit card is shown below.
    5. Switch Setting
    Each switch setting on this circuit card and its meaning are shown in the tables on the following pages.
    The CC98 Internet address is set by using the AIPT MAT command. For ICS and IMX, Internet is set only
    by the AIPT command. For HDS (IMG) configurations, the AIPT command is used for setting the Internet
    address for software versions J04.7 and higher.
    Contact NEC Personnel for Internet address settings in HDS software versions below J04.7.
    Each CC98 card must have a unique MAC address. This MAC address allows each CC98 to be different
    from each other and different from any other LAN system. The MAC address is twelve digits in length.
    Switches SW0 and SW1 are used to set the lowest three digits. The remainder of the MAC address is fixed.
    The Internet address set by AIPT is used with the MAC address to allow the CC98 to connect to LAN net-
    works.
    Note:If two or more CC98 cards are connected on the same LAN, each must have a unique MAC address.
    LAMP COLOR MEANING OF INDICATION
    OPE Green Remains lit while this circuit card is in operating status
    ERRRed When a fault has occurred within this circuit card, this lamp lights or flashes to-
    gether with lamp S1, S2, or S3 so as to specify the contents of the fault
    Red
    Flash
    S1Green
    FlashFlashes when data frame has been sent out onto the LAN
    S2 Green Lights when this circuit card is ready to operate
    S3 Green Remains lit while the power supply to this circuit card is on 
    						
    							NDA-24282 (E) CHAPTER 4
    Page 167
    Revision 1.0
    PA-CC98 (ETHER)
    SWITCHDIP SW 
    No.SETTINGDEFAULT 
    SETTINGMEANING
    SW0
    (8 DIP Switches)1ON Sets 0, corresponding to bit 0 of MAC address
    OFF Sets 1, corresponding to bit 0 of MAC address
    2ON Sets 0, corresponding to bit 1 of MAC address
    OFF Sets 1, corresponding to bit 1 of MAC address
    3ON Sets 0, corresponding to bit 2 of MAC address
    OFF Sets 1, corresponding to bit 2 of MAC address
    4ON Sets 0, corresponding to bit 3 of MAC address
    OFF Sets 1, corresponding to bit 3 of MAC address
    5ON Sets 0, corresponding to bit 4 of MAC address
    OFF Sets 1, corresponding to bit 4 of MAC address
    6ON Sets 0, corresponding to bit 5 of MAC address
    OFF Sets 1, corresponding to bit 5 of MAC address
    7ON Sets 0, corresponding to bit 6 of MAC address
    OFF Sets 1, corresponding to bit 6 of MAC address
    8ON Sets 0, corresponding to bit 7 of MAC address
    OFF Sets 1, corresponding to bit 7 of MAC address
    Note:For switch setting for MAC address, refer to [Reference] shown below in the
    setting of SW1. For details of switch setting for Internet address, refer to the
    AIPT command explained in Chapter 7, ”PBX and ACD Command Pro-
    gramming”.
    SW1
    (8 DIP Switches)1ON Sets 0, corresponding to bit 8 of MAC address
    OFF Sets 1, corresponding to bit 8 of MAC address
    2ON Sets 0, corresponding to bit 9 of MAC address
    OFF Sets 1, corresponding to bit 9 of MAC address
    3ON Sets 0, corresponding to bit 10 of MAC address
    OFF Sets 1, corresponding to bit 10 of MAC address
    12345678
    ON
    12345678
    ON 
    						
    							CHAPTER 4 NDA-24282 (E)
    Pag e 1 68
    Revision 1.0
    PA-CC98 (ETHER)
    SW1 (Continued)
    4ON Sets 0, corresponding to bit 11 of MAC address
    OFF Sets 1, corresponding to bit 11 of MAC address
    5ON×Fixed
    6ON×Fixed
    7ON×Fixed
    8ON×Fixed
    [Reference]
    Setting of MAC address
    On LAN and TCP/IP, this circuit card can have the following 
    addresses and ports.
    MAC Address: 000032250xxxH (48 bits)
    TCP Port Numbers: 16 port numbers of 1024 ~ 1039
    The last 12 bits of MAC address must be set by switches 
    SW0 and SW1 before starting up this circuit card.
    (Ex.)
    When MAC address is to be set to 000032250123H:
    By dividing 12 bits into 4-bit units (refer to the table on the 
    right side), and set the switches as shown below.
    SW2
    (Rotary SW)0Fixed setting (When operating)
    SWITCHDIP SW 
    No.SETTINGDEFAULT 
    SETTINGMEANING
    0H
    1H
    2H
    3H
    4H
    5H
    6H
    7H
    8H
    9H
    AH
    BH
    CH
    DH
    EH
    FH
    Relation between the value 
    of 4 Bits and Switch Setting
    Hex Switch Setting
    0 = Fixed (not used) SW0SW1
    12345678
    ON
    32
    12345678
    ON
    10 
    						
    							NDA-24282 (E) CHAPTER 4
    Page 169
    Revision 1.0
    PA-CC98 (ETHER)
    MODULE SLOT SWITCH SWITCH SHAPE REMARKS
    SW0
    SW1
    SW2Fixed for the system12345678ON
    12345678ON
    0 
    						
    							CHAPTER 4 NDA-24282 (E)
    Pag e 1 70
    Revision 1.0
    PA-GT16 (MBB)
    PA-GT16 (MBB)
    Memory Bus Buffer
    1. Functional Outline
    This circuit card is used in the OAI module type for the NEAX2400 IMX and ICS OAI System. It is a circuit
    card which repeats the memory bus on PA-CP54 (CPU) card side to ETHER (Ethernet Interface) gate card.
    2. Circuit Card Mounting Locations/Conditions
    Mounting Module APM
    00 01 02 03 04 05 06 07 08 09 10 11 12 13 14 15 16 17 18 19 20 21 22 23PA-GT16
    CPU (No.0 Sys) 
    (PA-CP54)CPU (No.1 Sys) 
    (PA-CP54)
    MBB 
    (PA-GT16)
    ALMC 
    (PA-AL16)
    ETHER 
    (PA-CC98)Ethernet
    Position within the system Memory Bus (No.0 System) Memory Bus (No.1 System) 
    						
    							NDA-24282 (E) CHAPTER 4
    Page 171
    Revision 1.0
    PA-GT16 (MBB)
    3. Locations of Lamps, Switches, and Connectors
    The locations of lamps, switches, and connectors equipped on this circuit card are shown below.
    4. Lamp Indications
    The meaning of indication of each lamp on this circuit card is shown below.
    LAMP COLOR MEANING OF INDICATION
    OPE Green Remains lit while this circuit card and ETHER card are normally operating
    LAN ALM RedLights when the processor in ETHER card has become faulty or when ETHER 
    card is not correctly connected with this circuit card
    SW0
    BUS OPE
    SEG
    MB
    LAN ALM 
    MBRQ 
    						