NEC Neax 2400 Imx Callcenterworx Enterprise Acd System Manual
Have a look at the manual NEC Neax 2400 Imx Callcenterworx Enterprise Acd System Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 1168 NEC manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.
CHAPTER 3 NDA-24282 Pag e 3 2 Revision 1.0 INSTALLATION Figure 3-15 shows the cable connection between Host and the PBX. Figure 3-15 Connection of Host Note: When the client MIS and IVR/Host are installed in a system together, LAN network directly connected with these terminals should be separated by the router. LANI LANI 10BASE-T (Straight) 10BASE-T (Straight) 10BASE-T (Straight) HUB PKG PIM LPM BASEU
NDA-24282 CHAPTER 3 Page 33 Revision 1.0 INSTALLATION Figure 3-16 shows the cable connection between IVR and the PBX. Figure 3-16 Connection of IVR PIM 16LC A0 B0 A1 B1 ~ A15 B15 NoteL2 L1 L2 L1IVR Rosette MDF Installation cable Note:Connector leads (A0, B0) may be connected differently.
CHAPTER 3 NDA-24282 Pag e 3 4 Revision 1.0 INSTALLATION 4. SYSTEM START-UP PROCEDURE FOR ADDING ACD FEATURES 4.1 ACD SOFTWARE INSTALLATION This section explains the installation procedure for adding the Built-in ACDP software to the PBX in on-line operation. For more detailed information about start-up procedures before the ACD application software install, see the “Installation Manual”. [Operation Procedure] a. Basic Operating Procedure STEP 1 : By using MEM_HDD command, save all data to both HDDs. STEP 2 : Insert the Built-in ACDP software FD into the HDD of the PBX. Note 1:When ACD service is used in a Fusion Network and when “ACD Trunk in a FCCS Network” is used: Install the software into the node that accommodates the ACDP. When “AGENT ANYWHERE” is used: Install the software into one node only. In this case, the node with the most ACD agent positions is recom- mended to prevent network traffic congestion. The node that uses the ACDP is most recommended accord- ing to the service condition Item 3 described in “Agent Anywhere - ACD” in Chapter 5. STEP 3 : Install the Configuration Software to all nodes. Note 2 Note 2: This software is used to define the CallCenterWorX-Enterprise (ACD) system capacity (50, 200, 500, 900, or 2000 Agent Positions). STEP 4 : Initialize the system (perform IPL, DM loading). PROGRAM=“LOAD” SYSTEM DATA=“LOAD”
NDA-24282 CHAPTER 3 Page 35 Revision 1.0 INSTALLATION b. When Installing ACD Trunk into Multiple Fusion Nodes (Software installation when the ACD trunk is in- stalled at Fusion Nodes.) (1) At the node that uses the ACDP, the ACD software (Built-in ACDP software) and ACD Option Soft- ware installation is necessary. (2) At the node that accommodates the ACD trunk, only ACD Option Software installation is necessary. Do not install the ACD software. (3) Initialize the node that uses the ACDP after the software installation. c. When Installing ACD Agent Position into Multiple Fusion Nodes (For PBX Software Series 7300 or later) (1) At the node that uses the ACDP, the ACD software (Built-in ACDP software) and the basic ACD Option Software, installation is necessary. (2) At the node that accommodates the ACD trunk, ACD agent position, the basic ACD Option Service Software must be installed. (3) Initialize the node that uses the ACDP after the software installation. d. When Installing ACDP into Multiple Fusion Nodes (For PBX Software Series 7400 or later) (1) At the node that uses the ACDP, the ACD software (Built-in ACDP software) and ACD Option Soft- ware installation is necessary. (2) At the node that accommodates the ACD trunk, only ACD Option Software installation is necessary. Do not install the ACD software. (3) Initialize the node that uses the ACDP after the initialization of the other nodes (non-ACDP nodes).
CHAPTER 3 NDA-24282 Pag e 3 6 Revision 1.0 INSTALLATION 4.2 BASIC DATA ASSIGNMENT FOR START-UP STEP 1 : Change the system data written in DM. ASYD SYS1 INDEX2 - b0=1 (ACDP mounted) INDEX31 - b0~b3: CM mounting capacity Assign Normally “06”. Note 1 INDEX79 - b6=0 (ACD service is effective) Note 1 INDEX207 - b0=1 (ACDP in system0 is used) b1: ACDP in system1 0/1=Not used/Used INDEX241 - b2=1 (call event process) Note 1 Note 1: When the ACD service is activated via FCCS, this data must be set to all nodes providing ACD service (Not just the node accommodating the ACDP). STEP 2 : Assign the system data written in LDM as shown below. ASYDL SYS1 INDEX512: FPC of the self-node INDEX513: 01 Hex (LDM usage) INDEX515~518 b0~b7: IP address (Hex) for PBX over external LAN Note 2 INDEX519~522 b0~b7: Subnet Mask (Hex) for PBX over external LANNote 2 INDEX523~526 b0~b7: Default Gateway Address for External LAN (This data is required when the Host is connected via gateway) Note 2 INDEX864 - b0=1 (Built-in ACDP is provided) INDEX864 b1: Output the system message (4-R) when TCP-IP is normally disconnected. 0/1 = Effective/Ineffective Note 3 b2: 0/1 = “Agent Anywhere” Out of Service/In Service b3: 0/1 = Multiple ACDPs Not Available/Available INDEX865: FPC of Node Providing IP. INDEX866: FPC of Node Providing ACDP. Note 2:If the MAT or SMDR has been connected with external LAN already, this data assignment is not necessary. STEP 3 : Assign the System data written in NDM. This data is necessary when using “AGENT ANYWHERE” (Available since the PBX software Series 7300.) ASYDN SYS1 INDEX514- NDM usage INDEX533- FPC of the node that provides VNDM STEP 4 : Check the station-to-station connection and confirm no fault status occurs or system messages are output (such as cable connection fault, LCD display fault, memory alarm fault, abnormal interrupt, etc.). STEP 5 : Program the ACD office data. Also, program the Fusion data to make ACD service effective through Fusion network, if necessary. Refer to Chapter 5, “Office Data Design”. STEP 6 : Save the DM, ACD data memory into the HDD by using MEM_HDD.
NDA-24282 CHAPTER 3 Page 37 Revision 1.0 INSTALLATION 5. UPGRADING ACD SYSTEM FROM NEAX2400 ICS TO NEAX2400 IMX Figure 3-17 and Table 3-1 show the requirements when upgrading the CallCenterWorX-Enerprise (ACD) sys- tem from NEAX2400 ICS to 2400 IMX. 5.1 HARDWARE AND SOFTWARE REQUIREMENTS Figure 3-17 Hardware and Software Upgrading Requirements (See Table 3-1.) PBX MAT Router [9]Server MIS DM CPU ACD DMLAN MIS DBClient MIS [3] [1] [2] [4][5] [6] [7][8] ACDP IVR/Host [10] Note 1:[5], [6], [7], [8] are not necessary for the ACD without MIS. Note 2: [10] is not necessary for the ACD without IVR/Host.
CHAPTER 3 NDA-24282 Pag e 3 8 Revision 1.0 INSTALLATION Table 3-1 Hardware and Software Upgrading Requirements No.Upgrading Hardware or SoftwareNEAX2400 ICS (before upgrading)NEAX2400 IMX (after upgrading) [1]Generic Software Basic software Standard Service software Optional softwareAll types of system PBX software Release 3 or later Basic software (#1~#11) Internal MAT software (#1~#2) TCP/IP software [2]ACD software SC-2242 PRG-E or SC-2243 PRG-FBuilt-in ACDP software [3]MAT Hardware and SoftwareIBMPC/AT Windows [4]ACD Data Memory PBX software Release 2 or Release 3Built-in type Necessary to be reprogrammed via [3] [5], [6]Server MISHardware and SoftwareNavigator MIS (IBMPC/AT) Navigator MIS (IBMPC/AT) For NEAX2400 IMX system [7]Data base (Config., static data, etc.)Navigator MIS (IBMPC/AT) Navigator MIS (IBMPC/AT) [8]Client MIS terminal Software Navigator MIS (IBMPC/AT) (a) Remote MIS terminal MIS terminal for Navigator MIS (IBMPC/AT) (b) Client MIS terminal Navigator MIS client for NEAX2400 IMX system [9] Router – Router [10]IVR/Host Hardware and Soft- ware Note:Necessary when IVR/ Host is added only.
NDA-24282 CHAPTER 3 Page 39 Revision 1.0 INSTALLATION 5.2 UPGRADING PROCEDURE STEP 1 : Print out the existent data in the MIS terminal or save the data as the text file.Note 4 STEP 2 : List up the office data related to the current ACDP. STEP 3 : Shutdown MIS operation following the appropriate procedure. Note 4 STEP 4 : Make busy the CPU (ACDP) card (CP53/CP54) and disconnect all cables connected to cards related to ACD. STEP 5 : Upgrade the PBX hardware following the Upgrade Manual for the PBX. STEP 6 : Install the software below to upgrade the PBX software. Refer to Chapter 3, Section 4.1, “ACD Software Installation”. An assortment of software for NEAX2400 IMX Built-in ACDP software Note 1 System Configuration Software containing ACD OptionsNote 2 STEP 7 : Program the following ACD commands data again. ACDTN/ACDSPL/ACDLOG/ACDPSN/ACDCCV/ACDPLT/ACDTG/ACDANA/ACDIVR/ ACDHS/ACDHC/ACDWS STEP 8 : Start up the Navigator MIS for IBMPC/AT. Note 3 Standard MIS hardware and software MIS terminal hardware and software STEP 9 : Start up the IVR/Host. Note 4 IVR/Host hardware and software Related Equipment for LAN STEP 10 : Perform the installation test. Note 1:When ACD service is used in a Fusion Network, and when “ACD Trunk in aFusion Network” is used: Install the software into the node that accommodates the ACDP. When “AGENT ANYWHERE” is used: Install the software into one node only. In this case, the node with the most ACD agent positions is recommended to prevent network traffic congestion. The node that uses the ACDP is most recommended according to the service condition Item 3 described in “Agent Anywhere - ACD” in Chapter 5. Note 2:When ACD features are activated in Fusion network, this software is installed in all nodes. Note 3:This procedure is not necessary for the ACD without MIS. Note 4:Details for start-up procedure are decided by the IVR/Host feature specifications. This procedure is not necessary when IVR/Host is not used.
CHAPTER 3 NDA-24282 Pag e 4 0 Revision 1.0 This page is for your notes.
NDA-24282 CHAPTER 4 Page 41 Revision 1.0 CHAPTER 4 SWITCH SETTING OF ACD CIRCUIT CARDS 1. GENERAL This chapter explains the circuit cards related to the NEAX2400 CallCenterWorX-Enterprise (ACD) System which are shown in Table 4-1. Table 4-1 List of ACD Circuit Cards SYMBOL CIRCUIT CARDMOUNTING MODULEREMARKS CPU PA-CP53 PIMU For circuit card type EAPI PH-PC22/PH-PC27 LPRJ-A ALMC PA-AL16 APM For module type APINT PH-PC21 LPRJ-A COPY PA-PC56-A APM CPU PA-CP54 APM CRAM PA-ME34 APM IOC PA-IO02-A APM PBI PH-BS16 APM SPGT PA-GT17 MISCME For MISCME type ELC PA-16ELCDD PIMU Common 16ELC PA-16ELCH PIMU Common 16ELC PA-16ELCJ PIMU Common 4DAT PA-4DATA PIMU Common DAT PA-4DATB PIMU Common 4DTL PA-4DTLA PIMU Common ETHER PA-CC98 APM/PIMU Module/Package MBB PA-GT16 APM Module