Home > NEC > Communications System > NEC Neax 2400 Imx Callcenterworx Enterprise Acd System Manual

NEC Neax 2400 Imx Callcenterworx Enterprise Acd System Manual

    Download as PDF Print this page Share this page

    Have a look at the manual NEC Neax 2400 Imx Callcenterworx Enterprise Acd System Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 1168 NEC manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.

    Page
    of 485
    							CHAPTER 4 NDA-24282
    Pag e 8 2
    Revision 1.0
    PA-ME34 (CRAM)
    SWITCH SETTING SHEET
    MODULE SLOT NO.SWITCH 
    NAMESWITCH SHAPE REMARKS
    APM-A\E 06
    08
    19DMWDK
    SW0
    SW1ON
    ON
    12345678
    ON
    12 
    						
    							NDA-24282 CHAPTER 4
    Page 83
    Revision 1.0
    PA-IO02-A (IOC)
    PA-IO02-A (IOC)
    1. Function
    This circuit card is an I/O card (input/output control card) and provides a serial interface function by which
    the CPU performs mutual communications with the ACD-MIS conforming with the RS-232C Interface.
    2. Mounting Location/Condition
    The mounting locations of this circuit card and the conditions related to mounting are shown below.
    CPUCPU
    COPYCOPY
    CRAMCRAM
    IOC
    APM-A\E
    ALMC
    RS-232C (Non-protocol)
    Position within the system
    (ACDP) (ACDP)
    00 01 02 03 04 05 06 07 08 09 10 11 12 13 14 15 16 17 18 19 20 21 22 23
    Mounting Module APM-A\E
    PA-IO02-A PA-IO02-APA-IO02-A 
    						
    							CHAPTER 4 NDA-24282
    Pag e 8 4
    Revision 1.0
    PA-IO02-A (IOC)
    3. Face Layout of Lamps, Switches, and Connectors
    The face layout of lamps, switches, and connectors of this circuit card is shown below.
    4. Lamp Indications
    The contents of lamp indications of this circuit card are shown in the table below.
    LAMP NAME COLOR STATE
    OPE  Green Remains lit while this circuit card is operating in ACT mode.
    ON LINE1 Green Remains lit while PORT 1 is in on-line state.
    ON LINE0 Green Remains lit while PORT 0 is in on-line state.
    OP E
    MB
    SW3ON LINE1 
    ON LINE0
    MB REQ
    SW0
    SW01SW11
    SW02 SW12
    OFF LINE 
    						
    							NDA-24282 CHAPTER 4
    Page 85
    Revision 1.0
    PA-IO02-A (IOC)
    5. Switch Settings
    Standard settings of various switches on this circuit card are shown in the table below.
    SWITCH 
    NAMESWITCH NO. SETTINGSTANDARD 
    SETTINGMEANING
    MB UP Circuit card make busy.
    DOWN Circuit card make idle.
    MB REQ UP Circuit card make busy.
    DOWN Circuit card make idle.
    OFF LINE UP Setting is inhibited.
    MIDDLE×Fixed.
    DOWN Setting is inhibited.
    SW0
    1
    2
    3OFF×
    4OFF×
    5OFF×
    6OFF×
    7OFF×
    8OFF×
    SW3 1 OFF×
    2OFF×
    3OFF×
    4OFF×
    SW0-1 SW0-2 SETTING OF IOC EQUIPMENT NUMBER
    OFF OFF Sets IOC Equipment Number 0.
    OFF ON Sets IOC Equipment Number 1.
    ON OFF Sets IOC Equipment Number 2.
    Fixed
    Fixed 
    						
    							CHAPTER 4 NDA-24282
    Pag e 8 6
    Revision 1.0
    PA-IO02-A (IOC)
    SW1
     (for Port 0)
    SW11
    (for Port 1)1
    2
    3
    4
    5
    6ON×Data Length: 7 bits
    OFF Data Length: 8 bits
    7ON×Stop Bit: 1 bits 
    OFF Stop Bit: 2 bits 
    8ONData store into the send-side buffer of the port 
    is disabled.
    OFF×Data of max. 64 kbytes are to be stored into the 
    send-side buffer of the port.
    SWITCH 
    NAMESWITCH NO. SETTINGSTANDARD 
    SETTINGMEANING
    SW01-1
    SW11-1SW01-2
    SW11-2SW01-3
    SW11-3DATA TRANSMISSION SPEED 
    (BPS) SETTING
    ON ON ON 300 bps
    ON ON OFF 600 bps
    ON OFF ON 1200 bps
    ON OFF OFF 2400 bps
    OFF ON ON 4800 bps
    OFF ON OFF 9600 bps
    SW01-4
    SW11-4SW01-5
    SW11-5PARITY SETTING
    ON ON ODD Parity
    ON OFF EVEN Parity (standard setting)
    OFF OFF No Parity 
    						
    							NDA-24282 CHAPTER 4
    Page 87
    Revision 1.0
    PA-IO02-A (IOC)
    Note:
    When setting SW02-7/SW12-7 to ON, set SW02-1/SW12-1 to ON, also. SW02
     (for Port 0)
    SW12
     (for Port 1)1ON×PB terminal becomes minus (-) when the port 
    terminal is busy.
    OFFPB terminal becomes plus (+) when the port 
    terminal is busy.
    2ON×Sets the ER terminal of the port to Always ON.
    OFFControls ON/OFF of the ER terminal of the 
    port by the CPU.
    3ON DR signal lead is not to be used to the port.
    OFF×DR signal lead is to be used to the port.
    4ON×CD signal lead is not to be used to the port.
    OFF CD signal lead is to be used to the port.
    5ON CS signal lead is not to be used to the port.
    OFF×CS signal lead is to be used to the port.
    6ON CI signal lead is not to be used to the port.
    OFF×CI signal lead is to be used to the port.
    7ON×PB signal lead is not to be used to the port. 
    Note
    OFF PB signal lead is to be used to the port.
    8OFF×Not used.
    SWITCH 
    NAMESWITCH NO. SETTINGSTANDARD 
    SETTINGMEANING 
    						
    							CHAPTER 4 NDA-24282
    Pag e 8 8
    Revision 1.0
    PA-IO02-A (IOC)
    6. External Interface
    The RS connector leads accommodation of this circuit card is shown below.
    Figure 4-1   RS Connector Leads Accommodation
    26 
    27 
    28 
    29 
    30 
    31 
    32 
    33 
    34 
    35 
    36 
    37 
    38 
    39 
    40 
    41 
    42 
    43 
    44 
    45 
    46 
    47 
    48 
    49 
    50
    00 01 02 03 04 05 06 07 08 09 10 11 12 13 14 15 16 17 18 19 20 21 22 23
    RS0
    APM-A\E Slot No.
    E 
    E 
    E 
    E 
    E 
    CI0 
    E 
    E 
    E 
    E 
    E 
    E 
    E 
    E 
    E 
    E 
    E 
    CI1 
    E 
    E 
    E 
    E 
    E 
    E 
    EXTA1 
    2 
    3 
    4 
    5 
    6 
    7 
    8 
    9 
    10 
    11 
    12 
    13 
    14 
    15 
    16 
    17 
    18 
    19 
    20 
    21 
    22 
    23 
    24 
    25
    PA-IO02-A
    RS Connector Leads Accommodation
    RS0 Connector
    SD0 
    RD0 
    RS0 
    CS0 
    DR0 
    SG0 
    CD0 
    ER0 
    PB0 
    SP00 
    SP10 
    SP20 
    SD1 
    RD1 
    RS1 
    CS1 
    DR1 
    SG1 
    CD1 
    ER1 
    PB1 
    SP01 
    SP11 
    SP21 
    EXTB 
      
    						
    							NDA-24282 CHAPTER 4
    Page 89
    Revision 1.0
    PA-IO02-A (IOC)
    SWITCH SETTING SHEET
    MODULE SLOT NO.SWITCH 
    NAMESWITCH SHAPE REMARKS
    APM-A\E 04 MB UP: Circuit card make busy.
    MB REQ DOWN:Circuit card make idle.
    OFF LINE
    SW0
    SW3
    SW01
    SW02
    SW11
    SW12ON
    ON
    ON
    ON
    12345678
    ON
    1234
    ON
    12345678
    ON
    12345678
    ON
    12345678
    ON
    12345678 
    						
    							CHAPTER 4 NDA-24282
    Pag e 9 0
    Revision 1.0
    PH-BS16 (PBI)
    PH-BS16 (PBI)
    1. Function
    This circuit card provides an interface by which the ACDP performs inter-processor communications  with
    another Processor via the Processor Bus (P-BUS) under control of the ACDP (PA-CP54 card). Also, this
    circuit card is connected with the Maintenance Bus (M-BUS) and provides functions that allow the SP
    (System Processor) to read out status or fault information of the ACDP and that cause the ACDP to set make-
    busy or perform initialization.
    2. Mounting Location/Condition
    The mounting locations of this circuit card and the conditions related to mounting are shown below.
    CPU 
    (ACDP)
    PBISP0 
    SPCSP1 
    SPC
    MEM
    M-BUS No.0
    M-BUS No.1
    P-BUS No.0
    P-BUS No.1To other 
    processor
    To other 
    processor
    Position within the system
    00 01 02 03 04 05 06 07 08 09 10 11 12 13 14 15 16 17 18 19 20 21 22 23
    Mounting Module APM-A\E
    PH-BS16PH-BS16
    For No. 1 system
    For No. 0 system 
    						
    							NDA-24282 CHAPTER 4
    Page 91
    Revision 1.0
    PH-BS16 (PBI)
    3. Face Layout of Lamps, Switches, and Connectors
    The face layout of lamps, switches, and connectors of this circuit card is shown below.
    OPE
    MB
    PWRALM
    ACT
    EQBY
    PBIH
    PBIL
    B-OPE0
    B-OPE1
    TR BSY 
    RV BSY 
    M-OPE 
    						
    All NEC manuals Comments (0)