    							CHAPTER 4 NDA-24282 (E)
    Pag e 1 52
    Revision 1.0
    PA-4DATB (DAT)
    Figure 4-16   LT Connector Lead Accommodation (PIME)
    E
    FM
    EFM26 
    27 
    28 
    29 
    30 
    31 
    32 
    33 
    34 
    35 
    36 
    37 
    38 
    39 
    40 
    41 
    42 
    43 
    44 
    45 
    46 
    47 
    48 
    49 
    50
    00 01 02 03 04 0506 07 0809
    1011
    12 13 1415
    16 1718
    192021 22
    23
    LT2
    PIME Slot No.
     1 
    2 
    3 
    4 
    5 
    6 
    7 
    8 
    9 
    10 
    11 
    12 
    13 
    14 
    15 
    16 
    17 
    18 
    19 
    20 
    21 
    22 
    23 
    24 
    25
    Group No.
    LT3LT4LT5LT6LT7LT8LT9LT10LT11LT12LT13
    01 
    0003 
    0205 
    0407 
    0609 
    0811 
    1001 
    0003 
    0205 
    0407 
    0609 
    0811 
    1015 
    14  13 
    1219 
    18  17 
    1623 
    22  21 
    2015 
    14  13 
    1219 
    18  17 
    1621 
    20
    Highway BlockHW0HW1HW2HW11
    26 
    27 
    28 
    29 
    30 
    31 
    32 
    33 
    34 
    35 
    36 
    37 
    38 
    39 
    40 
    41 
    42 
    43 
    44 
    45 
    46 
    47 
    48 
    49 
    50 1 
    2 
    3 
    4 
    5 
    6 
    7 
    8 
    9 
    10 
    11 
    12 
    13 
    14 
    15 
    16 
    17 
    18 
    19 
    20 
    21 
    22 
    23 
    24 
    25 26 
    27 
    28 
    29 
    30 
    31 
    32 
    33 
    34 
    35 
    36 
    37 
    38 
    39 
    40 
    41 
    42 
    43 
    44 
    45 
    46 
    47 
    48 
    49 
    50
     1 
    2 
    3 
    4 
    5 
    6 
    7 
    8 
    9 
    10 
    11 
    12 
    13 
    14 
    15 
    16 
    17 
    18 
    19 
    20 
    21 
    22 
    23 
    24 
    25 LT0, 2, 4, 6, 8, 10, 12, 14 Connector
    Accommodated in *2Accommodated in *1
    LT1, 3, 5, 7, 9, 11, 13, 15 ConnectorAccommodated in *3
    LT1, 3, 5, 7, 9, 11, 13, 15 Connector
    EFM
    Mounting ModulePIME
    1 231 231 23 1 231 231 23
    LT0LT1
    2425 LT14
    LT15
    12312
    HW3HW4HW5HW6HW7HW8HW9HW10 
    						
    							NDA-24282 (E) CHAPTER 4
    Page 153
    Revision 1.0
    PA-4DATB (DAT)
    7. Reference
    How to Record a Message
     Prior to your recording, set switches on the DAT card according to the following example.
    SWITCH SETTINGS ON DAT (Example )
     Connect a tape recorder to the DAT card with a cable.
     Turn On the MBRQ key to make busy a channel to be recorded.
    (To record a message in the 240 sec. mode, all circuits must be placed into MB state.)
     Turn the WR key upwards.
    (The corresponding BL lamp lights green indicating the tape recorder has been connected to the cir-
    cuit.)
     Turn the START key upwards.
    (The corresponding BL lamp starts flashing.)
     Start the tape recorder and record your message in the designated channel.
    
     The corresponding BL lamp (BL0 ~ BL7) lights steadily. (Recording ends.)
     Return the START, WR key to the previous position.
    SWITCH SETTING DESCRIPTION
    SW1
    SW4Timer Value for Channel 0-3: 240 sec.
    SW5 Circuit Card Timer: 60 sec. A-law/µ-law: A-law External Music Source/ An-
    nouncement Equipment: Announcement Equipment
    SW6 Single/Repeated Playback: Repeated Playback
    MRCS Channel Designation:
    240 sec mode
    DATFront
    Jack
    earphone jack (3.6 ø)Tape Recorder 
    						
    							CHAPTER 4 NDA-24282 (E)
    Pag e 1 54
    Revision 1.0
    PA-4DATB (DAT)
    How to Play Back the Recorded Message
     Playback from a telephone set
     Set the related switches on the PA-4DATB (DAT) card.
     Seize a specific channel by “Individual Trunk Access”.
     Hear the recorded message.
     Playback from the phone jack on PA-4DATB (DAT) card.
     Connect a earphone to the phone jack on the PA-4DATB (DAT) card.
     Select your desired channel (0~3) by the MRCS switch.
     Turn the START key upwards.
     Hear the recorded message. 
    						
    							NDA-24282 (E) CHAPTER 4
    Page 155
    Revision 1.0
    PA-4DTLA (4DTL)
    PA-4DTLA (4DTL)
    1. Function
    This circuit card is a trunk/line card that interfaces the NEAX2400 to four Data Modules.
    2. Mounting Location/Condition
    The mounting locations of this circuit card and the conditions related to mounting are shown below.
    (a) When this circuit card is mounted in PIMU-A
     
    NEAX2400IMS
    Navigator MIS
    Host
    4
    D
    T
    L
    A
    16
    E
    L
    C
    MDF
    Navigator Remote
    Terminal
    MDFDMDterm /Data
    AdapterData Terminal
    Equipment
    (DTE)
    01 02 03 04 05 06 07 08 09 10 11 12 13 14 15 16 17 18 19 20 21 22 23
    Mounting Module PIMU-A
    00
    Note:       Indicates that the slots are a universal slot for line/trunk circuit cards. 
      
    						
    							CHAPTER 4 NDA-24282 (E)
    Pag e 1 56
    Revision 1.0
    PA-4DTLA (4DTL)
    (b) When this circuit card is mounted in PIMB
     
    3. Face Layout of Lamps, Switches, and Connectors
    The face layout of lamps, switches, and connectors of this circuit card is shown below.
    Mounting Module PIMB
    01 02 03 04 05 06 07 08 09 10 11 12 13 14 15 16 17 18 19 20 21 22 23 00
    Note:      Indicates that the slots are a universal slot for line/trunk circuit cards. 
    OPE
    N-OPE
    MB
    BL3
    BL2
    BL1
    BL0 RFBS
    ECSL
    SW1
    SFBS
    RSBS
    SW0
    Front View Side View 
    						
    							NDA-24282 (E) CHAPTER 4
    Page 157
    Revision 1.0
    PA-4DTLA (4DTL)
    4. Lamp Indications
    The contents of lamp indications of this circuit card are shown in the table below.
    5. Switch Settings
    Standard settings of various switches on this circuit card are shown in the table below.
    LAMP NAME COLOR Status STATE
    OPE Green ON The Port Microprocessor is operating normally.
    N-OPE Red ON The Port Microprocessor is not operating due to MB switch or software.
    BL0
    BL3RedON The circuit is in use.
    Blinking 
    (1/sec.)The circuit is out of service due to switch setting or software.
    SWITCH 
    TYPE AND 
    NAMEFUNCTIONSWITCH
    ELEMENT POSITION MEANING
    Toggle Switch
    MBMake Busy (entire
    circuit card)  UP Take circuit card out of service.
    DOWN Normal operation.
    “Piano” keys 
    MB0 ~ MB3Busy out individual 
    circuits0 ~ 3UP (left) Normal operation.
    DOWN (right)Take corresponding circuit out of ser-
    vice.
    Dip Switch
    SW01 ~ 4 Must be ON
    DIP Switch
    RFBSReceived framing bit 
    control1 ~ 4
    Note
    ON Firmware control; DSR always ON.
    OFFHardware control; DSR set by DTE 
    (standard setting).
    DIP Switch
    SFBSSent framing bit
    control1 ~ 4
    Note
    ON Firmware control; DSR always ON.
    OFFHardware control; DSR set by DTE 
    (standard setting).
    DIP Switch 
    RSBSNot used 1 ~ 4 OFF(Standard setting.)
    DIP Switch 
    ECSLNot used 1 ~ 4 OFF(Standard setting.)
    Note:Each switch element (1 ~ 4) controls the corresponding circuit (0 ~ 3).
    ~ 
    						
    							CHAPTER 4 NDA-24282 (E)
    Pag e 1 58
    Revision 1.0
    PA-4DTLA (4DTL)
    6. External Interface
    Accommodation of the LT connector leads of this circuit card and connecting route diagram are shown
    below.
    (a) LT Connector Lead Accommodation when this circuit card is mounted in PIMA
    Figure 4-17   LT Connector Leads Accommodation of PIMU-A (1/2)
    26 
    27 
    28 
    29 
    30 
    31 
    32 
    33 
    34 
    35 
    36 
    37 
    38 
    39 
    40 
    41 
    42 
    43 
    44 
    45 
    46 
    47 
    48 
    49 
    501 
    2 
    3 
    4 
    5 
    6 
    7 
    8 
    9 
    10 
    11 
    12 
    13 
    14 
    15 
    16 
    17 
    18 
    19 
    20 
    21 
    22 
    23 
    24 
    25  LT Connector Accommodation
    00 01 02 03 04 05 06 07 08 09 10 11 12 13 14 15 16 17 18 19 20 21 22 23
    LT0
    PWR
    PIMA LT Connector Name
    Slot No.
    LT1, 3, 5, 7, 9, 11 Connector
    Accommodated in *2
    Group No.
    LT1LT2LT3LT4LT5LT6LT7LT8LT9LT10LT11
    01 
    0003 
    0205 
    0407 
    0609 
    0811 
    1001 
    0003 
    0205 
    0407 
    0609 
    0811 
    1015 
    14 
    13 
    1219 
    18 
    17 
    1623 
    22 
    21 
    2015 
    14 
    13 
    1219 
    18 
    17 
    1623 
    22 
    21 
    20
    Highway Block01267834591011
    26 
    27 
    28 
    29 
    30 
    31 
    32 
    33 
    34 
    35 
    36 
    37 
    38 
    39 
    40 
    41 
    42 
    43 
    44 
    45 
    46 
    47 
    48 
    49 
    50 LT0, 2, 4, 6, 8, 10 Connector
    Accommodated in *1
    1 
    2 
    3 
    4 
    5 
    6 
    7 
    8 
    9 
    10 
    11 
    12 
    13 
    14 
    15 
    16 
    17 
    18 
    19 
    20 
    21 
    22 
    23 
    24 
    25 
    * 1
    PWR* 1 * 1 * 1 * 1 * 1
    * 2 * 2 * 2 * 2 * 2 * 2
    B00
    B10
    B01
    B11
    B02
    B12
    B03
    B13A00
    A10
    A01
    A11
    A02
    A12
    A03
    A13
    B00
    B10
    B01
    B11
    B02
    B12
    B03
    B13A00
    A10
    A01
    A11
    A02
    A12
    A03
    A13 
    						
    							NDA-24282 (E) CHAPTER 4
    Page 159
    Revision 1.0
    PA-4DTLA (4DTL)
    Figure 4-17  LT Connector Leads Accommodation of PIMU-A (2/2)
    LT Connector Accommodation
    26 
    27 
    28 
    29 
    30 
    31 
    32 
    33 
    34 
    35 
    36 
    37 
    38 
    39 
    40 
    41 
    42 
    43 
    44 
    45 
    46 
    47 
    48 
    49 
    50
    00 01 02 03 04 05 06 07 08 09 10 11 12 13 14 15 16 17 18 19 20 21 22 23
    LT0
    PWR
    PIMA LT Connector Name
    Slot No.
    LT1, 3, 5, 7, 9, 11 Connector
    Accommodated in *3
    1 
    2 
    3 
    4 
    5 
    6 
    7 
    8 
    9 
    10 
    11 
    12 
    13 
    14 
    15 
    16 
    17 
    18 
    19 
    20 
    21 
    22 
    23 
    24 
    25
    Group No.
    LT1LT2LT3LT4LT5LT6LT7LT8LT9LT10LT11
    01 
    0003 
    0205 
    0407 
    0609 
    0811 
    1001 
    0003 
    0205 
    0407 
    0609 
    0811 
    1015 
    14 
    13 
    1219 
    18 
    17 
    1623 
    22 
    21 
    2015 
    14 
    13 
    1219 
    18 
    17 
    1623 
    22 
    21 
    20
    Highway Block01267834591011
    PWR* 3 * 3 * 3 * 3 * 3 * 3
    B00
    B10
    B01
    B11
    B02
    B12
    B03
    B13A00
    A10
    A01
    A11
    A02
    A12
    A03
    A13 
    						
    							CHAPTER 4 NDA-24282 (E)
    Pag e 1 60
    Revision 1.0
    PA-4DTLA (4DTL)
    (b) LT Connector Lead Accommodation when this circuit card is mounted in PIMB
    Figure 4-18   LT Connector Leads Accommodation of PIMB (1/2)
    LT Connector Accommodation
    00 01 02 03 04 05 06 07 08 09 10 11 12 13 14 15 16 17 18 19 20 21 22 23
    LT0
    PIMB LT Connector Name
    Slot No.
    Group No.
    LT1LT2LT3LT4LT5LT7LT8LT9LT10
    03 
    0207 
    0611 
    1015 
    1419 
    1823 
    2215 
    14 
    13 
    1207 
    06 
    05 
    0415 
    14 
    13 
    1223 
    22 
    21 
    20
    Highway Block012678 
    934510 
    11
    LT6
    23 
    22 
    21 
    2007 
    06 
    05 
    0415 
    14 
    13 
    1223 
    22 
    21 
    20
    01 
    0005 
    0409 
    0813 
    1217 
    1621 
    2011 
    10 
    09 
    0803 
    02 
    01 
    0011 
    10 
    09 
    0819 
    18 
    17 
    16 19 
    18 
    17 
    1603 
    02 
    01 
    0011 
    10 
    09 
    0819 
    18 
    17 
    16
    03 
    02
    01 
    0007 
    06
    05 
    04
    8 
    910 
    11 4 
    56 
    7 2 
    3 0 
    1
    * 1 * 1 * 1 * 1 * 1 * 1
    * 2 * 2 * 2 * 2 * 2
    LT1, 3, 5, 7, 9, 11 Connector
    Accommodated in *2
    26 
    27 
    28 
    29 
    30 
    31 
    32 
    33 
    34 
    35 
    36 
    37 
    38 
    39 
    40 
    41 
    42 
    43 
    44 
    45 
    46 
    47 
    48 
    49 
    50 LT0, 2, 4, 6, 8, 10 Connector
    Accommodated in *1
    1 
    2 
    3 
    4 
    5 
    6 
    7 
    8 
    9 
    10 
    11 
    12 
    13 
    14 
    15 
    16 
    17 
    18 
    19 
    20 
    21 
    22 
    23 
    24 
    25 
    B00
    B10
    B01
    B11
    B02
    B12
    B03
    B13A00
    A10
    A01
    A11
    A02
    A12
    A03
    A13
    B00
    B10
    B01
    B11
    B02
    B12
    B03
    B13A00
    A10
    A01
    A11
    A02
    A12
    A03
    A1326 
    27 
    28 
    29 
    30 
    31 
    32 
    33 
    34 
    35 
    36 
    37 
    38 
    39 
    40 
    41 
    42 
    43 
    44 
    45 
    46 
    47 
    48 
    49 
    501 
    2 
    3 
    4 
    5 
    6 
    7 
    8 
    9 
    10 
    11 
    12 
    13 
    14 
    15 
    16 
    17 
    18 
    19 
    20 
    21 
    22 
    23 
    24 
    25  
    						
    							NDA-24282 (E) CHAPTER 4
    Page 161
    Revision 1.0
    PA-4DTLA (4DTL)
    Figure 4-18  LT Connector Leads Accommodation of  PIMB (2/2)
    LT Connector Accommodation
    00 01 02 03 04 05 06 07 08 09 10 11 12 13 14 15 16 17 18 19 20 21 22 23
    LT0
    PIMB LT Connector Name
    Slot No.
    Group No.
    LT1LT2LT3LT4LT5LT7LT8LT9LT10
    03 
    0207 
    0611 
    1015 
    1419 
    1823 
    2215 
    14 
    13 
    1207 
    06 
    05 
    0415 
    14 
    13 
    1223 
    22 
    21 
    20
    Highway Block012678 
    934510 
    11
    LT6
    23 
    22 
    21 
    2007 
    06 
    05 
    0415 
    14 
    13 
    1223 
    22 
    21 
    20
    01 
    0005 
    0409 
    0813 
    1217 
    1621 
    2011 
    10 
    09 
    0803 
    02 
    01 
    0011 
    10 
    09 
    0819 
    18 
    17 
    16 19 
    18 
    17 
    1603 
    02 
    01 
    0011 
    10 
    09 
    0819 
    18 
    17 
    16
    03 
    02
    01 
    0007 
    06
    05 
    04
    8 
    910 
    11 4 
    56 
    7 2 
    3 0 
    1
    * 3 * 3 * 3 * 3 * 3
    26 
    27 
    28 
    29 
    30 
    31 
    32 
    33 
    34 
    35 
    36 
    37 
    38 
    39 
    40 
    41 
    42 
    43 
    44 
    45 
    46 
    47 
    48 
    49 
    50 LT1, 3, 5, 7, 9, 11 Connector
    Accommodated in *3
    1 
    2 
    3 
    4 
    5 
    6 
    7 
    8 
    9 
    10 
    11 
    12 
    13 
    14 
    15 
    16 
    17 
    18 
    19 
    20 
    21 
    22 
    23 
    24 
    25 B00
    B10
    B01
    B11
    B02
    B12
    B03
    B13A00
    A10
    A01
    A11
    A02
    A12
    A03
    A13 
    						