    Have a look at the manual Lucent Technologies Definity Release 8.2 Atm Installation Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 413 Lucent Technologies manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.

    							DEFINITY ECS Release 8.2 ATM Installation,
    Upgrades, and Administration  555-233-124  Issue 1
    April 2000
    Installing a DEFINITY ECS ATM-PNC 
    3-5 Synchronization Installation and Testing 
    3
    Installing  and  testing  the sync hronization sp litter involves interrup ting  the DS1 
    sig nal p rovid ed  by the servic e p rovid er. Even thoug h the DS1 c irc uit p ac k should  
    b e d own less than 5 minutes, b efore removing  a working  T1/E1 sp an, c ontac t the 
    servic e p rovid er. Failure to notify the T1/E1 servic e p rovid er may result in:
    — The servic e p rovider loop ing  the T1/E1 sp an b ac k to the 
    sub sc rib er.
    — A sp an alarm b eing  d etec ted  at the c entral offic e and  the sp an 
    b eing  taken out of servic e, send ing  an AIS (b lue Alarm) to the 
    DEFINITY ECS. The sync hronization sig nal is nec essary for testing 
    eq uip ment and  c onnec tions.
    Splitter descriptions 
    Table 3-2 d esc rib es the 4 sp litter mod els and  their c ap ab ilities. The d rawings 
    show the sp litters and their c onnec tion p oints. Figure 3-5
     shows a sc hematic  of 
    the 2 jump er sets and  their c onnec tions for 401A, 402A, and  403A sync  sp litters.
    Table 3-2. Synchronization splitter models and attributes  
    Model T1/E1 Impedance Comcode Drawing Description/Application
    400A T1 100 W108217795Figure 3-1
    No ICSU c apab ility
    401A T1 100 W 108508078Figure 3-2
    Limited ICSU capability
    402A E1 120 W108508094Figure 3-3
    403A E1 75 W108508102Figure 3-4
    Continued on next page 
    						
    							DEFINITY ECS Release 8.2 ATM Installation,
    Upgrades, and Administration  555-233-124  Issue 1
    April 2000
    Installing a DEFINITY ECS ATM-PNC 
    3-6 Synchronization Installation and Testing 
    3
    Figure 3-1. 400A synchronization splitter Figure Notes:
    1. From network interface
    2. Amp henol c onnec tion to 
    DEFINITY ECS 3. Timing  outp ut p ort (J1) to the ATM switc h1
    4. Timing  outp ut p ort (J2) to the ATM switc h1
    1. Ports J1 and  J2 p rovid e id entical DS1 timing  source sig nals to the ATM switc hes. 
    The ATM switc h can use two sep arate DS1 timing  signals (one at a time from two 
    sep arate spans).
    J1
    J2
    crda400a LJK 071698
    1
    2
    34 
    						
    							DEFINITY ECS Release 8.2 ATM Installation,
    Upgrades, and Administration  555-233-124  Issue 1
    April 2000
    Installing a DEFINITY ECS ATM-PNC 
    3-7 Synchronization Installation and Testing 
    3
    Figure 3-2. 401A synchronization splitter Figure Notes:
    1. Amp henol c onnec tor to 
    DEFINITY ECS
    2. Network timing  c onnec tion3. Timing  alarm lead  c onnec tion
    4. Timing  outp ut p orts (RJ45) to ATM switch
    1
    5. Jump ers and  c ap ac itors (insid e c ase). See 
    Figure 3-5 for setting s.
    1. Ports J1 and  J2 p rovid e id entical DS1 timing  source sig nals to the ATM switc hes. 
    The ATM switc h can use two sep arate DS1 timing  signals (one at a time from two 
    sep arate spans).
    401A
    108508078
    1
    0
    0O
    H
    MT
    1
    S
    Y
    N
    CS
    P
    L
    IT
    T
    E
    R
    TO ATM SWITCH NETWORKALARM
    Lucent
    Technologies
    crda401a KLC 020300
    1
    2
    3
    4
    TO DEFINITY
    5
    5 
    						
    							DEFINITY ECS Release 8.2 ATM Installation,
    Upgrades, and Administration  555-233-124  Issue 1
    April 2000
    Installing a DEFINITY ECS ATM-PNC 
    3-8 Synchronization Installation and Testing 
    3
    Figure 3-3. 402A synchronization splitter Figure Notes:
    1. Amp henol c onnec tor to 
    DEFINITY ECS
    2. Network timing  c onnec tion3. Timing  alarm lead  c onnec tion
    4. Timing  outp ut p orts (RJ45) to ATM switch
    1
    5. Jump ers and  c ap ac itors (insid e c ase). See 
    Figure 3-5 for setting s.
    1. Ports J1 and  J2 p rovid e id entical DS1 timing  source sig nals to the ATM switc hes. 
    The ATM switc h can use two sep arate DS1 timing  signals (one at a time from two 
    sep arate spans).
    402A
    108508094
    1
    2
    0O
    H
    ME
    1
    S
    Y
    N
    CS
    P
    L
    IT
    T
    E
    R
    TO ATM SWITCH NETWORKALARM
    Lucent
    Technologies
    crda402a KLC 020300
    1
    2
    3
    4
    TO DEFINITY
    5
    5 
    						
    							DEFINITY ECS Release 8.2 ATM Installation,
    Upgrades, and Administration  555-233-124  Issue 1
    April 2000
    Installing a DEFINITY ECS ATM-PNC 
    3-9 Synchronization Installation and Testing 
    3
    Figure 3-4. 403A synchronization splitter Figure Notes:
    1. Amp henol c onnec tor to DEFINITY 
    EC S
    2. Sync hronization source (timing  
    outp ut p orts) to ATM switc h
    1
    3. Sync hronization source (timing  
    outp ut p orts) to ATM switc h1
    1. These are id entic al DS1 timing source signals to the ATM switches. The ATM switc h 
    can use two separate DS1 timing  sig nals (one at a time from two sep arate sp ans).4. Network receive c onnection, BNC 
    connec tor
    5. Network transmit c onnection, BNC 
    connec tor
    6. Jump ers and  cap ac itors (inside c ase). 
    See  Figure 3-5
     for setting s.
    403A
    108508102
    75OHM E1
    SYNC SPLITTER
    TO ATM
    SWITCH RXTX
    Lucent Technologies
    NETWORK
    TO DEFINITY
    2
    3
    4
    5
    6
    6
    crda403a KLC 020300
    1 
    						
    							DEFINITY ECS Release 8.2 ATM Installation,
    Upgrades, and Administration  555-233-124  Issue 1
    April 2000
    Installing a DEFINITY ECS ATM-PNC 
    3-10 Synchronization Installation and Testing 
    3
    Figure 3-5. Jumper settings (401A/402A/403A) Figure Notes:
    1. Amp henol c onnec tion to DEFINITY 
    EC S sw i t c h
    2. Row of c ap acitors
    3. Jumpers for incoming network 
    c onnec tions
    4. Incoming network transmit and 
    receive connections
    5. Jumper 1-2 =  true g round
    Jumper 5-6 =  shield  ground ed
    Jumper 3 =  TX cab le g round
    Jump er 4 =  RX c ab le g round
    Default c onnec tions =  1-2, 3-56. True g round
    7. Cab le shield g rounded
    8. Jumper 1-2 =  true g round
    Jumper 5-6 =  shield  ground ed
    Jumper 3 =  ATM switc h A TX cab le ground
    Jumper 4 =  ATM switc h B TX cab le ground
    Default c onnec tions =  3-5, 4-6
    9. Outp ut jump ers
    10. Timing  outp ut to ATM switc h A
    11. Timing  outp ut to ATM switc h B
    1
    2
    8
    7
    2
    1 43 65
    TX
    TX
    5
    jpda40xa KLC 020300
    402A
    108508094
    120 OHM E1
    SYNC SPLITTER
    TO ATM SWITCH
    TO DEFINITY
    NETWORKALARM
    3
    6
    2
    1 43 65
    TX
    RX
    4 
    						
    							DEFINITY ECS Release 8.2 ATM Installation,
    Upgrades, and Administration  555-233-124  Issue 1
    April 2000
    Installing a DEFINITY ECS ATM-PNC 
    3-11 Synchronization Installation and Testing 
    3
    Synchronization splitter connections
    The sp litter c onnec ts to a timing sourc e. Figure 3-6 shows the synchronization 
    c onnec tions throug h a DSU/CSU (400A), and  Figure 3-7
     shows the 
    sync hronization c onnec tions throug h an ICSU (400A). Figure 3-8
     shows the 
    sync hronization c onnec tions d irec tly to the timing  sourc e (401A, 402A, 403A).
    Figure 3-6. Synchronization connections through an external DSU/CSU 
    (400A
    ) Figure Notes:
    1. Pub lic  Switc hed  Telep hone 
    Network (PSTN)
    2. Main d istrib ution frame (MDF) or 
    smart jac k.
    3. Channel servic e unit (CSU)
    4. H600-307-GR2 c ab le
    5. 400A T1 (100 W) sp litter c onnec ts 
    to the DEFINITY ECS6. H600-383 quad  c able from sync  sp litter to ATM 
    switc h A 
    7. H600-383 quad  c able from sync  sp litter to ATM 
    switc h B (c ritic al reliab ility/ATM network 
    d up lic ation)
    8. Luc ent ATM switc h A
    9. Luc ent ATM switc h B (c ritic al reliab ility/ATM 
    network d up lic ation)
    cydaatm2 LJK 020100
    1
    3
    4
    5
    67
    2
    89 
    						
    							DEFINITY ECS Release 8.2 ATM Installation,
    Upgrades, and Administration  555-233-124  Issue 1
    April 2000
    Installing a DEFINITY ECS ATM-PNC 
    3-12 Synchronization Installation and Testing 
    3
    Use the information in Table 3-3 to d etermine the maximum c able run leng ths for 
    the configuration.
    Figure 3-7. Synchronization connections through an ICSU (400A) Figure Notes:
    1. Pub lic  Switc hed  Telep hone 
    Network (PSTN)
    2. Main Distribution Frame (MDF) or 
    smart jac k
    3. H600-383 q uad  c ab le
    4. 400A T1 (100 W) sp litter c onnec ted  
    to DEFINITY ECS5. H600-383 quad  c able from sync  sp litter to ATM 
    switc h A 
    6. H600-383 quad  c able from sync  sp litter to 
    d up lic ated  ATM switc h B (c ritic al reliab ility)
    7. Luc ent ATM switc h A
    8. Luc ent ATM switc h B (c ritic al reliab ility
    /ATM  
    network d up lic ation)
    9. ICSU
    cydaatm1 LJK 020100
    1
    2
    3
    56
    49
    78 
    						
    							DEFINITY ECS Release 8.2 ATM Installation,
    Upgrades, and Administration  555-233-124  Issue 1
    April 2000
    Installing a DEFINITY ECS ATM-PNC 
    3-13 Synchronization Installation and Testing 
    3
    Figure 3-8. Synchronization connections directly to timing source 
    (401A/402A/403A) Figure Notes:
    1. Pub lic  switc hed telep hone network 
    (PSTN )
    2. Main d istrib ution frame (MDF) or 
    smart jac k
    3. H600-383 q uad  c ab le
    4. 401A T1 (100 W) sp litter, 
    402A E1 (120 W) splitter, or 
    403A E1 (75 W) splitter c onnec ted 
    to DEFINITY ECS 5. H600-383 quad  c able from sync  sp litter to ATM 
    switc h A 
    6. H600-383 quad  c able from sync  sp litter to 
    d up lic ated  ATM switc h B (c ritic al reliab ility
    /ATM  
    network d up lic ation)
    7. Luc ent ATM switc h A
    8. Luc ent ATM switc h B (c ritic al reliab ility
    /ATM  
    network d up lic ation)
    cydaatm3 KLC 020200
    56
    3
    78
    4
    1
    2 
    						
    							DEFINITY ECS Release 8.2 ATM Installation,
    Upgrades, and Administration  555-233-124  Issue 1
    April 2000
    Installing a DEFINITY ECS ATM-PNC 
    3-14 Synchronization Installation and Testing 
    3
    Use the information in Table 3-3 to d etermine the maximum c able run leng ths for 
    the configuration.
    Table 3-3. Maximum cable lengths 
    Splitter Used in CableMaximum distance from 
    splitter to ATM switch
    400A
    T1
    100 W North Americ a
    (USA and  Canad a)H600-383
    1
    shield ed  
    twisted  p air
    1. Must have RJ45 connectors on each end .250 feet
    76 meters
    401A
    T1
    100 W North Americ a
    (USA and  Canad a)H600-383
    1
    shield ed  
    twisted  p air1310 feet
    2
    393 meters
    402A
    E1
    120 WSee Table 3-4
    120-W
    shield ed  
    twisted  p air1000 feet2
    305 meters
    2. The loss allowed  in the c able is 6 d B. Typ ical c ab les have losses of 0.6 dB/100 ft; 
    hence, 1000 feet may b e c onsid ered  a typ ical distanc e. Distanc e varies if cab les with 
    d ifferent losses are used . 403A
    E1
    75 WSee Table 3-4
    75-W 
    coaxial1000 feet2
    305 meters
    Continued on next page 
    						