Have a look at the manual Lucent Technologies Definity Release 8.2 Atm Installation Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 413 Lucent Technologies manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.
DEFINITY ECS Release 8.2 ATM Installation, Upgrades, and Administration 555-233-124 Issue 1 April 2000 Troubleshooting 6-27 Troubleshooting ATM-PNC 6 Screen 6-9. Screen output for display atm pnc 1 with end system identifiers Screen 6-10. Screen output for display atm pnc 2 with end system identifiers display atm pnc 1 ATM PNC Connection Number: 1 A - PNC Location: 01B02 Name: Address Format: E.164 ATM Private AFI: 45 E.164: 0001013035381053 HO-DSP: 00000000 ESI: 000000000011 SEL: 00 display atm pnc 2 ATM PNC Connection Number: 2 A - PNC Location: 02A01 Name: Address Format: E.164 ATM Private AFI: 45 E.164: 0001013035381053 HO-DSP: 00000000 ESI: 000000000012 SEL: 00
DEFINITY ECS Release 8.2 ATM Installation, Upgrades, and Administration 555-233-124 Issue 1 April 2000 Troubleshooting 6-28 Troubleshooting ATM-PNC 6 ATM signaling links Figure 6-2 shows the sig naling links in an ATM-PNC c onfig uration. Figure 6-2. ATM signaling linksFigure Notes 1 . D EFIN I TY EC S sw i t c h PPN /EPN 2. Telep hones 3. ATM switc h 4. Constant bit rate switched virtual c onnec tion (CBR-SVC)5. PNC ATM control link (PACL) 6. Exp ansion archang el link (EAL) 7. ATM sig naling PPN 1 2 4 5 6 cydarout LJK 020100 EPN 2EPN 1 2 2 1 1 7 3
DEFINITY ECS Release 8.2 ATM Installation, Upgrades, and Administration 555-233-124 Issue 1 April 2000 Troubleshooting 6-29 Troubleshooting ATM-PNC 6 Signaling sequences. Use the information in Table 6-10 to help determine trouble with ATM sig naling . Ab b reviations used in this tab le c orresp ond to those in Figure 6-2 . ATM switch administration Is the ATM switch administered correctly? To verify that a sp ec ific Luc ent ATM switc h was ad ministered c orrec tly, refer to the ap p rop riate referenc e g uid e. Table 6-10. ATM signaling sequences Signaling between the PPN and the EPN Call between EPN2 and EPN 3 1. TN2305/TN2306 c irc uit p ac k in the PPN establishes a variable b it-rate switched virtual connec tion (VBR-SVC) for DEFINITY ECS sig naling throug h the ATM switc h to ea c h EPN .Station g oes off hook in EPN2. CCMS messages sent over the already established EAL to c all p roc essing in t h e PPN . 2. TN2305/TN2306 c irc uit p ac k in the PPN estab lishes EAL and PACL links with eac h EPN within the ab ove VBR- SVC .Call Proc essing send s a messag e over the PACL to the TN2305/TN2306 c ircuit p ack in EPN2 to estab lish a c onnection to the TN2305/TN2306 c ircuit p ack in EPN 3. 3. Links c ome up TN2305/TN2306 c ircuit p ack in EPN2 send s an ATM sig naling messag e to the ATM switc h to estab lish a CBR-SVC link to the TN2305/TN2306 circuit pack in EPN3. 4. Call p roc essing in the PPN sends CCMS messag es to the station in EPN2 over the alread y-estab lished EA L . 5. Rep eat step s 2 through 4 for the EPN3 to EPN2 connection. Continued on next page
DEFINITY ECS Release 8.2 ATM Installation, Upgrades, and Administration 555-233-124 Issue 1 April 2000 Troubleshooting 6-30 Troubleshooting ATM-PNC 6 TN2305/TN2306 circuit pack Did the TN2305/TN2306 come up correctly? 1. Review the LED c ond itions for the TN2305/TN2306 (refer to the maintenanc e b ook for LED ind ic ations): nDo the TN2305/TN2306 LEDs ind ic ate a normal operational state (any of the following ): — Ac tive in the PPN — Stand b y in the PPN — Arc hang el mod e in the EPN — Stand b y in the EPN 2. If after c irc uit pac k insertion or a d emand reset: nDo the TN2305/TN2306 LEDs ind ic ate that it is b ooting ? nDo the TN2305/TN2306 LEDs ind ic ate it is d ownload ing its DSPs? nDo the TN2305/TN2306 LEDs ind ic ate that c irc uit p ac k is not c omp letely inserted ? nDo the TN2305/TN2306 LEDs ind ic ate a maintenanc e alarm? 3. Type list configuration carrier UUCC and press En t e r. See Screen 6-11 (1b ) and Screen 6-12 (2a). Screen 6-11. List configuration carrier 1b screen list configuration carrier 1b SYSTEM CONFIGURATION Board Assigned Ports Number Board Type Code Vintage u=unassigned t=tti p=psa 01B02 ATM PNC EI TN2305 HW02 FW007 01B04 DIGITAL LINE TN754C 000002 u u u u u u u u 01B05 ANALOG LINE TN746B 000010 u u u u u 06 u u u u u u u u u u 01B06 DID TRUNK TN753 000021 u u u u u u u u 01B07 MAINTENANCE/TEST TN771D 000006 u 02 03 04 01B08 CO TRUNK TN747B 000018 u u u u u u u u 01B09 BRI LINE TN556B 000003 u u u u u u u u u u u u u u u u u u u u u u u u 01B10 DS1 INTERFACE TN767C 000003 u u u u u u u u u u u u u u u u u u u u u u u u
DEFINITY ECS Release 8.2 ATM Installation, Upgrades, and Administration 555-233-124 Issue 1 April 2000 Troubleshooting 6-31 Troubleshooting ATM-PNC 6 Screen 6-12. List configuration carrier 2a screen nMake sure the TN2305/TN2306 c irc uit p ac k is shown in the c orrec t slot (c hec k the Board Number field ). nField s should have values as ind ic ated b elow: 4. If the TN2305/TN2306 is inserted and shows a vintag e numb er, typ e test board UUCSS and p ress En t e r; Screen 6-13 displays. Screen 6-13. Screen output for test board UUCSS Field Value Board Type ATM PNC EI VintageThe TN2305/TN2306 vintag e is split b etween the hardware and firmware vintag es. the hardware vintag e matches the lab el on the latc h, and the firmware numb er ind ic ates the firmware vintag e. If Vintage is no board, then either the circuit pack is in the incorrect slot or the circuit pack was not completely inserted. Reinsert circuit pack into correct slot. list configuration carrier 2a SYSTEM CONFIGURATION Board Assigned Ports Number Board Type Code Vintage u=unassigned t=tti p=psa 02A01 ATM PNC EI TN2305 HW02 FW007 02A09 DS1 INTERFACE TN767E 000004 u u u u u u u u u u u u u u u u u u u u u u u u 02A10 DIGITAL LINE TN754B 000016 u u u u u u u u 02A11 ANALOG LINE TN746B 000010 01 u u u u u u u u u u u u u u u 02A17 DIGITAL LINE TN754C 000002 u u u u u u u u test board 1b02 TEST RESULTS Port Maintenance Name Alt. Name Test No. Result Error Code 01B02 ATM-EI 316 PASS 01B02 ATM-EI 598 PASS 01B02 ATM-EI 1293 PASS 888 01B02 ATM-EI 241 PASS 01B02 ATM-EI 304 PASS 01B02 ATM-EI 1259 PASS
DEFINITY ECS Release 8.2 ATM Installation, Upgrades, and Administration 555-233-124 Issue 1 April 2000 Troubleshooting 6-32 Troubleshooting ATM-PNC 6 nTh e Result field should show PASS for eac h test numb er. If any of the tests fail, refer to the ATM-EI maintenanc e ob jec ts in DEFINITY ECS Maintenanc e for R8r. Possible causes 1. The TN2305/TN2306 c irc uit p ac k is in a slot d ifferent from the DEFINITY ad ministration. 2. The TN2305/TN2306 was not c omp letely inserted . ATM signaling architecture Troub leshooting interop erability b etween the DEFINITY ECS switc h and the ATM switc h involves understand ing the arc hitec ture of ATM sig naling (Figure 6-3 ). A Luc ent Cajun A500 is used to show this c onc ep t. Figure 6-3. ATM signaling architecture The following list shows the ATM-stack layers d iscussed in this sec tion: nPhysical layer nSONET/SDH layer nQ.SAAL (data link) layer nATM call control nCall processing (CaPro) Layer TN230X DEFINITY PPNDEFINITY EPNFiber Fiber iodatrb LJK 052899 A500 ATM call control Port boardsSwitch processor Switch fabric Q.93B Q.SAAL AT M SONET PhysicalQ.93B Q.SAAL AT M SONET PhysicalCaPro TN230X
DEFINITY ECS Release 8.2 ATM Installation, Upgrades, and Administration 555-233-124 Issue 1 April 2000 Troubleshooting 6-33 Troubleshooting ATM-PNC 6 Physical layer Is there an optical signal between the TN2305/TN2306 and the ATM switch? 1. Id entify the OC-3/STM-1 p orts on the ATM switc h that have DEFINITY p ort networks attac hed . nBe aware that c ustomers may use other p orts on the ATM switc h for ap p lic ations unrelated to DEFINITY (LAN traffic or multimed ia ap p lic ations, for examp les). nThese other applications may manifest themselves in the output of the troub leshooting c ommand s you run on the ATM switc h. DEFINITY p ort networks must be id entified by their ATM switc h p ort numb ers. NOTE: The following examples show DEFINITY p ort networks c onnec ted to ATM switc h p orts A1.1 and A1.2. 1.Does the TN2305/TN2306’s YELLOW LED flash 100 ms on and 100 ms off, indic ating a loss of sig nal on the fiber? Rec all that the TN2305/TN2306 d etec ts c ontinuity p rob lems with either the transmit (b ottom) or the rec eive (top ) fib ers. If the fib er shows a loss of signal, refer to the “ Fiber Fault Isolation Proc ed ure” in DEFINITY ECS Maintenanc e for R8r. 2. Is the ATM switc h port’s LED ind ic ating a loss of sig nal on the fib er? Note that the ATM switc h may d etec t c ontinuity p roblems only with the rec eive fib er; the state of the transmit fib er mig ht not b e d etec ted . 3. Refer to your ATM switc h’s q uic k referenc e g uid e for troub leshooting commands. Possible causes. Check the following list for possible c auses. nThe fib er is d isc onnec ted from the ATM switc h and /or the TN2305/TN2306 circuit pack. nThe transmit and rec eive fib ers are swap p ed at the ATM switc h or the TN2305/TN2306 c irc uit p ac k (b ut not b oth). nThere is a b reak in the fib er. nThe TN2305/TN2306 is not transmitting a c arrier (not inserted , not p owered , or not ad ministered ). See the ATM-EI or ATM-TRK maintenanc e ob jec ts in DEFINITY ECS Maintenanc e for R8r. nHard ware safety interloc ks on optic al transc eivers may c ut transmitter p ower if no c arrier is rec eived , so lac k of a rec eive c arrier c ould ind ic ate a transmitter p rob lem at the same end .
DEFINITY ECS Release 8.2 ATM Installation, Upgrades, and Administration 555-233-124 Issue 1 April 2000 Troubleshooting 6-34 Troubleshooting ATM-PNC 6 nThe ATM switc h d oes not rec og nize that a port c irc uit p ac k is in the slot. You may need to re-ad minister the ATM switc h p ort b oard s. Refer to your ATM switc h’s q uic k referenc e g uid e for further information. Recommended Action. 1. Plug in, swap , rep air, or rep lac e the fib er as nec essary. 2. Verify that the port c irc uit p ac k is c omp letely inserted . SONET/SDH layer Are SONET/SDH frames reaching the ATM switch? Is the ATM switch port’s LED indicating no cell traffic? nChec k the transmit and rec eive c ell c ount field s. Eac h field ’s values should b e inc reasing if the TN2305/TN2306 is ac tively send ing and rec eiving c ells to and from the ATM switc h. nChec k for SONET/SDH layer alarms, LOP, LUF, and so on. nIf neither field is inc reasing , the ATM switc h p ort may be d own. Verify that the ad min status is up . nIf the rec eive c ell c ount is inc reasing b ut the transmit c ell c ount is not inc reasing , this may b e b ec ause the p ort was ad ministered with no UNI signaling. Ensure that signaling is UNI3.1. nAlthoug h the error c ounters may not b e zero, they should not b e larg e either c omp ared with the rec eive and transmit c ell c ounters. If the c ounters are larg e and inc reasing , c hec k the fib er integ rity. Make sure the fib er p airs are sec urely p lugg ed into b oth the TN2305/TN2306 c irc uit p ac k and the ATM switc h. nIf the fib er has b een p ulled and reinserted as p art of fault diag nosis, the nonzero loss of sig nal error c ounter may b e c orrec t. Q.SAAL (data link) layer Are ATM signaling messages reaching the ATM switch Call Control? NOTE: If the TN2305/TN2306 c irc uit p ac k is not c onnec ted to the ATM switc h at the Q.SAAL p rotoc ol layer, then no rep ort is d isp layed . 1. If the port of interest is not c onfig ured for UNI sig naling , then the p ort was ad ministered for no UNI sig naling . Verify that sig naling is UNI3.1. 2. If the p ort of interest was ad ministered for UNI3.0 sig naling , verify that sig naling is UNI3.1. 3. Chec k to see if the TN2305/TN2306 c irc uit pac k is ac tively send ing and rec eiving Q.SAAL Protoc ol Data Units with the ATM switc h.
DEFINITY ECS Release 8.2 ATM Installation, Upgrades, and Administration 555-233-124 Issue 1 April 2000 Troubleshooting 6-35 Troubleshooting ATM-PNC 6 Q.93B (network) layer Are connection requests being received by ATM switch call control? NOTE: If there is no c onnec tion b etween the TN2305/TN2306 c irc uit p ac k and the ATM switc h at the Q.93B p rotoc ol layer, then no rep ort d isp lays. 1. Chec k the p ort of interest. If it is not c onfig ured for UNI sig naling , then the p ort was ad ministered for no UNI sig naling . Verify that sig naling is UNI3.1 2. The c onnec t, setup, and release message c ounters should b e a nonzero numb er if the ATM switc h is hand ling Q.93B p rotoc ol layer messag es sent b y the PPN and EPN. They may not inc rease during troub leshooting unless c alls are b eing mad e b ec ause the PPN initially sets up c ontrol c onnec tions to the PPN and then sets up talk p ath c onnec tions as needed. 3. Check to see if c onnections are being rejected. The error may be on the PPN p ort even thoug h the EPN p ort is the one misb ehaving and vic e versa. 4. Type display errors and press En t e r. 5. Set the Error List field to errors and Category field to PNC on the input sc reen (Screen 6-14 ) and p ress En t e r to display any c ause c od es (see Table 6-11 ) returned from the ATM network to a TN2305/TN2306 c irc uit p ac k on the PPN (and to a TN2305/TN2306 c irc uit p ac k on an EPN). This is suc c essful only if the links between the PPN and the EPN remain up so that the messag e from the EPN is log g ed. See the ATM-EI maintenanc e ob jec t in one of the following b ooks: nDEFINITY Enterp rise Communic ations Server Release 8 Maintenanc e for R8r
DEFINITY ECS Release 8.2 ATM Installation, Upgrades, and Administration 555-233-124 Issue 1 April 2000 Troubleshooting 6-36 Troubleshooting ATM-PNC 6 Screen 6-14. Error report Screen 6-15 shows the sc reen outp ut for the display errors command. Screen 6-15. Hardware error report—screen 9 In this examp le the errors that have ATM-NTWK for Name field and 1 for Aux Data field ind ic ate an error returned to the TN2305/TN2306 c irc uit p ac k from the ATM network. In this c ase, the Err Type field shows the cause code returned by the ATM network (see Table 6-11 ). In the earlier examp le, two c ause c od es (41 and 3) are reported from the ATM network. For more information ab out these c ause c od es and rep air information see the ATM-NTWK (ATM Network Error) maintenanc e ob jec t. display errors Page 1 of 1 SPE A ERROR REPORT The following options control which errors will be displayed. ERROR TYPES Error Type: Error List: errors REPORT PERIOD Interval: a From: / / : To: / / : EQUIPMENT TYPE ( Choose only one, if any, of the following ) Cabinet: Port Network: Board Number: Port: Category: pnc Extension: Trunk ( group/member ): / display errors Page 9 SPE A HARDWARE ERROR REPORT Port Mtce Alt Err Aux First Last Err Err Rt/ Al Ac Name Name Type Data Occur Occur Cnt Rt Hr St AT01A ATM-NTWK 41 1 11/12/16:59 12/09/15:10 14 0 0 n n AT01A ATM-NTWK 31 0 11/13/18:27 11/20/20:02 5 0 0 n n AT02A ATM-NTWK 0 0 11/13/18:45 11/13/18:45 1 0 0 n n AT02A ATM-NTWK 31 0 11/15/14:40 11/15/14:41 2 120 0 n n AT01B ATM-NTWK 31 0 11/16/17:39 11/16/17:39 1 0 0 n n AT01A ATM-NTWK 3 1 11/16/18:19 11/26/13:13 12 0 0 n n