Have a look at the manual Lucent Technologies Definity Release 8.2 Atm Installation Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 413 Lucent Technologies manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.
DEFINITY ECS Release 8.2 ATM Installation, Upgrades, and Administration 555-233-124 Issue 1 April 2000 Preparing for Installation and Upgrades 1-13 Determine ATM Switch Suitability 1 ATM switc h is more than one. If this is the c ase, the c alc ulator first attemp ts to d etermine if the ap p lic ation is feasib le d esp ite the transit traffic . If it is, it rep orts the feasibility as YES or PROBABLY . If not, it rep orts the feasib ility as UNKNOWN , req uiring sp ec ial eng ineering . Known limits of commonly used ATM switches Use the limits shown in Table 1-8 to d o your own c alc ulations. To make it easier as you use the c alc ulator, we sug g est that you 1. Selec t and c op y the values from the tab le in the sp read sheet. 2. Selec t the values on the samp le c alc ulation. 3. Select Edit > Paste Special with the transp ose option to p aste the values into the c alc ulator. NOTE: These limits are the b est we c ould d etermine at one time. For eac h switc h, the examp le shown is g enerally the b est you c an d o, assuming you b oug ht the maximum c onfig uration and you ad ministered it op timally for DEFINITY (whic h are not nec essarily the d efault setting s). Consult the switc h vend or for c onfirmation of c urrent limits.
DEFINITY ECS Release 8.2 ATM Installation, Upgrades, and Administration 555-233-124 Issue 1 April 2000 Preparing for Installation and Upgrades 1-14 Schedule Installation or Upgrade 1 A limit shown as 1000000 means that this ATM switc h has no ind ep endently d efined limit on this resourc e. Schedule Installation or Upgrade Sc hedule the installation or up g rad e with the Luc ent Tec hnolog ies Tec hnic al Support Organization (TSO) and NetCare® Professional Servic es (NPS). See ‘‘Where To Call for Tec hnic al Sup p ort’’ on p ag e -xi . Table 1-8. Known limits of commonly used ATM switches SwitchNumber of PP SVCs supportedNumber of PMP (roots) supportedNumber of PMP parties (leaves) supportedNumber of PMP endpoints (roots + leaves) supportedTo t a l number of SVCs (PP+PMP) supportedPer-port SVC limit (normally based on VCI range)Setups/s at
Installing a DEFINITY ECS ATM-CES 2-1 Equipment Installation 2 DEFINITY ECS Release 8.2 ATM Installation, Upgrades, and Administration 555-233-124 Issue 1 April 2000 2 Installing a DEFINITY ECS AT M - C E S This chapter d escrib es the p roced ures for installing a new DEFINITY ECS Release 8 ATM-CES The p roc ed ure is simp le in that you install the DEFINITY ECS then install the ATM switc h and the TN2305/TN2306 interfac e c irc uit p ac ks. Making it an ATM-CES is d one ad ministratively (refer to Chapter 5, ‘‘Administering ATM-PNC and ATM-CES’’). NOTE: ATM-CES works only with TN2305/TN2306 ATM interfac e c irc uit p ac ks. Equipment Installation To p rep are for a new DEFINITY ECS ATM-CES installation, you need to install the DEFINITY ECS first. For instruc tions on installing DEFINITY ECS, refer to the following installation b ooks: nDEFINITY Enterp rise Communic ations Server Release 8 Installation and Test for Multicarrier Cab inets nDEFINITY Enterp rise Communic ations Server Release 8 Installation and Test for Sing le-Carrier Cab inets nDEFINITY Enterp rise Communic ations Server Release 8 Installation, Up g rad es, and Ad d itions for Comp ac t Mod ular Cab inets Review the reliab ility c onfig urations for DEFINITY Release 8 ATM (refer to Figure 1-2 through Figure 1-4). The slot restric tions for a CES c onfig uration are similar to ISDN-PRI c irc uit pac ks. In PPNs and EPNs, ATM interfac e c irc uit pac ks c an oc c up y any available slot in a p ort c arrier.
DEFINITY ECS Release 8.2 ATM Installation, Upgrades, and Administration 555-233-124 Issue 1 April 2000 Installing a DEFINITY ECS ATM-CES 2-2 Equipment Installation 2 Follow the step s in Table 2-1 to ensure that nthe ap p licab le equip ment is installed correctly. nthe c ustomer’s c onfig uration is p rop erly rec ord ed (use worksheet in Appendix A, ‘‘Baselining the Customer’s Configuration’’ ). Table 2-1. General installation process ÖStep Action Description 1. Install DEFINITY ECS Refer to the appropriate installation book for your platform See ‘‘DEFINITY ECS configurations’’ on page 1-6 for connection schematics. 2. Install ATM switch(es) or access concentratorsRefer to your ATM switch’s quick reference guide. 3.Install ATM interface circuit packInsert the TN2305/TN2306 circuit pack(s) into the appropriate slot(s). 4.Route the fiber optic cables between the ATM switch and the DEFINITY PPN and EPNs.Follow the fiber pass-through procedure in the appropriate DEFINITY ECS installation book . !WA R N I N G : Be sure that the fiber optic cable is secured so that the door of the DEFINITY ECS switch does not pinch or bend the cable. For csi platform, see Figure 2-1 for a diagram of the NAA7 board that routes fiber optic cabling from the back of the switch to the front. 5.Connect the fiber optic cablesConnect the fiber optic cables to the ATM switch. NOTE: If the installation uses the customer’s existing fiber, you may need an ST-to-SC adapter (1 included in Fiber Pass-Through Kit). 6.Connect the fiber optic cables to the ATM interface circuit packsConnect fiber optic cable to the SC connector on the faceplate of each TN2305/TN2306 circuit pack in the DEFINITY PPN and EPN. nThe TN2305/TN2306 circuit pack interface requires SC connectors (see Note in Step 5). nDo not reuse existing fiber cabling with ST connectors at both the DEFINITY ECS and the ATM switch. This requires an ST-to-SC adapter at both ends. It is better to order the cable with the SC connectors at both ends. Continued on next page
DEFINITY ECS Release 8.2 ATM Installation, Upgrades, and Administration 555-233-124 Issue 1 April 2000 Installing a DEFINITY ECS ATM-CES 2-3 NAA7 Board (csi/c models only) 2 NAA7 Board (csi/c models only) The NAA7 board routes fib er optic c onnec tions from the rear of the c abinet throug h the front fac ep late as shown in Figure 2-1 . The SC fib er c onnec tors that g o throug h the fac ep late c onnec t to the fac ep late c onnec tors on the TN2305/TN2306 ATM c irc uit p ac k. Figure 2-1. NAA7 board (csi and c models only) 7. Record configuration Record DEFINITY ECS switch-to-ATM port (port locations for each ATM circuit pack) in Table A-1 in Appendix A, ‘‘Baselining the Customer’s Configuration’’. 8. Record fiber connectionsRecord the fiber optic cable runs on the lightwave interface (LIU) diagram ( Figure A-1 in Appendix A, ‘‘Baselining the Customer’s Configuration’’). Table 2-1. General installation process ÖStep Action Description Continued on next page A B A B ckdanaa1 LJK 021199 A B A B A B
DEFINITY ECS Release 8.2 ATM Installation, Upgrades, and Administration 555-233-124 Issue 1 April 2000 Installing a DEFINITY ECS ATM-CES 2-4 NAA7 Board (csi/c models only) 2
Installing a DEFINITY ECS ATM-PNC 3-1 Equipment Installation 3 DEFINITY ECS Release 8.2 ATM Installation, Upgrades, and Administration 555-233-124 Issue 1 April 2000 3 Installing a DEFINITY ECS AT M - P N C This chapter d escrib es the p roced ures for installing a new DEFINITY ECS Release 8 ATM system. The p roc ess inc lud es nEquipment Installation nSynchronization Installation and Testing nATM Network Duplication Equipment Installation If the ATM switc h and interfac e c irc uit p ac ks are alread y installed , then the ac tual up g rad e to ATM-PNC is d one ad ministratively in Chapter 5, ‘‘Administering ATM-PNC and ATM-CES’’. To p rep are for a new DEFINITY ECS ATM installation refer to the following b ooks: nDEFINITY Enterp rise Communic ations Server Release 8 Installation and Test for Multicarrier Cab inets nDEFINITY Enterp rise Communic ations Server Release 8 Installation and Test for Sing le-Carrier Cab inets Review the reliab ility c onfig urations for DEFINITY Release 8 ATM (refer to Figure 1-2 throug h Figure 1-4) and determine the sync hronization sourc es (DS1, E1, or ATM network).
DEFINITY ECS Release 8.2 ATM Installation, Upgrades, and Administration 555-233-124 Issue 1 April 2000 Installing a DEFINITY ECS ATM-PNC 3-2 Equipment Installation 3 Slot restric tions for an ATM interfac e c irc uit p ac ks are similar to exp ansion interfac e c irc uit p ac ks: nPPN: ATM interfac e c irc uit p ac ks used for ATM-PNC must oc c up y the slots labeled EXPANSION INTERFACE. nEPNs: ATM interfac e c irc uit pac ks used for ATM-PNC c an oc c up y slot 1 (and 2 if d up lic ated ) on c arrier A, and slot 2 (and 3 if d up lic ated ) on c arrier B Follow the step s in Table 3-1 to ensure that nthe ap p licab le equip ment is installed correctly. nthe c ustomer’s c onfig uration is p rop erly rec ord ed (use worksheet in Appendix A, ‘‘Baselining the Customer’s Configuration’’ ). Table 3-1. General installation process ÖStep Action Description 1. Install DEFINITY ECS switc hRefer to the ap propriate installation b ook Se e ‘‘DEFINITY ECS configurations’’ on page 1-6 for c onnec tion sc hematic s. 2. Install ATM switc h(es) or access c onc entratorsRefer to your ATM switch’s q uic k referenc e g uide. 3. Check the distances from the ATM switch to the DS1 timing sourceUse the information in Table 3-3 to d etermine the maximum c ab le run lengths for the c onfiguration for more information. 4. Install ATM interfac e circuit packInsert the TN2305/TN2306 circuit p ack(s) into the ap propriate slot(s). 5. Route the fib er op tic c ables b etween the ATM switc h and the DEFINITY PPN and EPN s.Follow the fib er p ass-throug h p roced ure in the app rop riate installation b ook. !WA R N I N G : Be sure that the fib er op tic cab le is secured so that the door of the DEFINITY ECS switc h does not p inc h or bend the c ab le. 6. Connec t the fib er op tic cab lesConnect the fib er op tic c ab les to the ATM switch. NOTE: If the installation uses the customer’s existing fib er, you may need an ST-to-SC ad ap ter (1 inc lud ed in Fib er Pass-Through Kit). Continued on next page
DEFINITY ECS Release 8.2 ATM Installation, Upgrades, and Administration 555-233-124 Issue 1 April 2000 Installing a DEFINITY ECS ATM-PNC 3-3 Synchronization Installation and Testing 3 Synchronization Installation and Te s t i n g A DEFINITY ATM-PNC req uires network sync hronization for DS1 c irc uit p ac ks not to slip relative to the LEC/IXC switc hes. The ATM switc h serves as the sync referenc e sourc e for the DEFINITY. The ATM switc h, in turn, d erives p rimary and sec ond ary sync . To ac c omp lish this, the most c ommon op tion is to use sync hronization exp and ers (sp litters). 7. Connec t the fib er op tic cab les to the ATM interfac e circuit packsConnect fiber op tic c ab le to the SC c onnec tor on the facep late of each TN2305/TN2306 c irc uit pac k in the DEFINITY PPN and EPN. nThe TN2305/TN2306 c irc uit p ac k interfac e req uires SC c onnec tors (see Note in Step 5). nDo not reuse existing fib er c abling with ST c onnec tors at b oth the DEFINITY switc h and the ATM switc h. This req uires an ST-to-SC ad ap ter at b oth end s. It is better to ord er the c able with the SC c onnec tors at b oth end s. 8. Rec ord config uration Record DEFINITY ECS switc h-to-ATM port (p ort loc ations for each ATM circuit p ack) in Table A-1 (in Appendix A, ‘‘Baselining the Customer’s Configuration’’). NOTE: Read the MAC ad d resses from the ATM switc h (refer to your ATM switc h’s quick referenc e g uid e) and rec ord them in Table A-1 . 9. Rec ord fib er c onnectionsRecord the fiber op tic c ab le runs on the lig htwave interface (LIU) d iag ram (Figure A-1 ) in Appendix A, ‘‘Baselining the Customer’s Configuration’’. 10. Install and test sync hronization sp litter, if required .Follow the p roc ed ures for installing and testing the synchronization splitter and the T1 or E1 timing sourc e in ‘‘Synchronization Installation and Testing’’ on page 3-3 . Table 3-1. General installation process ÖStep Action Description Continued on next page
DEFINITY ECS Release 8.2 ATM Installation, Upgrades, and Administration 555-233-124 Issue 1 April 2000 Installing a DEFINITY ECS ATM-PNC 3-4 Synchronization Installation and Testing 3 Connections without synchronization splitters In some c onfig urations the ATM switc hes are trac ed to network c loc ks throug h their SONET/SDH interfac es, not req uiring any sync hronization sp litters. However, the ATM switc h c ould require a sing le sp litter if only one of the sync sourc es is d erived from the network. The ATM switc hes may obtain their network sync hronization as follows: nThe ATM switc h g ets its network timing referenc e from its SONET/SDH/SDIT interfac e to that network. nOr if the c ustomer wants to use a DS1 sourc e for network sync hronization that also hap p ens to b e a DEFINITY ECS switc h trunk, then one sync sp litter is nec essary to send a c op y of that DS1 sig nal to the ATM switc h. The DS1 c irc uit p ac k is only an ind irec t timing referenc e for the DEFINITY EC S sw it c h . Connections needing synchronization splitters If the ATM network d oes not p rovid e a sync hronization exp and er (sp litter), then the ATM c onfig urations may req uire one that takes a DS1 T1 or E1 signal and red irec ts it to the nATM switc h(es), d epend ing on c onfig uration and d up lic ation nDEFINITY ECS throug h the DS1 c irc uit pac k This c reates a sing le sync hronization sourc e. Chec k the c ustomer’s c onfiguration c arefully so that you c an nConnec t the hardware c orrec tly d uring installation nProp erly ad minister the sync hronization p lan later (Chapter 5, ‘‘Administering ATM-PNC and ATM-CES’’) This sec tion c overs the sync hronization installation and test p roc ess. nSplitter descriptions—Desc rib es the sp litter’s inp uts and outp uts nSynchronization splitter connections—Connec tion d iag rams for timing c onnec tions throug h a DSU/CSU (Figure 3-6 ) and an ICSU (Figure 3-7) nVerify the DS1 service—Chec ks for p resenc e of the DS1 T1 or E1 timing sourc e and the g eneral health of the DS1 c irc uit p ac k. nInstalling and testing the splitter provid es the following information —Splitter port tests (401A/401A only) —Installing a 400A T1 splitter —Installing 401A, 402A, or 403A splitters