    Have a look at the manual Lucent Technologies Definity Release 8.2 Atm Installation Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 413 Lucent Technologies manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.

    							DEFINITY ECS Release 8.2 ATM Installation,
    Upgrades, and Administration  555-233-124  Issue 1
    April 2000
    Preparing for Installation and Upgrades 
    1-13 Determine ATM Switch Suitability 
    1
    ATM switc h is more than one. If this is the c ase, the c alc ulator first attemp ts to 
    d etermine if the ap p lic ation is feasib le d esp ite the transit traffic . If it is, it rep orts 
    the feasibility as YES
     or PROBABLY
    . If not, it rep orts the feasib ility as 
    UNKNOWN
    , req uiring  sp ec ial eng ineering .
    Known limits of commonly used ATM switches
    Use the limits shown in Table 1-8 to d o your own c alc ulations. To make it easier 
    as you use the c alc ulator, we sug g est that you
    1. Selec t and  c op y the values from the tab le in the sp read sheet.
    2. Selec t the values on the samp le c alc ulation.
    3. Select Edit > Paste Special
     with the transp ose option to p aste the values 
    into the c alc ulator.
    NOTE:
    These limits are the b est we c ould  d etermine at one time. For eac h switc h, 
    the examp le shown is g enerally the b est you c an d o, assuming you b oug ht 
    the maximum c onfig uration and  you ad ministered  it op timally for DEFINITY 
    (whic h are not nec essarily the d efault setting s). Consult the switc h vend or 
    for c onfirmation of c urrent limits. 
    						
    							DEFINITY ECS Release 8.2 ATM Installation,
    Upgrades, and Administration  555-233-124  Issue 1
    April 2000
    Preparing for Installation and Upgrades 
    1-14 Schedule Installation or Upgrade 
    1
    A limit shown as 1000000 means that this ATM switc h has no ind ep endently 
    d efined  limit on this resourc e.
    Schedule Installation or Upgrade
    Sc hedule the installation or up g rad e with the Luc ent Tec hnolog ies Tec hnic al 
    Support Organization (TSO) and NetCare®  Professional Servic es (NPS). See 
    ‘‘Where To Call for Tec hnic al Sup p ort’’ on p ag e -xi
    .
    Table 1-8. Known limits of commonly used ATM switches
    SwitchNumber 
    of PP 
    SVCs 
    supportedNumber 
    of PMP 
    (roots) 
    supportedNumber 
    of PMP 
    parties 
    (leaves) 
    supportedNumber 
    of PMP 
    endpoints 
    (roots + 
    leaves) 
    supportedTo t a l  
    number 
    of SVCs 
    (PP+PMP) 
    supportedPer-port 
    SVC limit 
    (normally 
    based on 
    VCI 
    range)Setups/s 
    at 
    
    						
    							Installing a DEFINITY ECS ATM-CES 
    2-1 Equipment Installation 
    2
    DEFINITY ECS Release 8.2 ATM Installation,
    Upgrades, and Administration  555-233-124  Issue 1
    April 2000
    2
    Installing a DEFINITY ECS
    AT M - C E S
    This chapter d escrib es the p roced ures for installing  a new DEFINITY ECS 
    Release 8 ATM-CES The p roc ed ure is simp le in that you install the DEFINITY ECS 
    then install the ATM switc h and the TN2305/TN2306 interfac e c irc uit p ac ks. 
    Making  it an ATM-CES is d one ad ministratively (refer to Chapter 5, ‘‘Administering 
    ATM-PNC and ATM-CES’’).
    NOTE:
    ATM-CES works only with TN2305/TN2306 ATM interfac e c irc uit p ac ks.
    Equipment Installation
    To p rep are for a new DEFINITY ECS ATM-CES installation, you need  to install the 
    DEFINITY ECS first. For instruc tions on installing  DEFINITY ECS, refer to the 
    following  installation b ooks:
    nDEFINITY Enterp rise Communic ations Server Release 8 Installation and  
    Test for Multicarrier Cab inets
    nDEFINITY Enterp rise Communic ations Server Release 8 Installation and  
    Test for Sing le-Carrier Cab inets
    nDEFINITY Enterp rise Communic ations Server Release 8 Installation, 
    Up g rad es, and Ad d itions for Comp ac t Mod ular Cab inets
    Review the reliab ility c onfig urations for DEFINITY Release 8 ATM (refer to Figure 
    1-2 through Figure 1-4).
    The slot restric tions for a CES c onfig uration are similar to ISDN-PRI c irc uit pac ks. 
    In PPNs and  EPNs, ATM interfac e c irc uit pac ks c an oc c up y any available slot in 
    a p ort c arrier. 
    						
    							DEFINITY ECS Release 8.2 ATM Installation,
    Upgrades, and Administration  555-233-124  Issue 1
    April 2000
    Installing a DEFINITY ECS ATM-CES 
    2-2 Equipment Installation 
    2
    Follow the step s in Table 2-1 to ensure that
    nthe ap p licab le equip ment is installed  correctly.
    nthe c ustomer’s c onfig uration is p rop erly rec ord ed  (use worksheet in 
    Appendix A, ‘‘Baselining the Customer’s Configuration’’
    ). 
    Table 2-1. General installation process
    ÖStep Action Description
    1. Install DEFINITY ECS Refer to the appropriate installation book for your platform
    See 
    ‘‘DEFINITY ECS configurations’’ on page 1-6 for 
    connection schematics.
    2. Install ATM switch(es)
    or access 
    concentratorsRefer to your ATM switch’s quick reference guide.
    3.Install ATM interface 
    circuit packInsert the TN2305/TN2306 circuit pack(s) into the 
    appropriate slot(s).
    4.Route the fiber optic 
    cables between the 
    ATM switch and the 
    DEFINITY PPN and 
    EPNs.Follow the fiber pass-through procedure in the appropriate 
    DEFINITY ECS installation book
    .
    !WA R N I N G :
    Be sure that the fiber optic cable is secured so that 
    the door of the DEFINITY ECS switch does not pinch 
    or bend the cable.
    For csi platform, see Figure 2-1 for a diagram of the NAA7 
    board that routes fiber optic cabling from the back of the 
    switch to the front.
    5.Connect the fiber 
    optic cablesConnect the fiber optic cables to the ATM switch.
    NOTE:
    If the installation uses the customer’s existing fiber, 
    you may need an ST-to-SC adapter (1 included in 
    Fiber Pass-Through Kit).
    6.Connect the fiber 
    optic cables to the 
    ATM interface circuit 
    packsConnect fiber optic cable to the SC connector on the 
    faceplate of each TN2305/TN2306 circuit pack in the 
    DEFINITY PPN and EPN.
    nThe TN2305/TN2306 circuit pack interface requires SC 
    connectors (see Note in Step 5).
    nDo not reuse existing fiber cabling with ST connectors 
    at both the DEFINITY ECS and the ATM switch. This 
    requires an ST-to-SC adapter at both ends. It is better 
    to order the cable with the SC connectors at both ends.
    Continued on next page 
    						
    							DEFINITY ECS Release 8.2 ATM Installation,
    Upgrades, and Administration  555-233-124  Issue 1
    April 2000
    Installing a DEFINITY ECS ATM-CES 
    2-3 NAA7 Board (csi/c models only) 
    2
    NAA7 Board (csi/c models only)
    The NAA7 board  routes fib er optic  c onnec tions from the rear of the c abinet 
    throug h the front fac ep late as shown in Figure 2-1
    . The SC fib er c onnec tors that 
    g o throug h the fac ep late c onnec t to the fac ep late c onnec tors on the 
    TN2305/TN2306 ATM c irc uit p ac k.
    Figure 2-1. NAA7 board (csi and c models only)
    7. Record configuration Record DEFINITY ECS switch-to-ATM port (port locations 
    for each ATM circuit pack) in 
    Table A-1 in Appendix A, 
    ‘‘Baselining the Customer’s Configuration’’.
    8. Record fiber 
    connectionsRecord the fiber optic cable runs on the lightwave interface 
    (LIU) diagram (
    Figure A-1 in Appendix A, ‘‘Baselining 
    the Customer’s Configuration’’).
    Table 2-1. General installation process
    ÖStep Action Description
    Continued on next page
    A
    B
    A
    B
    ckdanaa1 LJK 021199
    A
    B
    A B
    A B 
    						
    							DEFINITY ECS Release 8.2 ATM Installation,
    Upgrades, and Administration  555-233-124  Issue 1
    April 2000
    Installing a DEFINITY ECS ATM-CES 
    2-4 NAA7 Board (csi/c models only) 
    2 
    						
    							Installing a DEFINITY ECS ATM-PNC 
    3-1 Equipment Installation 
    3
    DEFINITY ECS Release 8.2 ATM Installation,
    Upgrades, and Administration  555-233-124  Issue 1
    April 2000
    3
    Installing a DEFINITY ECS
    AT M - P N C
    This chapter d escrib es the p roced ures for installing  a new DEFINITY ECS 
    Release 8 ATM system. The p roc ess inc lud es
    nEquipment Installation
    nSynchronization Installation and Testing
    nATM Network Duplication
    Equipment Installation
    If the ATM switc h and  interfac e c irc uit p ac ks are alread y installed , then the ac tual 
    up g rad e to ATM-PNC is d one ad ministratively in Chapter 5, ‘‘Administering 
    ATM-PNC and ATM-CES’’.
    To p rep are for a new DEFINITY ECS ATM installation refer to the following  b ooks:
    nDEFINITY Enterp rise Communic ations Server Release 8 Installation and  
    Test for Multicarrier Cab inets
    nDEFINITY Enterp rise Communic ations Server Release 8 Installation and  
    Test for Sing le-Carrier Cab inets
    Review the reliab ility c onfig urations for DEFINITY Release 8 ATM (refer to 
    Figure 
    1-2 throug h Figure 1-4) and  determine the sync hronization sourc es (DS1, E1, or 
    ATM network). 
    						
    							DEFINITY ECS Release 8.2 ATM Installation,
    Upgrades, and Administration  555-233-124  Issue 1
    April 2000
    Installing a DEFINITY ECS ATM-PNC 
    3-2 Equipment Installation 
    3
    Slot restric tions for an ATM interfac e c irc uit p ac ks are similar to exp ansion 
    interfac e c irc uit p ac ks:
    nPPN: ATM interfac e c irc uit p ac ks used  for ATM-PNC must oc c up y the slots 
    labeled EXPANSION INTERFACE.
    nEPNs: ATM interfac e c irc uit pac ks used  for ATM-PNC c an oc c up y slot 1 
    (and  2 if d up lic ated ) on c arrier A, and  slot 2 (and  3 if d up lic ated ) on c arrier 
    B
    Follow the step s in Table 3-1
     to ensure that
    nthe ap p licab le equip ment is installed  correctly.
    nthe c ustomer’s c onfig uration is p rop erly rec ord ed  (use worksheet in 
    Appendix A, ‘‘Baselining the Customer’s Configuration’’
    ).
    Table 3-1. General installation process
    ÖStep Action Description
    1. Install DEFINITY ECS 
    switc hRefer to the ap propriate installation b ook
    Se e ‘‘DEFINITY ECS configurations’’ on page 1-6
     for 
    c onnec tion sc hematic s.
    2. Install ATM switc h(es)
    or access 
    c onc entratorsRefer to your ATM switch’s q uic k referenc e g uide.
    3. Check the distances 
    from the ATM switch 
    to the DS1 timing  
    sourceUse the information in Table 3-3
     to d etermine the 
    maximum c ab le run lengths for the c onfiguration for more 
    information.
    4. Install ATM interfac e 
    circuit packInsert the TN2305/TN2306 circuit p ack(s) into the 
    ap propriate slot(s).
    5. Route the fib er op tic  
    c ables b etween the 
    ATM switc h and the 
    DEFINITY PPN and 
    EPN s.Follow the fib er p ass-throug h p roced ure in the app rop riate 
    installation b ook.
    !WA R N I N G :
    Be sure that the fib er op tic  cab le is secured so that 
    the door of the DEFINITY ECS switc h does not p inc h 
    or bend the c ab le.
    6. Connec t the fib er 
    op tic  cab lesConnect the fib er op tic  c ab les to the ATM switch.
    NOTE:
    If the installation uses the customer’s existing  fib er, 
    you may need an ST-to-SC ad ap ter (1 inc lud ed  in 
    Fib er Pass-Through Kit).
    Continued on next page 
    						
    							DEFINITY ECS Release 8.2 ATM Installation,
    Upgrades, and Administration  555-233-124  Issue 1
    April 2000
    Installing a DEFINITY ECS ATM-PNC 
    3-3 Synchronization Installation and Testing 
    3
    Synchronization Installation and 
    Te s t i n g
    A DEFINITY ATM-PNC req uires network sync hronization for DS1 c irc uit p ac ks not 
    to slip  relative to the LEC/IXC switc hes. The ATM switc h serves as the sync  
    referenc e sourc e for the DEFINITY. The ATM switc h, in turn, d erives p rimary and  
    sec ond ary sync . To ac c omp lish this, the most c ommon op tion is to use 
    sync hronization exp and ers (sp litters).
    7. Connec t the fib er 
    op tic  cab les to the 
    ATM interfac e circuit 
    packsConnect fiber op tic c ab le to the SC c onnec tor on the 
    facep late of each TN2305/TN2306 c irc uit pac k in the 
    DEFINITY PPN and  EPN.
    nThe TN2305/TN2306 c irc uit p ac k interfac e req uires SC 
    c onnec tors (see Note in Step  5).
    nDo not reuse existing  fib er c abling  with ST c onnec tors 
    at b oth the DEFINITY switc h and the ATM switc h. This 
    req uires an ST-to-SC ad ap ter at b oth end s. It is better 
    to ord er the c able with the SC c onnec tors at b oth 
    end s.
    8. Rec ord  config uration Record DEFINITY ECS switc h-to-ATM port (p ort loc ations 
    for each ATM circuit p ack) in Table A-1
     (in Appendix A, 
    ‘‘Baselining the Customer’s Configuration’’). 
    NOTE:
    Read  the MAC ad d resses from the ATM switc h (refer 
    to your ATM switc h’s quick referenc e g uid e) and  
    rec ord  them in Table A-1
    .
    9. Rec ord  fib er 
    c onnectionsRecord the fiber op tic c ab le runs on the lig htwave 
    interface (LIU) d iag ram (Figure A-1
    ) in Appendix A, 
    ‘‘Baselining the Customer’s Configuration’’.
    10. Install and  test 
    sync hronization 
    sp litter, if required .Follow the p roc ed ures for installing  and  testing  the 
    synchronization splitter and  the T1 or E1 timing  sourc e in 
    ‘‘Synchronization Installation and Testing’’ on page 3-3
    .
    Table 3-1. General installation process
    ÖStep Action Description
    Continued on next page 
    						
    							DEFINITY ECS Release 8.2 ATM Installation,
    Upgrades, and Administration  555-233-124  Issue 1
    April 2000
    Installing a DEFINITY ECS ATM-PNC 
    3-4 Synchronization Installation and Testing 
    3
    Connections without synchronization splitters
    In some c onfig urations the ATM switc hes are trac ed  to network c loc ks throug h 
    their SONET/SDH interfac es, not req uiring  any sync hronization sp litters. 
    However, the ATM switc h c ould  require a sing le sp litter if only one of the sync  
    sourc es is d erived  from the network.
    The ATM switc hes may obtain their network sync hronization as follows:
    nThe ATM switc h g ets its network timing  referenc e from its 
    SONET/SDH/SDIT interfac e to that network.
    nOr if the c ustomer wants to use a DS1 sourc e for network sync hronization 
    that also hap p ens to b e a DEFINITY ECS switc h trunk, then one sync  
    sp litter is nec essary to send  a c op y of that DS1 sig nal to the ATM switc h. 
    The DS1 c irc uit p ac k is only an ind irec t timing  referenc e for the DEFINITY 
    EC S sw it c h .  
    Connections needing synchronization splitters
    If the ATM network d oes not p rovid e a sync hronization exp and er (sp litter), then 
    the ATM c onfig urations may req uire one that takes a DS1 T1 or E1 signal and  
    red irec ts it to the
    nATM switc h(es), d epend ing  on c onfig uration and  d up lic ation
    nDEFINITY ECS throug h the DS1 c irc uit pac k
    This c reates a sing le sync hronization sourc e. 
    Chec k the c ustomer’s c onfiguration c arefully so that you c an
    nConnec t the hardware c orrec tly d uring  installation
    nProp erly ad minister the sync hronization p lan later (Chapter 5, 
    ‘‘Administering ATM-PNC and ATM-CES’’)
    This sec tion c overs the sync hronization installation and test p roc ess.
    nSplitter descriptions—Desc rib es the sp litter’s inp uts and  outp uts
    nSynchronization splitter connections—Connec tion d iag rams for timing  
    c onnec tions throug h a DSU/CSU (Figure 3-6
    ) and  an ICSU (Figure 3-7)
    nVerify the DS1 service—Chec ks for p resenc e of the DS1 T1 or E1 timing 
    sourc e and  the g eneral health of the DS1 c irc uit p ac k. 
    nInstalling and testing the splitter provid es the following  information
    —Splitter port tests (401A/401A only)
    —Installing a 400A T1 splitter
    —Installing 401A, 402A, or 403A splitters 
    						