    Have a look at the manual Lucent Technologies Definity Release 8.2 Atm Installation Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 413 Lucent Technologies manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.

    							DEFINITY ECS Release 8.2 ATM Installation,
    Upgrades, and Administration  555-233-124  Issue 1
    April 2000
    Troubleshooting 
    6-47 Troubleshooting ATM-PNC 
    6
    Field descriptions:
    2. The ATM PNC Delayed /Failed  Setup s rep ort (ac c essed  throug h the list 
    measurements atm setup-events
    ) shows:
    nevent d ate
    nevent time
    nevent type (delayed or failed)
    nd elay time (in ms)
    nfrom/to PN c onnec tion numb ers
    nPNC c onnec tion (A-PNC or B-PNC)
    Syn t a x :  list measurements atm setup-events
     [
    x] or [from-conn x] [to-conn x] 
    [
    print or schedule]
    Setup Count:The numb er of SVCs setup  d uring  the time p eriod  
    ind ic ated . Values: 0 - 9999999
    AddParty Count:The numb er of ADDPARTY req uests proc essed. 
    Values: 0 - 9999999
    Total Count:The total numb er of SETUP and  ADDPARTY req uests. 
    Values: 0 - 9999999
    Average Latency:Averag e latency in milliseconds for SVC type d escrib ed  
    d uring  the time p eriod ind icated. Values:  0 - 8000
    Failure Count:The numb er of SVCs of the type d escrib ed  that could  not 
    be established by the ATM network during the time period. 
    This does not inc lud e d elayed  SVCs; that is, the d elay 
    exceed ed  the threshold set for Timeout (msec): on the 
    ATM-Related  System Parameters form. Values: 0 - 9999.  
    The numb er “ 9999”  displays if the value is g reater than 
    9999.
    (msec) Count:The numb er of d elayed  SVCs that fell within the time rang e 
    (millisec ond s) d uring  the time p eriod  ind icated . 
    Values: 0 - 9999999
    (sec) Count:The numb er of d elayed  SVCs that fell within the time rang e 
    (second s) d uring  the time p eriod  ind icated . Values: 0 - 
    9999999 
    						
    							DEFINITY ECS Release 8.2 ATM Installation,
    Upgrades, and Administration  555-233-124  Issue 1
    April 2000
    Troubleshooting 
    6-48 Troubleshooting ATM-PNC 
    6
    The c ommand  syntax allows you to list setup  events for a p artic ular c onnec tion 
    numb er or for a rang e of c onnec tion numb ers (Table 6-12
    ).
    The rep ort from the list measurement atm setup-events
     c ommand  looks like 
    Screen 6-19
    Screen 6-19. ATM-PNC delayed/failed setups report
    Table 6-12. Constricted bandwidth administration procedure
    Command Description
    list measurements atm setup-eventsLists up to 100 of the most rec ent setup  
    events
    list measurements atm setup-events
     from-conn 3Lists all setup  events from c onnec tion 3 to all 
    other connec tions
    list measurements atm setup-events
    from-conn 3 to-conn 4Lists all setup  events from c onnec tion 3 to 
    c onnec tion 4
    list measurements atm setup-events
    to-conn 4Lists all setup  events from all connec tions to 
    c onnec tion 4
    list measurements atm setup-events 4Lists all setup  events from or to connection 4
    Continued on next page
    list measurements atm setup-events
                                                            Page 1
    Switch Name:        Date: 2:33 pm  TUE DEC 12, 1999
                         ATM PNC DELAYED/FAILED SETUPS
    Date       Time      Event    Delay(msec)    From Conn To Conn  PNC 
    12/12/1999 14:32:10  delayed  1765               3        7     A-PNC
    12/12/1999 14:31:37  failed                      3        7     A-PNC
    12/12/1999 14:31:22  delayed  1809               7        8     A-PNC
    12/12/1999 14:31:18  delayed  1672              12        6     B-PNC
    12/12/1999 14:31:15  delayed  1023               3        7     B-PNC
    12/12/1999 14:29:45  delayed  1005               1        3     B-PNC
    12/12/1999 14:29:23  failed                      3        1     A-PNC
    12/12/1999 14:28:12  failed                      6        2     A-PNC
    12/12/1999 14:27:56  delayed  2088               6        7     A-PNC
    12/12/1999 14:27:24  delayed  1308               6        8     B-PNC
    12/12/1999 14:27:05  delayed  1011               6        2     A-PNC
    12/12/1999 14:26:38  failed                     11        4     B-PNC
    12/12/1999 14:26:32  delayed  1246               3        7     A-PNC 
    						
    							DEFINITY ECS Release 8.2 ATM Installation,
    Upgrades, and Administration  555-233-124  Issue 1
    April 2000
    Troubleshooting 
    6-49 Troubleshooting ATM-PNC 
    6
    Field descriptions:
    Administration
    Use the p roc ed ure in Table 6-13 to ad minister ATM Constric ted  Band wid th.
    Switch Name:The value administered  on the system-p arameters features 
    form.
    DateTime and  d ate that the command  was executed .
    DateSystem d ate when the event oc curred  (4-c harac ter).
    Time:System time when the event occ urred
    Event:The typ e of event (d elayed or failed )
    Delay (msec):The delay value is only displayed for delayed events. For failed 
    events, this field  is b lank. Values rang e from 250 to 20,000
    From Conn:The orig inating  connec tion numb er
    To Conn:The d estination c onnection numb er
    PNC: A-PNC or B-PNC
    Table 6-13. Constricted bandwidth administration procedure
    ÖStep Action Description
    1. Turn feature on Turn the feature on by chang ing  the Async. 
    Transfer Mode (ATM)? field  on the customer 
    op tions form (change system-parameters 
    customer-options) to y (
    Screen 6-20). This req uires 
    a Lucent Services log in.
    2. Set threshold s Set the imp airment thresholds in 4 field s on the 
    ATM-Related  System Parameters form (change 
    system-parameters atm) shown in 
    Screen 6-21:
    nActivation (%)
    nDeactivation (%)
    nTimeout (msec)
    nDeny Calls Using Impaired Paths?
    Pr es s 
    En te r to effec t the chang es.
    Continued on next page 
    						
    							DEFINITY ECS Release 8.2 ATM Installation,
    Upgrades, and Administration  555-233-124  Issue 1
    April 2000
    Troubleshooting 
    6-50 Troubleshooting ATM-PNC 
    6
    Constricted bandwidth administration screens
    Screen 6-20. Optional features—screen 2
    3. Set alarm op tions Alarms g enerated d ue to imp aired  p aths are rep orted 
    ag ainst the ATM-NTWK maintenanc e object. The 
    d efault alarm level is WARNING, b ut may be 
    ad ministered as either MINOR or WARNING.
    nUse the set options and  press Enter to c hang e 
    the Off-board ATM Network Alarms field  on 
    the Alarm Rep orting Op tions form (
    Screen 6-22).
    Table 6-13. Constricted bandwidth administration procedure — Continued
    ÖStep Action Description
    Continued on next page
     change system-parameters customer-options                       Page   2 of   6 
                                    OPTIONAL FEATURES                              
        Abbreviated Dialing Enhanced List? y                       CAS Branch? y
            Access Security Gateway (ASG)? y                         CAS Main? y
            Analog Trunk Incoming Call ID? y                Change COR by FAC? n
     A/D Grp/Sys List Dialing Start at 01? y  Cvg Of Calls Redirected Off-net? y
    Answer Supervision by Call Classifier? y                      DCS (Basic)? y
                                      ARS? y                DCS Call Coverage? y
                     ARS/AAR Partitioning? y               DCS with Rerouting? y
                 ARS/AAR Shortcut Dialing? n           DEFINITY Network Admin? y
                                               Digital Loss Plan Modification? n
           ASAI Proprietary Adjunct Links? y                          DS1 MSP? y
           Async. Transfer Mode (ATM) PNC? y    Emergency Access to Attendant? y
      Async. Transfer Mode (ATM) Trunking? y           Extended Cvg/Fwd Admin? y
                                     ATMS? y      External Device Alarm Admin? y
                      Attendant Vectoring? n                 Flexible Billing? y
                  Audible Message Waiting? y    Forced Entry of Account Codes? y
                      Authorization Codes? y       Global Call Classification? y
            (NOTE: You must logoff & login to effect the permission changes.) 
    						
    							DEFINITY ECS Release 8.2 ATM Installation,
    Upgrades, and Administration  555-233-124  Issue 1
    April 2000
    Troubleshooting 
    6-51 Troubleshooting ATM-PNC 
    6
    Screen 6-21. ATM-related system parameters
    Field descriptions:
    Example:
    If the value for Ac tivation (%) is 5, then the value for Deac tivation (%) c an b e 0, 1, 
    2, 3, or 4.
    Activation (%)This field sp ec ifies the perc entag e of setup events for a 
    p ath to b ec ome imp aired . That is, if the p erc entage of 
    setup  events for a g iven p ath meets or exc eed s this 
    ad ministered  value, then it b ec omes imp aired (see 
    examp le b elow). An alarm is raised  ag ainst an ATM-IMP 
    when one or more p aths originating  from that ATM-IMP 
    b ec ome imp aired . [ Values 1 to 20, default is 4]  
    Deactivation (%)This field sp ec ifies the perc entag e of setup events for a 
    p ath to come out of the imp aired state. That is, if the 
    p erc entage of setup events for an imp aired p ath meets or 
    d rop s b elow this ad ministered  value, then it is no long er 
    imp aired  (see examp le b elow). An alarm is retired  when no 
    more imp aired  p aths are orig inating from that ATM-IMP. 
    [ Values 0 to19, d efault is 3]
    Timeout (msec)The maximum number of millisec ond s allowed  for an SVC 
    connec tion to be comp leted  b efore b eing  c ounted  as 
    d elayed. [ Values 250 to 20,000, d efault is 1000]
    Deny Calls Using 
    Impaired Paths?This field sp ec ifies whether to d eny calls that use 
    connec tions over imp aired  p aths. If the op tion is y, then 
    calls that req uire a new SVC on an impaired  p ath on the 
    ac tive PNC are not c omp leted. If the op tion is n, then those 
    calls are treated  ac c ord ing  to c urrent ad ministered  
    p arameters for ATM PNC. [ Default is n]
    change system-parameters atm                                              Page 1
                          ATM-RELATED SYSTEM PARAMETERS
      THRESHOLDS OF SETUP EVENTS TO DECLARE IMPAIRMENT
                                              Activation (%):  4
                                            Deactivation (%):  3
                                              Timeout (msec):  1000
                         
      TREATMENT DURING IMPAIRED CONDITIONS
                             Deny Calls Using Impaired Paths?  n 
    						
    							DEFINITY ECS Release 8.2 ATM Installation,
    Upgrades, and Administration  555-233-124  Issue 1
    April 2000
    Troubleshooting 
    6-52 Troubleshooting ATM-PNC 
    6
    Screen 6-22. Alarm reporting options—screen 1
    set options                                                     Page 1 of   2
                               ALARM REPORTING OPTIONS
                                                  Major Minor
                           On-board Station Alarms: w    w
                          Off-board Station Alarms: w    w
             On-board Trunk Alarms (Alarm Group 1): y    y
            Off-board Trunk Alarms (Alarm Group 1): w    w
             On-board Trunk Alarms (Alarm Group 2): w    w
            Off-board Trunk Alarms (Alarm Group 2): w    w
             On-board Trunk Alarms (Alarm Group 3): w    w
            Off-board Trunk Alarms (Alarm Group 3): w    w
             On-board Trunk Alarms (Alarm Group 4): w    w
            Off-board Trunk Alarms (Alarm Group 4): w    w
                      On-board Adjunct Link Alarms: w    w
                     Off-board Adjunct Link Alarms: w    w
                        Off-board MASI Link Alarms:      w
                              Off-board DS1 Alarms: w    w
                          Off-board PI-LINK Alarms: w    w
                          Off-board Alarms (Other): w    w
      Off-board ATM Network Alarms:       w 
    						
    							Baselining the Customer’s Configuration 
    A-1 ATM Switch Administration 
    A
    DEFINITY ECS Release 8.2 ATM Installation,
    Upgrades, and Administration  555-233-124  Issue 1
    April 2000
    A
    Baselining the Customer ’s 
    Configuration
    Ap p end ix A p rovid es a worksheet for rec ord ing  information ab out the c ustomer’s 
    c onfig uration. The kind s of information to b aseline inc lud es:
    nATM Switc h Administration
    nInterc onnec tions
    nDEFINITY ECS Administration Worksheet
    ATM Switch Administration
    Refer to your Luc ent ATM switc h’s q uic k referenc e g uid e. 
    						
    							DEFINITY ECS Release 8.2 ATM Installation,
    Upgrades, and Administration  555-233-124  Issue 1
    April 2000
    Baselining the Customer’s Configuration 
    A-2 Interconnections 
    A
    Interconnections
    Rec ord  the interc onnec tion of fiber op tic  c abling  on the LIU form (Fi g u re  A - 1). 
    Rec ord  the DEFINITY port network numb er b elow the ATM switc h p ort in Ta b l e  
    A-1.
    Figure A-1. Sample lightwave interface unit (LIU)
    PN 15
    08D02
    PN 15
    08E01 PN 12
    07B02
    PN 12
    07A01
    PN 16
    09B02
    PN 16
    09A01 PN 13
    07D02
    PN 13
    07E01
    PN 17
    09D02
    PN 17
    09E01 PN 14
    08B02
    PN 14
    08A01
    PN 9
    05D02
    PN 9
    05E01 PN 6
    04B02
    PN 6
    04A01
    PN 10
    06B02
    PN 10
    06A01 PN 7
    04D02
    PN 7
    04E01
    PN 11
    06D02
    PN 11
    06E01 PN 8
    05B02
    PN 8
    05A01
    ATM-B to FM5
    Data Center
    ATM-A to FM5
    Data Center
    Lightwave Interface Unit (LIU)
    fodfliu EWS 102398 
    						
    							DEFINITY ECS Release 8.2 ATM Installation,
    Upgrades, and Administration  555-233-124  Issue 1
    April 2000
    Baselining the Customer’s Configuration 
    A-3 DEFINITY ECS Administration Worksheet 
    A
    DEFINITY ECS Administration 
    Worksheet
    Use the samp le worksheet in this sec tion to b aseline the c ustomer’s ATM 
    c onfig uration for stand ard  and  hig h reliab ility systems (see Ta b l e  A - 1
    ). Make 
    c op ies as need ed .
    NOTE:
    Be sure to leave this worksheet or a c op y of it on site. 
    						
    							DEFINITY ECS Release 8.2 ATM Installation,
    Upgrades, and Administration  555-233-124  Issue 1
    April 2000
    Baselining the Customer’s Configuration 
    A-4 DEFINITY ECS Administration Worksheet
    A
    Customer Worksheet for Standard and High Reliability Systems
    Luc ent ATM switc h ad d ress (26-d igits):                                                                           
    ATM  s w itc h l oc a tio n:__________________________________________
    D EFIN ITY EC S s w i tc h  loc ati on:__________________________________________
    Table A-1. Customer configuration worksheet for standard and high reliability systemsAT M  
    switch
    port
    A-PNC
    B-PNC
    AT M -
    PNC 
    numberDEFINITY
    location
    (UUCSS
    1) NameESI (MAC)
    2 
    address
    last 12 digits
    AT M -
    PNC 
    numberDEFINITY
    location
    (UUCSS) NameESI (MAC) 
    address
    last 12 digits
    Continued on next page 
    						