Have a look at the manual Lucent Technologies Definity Release 8.2 Atm Installation Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 413 Lucent Technologies manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.
DEFINITY ECS Release 8.2 ATM Installation, Upgrades, and Administration 555-233-124 Issue 1 April 2000 Troubleshooting 6-47 Troubleshooting ATM-PNC 6 Field descriptions: 2. The ATM PNC Delayed /Failed Setup s rep ort (ac c essed throug h the list measurements atm setup-events ) shows: nevent d ate nevent time nevent type (delayed or failed) nd elay time (in ms) nfrom/to PN c onnec tion numb ers nPNC c onnec tion (A-PNC or B-PNC) Syn t a x : list measurements atm setup-events [ x] or [from-conn x] [to-conn x] [ print or schedule] Setup Count:The numb er of SVCs setup d uring the time p eriod ind ic ated . Values: 0 - 9999999 AddParty Count:The numb er of ADDPARTY req uests proc essed. Values: 0 - 9999999 Total Count:The total numb er of SETUP and ADDPARTY req uests. Values: 0 - 9999999 Average Latency:Averag e latency in milliseconds for SVC type d escrib ed d uring the time p eriod ind icated. Values: 0 - 8000 Failure Count:The numb er of SVCs of the type d escrib ed that could not be established by the ATM network during the time period. This does not inc lud e d elayed SVCs; that is, the d elay exceed ed the threshold set for Timeout (msec): on the ATM-Related System Parameters form. Values: 0 - 9999. The numb er “ 9999” displays if the value is g reater than 9999. (msec) Count:The numb er of d elayed SVCs that fell within the time rang e (millisec ond s) d uring the time p eriod ind icated . Values: 0 - 9999999 (sec) Count:The numb er of d elayed SVCs that fell within the time rang e (second s) d uring the time p eriod ind icated . Values: 0 - 9999999
DEFINITY ECS Release 8.2 ATM Installation, Upgrades, and Administration 555-233-124 Issue 1 April 2000 Troubleshooting 6-48 Troubleshooting ATM-PNC 6 The c ommand syntax allows you to list setup events for a p artic ular c onnec tion numb er or for a rang e of c onnec tion numb ers (Table 6-12 ). The rep ort from the list measurement atm setup-events c ommand looks like Screen 6-19 Screen 6-19. ATM-PNC delayed/failed setups report Table 6-12. Constricted bandwidth administration procedure Command Description list measurements atm setup-eventsLists up to 100 of the most rec ent setup events list measurements atm setup-events from-conn 3Lists all setup events from c onnec tion 3 to all other connec tions list measurements atm setup-events from-conn 3 to-conn 4Lists all setup events from c onnec tion 3 to c onnec tion 4 list measurements atm setup-events to-conn 4Lists all setup events from all connec tions to c onnec tion 4 list measurements atm setup-events 4Lists all setup events from or to connection 4 Continued on next page list measurements atm setup-events Page 1 Switch Name: Date: 2:33 pm TUE DEC 12, 1999 ATM PNC DELAYED/FAILED SETUPS Date Time Event Delay(msec) From Conn To Conn PNC 12/12/1999 14:32:10 delayed 1765 3 7 A-PNC 12/12/1999 14:31:37 failed 3 7 A-PNC 12/12/1999 14:31:22 delayed 1809 7 8 A-PNC 12/12/1999 14:31:18 delayed 1672 12 6 B-PNC 12/12/1999 14:31:15 delayed 1023 3 7 B-PNC 12/12/1999 14:29:45 delayed 1005 1 3 B-PNC 12/12/1999 14:29:23 failed 3 1 A-PNC 12/12/1999 14:28:12 failed 6 2 A-PNC 12/12/1999 14:27:56 delayed 2088 6 7 A-PNC 12/12/1999 14:27:24 delayed 1308 6 8 B-PNC 12/12/1999 14:27:05 delayed 1011 6 2 A-PNC 12/12/1999 14:26:38 failed 11 4 B-PNC 12/12/1999 14:26:32 delayed 1246 3 7 A-PNC
DEFINITY ECS Release 8.2 ATM Installation, Upgrades, and Administration 555-233-124 Issue 1 April 2000 Troubleshooting 6-49 Troubleshooting ATM-PNC 6 Field descriptions: Administration Use the p roc ed ure in Table 6-13 to ad minister ATM Constric ted Band wid th. Switch Name:The value administered on the system-p arameters features form. DateTime and d ate that the command was executed . DateSystem d ate when the event oc curred (4-c harac ter). Time:System time when the event occ urred Event:The typ e of event (d elayed or failed ) Delay (msec):The delay value is only displayed for delayed events. For failed events, this field is b lank. Values rang e from 250 to 20,000 From Conn:The orig inating connec tion numb er To Conn:The d estination c onnection numb er PNC: A-PNC or B-PNC Table 6-13. Constricted bandwidth administration procedure ÖStep Action Description 1. Turn feature on Turn the feature on by chang ing the Async. Transfer Mode (ATM)? field on the customer op tions form (change system-parameters customer-options) to y ( Screen 6-20). This req uires a Lucent Services log in. 2. Set threshold s Set the imp airment thresholds in 4 field s on the ATM-Related System Parameters form (change system-parameters atm) shown in Screen 6-21: nActivation (%) nDeactivation (%) nTimeout (msec) nDeny Calls Using Impaired Paths? Pr es s En te r to effec t the chang es. Continued on next page
DEFINITY ECS Release 8.2 ATM Installation, Upgrades, and Administration 555-233-124 Issue 1 April 2000 Troubleshooting 6-50 Troubleshooting ATM-PNC 6 Constricted bandwidth administration screens Screen 6-20. Optional features—screen 2 3. Set alarm op tions Alarms g enerated d ue to imp aired p aths are rep orted ag ainst the ATM-NTWK maintenanc e object. The d efault alarm level is WARNING, b ut may be ad ministered as either MINOR or WARNING. nUse the set options and press Enter to c hang e the Off-board ATM Network Alarms field on the Alarm Rep orting Op tions form ( Screen 6-22). Table 6-13. Constricted bandwidth administration procedure — Continued ÖStep Action Description Continued on next page change system-parameters customer-options Page 2 of 6 OPTIONAL FEATURES Abbreviated Dialing Enhanced List? y CAS Branch? y Access Security Gateway (ASG)? y CAS Main? y Analog Trunk Incoming Call ID? y Change COR by FAC? n A/D Grp/Sys List Dialing Start at 01? y Cvg Of Calls Redirected Off-net? y Answer Supervision by Call Classifier? y DCS (Basic)? y ARS? y DCS Call Coverage? y ARS/AAR Partitioning? y DCS with Rerouting? y ARS/AAR Shortcut Dialing? n DEFINITY Network Admin? y Digital Loss Plan Modification? n ASAI Proprietary Adjunct Links? y DS1 MSP? y Async. Transfer Mode (ATM) PNC? y Emergency Access to Attendant? y Async. Transfer Mode (ATM) Trunking? y Extended Cvg/Fwd Admin? y ATMS? y External Device Alarm Admin? y Attendant Vectoring? n Flexible Billing? y Audible Message Waiting? y Forced Entry of Account Codes? y Authorization Codes? y Global Call Classification? y (NOTE: You must logoff & login to effect the permission changes.)
DEFINITY ECS Release 8.2 ATM Installation, Upgrades, and Administration 555-233-124 Issue 1 April 2000 Troubleshooting 6-51 Troubleshooting ATM-PNC 6 Screen 6-21. ATM-related system parameters Field descriptions: Example: If the value for Ac tivation (%) is 5, then the value for Deac tivation (%) c an b e 0, 1, 2, 3, or 4. Activation (%)This field sp ec ifies the perc entag e of setup events for a p ath to b ec ome imp aired . That is, if the p erc entage of setup events for a g iven p ath meets or exc eed s this ad ministered value, then it b ec omes imp aired (see examp le b elow). An alarm is raised ag ainst an ATM-IMP when one or more p aths originating from that ATM-IMP b ec ome imp aired . [ Values 1 to 20, default is 4] Deactivation (%)This field sp ec ifies the perc entag e of setup events for a p ath to come out of the imp aired state. That is, if the p erc entage of setup events for an imp aired p ath meets or d rop s b elow this ad ministered value, then it is no long er imp aired (see examp le b elow). An alarm is retired when no more imp aired p aths are orig inating from that ATM-IMP. [ Values 0 to19, d efault is 3] Timeout (msec)The maximum number of millisec ond s allowed for an SVC connec tion to be comp leted b efore b eing c ounted as d elayed. [ Values 250 to 20,000, d efault is 1000] Deny Calls Using Impaired Paths?This field sp ec ifies whether to d eny calls that use connec tions over imp aired p aths. If the op tion is y, then calls that req uire a new SVC on an impaired p ath on the ac tive PNC are not c omp leted. If the op tion is n, then those calls are treated ac c ord ing to c urrent ad ministered p arameters for ATM PNC. [ Default is n] change system-parameters atm Page 1 ATM-RELATED SYSTEM PARAMETERS THRESHOLDS OF SETUP EVENTS TO DECLARE IMPAIRMENT Activation (%): 4 Deactivation (%): 3 Timeout (msec): 1000 TREATMENT DURING IMPAIRED CONDITIONS Deny Calls Using Impaired Paths? n
DEFINITY ECS Release 8.2 ATM Installation, Upgrades, and Administration 555-233-124 Issue 1 April 2000 Troubleshooting 6-52 Troubleshooting ATM-PNC 6 Screen 6-22. Alarm reporting options—screen 1 set options Page 1 of 2 ALARM REPORTING OPTIONS Major Minor On-board Station Alarms: w w Off-board Station Alarms: w w On-board Trunk Alarms (Alarm Group 1): y y Off-board Trunk Alarms (Alarm Group 1): w w On-board Trunk Alarms (Alarm Group 2): w w Off-board Trunk Alarms (Alarm Group 2): w w On-board Trunk Alarms (Alarm Group 3): w w Off-board Trunk Alarms (Alarm Group 3): w w On-board Trunk Alarms (Alarm Group 4): w w Off-board Trunk Alarms (Alarm Group 4): w w On-board Adjunct Link Alarms: w w Off-board Adjunct Link Alarms: w w Off-board MASI Link Alarms: w Off-board DS1 Alarms: w w Off-board PI-LINK Alarms: w w Off-board Alarms (Other): w w Off-board ATM Network Alarms: w
Baselining the Customer’s Configuration A-1 ATM Switch Administration A DEFINITY ECS Release 8.2 ATM Installation, Upgrades, and Administration 555-233-124 Issue 1 April 2000 A Baselining the Customer ’s Configuration Ap p end ix A p rovid es a worksheet for rec ord ing information ab out the c ustomer’s c onfig uration. The kind s of information to b aseline inc lud es: nATM Switc h Administration nInterc onnec tions nDEFINITY ECS Administration Worksheet ATM Switch Administration Refer to your Luc ent ATM switc h’s q uic k referenc e g uid e.
DEFINITY ECS Release 8.2 ATM Installation, Upgrades, and Administration 555-233-124 Issue 1 April 2000 Baselining the Customer’s Configuration A-2 Interconnections A Interconnections Rec ord the interc onnec tion of fiber op tic c abling on the LIU form (Fi g u re A - 1). Rec ord the DEFINITY port network numb er b elow the ATM switc h p ort in Ta b l e A-1. Figure A-1. Sample lightwave interface unit (LIU) PN 15 08D02 PN 15 08E01 PN 12 07B02 PN 12 07A01 PN 16 09B02 PN 16 09A01 PN 13 07D02 PN 13 07E01 PN 17 09D02 PN 17 09E01 PN 14 08B02 PN 14 08A01 PN 9 05D02 PN 9 05E01 PN 6 04B02 PN 6 04A01 PN 10 06B02 PN 10 06A01 PN 7 04D02 PN 7 04E01 PN 11 06D02 PN 11 06E01 PN 8 05B02 PN 8 05A01 ATM-B to FM5 Data Center ATM-A to FM5 Data Center Lightwave Interface Unit (LIU) fodfliu EWS 102398
DEFINITY ECS Release 8.2 ATM Installation, Upgrades, and Administration 555-233-124 Issue 1 April 2000 Baselining the Customer’s Configuration A-3 DEFINITY ECS Administration Worksheet A DEFINITY ECS Administration Worksheet Use the samp le worksheet in this sec tion to b aseline the c ustomer’s ATM c onfig uration for stand ard and hig h reliab ility systems (see Ta b l e A - 1 ). Make c op ies as need ed . NOTE: Be sure to leave this worksheet or a c op y of it on site.
DEFINITY ECS Release 8.2 ATM Installation, Upgrades, and Administration 555-233-124 Issue 1 April 2000 Baselining the Customer’s Configuration A-4 DEFINITY ECS Administration Worksheet A Customer Worksheet for Standard and High Reliability Systems Luc ent ATM switc h ad d ress (26-d igits): ATM s w itc h l oc a tio n:__________________________________________ D EFIN ITY EC S s w i tc h loc ati on:__________________________________________ Table A-1. Customer configuration worksheet for standard and high reliability systemsAT M switch port A-PNC B-PNC AT M - PNC numberDEFINITY location (UUCSS 1) NameESI (MAC) 2 address last 12 digits AT M - PNC numberDEFINITY location (UUCSS) NameESI (MAC) address last 12 digits Continued on next page